HomeMy WebLinkAbout1757840H-30-NON-HURRICANE FLEX CONNECTION FLEX CONNECTION -STRIP MALL 2016 ‹ EXCEL ENGINEERING, INC. SHEET INFORMATION SHEET NUMBER PROJECT INFORMATION PROJECT NUMBER PROFESSIONAL SEAL 1757840 TENANT BUILD-OUT FOR: PROFILE BY SANFORD ϭϭϱϬϯ ^WZ/E' D/>> Z͕ ^h/d ϳϬϬ භ ZD>͕ /E ϰϲϬϯϮ NOT FOR CONSTRUCTION PRELIMINARY DATES H3.0 DETAILS JAN. 31, 2018 r w MIN. r = 1.0 w TURNING VANES AIRFLOW ACCESS PANEL FOR RETURN, EXHAUST, AND OUTSIDE AIR NOT PERMITTED DUCT FITTING DETAILS NO SCALE d= bxa b+c e= cxa b+c d e b c a TEE WITH TURNING VANES SQUARE TO ROUND TRANSITION w+h 2 wxh DUCT SQUARE OR RECTANGULAR BRANCH TAKEOFF a a 4 NOT PERMITTED WHERE TEE WITH TURNING VANES IS SHOWN ON PLANS DUCT ELBOW NO SCALE GRILLE PLENUM BOX DETAIL 24 GA. SHEET METAL PLENUM BOX. PAINT INTERIOR BLACK. ACOUSTICALLY LINE AT TRANSFER AND RETURN GRILLES AND PAINT FASTENERS BLACK. MINIMUM 6" DEPTH GRILLE NECK SIZE RETURN, EXHAUST OR TRANSFER GRILLE FLEXIBLE DUCT (# AS SCHEDULED - EITHER LOCATION) INSULATION PER DUCT SCHEDULE ROOF DECK ROOF INSULATION ROOF CAP AND CURB DETAIL NOTE: - H.C. SHALL BLOCK CURB SO TOP OF CURB IS LEVEL. ROOFING AND FLASHING BY LANDLORD ROOF OPENING & ANGLE REINFORCING BY OTHERS 14" HIGH INSULATED PREFAB CURB. FURNISHED BY MFR., INSTALLED BY H.C. ROOF CAP BASE NO SCALE BLOCKING UNDER CURB BY H.C. AS REQ'D TO RAISE TOP OF CURB HEIGHT ABOVE INSULATION TO ROOFING MFR MINIMUM REQUIREMENTS. WEIGHTED GRAVITY BACK DRAFT DAMPER SEE PLAN FOR SIZE 18" MIN. 4 1/2" 3 1/4" NOTES: - FILL TRAP MANUALLY ON INITIAL START-UP. - TRAP EACH COMPONENT DRAIN CONNECTION. SQUARE HEAD PLUG (TYP.) PIPE SIZE NOT LESS THAN DRAIN PAN CONNECTION SIZE, PITCH AT 1/4" PER FOOT CONNECTION AT RTAC ROOF PIPE TO WITHIN 6" OF ROOF. EXTEND PIPING SO IT DOES NOT DISCHARGE WHERE ROOF IS PITCHED TO CURB. NO SCALE RTAC CONDENSATE DRAIN TRAP PIPING DETAIL R.T.A.C. BASE, NEOPRENE NO SCALE RTAC AND CURB ATTACHMENT DETAIL RTAC 16 GAUGE MINIMUM PRE-MANUFACTURED CURB FURNISHED BY MFR. INSTALLED BY H.C. SEE SCHED. FOR TYPE AND HEIGHT. BLOCKING UNDER CURB BY G.C. AS REQ'D TO RAISE TOP OF CURB HEIGHT ABOVE INSULATION TO ROOFING MFR MINIMUM REQUIREMENTS. BLOCKING ON TOP OF INSULATION ROOFING AND FLASHING BY LANDLORD NEOPRENE GASKET #12-14 TEK SCREWS 24" O/C - MIN. (6) IN LONG DIMENSION OF UNIT - MIN. (3) IN SHORT DIMENSION OF UNIT #12-14 TEK SCREWS 24" O/C - MIN. (6) IN LONG DIMENSION OF UNIT - MIN. (3) IN SHORT DIMENSION OF UNIT SEE STRUCTURAL PLAN FOR ADDITIONAL ROOF SUPPORT NOTE: VERIFY THICKNESS OF ROOF DECK. NOTIFY EXCEL ENGINEERING IF LESS THAN 22 GAUGE. NON-HURRICANE NO SCALE TYPICAL RTAC AND CURB DETAIL NOTE: - G.C. SHALL BLOCK CURB SO TOP OF CURB IS LEVEL. SUPPLY AIR DUCT - SEE PLAN FOR SIZE AND CONTINUATION RETURN AIR DUCT - SEE PLAN FOR SIZE AND CONTINUATION ROOF INSULATION ROOF DECK ROOFING AND FLASHING BY ROOFING CONTRACTOR FILL VOID BETWEEN DECK AND DUCT WITH MINERAL WOOL INSUL. NTS R.T.A.C. BASE, NEOPRENE GASKET, CURB BY UNIT MFR. 3/8" HARDBOARD (ON METAL DECK ONLY) 2" RIGID 6 PCF FIBERGLASS INSULATION. INSULATION BY H.C. RTAC CURB FURNISHED BY MFR. INSTALLED BY G.C. SEE SCHED. FOR TYPE AND HEIGHT. BLOCKING UNDER CURB BY G.C. AS REQ'D TO RAISE TOP OF CURB HEIGHT ABOVE INSULATION TO ROOFING MFR MINIMUM REQUIREMENTS. (2) LAYERS OF 6" FIBERGLASS BATT INSULATION. 03/29/18 Nick Mishler