HomeMy WebLinkAboutA.0005 (Architectural)EXIT X
2'-0"
B
B
B
B
2'-0" 3'-6" 2'-0"
2'-0"
2'-0" 3'-6" 2'-0"
B
B B
B
B
B
B
H
H
H
H
H
H
F F
F
A
A
A
EXIT X
A A A A
A A A A
A A A A
A A
A
A
A A
A A
2'-6"
(TYP)
2'-7" 8'-0"
5'-9"
D
D
E
E
D
D
6'-0" 4'-1"
E
D
D
E
D
D
7'-5" 2'-4" 3'-0" 18'-7"
D
EQ.
E
D
EQ.
10'-1"
D
D
E
D
D
E
D
D
E
D
D
E
D
D
E
8'-0" 9'-2" 9'-1" 6'-5"
E
D
D
E
D
D
E
D
D
2'-6"
(TYP)
5'-0" 5'-0" 5'-9"
EXIT X
Y
Y
A
A
A A
EXIT X
1
C-1 SOFFIT ABOVE
SERVICE COUNTER,
REFER TO DETAIL
7/A6.0. TO REFLECT
SAME FOOTPRINT
OF COUNTER
BELOW.
2
GC TO VERIFY MAX
CEILING HEIGHT IN
FIELD - CONTACT
PROJECT MANAGER
IF LESS THAN 10'-0"
AFF
SOFFIT TO REFLECT
SAME FOOTPRINT
OF COUNTER
BELOW
8'-6"
C-1 (P-2)
8'-6"
C-1 (P-1)
10'-0"
C-3
12'-0"
C-4
10'-0"
C-2
7
A6.0
9
A6.0
12
A6.0
9'-0"
C-3
8'-0"
C-1
9'-0"
C-4
8'-6"
C-1 (P-2)
8'-0"
C-1 (P-1)
C-1: INDICATES AREA OF GYP BD CLG
PAINTED PER PLAN 5/8" TYPE WR GYP BD
ON 20 GA MTL STUDS @ 24" OC AT (SEE
PLAN)
C-2 (2X4) /C-3 (2X2): INDICATES AREA OF
WASHABLE CEILING TILES - SEE PLAN FOR
HEIGHT AFF, REFER TO SPEC ON SHEET
A2.0
C-4: INDICATES AREA OF 2X2 LAY-IN
CEILING TILES - SEE PLAN FOR HEIGHT
AFF, REFER TO SPEC ON SHEET A2.0
NOTES:
1. ALL CEILING DEVICES INCLUDING LIGHTING & HVAC IS
NEW, UNLESS NOTED OTHERWISE.
2. SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
2X4 OR 2X2 SUSPENDED CEILING
A. TABLE BELOW IS BASED ON UNIVERSAL INDUSTRIES, UNIMAST (USG)
CORPORATION'S LIMITING HEIGHT TABLE FOR EMBRACED STUDS SPACED
16" AND 24" O.C. (SYSTEM FOLDER SA-923-1990 EDITION). REQUIREMENT FOR
5 PSF LATERAL PRESSURE AND 1/240 ALLOWABLE DEFLECTION FOR
FLEXIBLE FINISHES, WITH 1 LAYER OF GYP. BD. PER SIDE OF STUD.
B. SCHEDULED HEIGHTS MAY BE INCREASED BY 50% WHERE THE STUDS ARE
DIAGONALLY BRACED AT THE MAXIMUM HEIGHT POINT TO THE STRUCTURE
ABOVE @ 4'-0" O.C.
C. CAUTION! WHEN USING STUDS MANUFACTURED BY A COMPANY OTHER
THEN USG. VERIFY MANUFACTURERS STUD STRENGTH AND LIMITING
HEIGHT. ADJUST GAUGE AND MAXIMUM HEIGHT RECOMMENDED BY
MANUFACTURER'S CURRENT PRINTED SPECIFICATION.
STUD WIDTH STUD TYPE STUD GAUGE STUD SPACING MAX. HEIGHT
158ST25
158ST25
212ST25
212ST25
212ST22
212ST22
212ST20
212ST20
358ST25
358ST25
358ST22
358ST22
358ST20
358ST20
600ST25
600ST25
25
25
25
25
22
22
20
20
25
25
22
22
20
20
25
25
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
9'-6"
7'-3"
12'-6"
10'-9"
13'-0"
11'-6"
14'-0"
12'-3"
16'-0"
13'-6"
17'-3"
15'-0"
18'-3"
16'-0"
20'-0"
15'-0"
1-5/8"
2-1/2"
3-5/8"
6"
SCALE:
NORTH
REFLECTED CEILING PLAN
1 1/4" = 1'-0"
PROJECT NAME AND LOCATION :
no. distribution date
A
project no:
dwg no:
no. revision date
ISSUE DATE 12.21.17
1
B SUBMITTAL DATE
THIS DRAWING AND ITS CONTENTS ARE CONSIDERED INSTRUMENTS OF SERVICE.
AS SUCH THEY ARE COPYRIGHTED PROPERTY OF RUN RUN DES IGN, LLC. THE USE
OF THESE DRAWINGS ARE LIMITED TO THIS SPECIFIC PROJECT AND ARE NOT TO BE
OTHERWISE REPRODUCED IN ANY WAY OR USED FOR SUPPLEMENTAL LOCATIONS
WITHOUT WRITTEN PERMISSION FROM RUN RUN DES IGN, LLC.
SHEET NAME:
DRAWING REVISIONS:
STORE #791
4335 W. 106TH STREET
UNIT #1200
CARMEL, IN 48032
12.22.17
STATE COMMENTS 01.11.18
2
3 STATE COMMENTS 02.14.18
17-085
STATE COMMENTS 01.30.18
REFLECTED CEILING PLAN
A3.0
KEYNOTES
1. NO CEILING ABOVE WALK-IN COOLER/FREEZER
2. EXHAUST PLENUM
XX
CEILING LEGEND
A
SYMBOL FIXTURE
DESCRIPTION: 6" LED RECESSED W/ BLACK RING
LOCATION
DINING AREA
NOTES
WHICH WICH 2017 LIGHTING FIXTURE SCHEDULE
--
B DESCRIPTION: 6" LED RECESSED W/ WHITE RING RESTROOMS /
ABOVE SODA
MACHINE
--
D DESCRIPTION: MINI UNIVERSAL TRACK HEAD -
BLACK
DINING AREA --
E DESCRIPTION: MINI UNIVERSAL TRACK & LIVE
FEED END - BLACK
DINING AREA --
F DESCRIPTION:2X4 RECESSED TROFFER 3-LAMP KITCHEN "EM" EMERGENCY BALLAST
"FIELD INSTALL"
H DESCRIPTION: 2X2 RECESSED TROFFER 2-LAMP SERVICE AREA "EM" EMERGENCY BALLAST
"FIELD INSTALL"
X DESCRIPTION: EXIT SIGN - WHITE BODY W/RED
LETTERS
EXIT(S) --
Y DESCRIPTION: EMERGENCY BUG-EYE - WHITE AS SHOWN ON RCP --
Z DESCRIPTION: EMERGENCY RECESSED - WHITE AS SHOWN ON RCP --
NOTES:
1. LUMINAIRES & LAMPS FURNISHED BY VILLA LIGHTING SUPPLY:
DEREK VICKROY
2929 CHOUTEAU AVENUE
ST. LOUIS, MO 63103
P: 214.633.0654, EMAIL: derek.vickroyf@villalighting.com
2. ALL FIXTURE TYPES MAY NOT BE USED.
3. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS FOR FIXTURE MOUNTING HEIGHTS.
4. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING, STORAGE, INSTALLATION, AND WIRING OF
LIGHT FIXTURES.
5. THE ELECTRICAL CONTRACTOR SHALL REPORT ANY DAMAGED LIGHT FIXTURES OR MISSING PARTS TO VILLA LIGHTING
WITHIN 48 HOURS OF RECEIPT OF LIGHT FIXTURE PACKAGE.
6. LIGHTING TRIM TO MATCH CEILING COLOR. (BLACK CEILING = BLACK TRIM, WHITE CEILING = WHITE TRIM)
H
E
D
A
F
X
Y
B
Z
STUD GAGE SCHEDULE
GENERAL NOTES
A. ALL GRILLES/DIFFUSERS TO MATCH CEILING TILES - SEE
MECHANICAL SHEETS FOR EXACT LOCATION OF DIFFUSERS.
B. SEE ELECTRICAL SHEETS FOR LIGHTING SPECIFICATIONS AND
EMERGENCY PACK LOCATIONS.
C. EXTERIOR SIGN UNDER SEPARATE PERMIT - PROVIDED BY SIGN
COMPANY AND INSTALLED BY SIGN COMPANY.
D. ALL LIGHTS IN THE PREPARATION AREA, STORAGE AREA,
DISHWASH AREA, WALK-IN REFRIGERATOR, AND FREEZER MUST
HAVE SHATTERPROOF COVERS.
E. SIGN MANUFACTURER TO SUBMIT TO LANDLORD, AS REQUIRED,
DETAILED CUT SHEETS FOR MAIN STOREFRONT SIGN. LANDLORD
MUST APPROVE ALL SIGNS IN WRITING PRIOR TO FABRICATION, AS
REQUIRED.
F. REFER TO SHEET A5.0 FOR SIGNAGE [INTERIOR (G-1 THROUGH
G-6)] AND INTERIOR DECOR (ID1-ID5) SPECIFICATIONS.
03/19/18
Nick Mishler