Loading...
HomeMy WebLinkAboutA.0005 (Architectural)EXIT X 2'-0" B B B B 2'-0" 3'-6" 2'-0" 2'-0" 2'-0" 3'-6" 2'-0" B B B B B B B H H H H H H F F F A A A EXIT X A A A A A A A A A A A A A A A A A A A A 2'-6" (TYP) 2'-7" 8'-0" 5'-9" D D E E D D 6'-0" 4'-1" E D D E D D 7'-5" 2'-4" 3'-0" 18'-7" D EQ. E D EQ. 10'-1" D D E D D E D D E D D E D D E 8'-0" 9'-2" 9'-1" 6'-5" E D D E D D E D D 2'-6" (TYP) 5'-0" 5'-0" 5'-9" EXIT X Y Y A A A A EXIT X 1 C-1 SOFFIT ABOVE SERVICE COUNTER, REFER TO DETAIL 7/A6.0. TO REFLECT SAME FOOTPRINT OF COUNTER BELOW. 2 GC TO VERIFY MAX CEILING HEIGHT IN FIELD - CONTACT PROJECT MANAGER IF LESS THAN 10'-0" AFF SOFFIT TO REFLECT SAME FOOTPRINT OF COUNTER BELOW 8'-6" C-1 (P-2) 8'-6" C-1 (P-1) 10'-0" C-3 12'-0" C-4 10'-0" C-2 7 A6.0 9 A6.0 12 A6.0 9'-0" C-3 8'-0" C-1 9'-0" C-4 8'-6" C-1 (P-2) 8'-0" C-1 (P-1) C-1: INDICATES AREA OF GYP BD CLG PAINTED PER PLAN 5/8" TYPE WR GYP BD ON 20 GA MTL STUDS @ 24" OC AT (SEE PLAN) C-2 (2X4) /C-3 (2X2): INDICATES AREA OF WASHABLE CEILING TILES - SEE PLAN FOR HEIGHT AFF, REFER TO SPEC ON SHEET A2.0 C-4: INDICATES AREA OF 2X2 LAY-IN CEILING TILES - SEE PLAN FOR HEIGHT AFF, REFER TO SPEC ON SHEET A2.0 NOTES: 1. ALL CEILING DEVICES INCLUDING LIGHTING & HVAC IS NEW, UNLESS NOTED OTHERWISE. 2. SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. 2X4 OR 2X2 SUSPENDED CEILING A. TABLE BELOW IS BASED ON UNIVERSAL INDUSTRIES, UNIMAST (USG) CORPORATION'S LIMITING HEIGHT TABLE FOR EMBRACED STUDS SPACED 16" AND 24" O.C. (SYSTEM FOLDER SA-923-1990 EDITION). REQUIREMENT FOR 5 PSF LATERAL PRESSURE AND 1/240 ALLOWABLE DEFLECTION FOR FLEXIBLE FINISHES, WITH 1 LAYER OF GYP. BD. PER SIDE OF STUD. B. SCHEDULED HEIGHTS MAY BE INCREASED BY 50% WHERE THE STUDS ARE DIAGONALLY BRACED AT THE MAXIMUM HEIGHT POINT TO THE STRUCTURE ABOVE @ 4'-0" O.C. C. CAUTION! WHEN USING STUDS MANUFACTURED BY A COMPANY OTHER THEN USG. VERIFY MANUFACTURERS STUD STRENGTH AND LIMITING HEIGHT. ADJUST GAUGE AND MAXIMUM HEIGHT RECOMMENDED BY MANUFACTURER'S CURRENT PRINTED SPECIFICATION. STUD WIDTH STUD TYPE STUD GAUGE STUD SPACING MAX. HEIGHT 158ST25 158ST25 212ST25 212ST25 212ST22 212ST22 212ST20 212ST20 358ST25 358ST25 358ST22 358ST22 358ST20 358ST20 600ST25 600ST25 25 25 25 25 22 22 20 20 25 25 22 22 20 20 25 25 16" 24" 16" 24" 16" 24" 16" 24" 16" 24" 16" 24" 16" 24" 16" 24" 9'-6" 7'-3" 12'-6" 10'-9" 13'-0" 11'-6" 14'-0" 12'-3" 16'-0" 13'-6" 17'-3" 15'-0" 18'-3" 16'-0" 20'-0" 15'-0" 1-5/8" 2-1/2" 3-5/8" 6" SCALE: NORTH REFLECTED CEILING PLAN 1 1/4" = 1'-0" PROJECT NAME AND LOCATION : no. distribution date A project no: dwg no: no. revision date ISSUE DATE 12.21.17 1 B SUBMITTAL DATE THIS DRAWING AND ITS CONTENTS ARE CONSIDERED INSTRUMENTS OF SERVICE. AS SUCH THEY ARE COPYRIGHTED PROPERTY OF RUN RUN DES IGN, LLC. THE USE OF THESE DRAWINGS ARE LIMITED TO THIS SPECIFIC PROJECT AND ARE NOT TO BE OTHERWISE REPRODUCED IN ANY WAY OR USED FOR SUPPLEMENTAL LOCATIONS WITHOUT WRITTEN PERMISSION FROM RUN RUN DES IGN, LLC. SHEET NAME: DRAWING REVISIONS: STORE #791 4335 W. 106TH STREET UNIT #1200 CARMEL, IN 48032 12.22.17 STATE COMMENTS 01.11.18 2 3 STATE COMMENTS 02.14.18 17-085 STATE COMMENTS 01.30.18 REFLECTED CEILING PLAN A3.0 KEYNOTES 1. NO CEILING ABOVE WALK-IN COOLER/FREEZER 2. EXHAUST PLENUM XX CEILING LEGEND A SYMBOL FIXTURE DESCRIPTION: 6" LED RECESSED W/ BLACK RING LOCATION DINING AREA NOTES WHICH WICH 2017 LIGHTING FIXTURE SCHEDULE -- B DESCRIPTION: 6" LED RECESSED W/ WHITE RING RESTROOMS / ABOVE SODA MACHINE -- D DESCRIPTION: MINI UNIVERSAL TRACK HEAD - BLACK DINING AREA -- E DESCRIPTION: MINI UNIVERSAL TRACK & LIVE FEED END - BLACK DINING AREA -- F DESCRIPTION:2X4 RECESSED TROFFER 3-LAMP KITCHEN "EM" EMERGENCY BALLAST "FIELD INSTALL" H DESCRIPTION: 2X2 RECESSED TROFFER 2-LAMP SERVICE AREA "EM" EMERGENCY BALLAST "FIELD INSTALL" X DESCRIPTION: EXIT SIGN - WHITE BODY W/RED LETTERS EXIT(S) -- Y DESCRIPTION: EMERGENCY BUG-EYE - WHITE AS SHOWN ON RCP -- Z DESCRIPTION: EMERGENCY RECESSED - WHITE AS SHOWN ON RCP -- NOTES: 1. LUMINAIRES & LAMPS FURNISHED BY VILLA LIGHTING SUPPLY: DEREK VICKROY 2929 CHOUTEAU AVENUE ST. LOUIS, MO 63103 P: 214.633.0654, EMAIL: derek.vickroyf@villalighting.com 2. ALL FIXTURE TYPES MAY NOT BE USED. 3. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS FOR FIXTURE MOUNTING HEIGHTS. 4. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING, STORAGE, INSTALLATION, AND WIRING OF LIGHT FIXTURES. 5. THE ELECTRICAL CONTRACTOR SHALL REPORT ANY DAMAGED LIGHT FIXTURES OR MISSING PARTS TO VILLA LIGHTING WITHIN 48 HOURS OF RECEIPT OF LIGHT FIXTURE PACKAGE. 6. LIGHTING TRIM TO MATCH CEILING COLOR. (BLACK CEILING = BLACK TRIM, WHITE CEILING = WHITE TRIM) H E D A F X Y B Z STUD GAGE SCHEDULE GENERAL NOTES A. ALL GRILLES/DIFFUSERS TO MATCH CEILING TILES - SEE MECHANICAL SHEETS FOR EXACT LOCATION OF DIFFUSERS. B. SEE ELECTRICAL SHEETS FOR LIGHTING SPECIFICATIONS AND EMERGENCY PACK LOCATIONS. C. EXTERIOR SIGN UNDER SEPARATE PERMIT - PROVIDED BY SIGN COMPANY AND INSTALLED BY SIGN COMPANY. D. ALL LIGHTS IN THE PREPARATION AREA, STORAGE AREA, DISHWASH AREA, WALK-IN REFRIGERATOR, AND FREEZER MUST HAVE SHATTERPROOF COVERS. E. SIGN MANUFACTURER TO SUBMIT TO LANDLORD, AS REQUIRED, DETAILED CUT SHEETS FOR MAIN STOREFRONT SIGN. LANDLORD MUST APPROVE ALL SIGNS IN WRITING PRIOR TO FABRICATION, AS REQUIRED. F. REFER TO SHEET A5.0 FOR SIGNAGE [INTERIOR (G-1 THROUGH G-6)] AND INTERIOR DECOR (ID1-ID5) SPECIFICATIONS. 03/19/18 Nick Mishler