Loading...
HomeMy WebLinkAbout1757840H-111 CEF-1 ‘ 83 TO RC-1 2 3 4 PROVIDE MIN. 6" DEEP GRILLE PLENUM BOX AT ALL RETURN GRILLES PER DETAIL ON SHEET H3.0 (TYP.) CEF-2 RTAC-1 3 RTAC-2 4 UCD ‘ DATA 116 CONSULT 6 106 CONSULT 1 101 CONSULT 2 102 CONSULT 3 103 RETAIL 100 HALLWAY 110 BREAKROOM 114 CONSULT 4 104 WOMENS RESTROOM 128 DISCOVERY ROOM 113 MENS RESTROOM 129 CONSULT 5 130 STORAGE 115 ‘ UCD 1 SG1-8 (100) SG1-8 (100) SG1-8 (100) SG1-8 (100) SG1-8 (100) SG1-8 (100) SG1-10 (300) SG2S-10/8 (300) SG2S-10/8 (300) SG2S-10/8 (300) SG2S-8/8 (200) SG2S-8/8 (200) SG2S-10/8 (300) SG2S-10/8 (300) RG1-8 (100) RG1-8 (100) RG1-8 (100) RG1-8 (100) RG1-8 (100) RG1-8 (100) RG2S-20/18 (1,200) (BOTTOM OF GRILLE AT 12'-0" A.F.F.) RG2S-12/10 (400) RG2S-14/12 (600) ‘ ‘ ‘ 18/12 20/18 29/8 5 6 16/16 12/8 14/14 14/10 14/12 12/10 18/12 ‘ ‘ 12/8 8/8 29/10 18/6 7 8 APPROX. 85' 1 1/4" GAS DN ALONG BUILDING TO NEW TENANT GAS METER- COORDINATE WITH UTILITY CO. 1 1/4" GAS ON ROOF 1" 3/4" MOUNT THERMOSTAT AT 48" A.F.F. IN LOCATIONS AS SHOWN, UNLESS LOCAL CODE AUTHORITY WILL ALLOW A MOUNTING HEIGHT OF 60" A.F.F. THERMOSTATS SHALL BE HONEYWELL VISION PRO THR8320R COMMERCIAL SERIES OR APPROVED EQUAL. THERMOSTAT FURNISHED BY HVAC CONTRACTOR. COORDINATE BUILDING PENETRATION WITH LANDLORD. PROVIDE GRAVITY BACK DRAFT DAMPER BELOW ROOF DECK. EXHAUST OUTLET LOCATION MUST BE AT LEAST 10'-0" AWAY FROM ANY OUTSIDE AIR INTAKE. ROOF TOP UNIT FOR NEW TENANT CONSTRUCTION. SEE RTAC SCHEDULE ON SHEET H4.0 & A0.1 FOR RESPONSIBILITY OF INSTALLATION. VERIFY FINAL INSTALLATION LOCATION WITH LANDLORD. TRANSITION FROM RTAC SUPPLY AND RETURN DUCT SIZES TO SIZE SHOWN ON PLAN. TRANSITION SIZE IN VERTICAL IF TRANSITION CAN MEET SPECIFICATIONS, OTHERWISE TRANSITION AFTER ELBOW. PROVIDE TURNING VANES IN DUCT ELBOWS OR TEES. 18/20 SA UP TO RTAC-1 11/29 RA UP TO RTAC-1 18/20 SA UP TO RTAC-2 11/29 RA UP TO RTAC-2 KEYED NOTES 1 2 3 4 NOTES: - DETAIL REFERENCES ON PLANS ARE TO AID THE CONTRACTOR IN IDENTIFYING THE APPLICABLE DETAIL. NOT ALL DETAILS, OR INSTANCES OF DETAILS, ARE REFERENCED ON PLANS. CONTRACTOR IS RESPONSIBLE TO REVIEW AND COMPLY WITH ALL APPLICABLE DETAILS WHETHER OR NOT REFERENCED ON PLANS. - COORDINATE LOCATION OF ALL EXPOSED PIPING AND DUCTWORK WITH OWNER PRIOR TO INSTALLATION. - IF DUCT SYSTEMS ARE USED FOR TEMPORARY HEAT, PROVIDE TEMPORARY FILTERS AT RETURN AIR OPENINGS AND INSTALL FILTERS IN THE UNITS EQUIVALENT TO THE EFFICIENCY OF THE SPECIFIED FILTERS FOR THE UNIT. IF PROPER EFFICIENCY FILTERS ARE NOT INSTALLED IN UNIT, UNIT AND ALL DUCTWORK DOWNSTREAM OF UNIT SHALL BE CLEANED BEFORE TEST AND BALANCE. - COORDINATE GRILLE LOCATIONS WITH FINAL REFLECTED CEILING PLAN AND CORRESPONDING LIGHTING CONFIGURATION. - MOUNT DUCTWORK IN AREAS AS HIGH AS POSSIBLE ABOVE SPACES WITH 10'-0" HIGH CEILINGS. 5 6 7 8 HVAC CALCULATION NOTES: HVAC CALCULATIONS ASSUMES THE FOLLOWING FOR ENVELOPE. CONSTRUCTION: - EXISTING WALL WITH BRICK VENNER/WOOD STUDS: ESTIMATED R-VALUE= 18.34 TOTAL EXSTIMATED WALL HEIGHT OF 17'-10" - ROOF: ESTIMATED R-VALUE = 20.0 - GLASS: INSULATED CLEAR GLAZING ESTIMATED U-VALUE = 0.4 ESTIMATED SHADING COEFFICIENT = 0.5 IF ACTUAL ENVELOPE CONSTRUCTION VARIES FROM THESE ESTIMATES, CONTRACTOR TO CONTACT EXCEL ENGINEERING INC. 2016 ‹ EXCEL ENGINEERING, INC. SHEET INFORMATION SHEET NUMBER PROJECT INFORMATION PROJECT NUMBER PROFESSIONAL SEAL 1757840 TENANT BUILD-OUT FOR: PROFILE BY SANFORD ϭϭϱϬϯ ^WZ/E' D/>> Z͕ ^h/d ϳϬϬ භ ZD>͕ /E ϰϲϬϯϮ NOT FOR CONSTRUCTION PRELIMINARY DATES H1.1 FIRST FLOOR PLAN JAN. 31, 2018 FLOOR PLAN SCALE: 1/4" = 1'-0" 4' 0 4' 8' 03/29/18 Nick Mishler