HomeMy WebLinkAbout1757840 - Sheet - E0-3 - SPECIFICATIONS2. SCHEDULE TRAINING WITH OWNER, WITH AT LEAST SEVEN DAYS' ADVANCE NOTICE. 1. TRAIN DESIGNATED PERSONNEL IN CABLE-PLANT MANAGEMENT OPERATIONS, INCLUDING CHANGING SIGNAL PATHWAYS FOR DIFFERENT WORKSTATIONS, REROUTING SIGNALS IN FAILED CABLES, AND EXTENDING WIRING TO ESTABLISH NEW WORKSTATION OUTLETS. T. PROVIDE FOUR HOURS OF TRAINING. TRAIN OWNER'S MAINTENANCE PERSONNEL ON PROCEDURES AND SCHEDULES FOR STARTING AND STOPPING, TROUBLESHOOTING, SERVICING, AND MAINTAINING EQUIPMENT AND SCHEDULES. S. DEMONSTRATION: ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL AND/OR IT STAFF TO ADJUST, OPERATE, AND MAINTAIN SYSTEMS. 7. CABLE SCHEDULE: POST IN PROMINENT LOCATION IN EACH MDF AND IDF. LIST INCOMING AND OUTGOING CABLES AND THEIR DESIGNATIONS, ORIGINS, AND DESTINATIONS. PROTECT WITH CLEAR PLASTIC COVER. PROVIDE ELECTRONIC COPY OF FINAL COMPREHENSIVE SCHEDULES FOR PROJECT, IN SOFTWARE AND FORMAT SELECTED BY OWNER OR OWNER'S IT STAFF. 6. EXPOSED CABLES AND CABLES IN CABLE TRAYS AND WIRE TROUGHS: LABEL EACH CABLE AT INTERVALS NOT EXCEEDING 15 FEET (4.5 M). 5. CABLES, GENERAL: LABEL EACH CABLE WITHIN 4 INCHES (100 MM) OF EACH TERMINATION AND TAP, WHERE IT IS ACCESSIBLE IN A CABINET OR JUNCTION OR OUTLET BOX, AND ELSEWHERE AS INDICATED. 4. WITHIN CONNECTOR FIELDS, IN WIRING CLOSETS AND EQUIPMENT ROOMS: LABEL EACH CONNECTOR AND EACH DISCRETE UNIT OF CABLE-TERMINATING AND CONNECTING HARDWARE 3. DISTRIBUTION RACKS AND FRAMES: LABEL EACH UNIT AND FIELD WITHIN THAT UNIT. 2. WORKSTATION: LABEL CABLES WITHIN OUTLET BOXES. c) THIRD SYLLABLE DESIGNATES TYPE OF MEDIA (COPPER OR FIBER) AND POSITION OCCUPIED BY CABLE PAIRS OR FIBERS IN THE FIELD. b) SECOND SYLLABLE IDENTIFIES AND LOCATES CROSS-CONNECT OR PATCH-PANEL FIELD IN WHICH CABLE TERMINATES. a) FIRST SYLLABLE IDENTIFIES AND LOCATES WIRING CLOSET OR EQUIPMENT ROOM WHERE CABLE ORIGINATES. 1. USE A UNIQUE, THREE-SYLLABLE ALPHANUMERIC DESIGNATION FOR EACH CABLE, AND LABEL CABLE AND JACKS, CONNECTORS, AND TERMINALS TO WHICH IT CONNECTS WITH THE SAME DESIGNATION. USE LOGICAL AND SYSTEMATIC DESIGNATIONS FOR FACILITY'S ARCHITECTURAL ARRANGEMENT. R. SYSTEM LABELING: 5. SIGNAL GROUND BACKBONE CABLE: EXTEND FROM SIGNAL GROUND BUS TO SIGNAL GROUND TERMINAL IN EACH MDF AND IDF. 4. SIGNAL GROUND BUS: MOUNT ON WALL OF MDF AND IDF ROOMS WITH STANDOFF INSULATORS. WHEN CABINETS ARE USED FOR IDF CLOSETS MOUNT IN CABINET WITH STANDOFF INSULATORS. 3. SIGNAL GROUND TERMINAL: LOCATE IN EACH MDF AND IDF. ISOLATE FROM POWER SYSTEM AND EQUIPMENT GROUNDING. 2. BOND SHIELDS AND DRAIN CONDUCTORS TO GROUND AT ONLY ONE POINT IN EACH CIRCUIT. 1. GROUND CABLE SHIELDS, DRAIN CONDUCTORS, AND EQUIPMENT TO ELIMINATE SHOCK HAZARD AND TO MINIMIZE GROUND LOOPS, COMMON-MODE RETURNS, NOISE PICKUP, CROSS TALK, AND OTHER IMPAIRMENTS. Q. GROUNDING: 11. USE SPLICE AND TAP CONNECTORS COMPATIBLE WITH MEDIA TYPES. 10. MAKE SPLICES, TAPS, AND TERMINATIONS ONLY AT INDICATED OUTLETS, TERMINALS, AND CROSS-CONNECT AND PATCH PANELS. 9. SEPARATION OF WIRES: COMPLY WITH EIA/TIA-569 RULES FOR SEPARATING UNSHIELDED COPPER COMMUNICATION AND DATA-PROCESSING EQUIPMENT CABLES FROM POTENTIAL EMI SOURCES, INCLUDING ELECTRICAL POWER LINES AND EQUIPMENT. 8. SECURE AND SUPPORT CABLE AT INTERVALS NOT EXCEEDING 30 INCHES (760 MM) AND NOT MORE THAN 6 INCHES (150 MM) FROM CABINETS, BOXES, FITTINGS, OUTLETS, RACKS, FRAMES, AND TERMINALS. 7. PULL CABLES WITHOUT EXCEEDING CABLE MANUFACTURER'S RECOMMENDED PULLING TENSIONS. 6. DO NOT BEND CABLE IN HANDLING OR IN INSTALLING TO SMALLER RADII THAN MINIMUMS RECOMMENDED BY MANUFACTURER. 5. DO NOT DAMAGE CONDUCTORS, SHIELD, OR JACKET. 4. USE TECHNIQUES, PRACTICES, AND METHODS THAT ARE CONSISTENT WITH EIA/TIA-568 RATING OF COMPONENTS AND THAT ENSURE CATEGORY PERFORMANCE LEVEL FOR THE COMPLETED AND LINKED SIGNAL PATHS, END TO END. 3. CONCEAL RACEWAY AND WIRING EXCEPT IN UNFINISHED SPACES. 2. USE UL-LISTED PLENUM CABLE IN ENVIRONMENTAL AIR SPACES, INCLUDING PLENUM CEILINGS. 1. INSTALL WIRING IN RACEWAY AND CABLE TRAY EXCEPT WITHIN CONSOLES, CABINETS, DESKS, AND COUNTERS EXCEPT IN ACCESSIBLE CEILING SPACES AND IN GYPSUM BOARD PARTITIONS WHERE CABLE WIRING METHOD MAY BE USED. P. WIRING METHOD: a) MINIMUM. 5. PROVIDE LABELS THAT DENOTE JACK DESIGNATION FOR EACH JACK. 4. FACEPLATE SHALL ACCOMMODATE THE NUMBER OF JACKS NOTED ON THE DRAWINGS AS A MINIMUM. 3. MOUNTING: FLUSH IN FINISHED AREAS, SURFACE MOUNTED IN UNFINISHED AREAS AND PARTITION MOUNTED IN PARTITIONS, UNLESS NOTED OTHERWISE. 2. FACEPLATE: HIGH-IMPACT PLASTIC; COLOR TO MATCH FACEPLATE OF RECEPTACLE THAT SHARE THE SAME SPACE OR AS SELECTED BY ARCHITECT. FACEPLATE SHALL HAVE ALLOCATED SPACES FOR LABELS THAT DENOTE JACK DESIGNATION. 1. DUAL JACK-CONNECTOR ASSEMBLIES MOUNTED IN SINGLE OR MULTIGANG FACEPLATE UNLESS MOUNTED IN PARTITIONS THEN PARTITION FACEPLATES SHALL BE USED. O. WORKSTATION OUTLETS: e) CATEGORY: JACK CATEGORY LISTING SHALL MATCH THAT OF THE CABLE MINIMUM. d) LABELING: LABEL AT THE RACK AND AT THE FACEPLATE c) MOUNTING: RACK AND FACEPLATE b) COLOR CODE JACKS FOR DATA SERVICE. JACKS USED FOR PHONE SHALL BE A DIFFERENT COLOR THAN THE JACKS FOR DATA. ONCE COLOR IS SELECTED IT WILL BE CONSISTENT THROUGHOUT THE ENTIRE PROJECT, UNLESS NOTED OTHERWISE. a) MODULAR, COLOR-CODED, RJ-45 RECEPTACLE UNITS WITH INTEGRAL IDC-TYPE TERMINALS. 1. UTP CABLE: N. JACKS AND JACK ASSEMBLIES 4. NUMBER OF TERMINALS PER FIELD: ONE FOR EACH CONDUCTOR IN ASSIGNED CABLES. 3. IDC CONNECTING HARDWARE: CONSISTENT THROUGHOUT PROJECT. 2. IDC TERMINAL BLOCK MODULES: INTEGRAL WITH CONNECTOR BODIES, INCLUDING PLUGS AND JACKS WHERE INDICATED. 1. UTP CABLE CONNECTING HARDWARE: COMPLY WITH EIA/TIA-568-A. IDC TYPE, USING MODULES DESIGNED FOR PUNCH-DOWN CAPS OR TOOLS. M. HARDWARE: e) CABLE LABELS: SELF-ADHESIVE VINYL OR VINYL-CLOTH WRAPAROUND TAPE MARKERS, MACHINE PRINTED WITH ALPHANUMERIC CABLE DESIGNATIONS. d) TERMINATE ALL CABLES AT BOTH ENDS, UNLESS NOTED OTHERWISE. c) UTP PLENUM CABLE: LISTED FOR USE IN AIR-HANDLING SPACES. FEATURES ARE AS SPECIFIED ABOVE, EXCEPT MATERIALS ARE MODIFIED AS REQUIRED FOR LISTING. b) UTP CABLE: COMPLY WITH EIA/TIA-568-A. FOUR THERMOPLASTIC-INSULATED, INDIVIDUALLY TWISTED PAIRS OF CONDUCTORS; NO. 24 AWG, COLOR-CODED; ENCLOSED IN PVC JACKET. a) CONDUCTORS: SOLID COPPER. 2. TWISTED-PAIR CABLES, CONNECTORS, AND TERMINAL EQUIPMENT: LISTED AS COMPLYING WITH CATEGORIES 6 OF EIA/TIA-568-A. 1. DEFINITION: TYPICALLY REFERRED TO AS HORIZONTAL CABLES THAT ROUTE FROM THE DISTRIBUTION FRAME (CLOSET) TO THE JACKS IN THE FIELD (SPACE OR WORK STATION). L. BRANCH CABLES: 4. CABLE LABELS: SELF-ADHESIVE VINYL OR VINYL-CLOTH WRAPAROUND TAPE MARKERS, MACHINE PRINTED WITH ALPHANUMERIC CABLE DESIGNATIONS. 3. BACKBONE CABLES FOR VOICE SERVICE: USE UTP CABLE COMPLYING WITH 3 OF EIA/TIA-568-A FOR RUNS BETWEEN EQUIPMENT ROOMS AND WIRING CLOSETS AND FOR RUNS BETWEEN WIRING CLOSETS. 2. BACKBONE CABLE FOR DATA SERVICE: USE UTP CABLE COMPLYING WITH CATEGORY 5E OF EIA/TIA-568-A CABLE FOR RUNS BETWEEN EQUIPMENT ROOMS AND WIRING CLOSETS AND FOR RUNS BETWEEN WIRING CLOSETS. 1. DEFINITION: CABLES THAT PERMIT CONNECTION BETWEEN DISTRIBUTION FRAMES (CLOSETS) - SOMETIMES REFERRED TO AS TRUNK CABLES. K. BACKBONE CABLES: 2. PROVIDE KEYED LOCKS FOR DOORS. d) RACK MOUNTED POWER STRIP: PROVIDE 1 RACK MOUNTED POWER STRIPS AND MOUNT TO RACK PER MANUFACTURER'S RECOMMENDATIONS. THE STRIP SHALL HAVE TEN (10) NEMA 5-20R RECEPTACLES AND A SIX FOOT CORD. c) PROVIDE EQUIPMENT RAILS OR PANEL EXTENDER BRACKETS TO PERMIT MOUNTING OF 19 INCH PRODUCT. b) APPROXIMATE MODULE DIMENSIONS: 48 INCHES (1217 MM) HIGH BY 24 INCHES (620 MM) WIDE BY 36 INCHES (912MM) DEEP. a) MODULAR-STEEL UNITS DESIGNED FOR TELECOMMUNICATIONS TERMINAL SUPPORT AND COORDINATED WITH DIMENSIONS OF UNITS TO BE SUPPORTED. FINISH: BAKED-POLYESTER POWDER COAT. THE CABINET SHALL BE DOUBLE HINGED THAT PERMITS ACCESS TO BOTH FRONT AND REAR OF MOUNTED EQUIPMENT. THE CABINET SHALL HAVE A SEE THROUGH HINGED FRONT DOOR. 1. WALL MOUNTED CABINET: J. DISTRIBUTION CABINETS: 2. MOUNTING: BACKBOARD OR RACK AS INDICATED. 1. MODULAR PANELS HOUSING MULTIPLE, NUMBERED JACK UNITS WITH IDC-TYPE CONNECTORS AT EACH JACK FOR PERMANENT TERMINATION OF PAIR GROUPS OF INSTALLED CABLES. I. PATCH PANEL: 2. MOUNT PATCH PANELS, TERMINAL STRIPS, AND OTHER CONNECTING HARDWARE ON BACKBOARDS, UNLESS NOTED OTHERWISE. 1. PAINT COLOR: WHITE. H. BACKBOARDS: 3/4-INCH (19-MM) INTERIOR-GRADE, PAINTED WITH TWO COATS OF FIRE-RESISTIVE-PAINT. G. RACEWAYS AND BOXES: COMPLY WITH RACEWAY AND BOX SECTIONS OF THE ELECTRICAL SPECIFICATIONS. F. THE DISTRIBUTION EQUIPMENT SHALL BE SIZED TO HANDLE THE QUANTITY OF JACKS NOTED ON THE DRAWINGS PLUS BE ADEQUATE TO SATISFY 25 PERCENT EXPANSION, UNLESS NOTED OTHERWISE. 8. UTP - UNSHIELDED TWISTED PAIR (CABLE) 7. TIA - TELECOMMUNICATION INDUSTRY ASSOCIATION 6. STP - SHIELDED TWISTED PAIR (CABLE) 5. PVC - POLYVINYL CHLORIDE 4. MDF - MAIN DISTRIBUTION FRAME (CLOSET) 3. IDF - INTERMEDIATE DISTRIBUTION FRAME (CLOSET) 2. IDC - INTERNATIONAL DATA CORPORATION 1. EIA - ELECTRONIC INDUSTRIAL ALLIANCE E. ABBREVIATIONS: 5. GROUP CONNECTING HARDWARE FOR CABLES INTO SEPARATE LOGICAL FIELDS. 4. CONTRACTOR SHALL TEST EACH CABLE AND ITS TERMINATIONS TO INSURE THAT THE INSTALLATION MEETS EIA/TIA STANDARDS. THREE COPIES OF THIS REPORT SHALL BE PROVIDED TO THE OWNER AS PART OF RECORD DRAWINGS. 3. SYSTEM REQUIREMENTS: COORDINATE THE FEATURES OF MATERIALS AND EQUIPMENT SO THEY FORM AN INTEGRATED SYSTEM. MATCH COMPONENTS AND INTERCONNECTIONS FOR OPTIMUM FUTURE PERFORMANCE. 2. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. 1. COMPLY WITH NFPA 70. D. QUALITY CONTROL: C. INSTALLER QUALIFICATIONS: AN EXPERIENCED INSTALLER WHO IS A REGISTERED COMMUNICATION DISTRIBUTION DESIGNER CERTIFIED BY THE BUILDING INDUSTRY CONSULTING SERVICE INTERNATIONAL. B. SHOP DRAWINGS: WHEN REQUIRED BY BASIC ELECTRICAL REQUIREMENTS IT SHALL COMPLY WITH BASIC ELECTRICAL REQUIREMENTS SECTION OF THIS SPECIFICATION AND SHALL INCLUDE, BUT NOT BE LIMITED TOO, DIMENSIONED PLAN AND ELEVATION VIEWS OF COMPONENTS. SHOW ACCESS AND WORKSPACE REQUIREMENTS AND SYSTEM LABELING SCHEDULES, INCLUDING ELECTRONIC COPY OF LABELING SCHEDULES IN SOFTWARE THAT COMPLIES WITH THE FORMAT SELECTED BY OWNER. A. PRODUCT DATA: INCLUDE DATA ON FEATURES, RATINGS, AND PERFORMANCE FOR EACH COMPONENT SPECIFIED. 27 05 00 TELECOMMUNICATION PREMISE WIRING DIVISION 27 COMMUNICATIONS 2. PROVIDE RACEWAY FOR THE CONTROL CONDUCTORS THAT COMPLIES WITH THESE SPECIFICATIONS 1. PROVIDE TWO CONTROL CONDUCTORS FROM THE AUXILLARY CONTACT IN THE DISCONNECT TO THE VARIABLE FREQUENCY DRIVE'S CONTACTS. CONTACT TO INFORM THE VARIABLE FREQUENCY DRIVE THAT DISCONNECT HAS BEEN OPENED. I. FOR MOTORS THAT ARE FED WITH VARIABLE FREQUENCY DRIVES PROVIDE DISCONNECTS WITH AUXILLARY CONTACTS AS PART OF THE DISCONNECT FOR THESE MOTORS. 2. CORRECT MALFUNCTIONING UNITS, ON-SITE WHERE POSSIBLE, AND RETEST TO DEMONSTRATE COMPLIANCE. 1. PERFORM VISUAL AND MECHANICAL INSPECTION AND ELECTRICAL TEST. CERTIFY COMPLIANCE WITH TEST PARAMETERS. H. DEMONSTRATE PRODUCT CAPABILITY AND COMPLIANCE WITH REQUIREMENTS AFTER INSTALLATION AND AFTER ELECTRICAL CIRCUITRY HAS BEEN ENERGIZED. G. INSTALL EQUIPMENT GROUNDING CONNECTIONS FOR SWITCHES AND CIRCUIT BREAKERS WITH GROUND CONTINUITY TO MAIN ELECTRICAL GROUND BUS. F. LABEL EACH ENCLOSURE WITH ENGRAVED METAL OR LAMINATED-PLASTIC NAMEPLATE MOUNTED WITH CORROSION-RESISTANT SCREWS. E. MANUFACTURER'S STANDARD PRIME-COAT FINISH READY FOR FIELD PAINTING. 4. HAZARDOUS AREAS INDICATED ON DRAWINGS: NEMA 250 TYPE 7C 3. OTHER WET OR DAMP INDOOR LOCATIONS: NEMA 250 TYPE 4. 2016 © EXCEL ENGINEERING, INC. SHEET INFORMATION SHEET NUMBER PROJECT INFORMATION PROJECT NUMBER PROFESSIONAL SEAL PRELIMINARY DATES NOT FOR CONSTRUCTION 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926‐9800 WWW.EXCELENGINEER.COM ARCHITECTS ● ENGINEERS ● SURVEYORS 2/1/2018 1:14:55 PM C:\Users\AndyL\Documents\Revit Local Files\1757840_Elec_Central_(rvt 2015)_AndyL.rvt SPECIFICATIONS 1757840 TENANT BUILD‐OUT FOR: PROFILE BY SANFORD 11503 SPRING MILL RD, SUITE 700 ● CARMEL, IN 46032 JAN. 31, 2018 E0.3 03/29/18 Nick Mishler