1757840 - Sheet - P4-0 - SCHEDULES
PIPE SCHEDULE COPPER PEX PVC CPVC C12200 PIPE FITTINGS JOINTS PIPE FITTINGSJOINTS PIPE FITTINGS JOINT PIPE FITTING JOINT ASTM B42, B88 TYPE L HARD DRAWN ASTM B42, B88 TYPE K SOFT ASTM B42, B280 HARD DRAWN ASME B16.15 CAST BRONZE THREADED (1) ASME B16.18 CAST COPPER SOLDER (1) ASME B16.18 OR B16.22 COPPER PRESS FITTINGS WITH EPDM O-RINGS (4) ASTM B-88 CDA 89833 CAST OR ASTM B-75 C12200 WROT COPPER ALLOY GROOVED FITTING. (5) ASME B16.22 WROUGHT COPPER SOLDER (2) LEAD FREE SOLDER ASTM B32 AWS A5.8 BCuP SILVER BRAZE COLD PRESS MECH. JOINT (4) COUPLING JOINT (5) (6) ASTM F876, F877, F2023 ASTM F2159 PER MFR REQUIREMENTS SCH. 40 PRESSURE RATED ASTM D1785 SCH. 40 PRESSURE RATED ASTM D1785 DWV NON-PRESS. RATED ASTM F891 SCH. 40 NON-PRESS. RATED ASTM D1784, D2665 SDR 35 NON-PRESS. ASTM D3034 SCH. 40 ASTM D 2466 SCH. 40 DWV ASTM D2665 SDR 35 ASTM D3034 ASTM F656 PRIMER, ASTM D2564 SOLVENT CEMENT ASTM F477 ELASTOMERIC GASKET SCHEDULE ASTM D2846 - SDR 11 ASTM D1784 CLASS 23447, F441 ASTM D1784, F2618 ASTM D1784, F439 SOLVENT CEMENT ASTM F493 SOLVENT CEMENT ASTM F493, NSF 14 PIPE SERVICE LOCATION SIZE WATER ABOVE GROUND ALL X X X X X X X X X X X X X X X X SANITARY ABOVE GROUND ALL X X X DRAIN AND VENT UNDER BUILDING ALL X X X X (1) LEAD-FREE DEZINCIFICATION-RESISTANT (DZR) BRASS ALLOY C87850 PER ASTM B584 (2) LEAD-FREE PER ASTM B75 ALLOY C12200 (4) INSTALL PER MANUFACTURER'S INSTRUCTIONS. 50 YEAR WARRANTY AGAINST MANUFACTURING DEFECTS. (5) INSTALL PER MANUFACTURER'S INSTRUCTIONS. 10 YEAR WARRANTY AGAINST MANUFACTURING DEFECTS. (6) GRINNELL FIG 672 OR EQUIVALENT. DUCTILE IRON ASTM A536 GRADE 65-45-11 HOUSING WITH COPPER ACRYLIC ENAMEL COATING, ZINC PLATED TRACK HEAD BOLTS CONFORMING TO ASTM A-183, GRADE "EN" EPDM (COPPER COLOR CODE) NSF 61 APPROVED COMPOUND GASKET SUITABLE FOR WATER TEMPERATURE. INSULATION SCHEDULE SERVICE LOCATION INSULATION INSULATION THICKNESS & TYPE (1) JACKET COLD WATER GENERAL BUILDING 1/2" RIGID F.G. OR ELAST. FOAM (10) NR COLD WATER IN WALLS 1/2" ELASTOMERIC FOAM NR COLD WATER (PEX AND CPVC) ALL NR NR HOT WATER MAIN GENERAL BUILDING 1" RIGID F.G. OR ELAST. FOAM (10) NR HOT WATER BRANCH IN WALLS 1/2" ELASTOMERIC FOAM NR NR = NOT REQUIRED INSULATION NOTES (1) WHERE INSULATION IS PROVIDED ON PIPING INSULATE METERS, VALVES, BACKFLOW PREVENTERS AND ALL INLINE EQUIPMENT. (10) INSULATION NOT REQUIRED FOR EXPOSED FINAL PIPING CONNECTIONS TO FIXTURES. 7.0 1.5 120 1 ELECTRICAL/STARTER/DISCONNECT SCHEDULE ELECTRICAL DATA STARTER DISCONNECT SYM. LOCATION HP KW AMPS VOLT PH. TYPE LOCATION FURN. ACCESS- DIS- FURN. REMARKS BY ORIES CONNECT BY EWC-1 SEE DWG - - 120 1 INTEG INTEGRAL EM - NR - REC. WH-1 SEE DWG - - INTEG INTEGRAL EM - R EC H.W. INFR WTR CONTROL (L-1) SEE SCHED - FRAC. - 120 1 - INTEGRAL EM - NR - H.W. (1) STARTER TYPE: INTEG.= INTEGRAL: PROVIDED INTEGRAL WITH EQUIPMENT. FURNISHED BY: ACCESSORIES: DISCONNECT: REMARKS: EM = EQUIPMENT MANUFACTURER HOA = HAND-OFF-AUTO NR= NOT REQUIRED H.W.= HARD WIRED PC = PLUMBING CONTRACTOR PL = PILOT LIGHT R = REQUIRED REC.=RECEPTACLE EC = ELECTRICAL CONTRACTOR PB = PUSH BUTTON WP= WEATHERPROOF HC = HEATING CONTRACTOR 2-SP = TWO SPEED F= FUSED RV = REDUCED VOLTAGE - ACCEPTABLE MANUFACTURERS: ALLEN BRADLEY, CUTLER HAMMER, SQUARE D, GENERAL ELECTRIC. - VERIFY VOLTAGE AND PHASE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING EQUIPMENT. (1) 120V TO 24V TRANSFORMER AND WIRING FROM TRANSFORMER TO VALVES BY PC. ELECTRIC WATER COOLER SCHEDULE (E.W.C.) CAP. BARRIER NUMBER RATED FULL NO. RECESS (GPH) FREE OF CONTROL WATTS LOAD MODEL REMARKS BASINS AMPS 1 NO 8.0 YES 1 FRONT/SIDE PUSHBAR 360 7.0 LZSG8WSLK "ELKAY" (1) - ACCEPTABLE MANUFACTURERS: ELKAY, HALSEY TAYLOR, OASIS, HAWS, FILTRINE. - PROVIDE WITH 1-1/4" WITH C.O. PLUG ("BRASSCRAFT" 0010BX), AND ANGLE WATER STOP WITH HANDLE ("BRASSCRAFT" OCR19Z C). - CAPACITY BASED ON 50 DEGREE F WATER IN AMBIENT TEMPERATURE OF 90 DEGREES F. - LEAD FREE CONSTRUCTION. (1) WALL MOUNTED, STAINLESS STEEL BASIN, VINYL CLAD CABINET W/ BOTTLE FILLER AND FILTER. 112 WATER HEATER SCHEDULE (W.H.) SIZE COMM. VOLTAGE/ REC. TANK NO. LOC. MOUNTING DIA. X HT. TANK KW PHASE AMPS GPH SIZE MODEL REMARKS WARR. GAL. 1 PLATFORM 18" x 25" 3 YR 1.5 120/1 12.6 6.2 19 LE120U3-1 "BRADFORD WHITE" - ACCEPTABLE MANUFACTURERS: BRADFORD WHITE, RHEEM, LOCHINVAR, STATE, BOCK. - RECOVERY BASED ON 100 DEGREE F TEMPERATURE RISE, GLASS LINING, 100 PSIG T&P RELIEF VALVE SETTING, 150 PSIG WORKING PRESSURE. (1) EXPANSION TANK SCHEDULE (E.T.) TANK CONN. TANK ACCEPT. PRECHARGE WORKING WEIGHT NO. MOUNTING TYPE SIZE CAP. CAPACITY PRESSURE PRESS DIA. HEIGHT FILLED MODEL REMARKS (GAL.) (GAL.) (PSIG) (PSIG) (LBS.) 1 PIPE DIAPHRAGM 3/4" 2.1 0.9 150 8" 11.6" 14 PH 5 "FLEXCON" - ACCEPTABLE MANUFACTURERS: FLEXCON, AMTROL, WESSELS. (1) VERIFY WATER PRESSURE PRIOR TO INSTALLATION. SET PRECHARGE PRESSURE TO STATIC PRESSURE IN STREET. (2) PROVIDE ONE "DELTA" 060704A BOX MOUNT 120VAC TO 20 VAC TRAMSFORMER FOR UP TO FIVE FAUCETS. PROVIDE ONE "DELTA" 060974A CONVERTER FOR HARDWIRE SUPPLY FOR EACH FAUCET. PROVIDED WITH INTEGRAL THERMOSTATIC MIXING VALVE. LAVATORY SCHEDULE (L.) OVERALL FAUCET LAV DRAIN SUPPLY STOP FAUCET NO. MOUNTING SIZE CENTERS MODEL TYPE MODEL TYPE MODEL TYPE GPM MODEL 1 UNDER MOUNT (4) SINGLE (3) (4) OFFSET GRID K-7131-A KEY BRASSCRAFT SCR1912AX C SENSOR 0.5 (4)(2) - ACCEPTABLE MANUFACTURERS: -DRAINS AND TRAPS: KOHLER, DEARBORN, KEENEY, MCGUIRE, BRASSCRAFT. -STOPS AND SUPPLIES: KOHLER, BRASSCRAFT, DEARBORN, KEENEY, MCGUIRE. - ALL MODEL NUMBERS BASED ON KOHLER UNLESS INDICATED OTHERWISE. - VITREOUS CHINA LAVS, 1-1/4" "P" TRAP WITH CLEANOUT PLUG (BRASSCRAFT 0010), BUSHING ON END OF OUTLET TUBE, WALL FLANGE. - ALL WETTED PARTS SHALL BE LEAD FREE COMPLIANT. - FAUCETS WITH VANDAL RESISTANT AERATOR. (3) COORDINATE SINK CUTOUT SIZE AND FAUCET HOLE DRILLING WITH G.C.. (4) FURNISHED BY SYMPATECO. INSTALLED BY P.C. SERVICE SINK SCHEDULE (S.S.) BASIN FAUCET NO. MOUNTING MAT'L SIZE RIM MODEL PIPING BACKFLOW GPM MFR/MODEL GUARD EXPOSURE PREVENTER 1 FLOOR DURASTONE 24x24x10 (1) MUSTEE 63M CONCEALED WATTS SERIES 8 5-7 CHICAGO 305 - ACCEPTABLE MANUFACTURERS: -BASIN: MUSTEE, FIAT, KOHLER, WILLIAMS. -FAUCET: CHICAGO, DELTA, KOHLER, AMERICAN STANDARD, SYMMONS. T&S BRASS. -DRAINS AND TRAPS: KOHLER, DEARBORN, KEENEY, MCGUIRE, BRASSCRAFT. - FLOOR SERVICE SINKS WITH 3" BRASS DRAIN, STAINLESS STEEL 3 MOP HOLDER HANGER, HEAVY DUTY 5/8" DIAMETER REINFORCED RUBBER HOSE, AND STAINLESS STEEL HOSE BRACKET. (1) BUMPER GUARDS ON EXPOSED RIMS. SINK SCHEDULE (S.) SINK FAUCET NO. COMPARTMENT OVERALL MODEL NO. SPOUT GPM HANDLE FINISH SPRAY MODEL NO. DEPTH SIZE HOLES REACH HEIGHT 1 1 10.125" 22"x19.5" ELKAY DLR221910PD (1) 1 9.25" 8.9" 1.8 LEVER STAINLESS YES KRAUS KPF-2630 (1) - ACCEPTABLE MANUFACTURERS: -STOPS AND SUPPLIES: KOHLER, BRASSCRAFT, DEARBORN, KEENEY, MCGUIRE. -DRAINS AND TRAPS: KOHLER, DEARBORN, KEENEY, MCGUIRE, BRASSCRAFT. - SELF-RIMMING 18 GA. 304 S.S. SINK, ANGLE SUPPLIES WITH HANDLE STOPS (BRASSCRAFT OCR1912AX C). PROVIDE EACH COMPARTMENT WITH STAINLESS STEEL STRAINER AND TAILPIECE (ELKAY LKPD1), AND 1-1/2" "P" TRAP (BRASSCRAFT 0030). - VERIFY SINK CUTOUT SIZE WILL FIT IN COUNTERTOP WITH CABINET SHOP DRAWINGS PRIOR TO ORDERING. (1) SINK AND FAUCET FURNISHED BY SYMPATECO. INSTALLED BY P.C. 1/2" 1/2" THERMOSTATIC MIXING VALVE SCHEDULE (T.M.V.) MAX. ACTUAL ACT. TEMP. NO. SERVICE INLETS OUTLET FLOW FLOW P.D. SETTING MODEL REMARKS (GPM) (GPM) (PSI) (°F) 1 LAVATORY 14.0 2.0 4 105 LFMMV "WATTS" (2) - ACCEPTABLE MANUFACTURERS: SYMMONS, WATTS, POWERS. - LEAD FREE BODY, REMOVABLE CARTRIDGE WITH STRAINER, STAINLESS STEEL SPRING, EPDM O-RINGS AND SOLID WAX THERMOSTAT ASSEMBLY. - P.C. SHALL FIELD ADJUST TMV TO TEMPERATURE SETTING INDICATED IN SCHEDULE. (2) POINT OF USE TMV SHALL COMPLY WITH ASSE 1017, 1069 AND 1070. WATER CLOSET SCHEDULE (W.C.) MIN. ACTUAL MIN. FLUSH BOWL FLUSH VALVE FLUSH VALVE/ NO. MT'G MaP MaP PRESS. TYPE GPF MFR/MODEL RIM HT. PIPING TYPE SUPPLY STOP SEAT (1) (1) PSIG A.F.F. CONNECTION MFR/MODEL 1H FLOOR 800 1000 8 TANK 1.28 KOHLER K-3609 16-1/2" LOOSE KEY STOP - BRASSCRAFT SCR1912AX C BEMIS 1655 SSCT - ACCEPTABLE MANUFACTURERS: -BOWL: TOTO, KOHLER, AMERICAN STANDARD, CRANE, ELJER, MANSFIELD. -SUPPLY STOPS: BRASSCRAFT, CHICAGO, KOHLER, DEARBORN, KEENEY, MCGUIRE. -SEAT: TOTO, KOHLER, BEMIS, SPERZEL, OLSONITE, AMERICAN STANDARD, CHURCH. - TANK WATER CLOSETS: CLOSE-COUPLED WITH VITREOUS CHINA TANK AND COVER, FLUSH ASSEMBLY, ANGLE SUPPLY, AND TANK INSULINER. - FLOOR SET WATER CLOSETS WITH BOLT CAPS. - CONTROLS FOR ADA ACCESSIBLE FIXTURES SHALL BE ON THE OPEN SIDE. (1) MAXIMUM PERFORMANCE (MaP) RATING PER VERITEC CONSULTING INC. AND KOELLER AND COMPANY. PROVIDE MaP RATING INFORMATION WITH PRODUCT SUBMITTAL. CLEANOUT SCHEDULE BODY PLUG ACCESS COVER NO. LOCATION SIZES MAT'L MAT'L MAT'L MISC. MISC. FIGURE REMARKS CO ABV. CLGS & EXPOSED PIPE 2" - 6" (1) PVC - - - (1) (1) FCO FINISHED ROOMS W/O CARPET (2) 2" - 6" C.I. PVC N.B. - - Z-1400 "ZURN" FCO FINISHED ROOMS WITH CARPET (2) 2" - 6" C.I. PVC N.B. CARPET MARKER - Z-1400-CM "ZURN" WCO WALL 2" - 6" (6) POLY S.S. - - Z-1469 "ZURN" - ACCEPTABLE MANUFACTURERS: J.R. SMITH, SCHIER, JOSAM, WADE, ZURN. - RECESSED TAPER THREAD PLUG WITH SLOTTED RECESS. (1) PROVIDE THREADED FEMALE ADAPTER WITH INTERNAL PLUG. ADAPTER MATERIAL SHALL MATCH PIPE MATERIAL TO WHICH CO IS BEING CONNECTED. (2) FINISHED ROOMS ARE ROOMS WITH CARPET OR FLOOR TILE OR ROOMS ACCESSIBLE BY A DOOR LESS THAN 42" WIDE. (6) PROVIDE TEST/CLEANOUT TEE. THREADED PLUG WITH BRASS INSERT. MATERIAL SHALL MATCH PIPE MATERIAL TO WHICH TEE IS BEING CONNECTED. DRAIN SCHEDULE OUTLET BODY STRAINER/TOP SYM. TYPE APPLICATION SIZE MAT'L MAT'L SIZE MISC. MODEL REMARKS FD-1 FLOOR PEDESTRIAN TRAFFIC 2"-3" (2) CAST IRON N. B. "TYPE B" 5" DIA - ZN-415-5B "ZURN" - ACCEPTABLE MANUFACTURERS: ZURN, J.R. SMITH, JOSAM, WADE, WATTS, SCHIER, KUSEL, SIOUX CHIEF. (2) AS NOTED ON DRAWINGS 2017 © EXCEL ENGINEERING, INC. SHEET INFORMATION SHEET NUMBER PROJECT INFORMATION PROJECT NUMBER PROFESSIONAL SEAL PRELIMINARY DATES NOT FOR CONSTRUCTION 100 CAMELOT DRIVE FOND DU LAC, WI 54935 PHONE: (920) 926-9800 WWW.EXCELENGINEER.COM ARCHITECTS ● ENGINEERS ● SURVEYORS 2/1/2018 3:34:43 PM C:\Users\TonyC\Documents\1757840_Plbg_Central_(rvt 2015)_tony.cGCK3T.rvt SCHEDULES 1757840 TENANT BUILD-OUT FOR: PROFILE BY SANFORD 11503 SPRING MILL RD, SUITE 700 ● CARMEL, IN 46032 JAN. 31, 2018 P4.0 03/29/18 Nick Mishler