1757840 - Sheet - E1-1 - FLOOR PLAN - ELECTRICAL
F.E. E E E E F.E. TV TV TV TV TV TV TV TV TV TV TV TV V V J CLG. TV TV SM SM SM SM SM SM J SM SM TV TV CLG. J J J J 5 A4.0 9 A4.0 4 A4.0 7 A4.0 4 A4.0 4 A4.0 4 A4.0 4 A4.0 6 A4.0 4 A4.0 COORDINATE LOCATION OF ALL EXPOSED CONDUIT WITH OWNER PRIOR TO INSTALLATION. · EXTERIOR RECEPTACLES SHALL BE GFCI TYPE. PROVIDE PASS & SEYMOUR SERIES "WI UC" OR EQUIVALENT COVER. (PER NEC 406.8(B) AND AHJ) COLOR SHALL BE SELECTED BY ARCHITECT. · VERIFY OUTLET LOCATIONS WITH OWNER PRIOR TO ROUGH-IN. · ROUGH-IN RECEPTACLES FOR ELECTRIC WATER COOLERS (EWC) BEHIND UNIT. VERIFY LOCATION PRIOR TO ROUGH-IN. · PROVIDE GFCI PROTECTION FOR ALL SINGLE PHASE RECEPTACLES LOCATED IN THE FOLLOWING LOCATIONS: BATHROOMS, KITCHENS, ROOFS, LOCKER ROOMS & SHOWERING FACILITIES, SERVING WATER COOLERS & VENDING MACHINES, GARAGES & SERVICE BAYS, WHERE WITHIN 6'-0" OF A SINK, AND ALL OTHER WET LOCATIONS. · SEE SHEET E0.1 FOR BRANCH CIRCUIT FEEDER SIZES. · ALL CONDUITS TO ISLAND CABINETRY AND TABLES SHALL BE UNDERGROUND. · COORDINATE LIGHT FIXTURE LOCATIONS IN MECHANICAL EQUIPMENT ROOMS WITH OTHER CONTRACTORS PRIOR TO ROUGH IN. · WIRE EMERGENCY LIGHTS UNSWITCHED TO LIGHTING CIRCUIT SERVING SAME ROOM, OR TO "NIGHT LIGHT" CIRCUIT WHEN AVAILABE · ALL DATA CABLING SHALL BE CAT6 AND GRAY IN COLOR WITH ONE DATA CABLE RUN TO EACH LOCATION SHOWN PER SPECIFICATIONS. · ALL ELECTRICAL, DATA CABLING ETC. SHALL BE RUN IN CONDUIT AT ALL EXPOSED CEILING LOCATIONS. NOTES POWER TO THE SOUND MASKING SPEAKERS WILL BE PROVIDED BY DC ADAPTER(S) PLUGGED INTO OUTLETS, IN THE DATA CLOSET, BELOW THE CEILING LINE. EC SHALL SPLICE THE WIRES ON ADAPTER(S) AND RUN EXTENDED PLENUM RATED CABLES TO ALL SOUND MASKING SPEAKERS ABOVE CEILING LINE, CONNECTING THEM TO EACH SPEAKER JUNCTION BOX VIA CONDUIT. NOTE: A SINGLE ADAPTER CAN POWER 2-3 SOUND MASKING SPEAKERS. SPEAKERS SHALL TURN ON/OFF WITH LIGHT SWITCHES FOR EACH ROOM. WIRING BY EC. SPEAKER PROVIDED AND INSTALLED BY OWNER. 1 2 3 4 5 6 7 ELECTRICAL KEYED NOTES: OWNER TO PROVIDE AND INSTALL A SOUND SYSTEM EQUAL TO JBL COMMERCIAL SERIES CSM-32 PUBLIC ADDRESS MIXER WITH CSA-2120 POWER AMPLIFIER, CSR-2SV ZONE CONTROLLERS. ELECTRICIAN TO PROVIDE AND INSTALL CSS8018 CEILING SPEAKERS WITH PRE-INSTALL-TYPE BACK CANS. SOUND SYSTEM SPEAKERS SHALL BE CENTERED IN LAY-IN CEILING PANELS OR SUSPENDED AT EXPOSED STRUCTURE CEILING AREAS AND AWAY FROM LIGHT FIXTURES, DIFFUSERS AND DUCTS. SEE A1.6, RCP FOR SPEAKER LOCATIONS. EC TOP ROVIDE AND INSTALL ALL WIRING AND OWNER PROVIDED VOLUME CONTROLLERS FOR CEILING SPEAKERS. NEMA L5-20R 20A 125V UL/CSA 1HP SINGLE RECEPTACLE. VERIFY POWER REQUIREMENTS WITH OWNERS EQUIPMENT SUPPLIER PRIOR TO ROUGH IN. MAKE FINAL CONNECTION TO OWNER PROVIDED SIGNAGE. PROVIDE JUNCTION BOX(ES) AND ASSOCIATED 120V, 1Ø, 20 AMP CIRCUIT FOR SIGNAGE. FIELD VERIFY EXACT ROUGH-IN LOCATION. PROVIDE INTERMATIC TIMESWITCH ET1705C FOR CONTROL. SEE EXTERIOR LIGHTING CONTROL DETAIL. COORDINATE WITH OWNER / LANDLORD. CIRCUIT AND CONTROL EXHAUST FAN WITH LIGHTING CIRCUIT AND MOTION SENSOR CONTROLS THIS ROOM. IP CAMERAS FURNISHED AND INSTALLED BY OWNER. CAT 6 CABLING SHALL BE INSTALLED FROM CAMERA LOCATIONS TO DATA ROOM BY EC. VERIFY EXACT LOCATIONS WITH OWNER PRIOR TO ROUGH-IN. 8 DOOR CHIME HEATH ZENITH WIRELESS ENTRY ALERT CHIME SL-7352. PROVIDE SECOND DOOR CHIME IN BREAKROOM. 9 E.C TO PROVIDE 4'x4' SHEET OF PAINTED PLYWOOD FOR OWNER PROVIDED DATA RACK. MOUNT PLYWOOD AT HEIGHT TO ALLOW FOR INSTALLATION OF WALL MOUNTED DATA RACK. 10 11 E.C TO PROVIDE AND INSTALL CSS8018 CEILING SPEAKERS WITH PRE-INSTALL-TYPE BACK CANS. SOUND SYSTEM SPEAKERS SHALL BE CENTERED IN LAY-IN CEILING PANELS OR SUSPENDED AT EXPOSED STRUCTURE CEILING AREAS AND AWAY FROM LIGHT FIXTURES, DIFFUSERS AND LIGHTS. E.C TO PROVIDE AND INSTALL ALL WIRING, AND OWNER PROVIDED VOLUME CONTROLLERS FOR CEILING SPEAKERS . E.C TO PROVIDE PROPER LABELING ON ALL SPEAKER AND CONTROL WIRES. 12 13 PROVIDE 1A CURRENT LIMITER. OWNER TO PROVIDE AND INSTALL DATA RACK SHALL BE COOPER B-LINE (V-LINE SERIES) MODEL NUMBER VLWM2425PB WITH POWER MANAGEMENT ACCESSORY SB30061015FB 10 OUTLET 15AMP SURGE PROTECTED POWER STRIP. SWITCH/DIMMER BANK. SEE DETAIL 5/E4.0 14 INFRARED WATER CONTROL. SEE INFRARED WATER CONTROL DETAIL ON E4.0. 15 DOUBLE DUPLEX RECEPTACLE FOR SOUND MASKING SPEAKERS ON DEDICATED CIRCUIT. 16 RECEPTACLE FOR BREAKROOM DOOR CHIME. 1. ELECTRICAL, DATA AND COMMUNICATIONS LOCATIONS ON THIS DRAWING ARE THE MINIMUM REQUIRED DROPS. ADDITIONAL DATA DROPS SHALL BE INSTALLED AS REQUIRED BY CODE. ALL ELECTRICAL, DATA AND COMMUNICATIONS SYSTEMS SHALL BE INSTALLED PER STATE AND LOCAL CODES. 2. ALL DATA CABLING SHALL BE CAT6 AND GRAY IN COLOR WITH ONE DATA CABLE RUN TO EACH LOCATION SHOWN. ELECTRICIAN SHALL BE RESPONSIBLE FOR PULLING CABLE TO ALL DATA LOCATIONS. OWNER WILL TERMINATE ALL DATA CONNECTIONS. 3. INSTALL A 1 1/4" CONDUIT FROM THE TV TO THE COMPUTER IN THE BASE CABINET AT ALL TV LOCATIONS TO ACCOMMODATE ADDITIONAL CABLING INSTALLED BY OWNER. 4. ALL ELECTRICAL, DATA CABLING ETC. SHALL BE RUN IN CONDUIT AT ALL EXPOSED CEILING LOCATIONS. 5. FOR WATER HEATER LOCATION: SEE PG. A1.1-GENERAL NOTE, A1.2 FIXTURE PLAN AND A1.4.1 ELEVATION. 6. INTERMATIC TIME SWITCH ET1705C, 30 AMPS TO BE INSTALLED FOR EXTERIOR SIGNAGE. 7. G.C. SHALL BE RESPONSIBLE FOR ACCEPTING DELIVERY, UNLOADING AND PLACING OF LIGHT FIXTURES PROVIDED BY OWNER. ELECTRICAL NOTES: "A" XE A-1 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 C16 ID4 ID4 ID4 ID4 ID4 ID4 7 3,D L2 L2 ID4 ID4 C16 C16 C16 C16 C16 C16 C16 C16 3,D 13 13 L2 L2 S4 C16 C16 C16 C16 3 3 ID4 ID4 T3 T2 T2 T2 T2 C16 C16 P1 P1 P1 C16 C16 C16 C16 T2 T2 T2 T2 T2 T2 T1 T1 T1 T2 T2 T2 C16 SW-b SW-a SW-c SW-d 3 3 D D D ID4 ID4 ID4 ID4 ID4 ID4 C16 C16 C16 C16 C16 C16 SW-a 8'-0" A-4 4'-6" 2'-0" XE A-1 XE A-1 A-2 A-6 2'-0" 4'-11" 1'-6" XE A-1 18"/60" +60" 22"/ 54" 22"/ 54" 22"/ 54" 22"/ 54" +54" +54" +54" +54" +45" +45" 18"/ 54" E.W.C ZONE 1 AUDIO EQUIPMENT TO BE INSTALLED IN CABINET "A" ZONE 2 A-11 A-13 A-13 A-19 A-19 A-15 A-17 +22" +38" +22" +22" +22" ROUTE (2) 1 1/4" CONDUIT FROM CASH WRAP TO CHASE, UNDERSLAB TO ACCESS SPACE NEAR CEILING VERIFY CASH WRAP CHASE LOCATION WITH MILLWORK CONTRACTOR. A-12 A-12 A-12 A-12 A-14 A-14 A-14 A-14 A-16 A-16 A-16 A-8 A-16 A-8 A-8 A-8 A-20 A-20 A-21 A-24 A-24 A-29 A-25 A-22 A-22 A-23 A-23 A-30 FREEZER FREEZER WH-1 A-31 2 4 5 8 8 8 CEF-1 6 CEF-2 A-28 4 3 A-9 12 9 11 (TYP.) 11 (TYP.) 22"/ 54" +54" A-10 A-10 A-10 A-10 1 GFI GFI +38" A-5 A-5 1 1 1 +22" +22" +22" +22" +10' - 6" A-26 +10' - 6" A-26 WP 1 22" +22" +22" +22" DOOR CONTACT FOR DOOR CHIME A-20 REF./18" MICRO./60" A-11 A-7 A-27 GFI GFI 9 +52" 22"/ 54" +54" A-18 A-18 A-18 A-18 +22" 22" +22" 1 +10' - 6" A-26 A-26 WAP WAP RTAC-1 A-38,40,42 WP/GFI (ON ROOF) A-35 (ON ROOF) 8 GFI A-11 A-19 A-19 RTAC-2 A-37,39,41 (ON ROOF) WP/GFI A-36 (ON ROOF) 11 (TYP.) GFI +22" 10 CLG 1 1 6 A-13 14 ZONE 1 ZONE 1 ZONE 2 ZONE 2 A-3 15 A-11 GFI A-11 16 A-13 14 HALLWAY 110 RETAIL 100 CONSULT 1 101 CONSULT 2 102 CONSULT 4 104 CONSULT 3 103 CONSULT 6 106 CONSULT 5 105 STORAGE 115 DATA 116 DISCOVERY ROOM 113 WOMENS RESTROOM 111 MENS RESTROOM 112 BREAKROOM 114 2016 © EXCEL ENGINEERING, INC. SHEET INFORMATION SHEET NUMBER PROJECT INFORMATION PROJECT NUMBER PROFESSIONAL SEAL PRELIMINARY DATES NOT FOR CONSTRUCTION 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926‐9800 WWW.EXCELENGINEER.COM ARCHITECTS ● ENGINEERS ● SURVEYORS 2/1/2018 1:14:58 PM C:\Users\AndyL\Documents\Revit Local Files\1757840_Elec_Central_(rvt 2015)_AndyL.rvt FLOOR PLAN - ELECTRICAL 1757840 TENANT BUILD‐OUT FOR: PROFILE BY SANFORD 11503 SPRING MILL RD, SUITE 700 ● CARMEL, IN 46032 JAN. 31, 2018 4' 0' 4' 8' 4' 0' 4' 8' E1.1 NORTH SCALE: 1/4" = 1'-0" FIRST FLOOR PLAN - LIGHTING NORTH SCALE: 1/4" = 1'-0" FIRST FLOOR PLAN - POWER 03/29/18 Nick Mishler