Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1757840 - Sheet - A1-1 - FLOOR PLAN
F.E. E EXISTING DOOR TO REMAIN NEW DOOR SEE PLAN FOR ALL WALL WIDTHS X SEE SHEET A1.1 FOR WALL TYPES EXIT SIGNAGE FIRE EXTINGUISHER w/ CABINET -SEE SHEET A1.1 EXISTING WALL TO REMAIN EXISTING WALL TO BE DEMOLISHED SYMBOLS LEGEND RETAIL 100 CONSULT 2 102 HALLWAY 110 CONSULT 6 106 DATA 116 DISCOVERY ROOM 113 BREAKROOM 114 CONSULT 3 103 CONSULT 1 101 CONSULT 4 104 WOMENS RESTROOM 111 MENS RESTROOM 112 CONSULT 5 105 STORAGE 115 23'-6 1/2" 4 7/8" HOLD 7'-6" 4 7/8" HOLD 7'-6" 7 1/4" HOLD 7'-6" 4 7/8" 7'-7 7/8" 9 1/4" 7'-7 7/8" 4 7/8" 14'-3 3/8" 4 7/8" 3'-5 1/4" 4 7/8" 16'-0 7/8" 4 7/8" 14'-3 3/8" HOLD 4 7/8" 7'-6" HOLD 4 7/8" 7'-6" HOLD 19'-10 5/8" 4 7/8" 7'-6" 9" HOLD 9'-5" 9" HOLD 4'-9" 1'-4" 2'-0" HOLD 9'-8" 9" 4'-6 1/4" 9" HOLD 7'-4" 4'-4" 2'-0" 9" HOLD 10'-11" 9" 9'-9 1/2" 1'-4" 12'-0 1/8" 4 7/8" 4'-6 1/4" 4 7/8" 12'-0 1/8" 8'-4 3/4" 4 7/8" 8'-1 5/8" 4 7/8" 5'-11 1/8" 4 7/8" 5'-8 3/4" 26'-11 3/8" 4 7/8" 2'-0" 2'-2" 1'-4" 1 1* 1 5 3 1 1 3 1 1 2 2 2 2 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 100 101 102 104 103 105 106 111 112 114a 115 116 X114b A5.0 7 REMARKS: 1. NEW INTERIOR DOORS SHALL BE SOLID CORE, 5-PLY WOOD w/ WELDED HOLLOW METAL FRAMES. DOOR AND FRAME SHALL BE PAINTED TO MATCH WALL. 2. SEE DOOR DETAILS , , & . 3. GC TO VERIFY EXISTING HARDWARE MEETS TENANTS REQUIRMENTS, IS IN GOOD WORKING ORDER, ANDCOMPLIES w/ ADA. IF NOT, CONTRACTOR TO REPLACE w/ COMPLIANT HARDWARE. 4. GC TO PREP/PAINT EXISTING INTERIOR AND EXTERIOR OF DOOR AND FRAME TO MATCH ADJACENT WALLS. GC TO VERIFY WXTERIOR FINISH WITH BUILDING OWNER 5. DOOR AND ALL ASSOCIATED HARDWARE TO BE PROVIDED BY OWNER 6. ADD NEW ALUMINUM DOOR INTO EXISTING ALUMINUM STOREFRONT FRAME. NEW DOOR, GLAZING, FRAME AND HARDWARE TO MATCH EXISTING DOOR, GLAZING, FRAME AND HARDWARE IN FUTURE TENANT SPACE. GENERAL NOTES: 1. RE-KEY ALL EXISTING ENTRY/EXIT DOORS. PROVIDE 10 KEYS 2. PROVIDE IVES U696 150° VIEWER AT EXISTING REAR EXIT DOOR(S) WITHOUT VIEW PANELS. HARDWARE SET SCHEDULE SET DESCRIPTION LOCKSET: AL SERIES, PRIVACY (AL40S/F76)* HINGES: IVES, 1-1/2 PAIRS, 4.5x4.5 WALL STOP: IVES, WS447 CLOSER: PULL SIDE REG (689) NORTON 7501 1 LOCKSET: AL SERIES, STOREROOM (AL80PD/F86) HINGES: IVES, 1-1/2 PAIRS, 4.5x4.5 2 LOCKSET: AL SERIES, PASSAGE (AL10S/F75) HINGES: IVES, 1-1/2 PAIRS, 4.5X4.5 3 HARDWARE NOTES: 1. ALL HARDWARE FINISH TO BE 626/US26D, SATIN CHROMIUM PLATED/BRUSHED CHROME OR SIMILAR FINISH 2. UTILIZE SATURN TYPE LEVER. 3. ALL DOORS TO HAVE THREE (3) SILENCERS (TYPICAL) 4. PROVIDE BLOCKING AT WALL STOP. 5. ALL HINGES TO BE FULL MORTISE, BALL BEARING (STANDARD/MEDIUM DUTY). STAINLESS STEEL PIN. 1/A4.0 3/A4.0 4/A4.0 WD1 SOLID CORE WOOD DOOR HM1 SEE SCHEDULE 2" 2" SCHED. SEE 2" HOLLOW METAL FRAME GROUT CORES SOLID BEHIND CABINET FLOOR LINE METAL STUD WALL WOOD STUD WALL CMU WALL FIRE EXTINGUISHER / CABINET SPECIFICATION: MANUFACTURER: JL INDUSTRIES, INC. PRODUCT: FIRE EXTINGUISHER CABINET -MODEL 'AMBASSADOR' 1017V10 -PROVIDE 'FIRE-FX' FIRE RATED TUB OPTION WHEN LOCATED IN RATED WALLS (1 & 2 HOUR-RATED) -PROVIDE BLACK VERTICAL LETTERING SPELLING 'FIRE EXTINGUISHER' ON CABINET DOOR MISC: PAINT CABINET TO MATCH ADJACENT WALL FINISH 4'-6" MAX. VERIFY MANUF. SPECS R.O. PER VERIFY MANUF. SPECS R.O. PER (TYP.) 4" MAX. FIRE EXTINGUISHER: - 'COSMIC' 10E 10 lb. CAPACITY ; 4A-80BC RATING GENERAL NOTES -SEE DETAIL 6/A4.0 -SEE DETAIL 1/A1.1 (1) LAYER 5/8" PAINTED GYPSUM BOARD FILL CAVITY WITH SOUND BATT INSULATION 3 5/8" METAL STUDS @ 16" OC INTERIOR WALL TYPE LEGEND 1 1. ALL INTERIOR DIMENSIONS ARE FACE-OF-FINISH TO FACE-OF-FINISH. 2. ALL INTERIOR WALL TYPES SHALL BE CONSTRUCTED TO EXTEND TO UNDERSIDE OF STRUCTURE ABOVE (U.N.O.). PROVIDE KICKERS TO STRUCTURE, AS NECESSARY FOR SUPPORT, SEE SHEET A1.4 FOR DETAILS. UTILIZE DEFLECTION TRACK AS REQUIRED. 3. MATERIALS SHOWN IN WALL TYPES EXTEND FULL HEIGHT (U.N.O.) 4. ALL PENETRATIONS THROUGH FIRE WALL MUST BE FIRE STOPPED w/ APPROPRIATE ASSEMBLY TO MAINTAIN FIRE RATING 5. ALL PARTITIONS TO BE WALL TYPE 1, UNLESS NOTED OTHERWISE. 6. PARTITION SUPPORT KICKERS ARE NOT TO BE VISIBLE FROM HALLWAYS OR OTHER PUBLIC SPACES. 7. RESTORE RATING OF ANY EXISTING WALL IF PENETRATED. 8. GYPSUM BOARD SURFACES SHALL BE ISOLATED WITH CONTROL JOINTS AS PER MANUFACTURERS REQUIREMENTS AND INDUSTRY STANDARDS. ALL GYPSUM BOARD SURFACES ARE TO BE FINISHED SMOOTH, UNLESS NOTED OTHERWISE. GYPSUM ASSOCIATION GA-214-96 LEVEL 4 FINISH, WITH THE FOLLOWING ADDITION; ANY READILY VISIBLE IMPERFECTIONS IN GYPSUM BOARD SURFACE SHALL BE COATED WITH JOINT COMPOUND AND/OR SKIM-COATED AS REQUIRED. 9. G.C. TO VERIFY ALL WALLS HAVE MIN. R-19 BATT INSULATION AND 6 MIL POLY VAPER RETARDER INSTALLED PER MFG SPEC'S WALL TYPE (PLEASE NOTE NOT ALL WALL TYPES MAY BE USED) EXTEND TO UNDERSIDE OF STRUCTURE EXTEND TO 9'-0" AFF EXTEND TO 6" ABOVE ACT CEILING (1) LAYER 5/8" PAINTED GYPSUM BOARD FILL CAVITY WITH SOUND BATT INSULATION 6" METAL STUDS @ 16" OC WALL TYPE 3 WALL TYPE 2 (1) LAYER 5/8" PAINTED GYPSUM BOARD 3 5/8" METAL STUDS @ 16" OC (1) LAYER 5/8" PAINTED GYPSUM BOARD 6" METAL STUDS @ 16" OC WALL TYPE 4 WALL TYPE 6 (1) LAYER 5/8" PAINTED GYPSUM BOARD OVER EXISTING FURRING TO EXTEND FULL HEIGHT TO BOTTOM SIDE OF DECK WALL HEIGHT KEY (ALL WALL TYPES) EXTEND TO 6'-8" AFF (WITH SHELF ABOVE TO BE AT 7'-6") -SEE DETAIL 6/A4.0 (1) LAYER 5/8" PAINTED GYPSUM BOARD FILL CAVITY WITH SOUND BATT INSULATION 8" METAL STUDS @ 16" OC WALL TYPE 5 AS ABOVE OMITTING SOUND BATT INSULATION WALL TYPE VARIATION (ALL WALL TYPES) X* 2017 © EXCEL ENGINEERING, INC. SHEET INFORMATION SHEET NUMBER PROJECT INFORMATION PROJECT NUMBER PROFESSIONAL SEAL PRELIMINARY DATES NOT FOR CONSTRUCTION 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 WWW.EXCELENGINEER.COM ARCHITECTS ● ENGINEERS ● SURVEYORS FLOOR PLAN 1757840 TENANT BUILD-OUT FOR: PROFILE BY SANFORD 11503 SPRING MILL RD, SUITE 700 ● CARMEL, IN 46032 JAN. 31, 2018 4' 0' 4' 8' A1.1 NORTH SCALE: 1/4" = 1'-0" FLOOR PLAN DOOR SCHEDULE DOOR NO. DOOR SIZE DOOR TYPE FRAME TYPE UNDERCUT OR GRILLE (W x H) HARDWARE WIDTH HEIGHT THICKNESS SET REMARKS 100 3'-0" 9'-10" 1 3/4" GLASS 6 101 3'-0" 8'-2 1/2" 1 3/4" GLASS 2, 5 102 3'-0" 8'-2 1/2" 1 3/4" GLASS 2, 5 103 3'-0" 8'-2 1/2" 1 3/4" GLASS 2, 5 104 3'-0" 8'-2 1/2" 1 3/4" GLASS 2, 5 105 3'-0" 8'-2 1/2" 1 3/4" GLASS 2, 5 106 3'-0" 8'-2 1/2" 1 3/4" GLASS 2, 5 111 3'-0" 7'-0" 1 3/4" WD1 HM1 1" UC 1 1 112 3'-0" 7'-0" 1 3/4" WD1 HM1 1" UC 1 1 114a 3'-0" 7'-0" 1 3/4" WD1 HM1 3 1 115 3'-0" 7'-0" 1 3/4" WD1 HM1 2 1 116 3'-0" 7'-0" 1 3/4" WD1 HM1 2 1 X114b 3'-0" 7'-0" 1 3/4" EXISTING EXISTING 3, 4 DOOR & FRAME ELEVATIONS A1.1 NOT TO SCALE 1 FIRE EXTINGUISHER CABINET 8. LOCATE WATER HEATER ON SHELF ABOVE MOP SINK AT APPROX. 7'-6" A.F.F. - 9. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL WOOD BLOCKING IN WALL PARTITIONS FOR THE PROPER ANCHORAGE OF ALL WALL ATTACHED ITEMS (I.E. TOILET ACCESSORIES, CABINETS, WALL-MOUNTED FIXTURES, CASEWORK, MILLWORK, ETC). 10. GENERAL CONTRACTOR SHALL INCLUDE ALL OWNER FURNISHED AND INSTALLED ITEMS AND OWNER FURNISHED AND CONTRACTOR INSTALLED ITEMS IN THE CONSTRUCTION, AND SHALL COORDINATE WITH THE OWNER TO ACCOMMODATE THESE ITEMS. 11. INSTALL FLOOR DRAINS & FLOOR SINKS AS REQUIRED PER LOCAL CODE. 12. ALL INTERIOR WALLS TO BE 3 5/8" OR 6" METAL STUDS @ 16" O.C. (SEE FLOOR PLAN FOR SIZE) W/ 5/8" GYPSUM BOARD BOTH SIDES. 13. G.C. TO COORDINATE CLEARANCE & DIMENSIONS OF ALL OWNER SUPPLIED FIXTURES & FURNITURE TO ADJUST FRAMED OPENINGS & BLOCKING AS NEEDED TO COMPLY WITH FINAL DIMENSIONS. 14. MISCELLANEOUS HARDWARE INCLUDED: HANDICAP HARDWARE, MEN'S AND WOMEN'S REST ROOM SIGNS. 15 CONTRACTOR TO VERIFY IF EXISTING GYP BOARD RUNS TO THE BOTTOM OF DECK. IF NOT CONTRACTOR TO ADD GYP BOARD AS REQUIRED. IF BEAM/COMUMNS EXIST, CONTRACTOR TO FUR OUT AS NEEDED 1. UNLESS NOTED OTHERWISE, GENERAL NOTES APPLY TO ALL DRAWINGS IN THIS SET. 2. GENERAL CONTRACTOR SHALL VISIT PROJECT SITE PRIOR TO SUBMITTAL OF BID. CONTRACTOR SHALL ESTABLISH SCOPE OF WORK FROM CONSTRUCTION DOCUMENTS AND ACTUAL PROJECT SITE VISIT. ANY OMISSIONS, DISCREPANCIES OR CLARIFICATIONS ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTIONS OF SYMPATECO, INC. AND OWNER. FAILURE OF THE CONTRACTOR TO PERFORM IN THIS MANNER DOES NOT ALLOW FOR ADDITIONAL COSTS TO THE OWNER. 3. ANY DEVIATIONS FROM THE CONTRACT DOCUMENTS WHICH ARE NECESSITATED BY FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER. 4. FLOOR PLAN NOT GUARANTEED TO BE 100% ACCURATE. FIELD VERIFICATION IS REQUIRED FOR DIMENSIONAL ACCURACY. DO NOT SCALE OFF OF DRAWINGS. 5. ALL WORK SHALL CONFORM TO THE REQUIREMENTS WITHIN THE CURRENT EDITIONS OF ALL LOCAL, CITY, STATE AND FEDERAL APPLICABLE CODES ADOPTED BY THE LOCAL JURISDICTION. 6. ANY SHUT DOWN OF THE FIRE PROTECTION SYSTEM SHALL BE COORDINATED WITH THE LANDLORD. (WHERE APPLICABLE) 7. FIRE EXTINGUISHER SHALL BE MINIMUM 10 LB. OR AS REQUIRED BY CODE. UTILIZE ABC TYPE WITH SEMI-RECESSED CABINET WHERE SHOWN. - 03/29/18 Nick Mishler