HomeMy WebLinkAboutM002.0AToe Nailed
er
LG3
XB
XB1
RG
XG
TBT2T3BRG1
MB
MGPBP1 P4BLBRG2ABVF4VX1
VX3
VX4
VM
VM1
VM2
VM3
VR1
VR2
VR3
VR4
VR5
VR6
VX2VX5
JUS26JUS26JUS28
JUS26JUS26JUS26JUS26JUS28
JUS26
JUS26JUS28JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS28JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26JUS26UndesignedUndesignedUndesignedUndesignedX(2)T(3)T1(2)
P(4) P2(4)P3(3)
P4(3)
L(3)
L1(3)R(9)R1(2)J1(2)FJ(4)T3(10)1-06-002-00-00
2-00-00
1-09-00
2-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-01-1210-042-00-002-00-001-09-122-01-082-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-001-08-082-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-002-00-002-00-002-00-002-00-001-11-082-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-09-121-10-082-00-002-00-002-00-002-00-002-00-001-00-082-00-002-00-002-00-002-00-00CJ1CJ1Undesigned
Undesigned
Order #: 18020075
The Grove at Legacy - 22A
7217 Antiquity Drive
Carmel, Indiana 46033
Carter Lumber
2901 N. Morton St.
Franklin, Indiana 46131
(317) 346-1300
THIS IS A TRUSS PLACEMENT DIAGRAM ONLY.These trusses are designed as individual building components to be incorporated
into the building design at the specification of the buildingdesigner. Seeindividualdesignsheetsforeachtrussdesign identified onthe placement drawing. The building designer is responsiblefortemporaryandpermanentbracingoftheroofandfloorsystem andfor the overall structure. The design of the truss support structure including headers, beams, walls, and columns is the responsibility of
the building designer. For general guidance regarding bracing, consult "Bracing of Wood Trusses" available from the Truss PlateInstitute, 583 D'Onifrio Drive; Madison, WI 53179.
SHOP DRAWING APPROVALTHIS LAYOUT IS THE SOLE SOURCE FOR FABRICATION OF TRUSSES AND VOIDS ALL PREVIOUS ARCHITECTURAL OROTHER TRUSS LAYOUTS. REVIEW AND APPROVAL OF THIS LAYOUT MUST BE RECEIVED BEFORE ANY TRUSSES WILL
BE BUILT. VERIFY ALL CONDITIONS TO INSURE AGAINST CHANGES THAT WILL RESULT IN EXTRA CHARGES TO YOU.
REVIEWED BY:__________________________ APPROVED BY:______________________________ DATE:___________
Pyatt Builders
Scale: NTS Drawn By: K. BronnenbergDate: 3/6/18
Model
Sausalito
Notes:
1) Valley trusses are designed to sit on sheathing.
2) Installation of all temporary and permanent braces is essential.
See truss drawings, BCSI-1 Building Component Safety information
and building designers requirements.
3) Provide solid bearing for beams and girders. See Code and/or
building deigners requirements.
4) Truss are NOT designed to be field modified unless noted
otherwise. If any alterations are to be considered ALWAYS consult
aqualifiedtrussdesignerorengineerBEFOREmakinganyalterations.
5) Add/remove overhangs as needed.
Multi-Ply Girder Truss:
See drawing of multi-ply girders for fastening pattern to connect plys
so they act as one. All plys must be fastened together before supported
trusses or framing is attached to girders.
Hangers:
Install all hangers per manufacturers requirements.