HomeMy WebLinkAbout1757840 - Sheet - CS1-0 - TITLE SHEETDETAIL CALLOUT REFERENCE SECTION CUT REFERENCE DETAIL IDENTIFICATION KEYED NOTE AREA INCLUDED IN DETAIL DETAIL NUMBER SHEET NUMBER ON WHICH DETAIL IS LOCATED DETAIL NUMBER SHEET NUMBER ON WHICH DETAIL IS LOCATED DIRECTION OF CUT NOTE NUMBER (SEE KEYNOTE LEGEND - SAME SHEET) POINTS TO LOCATION AFFECTED BY NOTE DETAIL NUMBER DETAIL SCALE SHEET NUMBER ON WHICH DETAIL IS LOCATED A101 1 3 4 2 SHEET NUMBER OF ELEVATIONS ELEVATION NUMBER DIRECTION OF VIEW INTERIOR ELEVATION REFERENCE FLOOR LINE 100'-0" ITEM OR OBJECT BEING DEFINED ELEVATION ELEVATION MARKER AD 1 CB 1 REVISIONS GRAPHICALLY OUTLINES CHANGES CLASSIFIES WHICH SEQUENCE THE CHANGES BELONG TO (ISSUE DATES ARE LISTED ON SHEET BORDERS & SHEET INDEX) REVISION ADDENDUM CONSTRUCTION BULLETIN A101 1 A101 1 VIEW NAME A101 SCALE: 1/8" = 1'-0" 1 1 SANITARY FIXTURES OCCUPANT LOADS CONSTRUCTION CLASSIFICATION APPLICABLE BUILDING CODES BUILDING SIZE PLUMBING FIXTURE FACTORS BASED ON 2012 INTERNATIONAL BUILDING CODE, TABLE 2902.1 15.85 7.24 RETAIL 30 GROSS 22.46 OFFICE 100 GROSS TOTAL OCCUPANT LOAD OF THE BUILDING = 49 OCCUPANTS BUSINESS AREAS 674 724 111 7 NET CONFERENCE ROOM MERCANTILE GRADE FLOOR AREAS OCCUPANT LOADS BASED ON 2012 INTERNATIONAL BUILDING CODE, TABLE 1004.1.2 STORAGE ROOM 1.70 ACCESSORY STORAGE AREAS 512 300 GROSS TENANT BUILD-OUT 2,405 SF TYPE II(B) CONSTRUCTION ENTIRE BUILDING IS FULLY EQUIPPED w/ AN AUTOMATIC SPRINKLER SYSTEM PER N.F.P.A. 13 OCCUPANCY CLASSIFICATIONS NON SEPARATED USES w/ MIXED OCCUPANCY CLASSIFICATIONS WITHIN TENANT SPACE INCLUDE: MERCANTILE GROUP M BUSINESS GROUP B STORAGE GROUP S-1 ASSEMBLY GROUP A-3 MEANS OF EGRESS 250 FT. EXIT ACCESS TRAVEL DISTANCE (SPRINKLERED) EGRESS WIDTH PER OCCUPANT SERVED = 0.2" (SPRINKLERED) (49) TOTAL OCCUPANTS x 0.2" = 9.8" EGRESS WIDTH REQUIRED PROVIDED EGRESS WIDTH = 72" OCCUPANT LOAD BY CALCULATION DENSITY SF/PERSON FLOOR AREA (S.F.) CLASSIFICATION OF OCCUPANCY FOR USE ROOM OR SPACE DESIGNATION ASSEMBLY CONCENTRATED 1/750 1/1000 M GROUP (MERCANTILE) 23 PERSONS (12 M / 12 F) 1/500 .024 1 (WC) 2 1/100 1/1000 S GROUP (STORAGE) 2 PERSONS (1 M / 1 F) 1/100 .01 8 PERSONS (4 M / 4 F) .16 B GROUP (OFFICE) 1/100 OCCUPANCY WATER CLOSETS LAVATORIES DRINK FOUNTAINS TYPE CAPACITY FACTORS # M. FIX. # F. FIX. FACTORS # FIX. FACTORS # FIX. TOTAL .244 PROVIDED FIXTURES 1 1/25 (FIRST 50) 1/50 (AFTER) 1/40 (FIRST 80) 1/80 (AFTER) 16 PERSONS (8 M / 8 F) .05 A-3 GROUP (LECTURE HALL) 1/200 1/1000 1/150 (MEN) 1/75 (WOMEN) .024 .01 .16 .294 .10 .023 .002 .08 .121 .016 1 (WC) .03 .02 .20 .33 .08 2014 INDIANA BUILDING CODE (IBC 2012) 2012 INDIANA PLUMBING CODE 2009 INDIANA ELECTRIC CODE (NFPA 70-2008) 2014 INDIANA MECHANICAL CODE (IMC 2012) 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1 2007) 2014 INDIANA FIRE CODE (IFC 2012) 2014 INDIANA FUEL GAS CODE (IFGC 2012) AFF AHU ANSI ARCH BLDG CATV CLG CLR CONC CONST CONTR CT DF DIM DISP EDF EP EEP EFD EXST EXTG EXT FD FLUOR GC GWB GYP HC HVAC INSUL INT LAV LOC MAX MIN NIC NTS OC OPNG PLAM PLBG PLYWD REQ RM SI TYP VAC VTR ABOVE FINISHED FLOOR AIR HANDLER UNIT AMERICAN NATIONAL STANDARDS INSTITUTE ARCHITECTURAL BUILDING CABLE TELEVISION CEILING CLEAR CONCRETE CONSTRUCTION CONTRACTOR CERAMIC TILE DRINKING FOUNTAIN DIMENSION DISPENSARY EXISTING DRINKING FOUNTAIN ELECTRIC PANEL EXISTING ELECTRICAL PANEL EXISTING FLOOR DRAIN EXISTING EXISTING EXTERIOR FLOOR DRAIN FLUORESCENT GENERAL CONTRACTOR GYPSUM WALL BOARD GYPSUM HANDICAP(ED) HEATING/VENTILATING/AIR CONDITIONING INSULATION INTERIOR LAVATORY LOCATION(S) MAXIMUM MINIMUM NOT IN CONTRACT NOT TO SCALE ON CENTER OPENING PLASTIC LAMINATE PLUMBING PLYWOOD REQUIRED (REQUIREMENTS) ROOM SYMPATECO, INC. TYPICAL VACUUM VENT THROUGH ROOF LIST OF ABBREVIATIONS ALLOWABLE AREAS OCCUPANCY CLASSIFICATIONS WITHIN OVERALL BUILDING INCLUDE: MERCANTILE GROUP M BUSINESS GROUP B STORAGE GROUP S-1 ASSEMBLY GROUP A-2 ASSEMBLY GROUP A-3 MOST RESTRICTIVE IS A-2 2012 IBC TABLE 503 MAXIMUM ALLOWABLE BUILDING AREA (At) = 9,500 S.F. PER FLOOR 2012 IBC SECTION 506.3 AREA MODIFICATION DUE TO AUTOMATIC SPRINKLER SYSTEM (Is) = 300% FOR SINGLE STORY BUILDINGS ABOVE GRADE PLANE TOTAL ALLOWABLE AREA = 38,000 S.F. PER FLOOR NO FIRE SEPARATION BETWEEN TENANTS REQUIRED OCCUPANCY CLASSIFICATIONS WILL NOT EXCEED THE TOTAL ALLOWABLE AREA OF THE BUILDING ARCHITECTURAL MEP EXCEL ENGINEERING INC. CONTACT: JAY JOHNSON 100 CAMELOT DRIVE FOND DU LAC, WI 54935 P: (920) 926-9800 F: (920) 926-9801 EXCEL ENGINEERING INC. CONTACT: MICHAEL ZAGAR 100 CAMELOT DRIVE FOND DU LAC, WI 54935 P: (920) 926-9800 F: (920) 926-9801 OWNER AGENT ACCESS COMMERCIAL, LLC CONTACT: BRIAN WEHRS 11605 MIRACLE HILLS DRIVE, SUITE 302 OMAHA, NE 68154 P: (402) 201-9108 PROJECT OWNER PROFILE BY SANFORD CONTACT: KRISTI HEY 1305 W. 18TH STREET SIOUX FALLS, SD 57105 P: (605) 312-7704 F: (605) 312-7701 • ALL WORK SHALL CONFORM TO BUILDING CODES, ORDINANCES, AND LAWS HAVING JURISDICTION AT PROJECT SITE. NOTIFY ARCHITECT IN WRITING OF ALL CONFLICTS. • EXAMINATION OF SITE: THE CONTRACTOR SHALL VISIT THE PROJECT SITE AND EXAMINE FOR HIMSELF ALL CONDITIONS AFFECTING THE WORK. CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS NECESSARY TO PREPARE THE SITE FOR EXECUTION OF THIS CONTRACT. • DIMENSIONS: DO NOT SCALE DRAWINGS. USE DIMENSIONS SHOWN ON DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY ARCHITECT IN WRITING OF DISCREPANCIES. VERIFY ALL DIMENSIONS AND CONDITIONS AND NOTIFY ARCHITECT OF ALL DISCREPANCIES IN WRITING BEFORE PROCEEDING WITH WORK. ANY ERRORS, AMBIGUITIES AND OMISSIONS IN DRAWINGS AND SPECIFICATIONS SHALL BE REPORTED TO ARCHITECT FOR CORRECTION BEFORE ANY PART OF THE WORK IS STARTED. UNLESS EXPRESSLY STIPULATED, NO ADDITIONAL ALLOWANCE WILL BE MADE IN THE CONTRACTORS' AND/OR MANUFACTURERS' FAVOR BY VIRTUE OF ERRORS, AMBIGUITIES AND/OR OMISSIONS WHICH SHOULD HAVE BEEN DISCOVERED DURING THE PREPARATION OF BID ESTIMATE AND DIRECTED TO THE ARCHITECT'S ATTENTION IN A TIMELY MANNER. • CONTRACTORS: IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY FOR PROPER COORDINATION AND COMPLETION OF THE WORK DESCRIBED. BEFORE ORDERING MATERIALS OR COMMENCING WITH WORK WHICH IS DEPENDENT UPON PROPER SIZING OF, OR INSTALLATION IN EXISTING PREVIOUS CONDITIONS, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS BY TAKING MEASUREMENTS AT BUILDING SITE AND SHALL BE RESPONSIBLE FOR THEIR CORRECTNESS. ANY DISCREPANCIES BETWEEN DRAWINGS AND/OR SPECIFICATIONS AND EXISTING CONDITIONS SHALL BE REFERRED TO THE ARCHITECT FOR ADJUSTMENT BEFORE ANY WORK AFFECTED THEREBY IS COMMENCED. • MATERIALS: WHEN REFERENCE IS MADE IN THE SPECIFICATIONS TO TRADE NAMES OR TO THE NAMES OF MANUFACTURERS, SUCH REFERENCES ARE MADE SOLELY TO DESIGNATE AND IDENTIFY QUALITY OF MATERIAL OR EQUIPMENT, AND NOT TO RESTRICT COMPETITIVE BIDDING. IF THE CONTRACTOR WISHES TO USE MATERIALS OR EQUIPMENT OTHER THAN SPECIFIED, PRIOR WRITTEN APPROVAL OF ARCHITECT AND OWNER MUST BE OBTAINED. THE ARCHITECT AND OWNER WILL APPROVE SUCH MATERIAL OR EQUIPMENT CHANGES IF THEY ARE CONSIDERED SUITABLE AND EQUAL TO THOSE SPECIFIED. • MANUFACTURER'S DIRECTIONS: ALL MANUFACTURED ARTICLES, MATERIAL AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS, UNLESS HEREIN SPECIFIED TO THE CONTRARY. • WORK AND MATERIAL NOT SPECIFIED: ANY ITEM OF WORK NECESSARY TO THE PROPER COMPLETION OF CONSTRUCTION UNDER THIS CONTRACT WHICH IS NOT SPECIFICALLY COVERED IN THE DRAWINGS AND SPECIFICATIONS SHALL BE PERFORMED IN A MANNER DEEMED GOOD PRACTICE OF THE TRADE INVOLVED. MATERIALS AND EQUIPMENT NOT SPECIFICALLY COVERED BY THE DRAWINGS AND SPECIFICATIONS SHALL BE OF A STANDARD EQUAL TO GOOD PRACTICE COMMENSURATE WITH THE CLASS OF STRUCTURE CONSTRUCTED AND TO THE MATERIALS SHOWN OR SPECIFIED HEREIN. • PERMITS, FEES AND NOTICES: THE OWNER WILL SECURE AND PAY FOR THE BUILDING PERMIT UNLESS OTHER ARRANGEMENTS ARE MADE WITH THE OWNER. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL OTHER PERMITS RELATED TO HIS WORK. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, CODES AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF HIS WORK. INSURANCE: OWNER AND ALL CONTRACTORS SHALL EFFECT AND MAINTAIN PROPER INSURANCE. • CHANGES IN WORK: ALL CHANGES IN THE DOCUMENTS ARE TO BE DOCUMENTED BY MEMO, FIELD ORDER, OR CHANGE ORDER INITIATED BY THE ARCHITECT AND SIGNED BY OWNER AND CONTRACTOR. ACCESS COMMERCIAL, LLC. RESERVES THE RIGHT TO DETERMINE A FAIR AND EQUITABLE SOLUTION TO ANY PROBLEMS, MISTAKES, OVERSIGHTS OR HIDDEN DAMAGE. PLEASE PHONE OUR OFFICE IMMEDIATELY UPON DISCOVERY. DO NOT INSTINCTIVELY PRODUCE A SOLUTION, OR PROCEED WITH WORK THAT WOULD RESULT IN A CHANGE ORDER REQUIRING REIMBURSEMENT BY THE OWNER OR SYMPATECO, INC. ANY SOLUTIONS OUTSIDE THIS POLICY SHALL BE WITH PRIOR APPROVAL AND WILL BE AT THE FRANCHISEE'S OR CONTRACTOR EXPENSE. 2017 © EXCEL ENGINEERING, INC. SHEET INFORMATION SHEET NUMBER PROJECT INFORMATION PROJECT NUMBER PROFESSIONAL SEAL PRELIMINARY DATES NOT FOR CONSTRUCTION 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 WWW.EXCELENGINEER.COM ARCHITECTS ● ENGINEERS ● SURVEYORS TITLE SHEET 1757840 TENANT BUILD-OUT FOR: PROFILE BY SANFORD 11503 SPRING MILL RD, SUITE 700 ● CARMEL, IN 46032 JAN. 31, 2018 CS1.0 PROFILE BY SANFORD TENANT BUILD-OUT FOR: CARMEL, INDIANA PROJECT INFORMATION SYMBOLS LEGEND SHEET INDEX NUMBER SHEET NAME / DESCRIPTION SHEET ISSUE DATE LATEST SHEET REVISION NUMBER DATE GENERAL CS1.0 TITLE SHEET PRELIM T2.0 GENERAL BUILDING SPECIFICATIONS PRELIM T2.1 GENERAL BUILDING SPECIFICATIONS PRELIM ARCHITECTURAL A1.1 FLOOR PLAN PRELIM A1.2 FIXTURE PLAN PRELIM A1.3 FINISH PLAN PRELIM A1.4 REFLECTED CEILING PLAN PRELIM A4.0 DETAILS & ELEVATIONS PRELIM A5.0 ENLARGED PLANS PRELIM FIRE PROTECTION FP0.1 LEGENDS, SPECIFICATIONS, DETAILS, & SCHEDULES MNTH XX, XXX FP1.1 FLOOR PLAN MNTH XX, XXX PLUMBING P0.1 LEGENDS & SPECIFICATIONS MNTH XX, XXX P1.1 FLOOR PLAN, UNDERGROUND PLAN, & ISOMETRICS MNTH XX, XXX P2.0 ISOMETRICS MNTH XX, XXX P3.0 DETAILS MNTH XX, XXX P4.0 SCHEDULES MNTH XX, XXX HVAC H0.1 LEGENDS, SPECIFICATIONS, & DETAILS MNTH XX, XXX H1.1 FLOOR PLAN MNTH XX, XXX H3.0 DETAILS MNTH XX, XXX H4.0 SCHEDULES MNTH XX, XXX ELECTRICAL E0.1 SYMBOLS LEGEND & FIXTURE SCHEDULE PRELIM E0.2 SPECIFICATIONS PRELIM E0.3 SPECIFICATIONS PRELIM E1.1 FLOOR PLAN - ELECTRICAL PRELIM E4.0 ONELINE DIAGRAMS, SCHEDULES & DETAILS PRELIM PROJECT CONTACTS PROJECT GENERAL NOTES NOTE TO CONTRACTOR PRE-ISSUE REVIEW ITEM : PLANS DATE: JAN 19, 2018 BY: DATE REVIEWED: EXCEL ENG. DATE PROFILE DATE ACCESS COMMERCIAL DATE REVIEW AND APPROVAL OF THIS ITEM IS REQUIRED BY ALL PARTIES PRIOR TO COMPLETION OF ANY DOCUMENTS TO GC OR PERMITTING MUNICIPALITY. ADDING DATES ABOVE INDICATES THIS DOCUMENT HAS BEEN REVIEWED AND IS CONSIDERED FINAL. COORD. CALL DATE 03/29/18 Nick Mishler