1757840 - Sheet - E4-0 - ONELINE DIAGRAMS, SCHEDULES & DETAILS
PC TIME CLOCK 'ASCO' SERIES 917 2-POLE RELAY IN NEMA 1 ENCLOSURE BRANCH CIRCUIT(S) SEE PANEL SCHEDULE FOR FEEDER DESIGNATION TO LIGHTS (TYP.) TIME CLOCK CONTROL INTERMATIC MODEL# ET1705C PHOTOEYE CONTROL 'TORK' MODEL # EPC1 OR EQUAL -LOCATE ON NORTH EXT WALL OF BUILDING & AIM NORTH (3) #12 (3) #12 A-21 (BUILDING SIGNAGE) (SPARE) 1/2" 1/2" ARMAFLEX CLOSED CELL INSULATION CONDUIT PER SPECIFICATIONS RIGID STEEL ELBOW COMPATIBLE SEALANT GRADE CONDUIT PER SPECIFIACTIONS COMPATIBLE SEALANT -BOTH SIDES EXPANDING POLYURIETHANE FOAM '3M' 2114 SEALING COMPOUND OR EQUAL AROUND CONDUCTORS -ALLOW 80 MIN. CURE TIME CONDUIT BODY OR J-BOX PROVIDE PVC SLEEVES AT NEW CONSTRUCTION (CORE DRILL FOR EXISTING WALLS) 5'-0" (MIN.) GRADE 2'-0" (MIN.) CONDUIT PER SPECIFICATIONS J-BOX OR DEEP BACK LB w/ GASKETED COVER CONDUIT PER SPECIFICATIONS WITH STAINLESS STEEL MOUNTING HARDWARE COMPATIBLE SEALANT -BOTH SIDES EXPANDING POLYURIETHANE FOAM RIGID STEEL ELBOW PROVIDE PVC SLEEVES AT NEW CONSTRUCTION (CORE DRILL FOR EXISTING WALLS) '3M' 2114 SEALING COMPOUND OR EQUAL AROUND CONDUCTORS -ALLOW 80 MIN. CURE TIME NEOPRENE BOOT CONDUIT PER SPECIFICATIONS ADJ. CLAMP PIPE SEAL -CENTER OVER OPENING CUT OPENING THRU ROOF AS REQ'D '3M' 2114 SEALING COMPOUND OR EQUAL AROUND CONDUCTORS -ALLOW 80 MIN. CURE TIME FLASHING BY ROOFING CONTRACTOR COMPATIBLE SEALANT SLAB ON GRADE FLOORS BELOW GRADE WALLS MEMBRANE ROOF ABOVE GRADE WALLS NOTES: · SEE SPECIFICATIONS FOR CONDUIT MATERIAL BEYOND COUPLINGS. · SEE SPECIFICATIONS FOR INTERIOR WALL AND FLOOR PENETRATION REQ'S. TO ADDITIONAL SENSORS IN SAME ROOM AS REQ'D CEILING MOUNTED MOTION SENSOR 3 CONDUCTOR CABLE -PROVIDE PLENUM RATED IN RETURN AIR PLENUM SPACES (TYP.) POWER PAK -MOUNT NEXT TO LIGHT FIXTURE OUTLET BOX OR AT PANELBOARD IF CEILING SPACE IS NOT ACCESSIBLE SLAVE PAK IF CONTROLLING MORE THAN ONE CIRCUIT ROOM LIGHT SWITCHES AS INDICATED ON PLANS TO ROOM LIGHT FIXTURES LIGHTING CIRCUIT HOT NEUTRAL SW-a SW-b SW-c SW-d D D D D - DIMMER WITH ON/OFF SWITCH 3 - INDICATES 3-WAY SWITCH NOTE: PROVIDE 0-10V SLIDE DIMMER WITH ON/OFF SWITCH PER LIGHT MANUFACTURER RECOMMENDATIONS. 46" . FLOOR HALLWAY SWITCH 3 CEILING 1/2" CONDUIT IN WALL LAVATORY (1) 4" SQUARE BOX -PROVIDE STEEL PLATE w/ 3/8" FLEX CONDUIT TO SOLENOID. 1/2" CONDUIT JUNCTION BOX EC TO PROVIDE 120V POWER TO TRANSFORMER (BY PC) MOUNTED ON JUNCTION BOX FLOOR LINE NOTES: · VERIFY BEST JUNCTION BOX LOCATION w/ PC AND OWNER'S MAINTENANCE STAFF. · EC SHALL PROVIDE ALL CONDUIT/BOXES AND MAKE FINAL CONNECTIONS. WIRING FURNISHED BY PC -CONNECT TO LOCAL RECEPTACLE CIRCUIT OR AS SHOWN ON PLANS. · SEE PLANS FOR PLUMBING FIXTURE LOCATIONS AND QUANTITIES. 2016 © EXCEL ENGINEERING, INC. SHEET INFORMATION SHEET NUMBER PROJECT INFORMATION PROJECT NUMBER PROFESSIONAL SEAL PRELIMINARY DATES NOT FOR CONSTRUCTION 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926‐9800 WWW.EXCELENGINEER.COM ARCHITECTS ● ENGINEERS ● SURVEYORS 2/1/2018 1:15:01 PM C:\Users\AndyL\Documents\Revit Local Files\1757840_Elec_Central_(rvt 2015)_AndyL.rvt ONELINE DIAGRAMS, SCHEDULES & DETAILS 1757840 TENANT BUILD‐OUT FOR: PROFILE BY SANFORD 11503 SPRING MILL RD, SUITE 700 ● CARMEL, IN 46032 JAN. 31, 2018 E4.0 E4.0 NOT TO SCALE 4 EXTERIOR LIGHTING CONTROL DETAIL E4.0 NOT TO SCALE 2 CONDUIT PENETRATION DETAILS E4.0 NOT TO SCALE 3 MOTION SENSOR DETAIL Total Est. Demand: 116 A Receptacle 14760 VA 83.88% 12380 VA Total Conn.: 112 A Other 3940 VA 100.00% 3940 VA Total Est. Demand: 41642 VA Motor 18512 VA 115.06% 21301 VA Total Conn. Load: 40429 VA Lighting 3217 VA 125.00% 4021 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps: 116 A 97 A 128 A Total Load: 13645 VA 11689 VA 15094 VA 41 -- -- -- -- 3718 2399 -- -- -- -- 42 39 -- -- -- -- 3718 2399 -- -- -- -- 40 37 MOTOR - RTAC-2 45 A 3 3718 2399 3 30 A MOTOR - RTAC-1 38 35 RECEPTACLE - WP/GFI RTAC-1 20 A 1 180 180 1 20 A RECEPTACLE - WP/GFI RTAC-2 36 33 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 34 31 MISC - WH-1 20 A 1 1500 0 1 20 A -- SPARE 32 29 OTHER - SIGNAGE 20 A 1 1200 1440 1 20 A RECEPTACLE - RETAIL FREEZER 30 27 RECEPTACLE - MICROWAVE 20 A 1 180 1440 1 20 A RECEPTACLE - BREAKROOM FREEZER 28 25 RECEPTACLE - CASH WRAP 20 A 1 180 720 1 20 A RECEPTACLE - WINDOW DISPLAY 26 23 RECEPTACLE - CASH WRAP 20 A 1 540 360 1 20 A RECEPTACLE - RETAIL BUFFET 24 21 RECEPTACLE - RETAIL BUFFET 20 A 1 180 720 1 20 A RECEPTACLE - CASH WRAP 22 19 RECEPTACLE - CONFERENCE 113 20 A 1 720 540 1 20 A RECEPTACLE - RETAIL / HALLWAY 20 17 RECEPTACLE - DATA ROOM 20 A 1 360 720 1 20 A RECEPTACLE - CONSULT 6 18 15 RECEPTACLE - E.W.C 20 A 1 180 720 1 20 A RECEPTACLE - CONSULT 5 16 13 RECEPTACLE - RESTROOMS 20 A 1 1600 720 1 20 A RECEPTACLE - CONSULT 4 14 11 RECEPTACLE - BREAK ROOM 20 A 1 900 720 1 20 A RECEPTACLE - CONSULT 3 12 9 RECEPTACLE - DATA RACK 20 A 1 180 720 1 20 A RECEPTACLE - CONSULT 2 10 7 RECEPTACLE - REFRIGERATOR 20 A 1 180 720 1 20 A RECEPTACLE - CONSULT 1 8 5 RECEPTACLE - CONFERENCE 113 20 A 1 540 1837 1 20 A LIGHTING - RETAIL 6 3 RECEPTACLE - DATA ROOM 20 A 1 360 892 1 20 A LIGHTING - BREAK ROOM / RESTROOMS / CONF. 4 1 LIGHTING - EXIT / NIGHT LIGHTS 20 A 1 40 608 1 20 A LIGHTING - CONSULT 101-107 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: SEE BANCH CIRCUIT FEEDER SCHEDULE FOR FEEDER DESIGNATIONS Enclosure: NEMA 1 MCB Rating: 200A Mounting: Recessed Wires: 4 Mains Rating: 225A Supply From: Phases: 3 Mains Type: MCB Location: BREAKROOM 114 Volts: 120/208 Wye A.I.C. Rating: PANELBOARD:A UTILITY E4.0 NOT TO SCALE 1 SOUND MASKING SPEAKER WIRING DIAGRAM EXISTING (RELOCATED) E4.0 NOT TO SCALE 5 SWITCHBANK DETAIL E4.0 NOT TO SCALE 7 INFRARED WATER CONTROL DETAIL 03/29/18 Nick Mishler