Loading...
HomeMy WebLinkAboutA.0001 (Architectural)PROJECT NAME AND LOCATION : no. distribution date A project no: dwg no: no. revision date ISSUE DATE 12.21.17 1 B SUBMITTAL DATE THIS DRAWING AND ITS CONTENTS ARE CONSIDERED INSTRUMENTS OF SERVICE. AS SUCH THEY ARE COPYRIGHTED PROPERTY OF RUN RUN DESIGN, LLC. THE USE OF THESE DRAWINGS ARE LIMITED TO THIS SPECIFIC PROJECT AND ARE NOT TO BE OTHERWISE REPRODUCED IN ANY WAY OR USED FOR SUPPLEMENTAL LOCATIONS WITHOUT WRITTEN PERMISSION FROM RUN RUN DESIGN, LLC. SHEET NAME: DRAWING REVISIONS: STORE #791 4335 W. 106TH STREET UNIT #1200 CARMEL, IN 48032 12.22.17 STATE COMMENTS 01.11.18 2 3 STATE COMMENTS 02.14.18 17-085 STATE COMMENTS 01.30.18 TITLE SHEET A1.0 GENERAL CONTRACTOR NOTE: THE GC MUST SUBMIT SEPARATE DRAWINGS FOR SPRINKLER AND FIRE ALARM WORK AND SHALL BE UNDER SEPARATE PERMIT - WHEN APPLICABLE. MILLWORK: MIDWEST CABINET CO., INC. ATTN: SCOTT TETER 1674 INDUSTRIAL AVE. OTTAWA, KS 66067 P: 918.681.0643 steter@midwestcabinet.com METAL WORKS: NICHOLSON METAL WORKS ATTN: VICTOR NICHOLSON 5112 MERCANTILE ROW DALLAS, TX 75247 P: 214.920.3654 nicholsonmetalfab@sbcglobal.net KITCHEN/EQUIPMENT ISI COMMERCIAL REFRIGERATION ATTN: CHRIS MORQUECHO 9136 VISCOUNT ROW DALLAS, TX 75247 P: 469.240.7258 cmorquecho@isi-texas.com FURNITURE: WILDWOOD MARKETING ATTN: EMILEE KELLAR 455 BOSAL WAY LAVONIA, GA 30553 P: 706.356.2000 emilee@wildwoodmarketing.net TILE: CMC NATIONAL ACCOUNTS ATTN: ERIKA FRETTO ONE WASHINGTON SQUARE ALBANY, NY 12205 P: 518.713.5389 efretto@creativematerialscorp.com whichwichtile@creativematerialscorp.com LIGHTING: VILLA LIGHTING SUPPLY ATTN: DEREK VICKROY 2929 CHOUTEAU AVENUE ST. LOUIS, MO 63103 P: 314.633.0654 derek.vickroy@villalighting.com SIGN VENDOR: 1 STOP SIGNS ATTN: GARY GILL 500 N. 56TH STREET CHANDLER, AZ 85226 P: 480.961.7446 garry@1stopsigns.com GENERAL REQUIREMENTS: A. DRAWINGS. THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL SCOPE OF WORK. CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS AND ALERT ARCHITECT TO ANY UNFORESEEN CONSTRUCTION DIFFICULTIES BEFORE BEGINNING WORK. IN-FIELD REVISIONS SHALL NOT OCCUR WITHOUT ARCHITECT'S APPROVAL. B. PRE-CONSTRUCTION MEETING. PRIOR TO ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY, THE CONTRACTOR SHALL SCHEDULE, WITH OWNERS APPROVAL, A PRE-CONSTRUCTION MEETING WITH THE LOCAL BUILDING DEPT. OR LOCAL PUBLIC WORKS DEPT. VERIFY WHICH AGENCY WOULD BE INVOLVED. THE CONTRACTOR SHALL PROVIDE LOCAL INSPECTOR WITH 24 HOURS NOTICE PRIOR TO INSPECTION . C. TYPICAL WALL SECTIONS, FINISHES, AND DETAILS ARE NOT INDICATED EVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS AND SECTIONS. REFER TO DETAILED DRAWINGS. CONTRACTOR TO PROVIDE AS IF DRAWN IN FULL. D. CODES / PERMITS / REGULATIONS. ALL EXTERIOR SIGNAGE MUST BE SUBMITTED AND REVIEWED UNDER SEPARATE PERMIT APPLICATION. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS NECESSARY OTHER THAN THE BUILDING PERMIT. CONTRACTOR SHALL ALSO PAY FOR ALL OTHER CHARGES, FEES OR COSTS CHARGED BY THE BUILDING AND CONSTRUCTION DEPARTMENTS, UTILITY AGENCIES OR PRIVATE COMPANIES WHICH REQUIRE SUCH COSTS FOR OR PRIOR TO INSTALLATIONS. NOTHING IN THE DRAWINGS SHALL BE CONSTRUCTED TO PERMIT AN INSTALLATION IN VIOLATION OF APPLICABLE CODES AND/OR RESTRICTIONS. SHOULD ANY CHANGE IN THE DRAWINGS BE NECESSARY IN ORDER TO COMPLY WITH APPLICABLE CODES AND/OR REQUIREMENTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AT ONCE AND CEASE WORK. ALL PARTS PERFORMED UNDER THIS CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES, REGULATIONS, RESTRICTIONS, REQUIREMENTS AND CODES. AMENDED BY GOVERNING CITY & ALL JURISDICTION RULES AND REGULATIONS. E. DIMENSIONS ARE SHOWN TO FACE OF MASONRY OR CENTERLINE OF OPENING, UNLESS DETAILED OTHERWISE ON DRAWINGS. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. THE CONTRACTOR SHALL VERIFY ALL ROUGH-IN DIMENSIONS FOR THE EQUIPMENT FURNISHED AND INSTALLED BY HIMSELF/HERSELF OR OTHERS. THE CONTRACTOR SHALL CONSULT THE PLANS OF ALL TRADES FOR OPENINGS THROUGH SLABS, WALLS, CEILINGS AND ROOFS. F. SHOP DRAWINGS REVIEW. PROVIDE SHOP DRAWINGS FOR THE ARCHITECTS/OWNERS AND AS REQUIRED BY THE CITY PRIOR TO CONSTRUCTION. G. CONTRACTOR TO FRAME OPENINGS IN WALLS, CEILINGS AND FLOORS FOR H.V.A.C. AND OTHER MECHANICAL OR ELECTRICAL WORK WHERE REQUIRED AND NOT OTHERWISE SHOWN ON THE PLANS. H. COMPLY WITH APPLICABLE REGULATIONS FOR BARRIER-FREE FACILITIES INCLUDING: 1). MAXIMUM THRESHOLD HEIGHT TO BE ONE HALF INCH (1/2") ALONG ACCESSIBLE ROUTE OF TRAVEL. 2). STAIR NOSINGS TO BE FLUSH, SLIP RESISTANT AND ROUNDED TO RADIUS OF ONE HALF INCH (1/2")MAXIMUM. DOORS/WINDOWS: A. GLAZING. PROVIDE GLAZING PER CITY CODES: INSULATED UNITS SHALL BE CLASS 40 GLAZING WITH LOW ARGON GAS. GLAZING IN LOCATIONS SUBJECT TO HUMAN IMPACT SUCH AS PANES IN DOORS, GLAZING WITHIN A 24" ARC OF A DOOR OPENING, GLAZING WITHIN 18" OF THE FLOOR (AND IS OVER 9 SQ. FT. PER PANEL) SHALL BE TEMPERED GLASS OR LAMINATED SAFETY GLASS PER CODE. GLAZING U-VALUE (AMMA TESTED) U-40 MAXIMUM. FIRE PROTECTION: A. GC TO EXTEND THE EXISTING AUTOMATIC FIRE SPRINKLER SYSTEM AS REQUIRED. GET SYSTEM DESIGN APPROVED BY GOVERNING CITY'S BUILDING DEPARTMENT AND FIRE DEPARTMENT PRIOR TO INSTALLATION (IF APPLICABLE). B. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY INTERNATIONAL BUILDING CODE AND LOCATE PER FIRE MARSHAL'S DIRECTION. 1 FIRE EXTINGUISHER PER 3,000 S.F. OF BUILDING AREA WITHIN 75'-0" TRAVEL DISTANCE BETWEEN EXTINGUISHERS. C. MAINTAIN STRUCTURAL AND FIRE RESISTIVE INTEGRITY AT EXTERIOR AND RATED INTERIOR WALL PENETRATIONS FOR ELECTRICAL, MECHANICAL, PLUMBING AND COMMUNICATIONS CONDUITS, PIPED AND SIMILAR SYSTEMS PER CITY'S CODE. THERMAL/MOISTURE PROTECTION: A. OPENINGS. ALL OPENINGS TO BE CAULKED, SEALED OR WEATHER-STRIPPED. ALL FLASHING AND ARCHITECTURAL SHEET METAL TO BE 24 GAUGE GALVANIZED STEEL, FACTORY PRIMED AND FIELD PAINTED. 10'-0" LENGTHS, PER SMACNA MANUAL UNLESS OTHERWISE NOTED. B. CAULKING AND SEALANTS. USE PRIMERS AS REQUIRED BY MANUFACTURER. BACKING RODS OR TAPE AS RECOMMENDED BY MANUFACTURER. USE POLYURETHANE SEALANTS AT CONCRETE FLOOR AND SIDEWALK JOINTS. ALL OTHER LOCATIONS USE POLYSULFIDE OR SILICONE. C. VAPOR BARRIERS. CONTINUOUS APPROVED VAPOR BARRIERS SHALL BE INSTALLED ON THE HEATED SIDE OF ALL THERMAL INSULATION INSTALLED. D. INSULATION. PROVIDE INSULATION PER LOCAL CODE, COMPONENT PERFORMANCE APPROACH. GENERAL NOTES: 1. PRIOR TO DEMOLITION, VERIFY IN FIELD EXISTING WALLS AND IF ANY STRUCTURAL COLUMNS EXIST. IF SO, CONTACT ARCHITECT IMMEDIATELY. 2. CONTRACTOR TO MAINTAIN PROPER LIGHTING, SANITATION AND VENTILATION AT ALL TIMES. 3. ALL WORK MUST BE APPROVED BY BUILDING INSPECTOR PRIOR TO COVERING WORK. 4. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN A WATER AND WEATHER TIGHT BUILDING. 5. ALL WORK TO BE PERFORMED TO CODE BY LICENSE CONTRACTORS PERFORMING WORK IN THEIR SPECIFIC TRADE ONLY. 6. ALL DESIGN, DRAWINGS, AND DETAILS REPRESENT COMPLETE WORK IN PLACE. ARCHITECT SHALL HAVE NO CONTROL OR CHANGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION. 7. INTERIOR PARTITIONS NOTED ON PLANS MAY BE SHOWN AS NOMINAL DIMENSIONS, SUCH AS 5" INTERIOR WALL REFERS TO GYPSUM BOARD EACH OVER 3-5/8" STUDS. STUD SPACING IS 24" O.C. 8. ALL DEBRIS GENERATED FROM CONSTRUCTION MUST BE KEPT ON THE SITE IN EITHER AN ENCLOSED AREA OR HAULED AWAY DAILY, AND DISPOSED OF LEGALLY OFF-SITE. 9. EXTERIOR SIGNAGE IS NOT PART OF THIS CONTRACT OR PERMIT EXCEPT ELECTRICAL ROUGH-IN AND BLOCKING. SIGN CONTRACTOR SHALL MAKE SEPARATE SUBMITTAL TO THE CITY FOR REVIEW AND PERMIT. 10. KEEP ALL PIPING AND CONDUIT AS CLOSE TO WALLS AND ROOF DECK AS POSSIBLE AND ALL DUCTWORK AS CLOSE TO ROOF AS POSSIBLE. WHERE EXPOSED, ALL PIPING CONDUIT AND DUCTWORK SHALL BE PAINTED UNLESS NOTED. ALL PIPING CONDUIT SHALL BE ORGANIZED IN A NEAT MANNER RUNNING PARALLEL OR PERPENDICULAR TO ROOF FRAMING MEMBERS. 11. MAXIMUM FLAME SPREAD CLASSIFICATION OF FINISH MATERIALS USED ON INTERIOR WALLS AND CEILING SHALL NOT EXCEED THAT SET FORTH IN FLAME SPREAD TABLE OF THE BUILDING CODE. 12. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO CONSTRUCTION AND COORDINATE WITH ARCHITECT ANY CONFLICTS WITH THE PLANS. 13. PERFORM THE REMOVAL, CUTTING, AND DRILLING WITH THE CARE USE OF THE SMALLEST TOOLS SO AS TO NOT DAMAGE THE STRUCTURAL INTEGRITY OF THE BUILDING. 14. TO SAW CUT AT EXISTING RESTROOM LOCATION, USE SAWS AND COREDRILLS. DO NOT USE JACKHAMMER UNDER ANY CIRCUMSTANCES. 15. GC TO COORDINATE FIRE ALARM INSTALL WITH LANDLORD, IF REQUIRED BY CITY. ACP ACOUSTICAL CLG. PANEL ACT ACOUSTICAL CLG. TILE AL ALUMINUM ALUM ALUMINUM ARCH ARCHITECTURAL AVG AVERAGE BLDG BUILDING BLKG BLOCKING BR BRICK CMU CONCRETE BLOCK CT CERAMIC TILE CFM CUBIC FEET PER MINUTE CL CENTER LINE CLG CEILING CONC CONCRETE CONT CONTINUOUS CW COLD WATER DTL DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DR DOOR DS DOWNSPOUT DWG DRAWING EA EACH ELEV ELEVATION EXIST EXISTING OR EX EXT EXTERIOR FDN FOUNDATION FIN FINISH FD FLOOR DRAIN FL FLOOR FLASH FLASHING FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR FO FINISH OPENING FRP FIBERGLASS REINFORCED PANELS FRT FIRE RETARDANT TREATED GA GAUGE GALV GALVANIZED GL GLASS GWB GYPSUM WALLBOARD HDWE HARDWARE HM HOLLOW METAL HOR HORIZONTAL HT HEIGHT HW HOT WATER HWH HOT WATER HEATER HWT HOT WATER TANK LAV LAVATORY LT LIGHT MAT'L MATERIAL MAX MAXIMUM MTL METAL MIN MINIMUM MO MASONRY OPENING MUL MULLION N/A NOT APPLICABLE NIC NOT IN THIS CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIMENSION PT PAINT PLAM PLASTIC LAMINATE PLYWD PLYWOOD R RISER, RADIUS REBAR REINFORCING BAR REF REFERENCE REV REVISION RM, RMS ROOM, ROOMS RO ROUGH OPENING S & V SATIN AND VARNISH SC SOLID CORE SCHED SCHEDULE SEC SECTION SHT SHEET SPECS SPECIFICATIONS SF SQUARE FEET ST STEEL STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SV SHEET VINYL SS STAINLESS STEEL TB TELEPHONE MOUNTING BOARD TD TRENCH DRAIN THRESH THRESHOLD TYP TYPICAL UNFIN UNFINISHED UR URINAL VCT VINYL COMPOSITION TILE VERT VERTICAL VST VINYL SAFETY TILE W WIDTH WC WATER CLOSET WD WOOD WDW WINDOW WP WATERPROOF PLUMBING FIXTURES: HJC/ZIRM ATTN: CHRISTINE MCALEXANDER 310 SW 24TH STREET BENTONVILLE, AR 72712 P: 800.459.7099 whichwich@hjcinc.com DOOR TAG ROOM TAG DETAIL REFERENCE REVISION INTERIOR ELEVATION WALL SECTION EQUIPMENT REFERENCE GENERAL NOTES A TENANT IMPROVEMENT FOR STORE #791 4335 W. 106TH STREET UNIT #1200 CARMEL, IN 48032 PROJECT DATA A1.0 TITLE SHEET A1.1 RESPONSIBILITY SCHEDULES A1.2 DEMOLITION PLAN A2.0 FLOOR PLAN A3.0 REFLECTED CEILING PLAN A4.0 ELEVATIONS A4.1 ELEVATIONS A5.0 EQUIPMENT PLAN A6.0 DETAILS M0 MECHANICAL COMCHECK COMPLIANCE M1 MECHANICAL FLOOR PLAN & SCHEDULES M2 MECHANICAL & EXHAUST PLENUM DETAILS M3 MECHANICAL SPECIFICATIONS P1 PLUMBING SCHEDULES & NOTES P2 PLUMBING FLOOR PLANS P3 PLUMBING DETAILS P4 PLUMBING RISER DIAGRAMS P5 PLUMBING SPECIFICATIONS E0.0 ELECTRICAL SPECIFICATIONS & COMCHECK E1.0 LIGHTING FLOOR PLAN E2.0 POWER FLOOR PLAN E2.1 MECHANICAL POWER FLOOR PLAN E3.0 ONE-LINE DIAGRAM AND PANEL SCHEDULES SCOPE OF WORK: EXISTING VACANT SPACE TO BE REMODELED TO WHICH WICH SPECIFICATIONS. NEW EQUIPMENT, INTERIOR PARTITIONS, NEW PLUMBING, MECHANICAL, AND ELECTRICAL WORK. PREVIOUS TENANT WAS GREEN APPLE ACTIVE LIFESTYLE BOUTIQUE. PROJECT NAME: WHICH WICH PROJECT ADDRESS: 4335 W. 106TH STREET UNIT #1200 CARMEL, IN 48032 LOCAL JURISDICTION: BUILDING & SAFETY - CITY OF CARMEL HEALTH - HAMILTON COUNTY CODES UTILIZED: 2014 INDIANA BUILDING CODE (2012 IBC W/ INDIANA AMENDMENTS) 2009 ANSI A117.1 2012 INDIANA PLUMBING CODE 2009 INDIANA ELECTRICAL CODE (2008 NFPA 70 W/ INDIANA AMENDMENTS) 2014 INDIANA MECHANICAL CODE (2012 IMC W/ INDIANA AMENDMENTS) 2010 IECC (2007 ASHRAE 90.1 W/ INDIANA AMENDMENTS) 2014 INDIANA FIRE CODE (2012 IFC W/ INDIANA AMENDMENTS) 2014 INDIANA FUEL GAS CODE (2012 IFGC W/ INDIANA AMENDMENTS) PROPOSED USE: RESTAURANT CONSTRUCTION TYPE: II-B (NON-SPRINKLERED) OCCUPANCY GROUP: A-2 TOTAL S.F.: 1,597 S.F. QUEUING AREA (STANDING SPACE) 74 S.F. / 7 = 11 DINING AREA 570 S.F. / 15 = 38 KITCHEN/SERVICE AREA 624 S.F. / 200 = 3 HALLWAY/RESTROOM 329 S.F. / 0 = 0 TOTAL OCCUPANT LOAD: 52 2 EXIT(S) REQUIRED, 2 EXIT(S) PROVIDED (OCCUPANT LOAD > 50) 2 RESTROOM(S) REQUIRED, 2 RESTROOM(S) PROVIDED (OCCUPANT LOAD > 15) NO STRUCTURAL WORK IS TO BE PERFORMED UNDER THIS PERMIT. NO SITE WORK IS TO BE PERFORMED UNDER THIS PERMIT. (3) EMPLOYEES MAXIMUM EXTERIOR SIGN UNDER SEPARATE PERMIT BY SIGN COMPANY - INSTALLED BY SIGN COMPANY INDEX OF SHEETS SITE MAP PROJECT TEAM DIRECTORY PROJECT MANAGER: RUN RUN DESIGN, LLC. ATTN: STEPHANIE HENSCHEN 3334 N. 20TH STREET PHOENIX, AZ 85016 P: 480.221.0851 stephanie@runrundesign.com CORPORATE INFORMATION: WHICH WICH FRANCHISE, INC. (WWFI) ATTN: DAVID THOMPSON DIRECTOR OF CONSTRUCTION 1412 MAIN STREET, SUITE #2000 DALLAS, TX 75202 P: 214.747.9424 construction@whichwich.com TENANT INFORMATION: LEE KLEINER & BRIAN KAHN JANES RESTAURANT GROUP, INC. 1389 W. 86TH STREET, SUITE #300 INDIANAPOLIS, IN 46260 P: 317.413.3132 lkleiner@whichwich.net bkahn@whichwich.net BUILDING DEPARTMENT: CITY OF CARMEL BUILDING AND CODE SERVICES ONE CIVIC SQUARE CARMEL, IN 46032 P: 317.571.2444 HEALTH DEPARTMENT: HAMILTON COUNTY 18030 FOUNDATION DRIVE, SUITE A NOBLESVILLE, IN 46060 LANDLORD: MICHELLE LITTLE VERITAS REALTY 6440 WESTFIELD BOULEVARD INDIANAPOLIS, IN 46220 P: 317.789.8168 MLittle@VeritasRealty.com VENDOR INFORMATION REFERENCE SYMBOLS XXX XX X/XX.X X X XX X XX.X - XX WALL REFERENCE ABBREVIATIONS VICINITY MAP SCALE: NORTH SITE MAP 1 N.T.S. EXISTING ACCESSIBLE PARKING PROJECT LOCATION PROJECT LOCATION ACCESSIBLE PATH OF TRAVEL I HEREBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS ARE THE EXACT DUPLICATES OF THOSE SUBMITTED TO THE STATE. STEPHANIE HENSCHEN, PROJECT MANAGER, RUN RUN DESIGN 03/02/2018 03/19/18 Nick Mishler