HomeMy WebLinkAboutA.0003 (Architectural)1 (E) 3'-0" (E) 32'-0" (E) 32'-4" (E) 11'-4" (E) 2'-10" (E) 21'-8" (E) 7'-7" (E) 45'-8" (E) 9'-0" (E) 19'-7" (E) 3'-8" (E) 4'-1" T (E) 11'-9" (E) 3'-2" (E) 7'-8" (E) 2'-1" (E) 3'-8" (E) 15'-7" 3 6 1 2 7 11 10 8 9 2 2 2 2 4 4 4 4 4 5 6 11 10 8 9 NOTE: GC TO FIELD VERIFY EXISTING CONDITIONS & CONFIRM RESPONSIBILITY OF ANY SLAB WORK OR INTERIOR DEMISING WALLS PROVIDED BY TENANT NOTE: GC TO VERIFY IF ANY STRUCTURAL COLUMNS EXIST WITHIN SPACE DURING INITIAL WALK THRU NOTIFY ARCHITECT IMMEDIATELY. PROJECT NAME AND LOCATION : no. distribution date A project no: dwg no: no. revision date ISSUE DATE 12.21.17 1 B SUBMITTAL DATE THIS DRAWING AND ITS CONTENTS ARE CONSIDERED INSTRUMENTS OF SERVICE. AS SUCH THEY ARE COPYRIGHTED PROPERTY OF RUN RUN DESIGN, LLC. THE USE OF THESE DRAWINGS ARE LIMITED TO THIS SPECIFIC PROJECT AND ARE NOT TO BE OTHERWISE REPRODUCED IN ANY WAY OR USED FOR SUPPLEMENTAL LOCATIONS WITHOUT WRITTEN PERMISSION FROM RUN RUN DESIGN, LLC. SHEET NAME: DRAWING REVISIONS: STORE #791 4335 W. 106TH STREET UNIT #1200 CARMEL, IN 48032 12.22.17 STATE COMMENTS 01.11.18 2 3 STATE COMMENTS 02.14.18 17-085 STATE COMMENTS 01.30.18 NOTE: GC MUST REVIEW MECHANICAL AND ELECTRICAL DRAWINGS DURING DEMO PHASE TO VERIFY ALL EXISTING SPECS AND COORDINATE W/ NEW WORK AS DOCUMENTED ON MECH AND ELEC SHEETS. SCALE: NORTH DEMOLITION PLAN 1 1/4" = 1'-0" GENERAL DEMOLITION NOTES A. GENERAL CONTRACTOR SHALL FURNISH ALL LABOR MATERIALS, TOOLS, EQUIPMENT, TRANSPORTATION, INSURANCE, PROTECTION AND OTHER RELATED SERVICE REQUIRED TO COMPLETE ALL DEMOLITION WORK FOR THE TENANT IMPROVEMENTS. B. GENERAL CONTRACTOR TO COORDINATE WITH TENANT, PHASING AND/OR TIMING OF COMMENCEMENT, CONTINUATION AND COMPLETION OF ALL DEMOLITION WORK. C. GENERAL CONTRACTOR SHALL COORDINATE WITH LANDLORD, ANY WORK AFFECTING THE CONTINUITY OF UTILITIES SERVICING OTHER TENANTS ON THE PROPERTY. GENERAL CONTRACTOR SHALL PROTECT ALL UTILITIES SERVING OTHER TENANTS, PEOPLE AND EXISTING AND/OR ADJACENT CONSTRUCTION AND OTHER AREAS FROM DAMAGE INCIDENTAL TO CONSTRUCTION OPERATIONS WITH CONSTRUCTION BARRICADES IN ACCORDANCE WITH CODES AND ORDINANCES OF THE CITY OF WESTMINSTER, CA. D. GENERAL CONTRACTOR SHALL REPAIR OR RESTORE TO EXISTING CONDITION ADJACENT CONSTRUCTION AND PUBLIC OR PRIVATE PROPERTY DAMAGED BY DEMOLITION WORK. E. MATERIAL SHALL NOT BE DROPPED BY GRAVITY OR THROWN OUTSIDE THE CONTRACT AREA DURING DEMOLITION. ANY MATERIAL, WHICH IN ITS REMOVAL WILL CAUSE AN EXCESSIVE AMOUNT OF DUST, SHALL BE WETTED DOWN TO PREVENT THE CREATING OF A NUISANCE. F. ALL PARTS OF THE CONTRACT AREA UNDER DEMOLITION SHALL BE ADEQUATELY LIGHTED WHILE PERSONS ARE ENGAGED AT WORK. G. RUBBISH AND TRASH SHALL BE REMOVED AS OFTEN AS CONDITIONS WARRANT. COMBUSTIBLE RUBBISH, SHALL BE REMOVED DAILY, AND SHALL NOT BE DISPOSED OF BY BURNING ON THE PREMISES. H. GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR HIDDEN CONDITIONS AFFECTING DEMOLITION OF PROPOSED WORK. I. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL SUB-TRADES WITH COMPLETE AND CURRENT DOCUMENTS. J. UPON COMPLETION OF DEMOLITION, THE LEASED PREMISES AND ADJACENT PUBLIC AND PRIVATE PROPERTY SHALL BE LEFT CLEAN AND CLEAR OF DEBRIS. K. VERIFY WITH ARCHITECTURAL DOCUMENTS ALL AREAS TO BE MODIFIED. L. ALL AREAS OF MODIFICATION OR DEMOLITION, WHICH ARE INCORPORATED INTO THE NEW FACILITY, ARE TO BE PATCHED, REPAIRED, OR ADJUSTED TO AN ACCEPTABLE CONDITION. M. CONTRACTOR SHALL PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2A OR 2A10BC WITHIN 75' TRAVEL DISTANCE OF ALL PORTIONS OF THE BUILDING DURING THE DEMOLITION AND CONSTRICTION. N. GENERAL CONTRACTOR SHALL VERIFY ALL ON SITE CONDITIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR OMISSIONS PRIOR TO DEMOLITION AND CONSTRUCTION. O. PATCH ALL CONCRETE SLABS AS REQUIRED DUE TO MODIFICATIONS. P. PROVIDE SECURITY ENCLOSURE AT ALL REMOVED DOORS OR WALLS AS REQUIRED. Q. NOTIFY BUILDING MANAGEMENT AND FIRE ALARM COMPANY OF DEMOLITION OR CONSTRUCTION WORK. FIRE ALARM SYSTEM, (IE: EXITING) IS TO REMAIN ACTIVATED AT ALL TIMES. R. COORDINATE REMOVAL OF ALL FINISHES OF WITH BUILDING OWNER PRIOR TO START OF DEMOLITION. S. EXISTING FIRE SPRINKLER SYSTEM TO REMAIN. T. EXISTING PLUMBING LINES FOR FLOORS ABOVE TO REMAIN. U. EXISTING SPRAY-APPLIED FIRE PROOFING FOUND IN SEVERAL AREAS ON FLOOR DECK ABOVE TO REMAIN KEYNOTES 1. (E) ENTRY DOOR AND STOREFRONT BY LANDLORD TO REMAIN 2. (E) INTERIOR DOOR TO BE REMOVED 3. (E) RESTROOM PLUMBING FIXTURES TO BE REMOVED 4. (E) WALLS TO BE REMOVED PER DASHED LINES 5. LOCATION OF (E) ELECTRICAL PANEL - REFER TO ELECTRICAL SHEETS 6. EXISTING DEMISING WALL TO REMAIN. PREP FOR NEW FINISHES. GC TO VERIFY EXISTING DEMISING WALL IS CONSTRUCTED PER SPECIFICATION ON PLAN. 7. EXISTING REAR DOOR TO REMAIN. 8. REMOVE EXISTING FLOOR FINISHES. SAND SMOOTH IN PREPARATION FOR NEW FINISH. ADD OVERLAY IF REQUIRED. 9. REMOVE EXISTING CEILING GRID & CEILING TILES. 10. REMOVE ALL EXISTING LIGHT FIXTURES 11. EXISTING MECHANICAL GRILLES & DUCTWORK TO BE REMOVED AND RELOCATED AS NECESSARY TO ACCOMMODATE CEILING DESIGN - SEE MECHANICAL SHEETS. XX DEMOLITION PLAN A1.2 03/19/18 Nick Mishler