HomeMy WebLinkAboutA000.0 2ENTRY 201 OPEN OFFICE 214 OFFICE 204 OFFICE 205 OFFICE 206 CONFERENCE 207 HUDDLE 211 CONFERENCE 203 CLOSET 202 COPY 215 COPY 212 MAILROOM 210 LAN 209 STORAGE 208 REFRIG BY TENANT . C . U G I R F E R REFRIG BY TENANT MICRO BREAK 213 1'-10" 21'-4" 2'-8" 14'-1 1 4 9'-2 " 3 4 " 2'-8 1 2 " 5'-0" 7'-3 1 4 8'-8 " 1 2 " 24'-2 3 4 " 15'-4" 12'-6 3 4 " 2'-6 3 4 " 12'-6 1 4 " 8'-10" 1' - 6" 2'-6" 19'-4 3 4 " 112° 6'-11 1 4 " 4'-1 1 2 " 113° 6' - 7" FE FE 6'-8" 10'-2 1 4 " 9'-8 1 4 " 30'-4" EQ. EQ. 5'-0" 3'-11 1 2 " 23'-8 3 4 " 15'-4 1 4 " 2'-7 1 2 " 90° ARCHITECTURAL FLOOR PLAN A111 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x 3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW OR SALVAGED SEMI-RECESSED FIRE EXTINGUISHER CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE COAT ROD AND SHELF AT THIS LOCATION; SEE DETAIL 2/A211 FOR MORE DETAILS. PROVIDE (9) BRUSHED CHROME DOUBLE COAT HOOKS AT MAXIMUM 48" A.F.F. FOR ADA COMPLIANCE AT THIS LOCATION. NOT USED. PLAN NOTES AREA NOT IN CONTRACT ARCHITECTURAL PLAN AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL STANDARD WALL 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING DEMISING WALL TO DECK WITH INSULATION 35 8" METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL W1 W2 WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W3 W4 PARTIAL HEIGHT WALL 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 3'-4 1 2"; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; REFER TO ELEVATION 7 ON SHEET A211 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DATE DESCRIPTION ISSUE 02.16.18 REVIEW SET 02.20.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY AMERISURE 900 E. 96TH ST. - SUITE 275 INDIANAPOLIS, IN 46240 SDH KV 2017.362 2ND FLOOR N 0 2' 4' 8' 16' 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. GENERAL NOTES A211 3 A211 4 A211 5 A211 6 A211 7 W2 W2 W2 W2 W2 W2 W2 W2 W2 W2 A211 8 W4 PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. CASEWORK CONTRACTOR TO INSTALL RAKKS EH-1818-FM BRACKET AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. IF COLUMN SIZE CAN BE REDUCED, WRAP COLUMN AS TIGHT AS POSSIBLE WITH GYPSUM BOARD. CONFIRM THAT WALL MATCHES WALL TYPE "W3" IN THIS LOCATION. IF NOT, PROVIDE ALTERNATE PRICE TO ALTER EXISTING WALL TO MATCH WALL TYPER "W3" IN THIS LOCATION. HOLD DRYWALL AS TIGHT TO COLUMN AS POSSIBLE IN THIS LOCATION. DESIGN INTENT IS TO LEAVE AS MUCH FLOOR SPACE OPEN IN THE MAILROOM AS POSSIBLE. FURR OUT EXISTING WALL AS REQUIRED FOR NEW PLUMBING AND ELECTRICAL. DESIGN INTENT IS FOR NEW DRYWALL TO BE HELD AS TIGHT AS POSSIBLE TO EXISTING WALL. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PROVIDE WATER LINE FOR ICE/H20 UNIT AND TENANT PROVIDED COFFEE MAKER. CONFIRM LOCATION WITH TENANT. CONFIRM IF ICE MAKER REQUIRES DRAIN. W3 W3 W3 W3 W3 04/05/18 Nick Mishler