HomeMy WebLinkAboutA000.0 3S N S N S N S N S N3 S N3 S N ELN ELN ELN ELN ELN S NG ELN S N S N S N S ND S N REFLECTED CEILING PLAN A121 CONTROL OPEN OFFICE, BREAK, AND MAILROOM LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. PROVIDE SEPARATE AC MINI SPLIT SYSTEM IN THIS LOCATION. COORDINATE EXACT SPECIFICATIONS WITH TENANT. WHERE NEW COMMON CORRIDOR IS CREATED, REWORK LIGHTING PER NEW WALL LAYOUT AS REQUIRED AND TIE INTO BUILDING SYSTEM. NOTE THAT DOWNLIGHT IS NOT NECESSARIILY CENTERED IN TILE. DOWNLIGHTS TO BE CENTERED AND EQUALLY SPACE IN CLOSET. 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2'x2' AT 9'-0" A.F.F. TILES ARE 2'x2' ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS "NEW OR RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATION AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENT IS LESS THAN 50% OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 5. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE. 6. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. GENERAL NOTES PLAN NOTES SWITCH, PROJECTOR SCREEN LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH NP ND N N3 P D 3 EXIT LIGHT FIXTURE LIGHT FIXTURE, PENDANT RECESSED LIGHT FIXTURE LIGHT FIXTURE, 2'x2', FLUORESCENT. PARABOLIC LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC PROVIDE ALTERNATE PRICE FOR 2'X4' LSI LED LOW PROFILE RECESSED TROFFER RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 1'x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' CEILING GRID, SUSPENDED, 2'x4' NIGHT LIGHT NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 1'x4', FLUORESCENT, PARABOLIC LIGHT FIXTURE, 1'x4', FLUORESCENT, INDIRECT LIGHT FIXTURE, TRACK WALL SCONCE LIGHT FIXTURE LIGHT FIXTURE, PENDANT LIGHT FIXTURE, 1'x4', FLUORESCENT, INDIRECT LIGHT FIXTURE, TRACK EXIT LIGHT FIXTURE SWITCH, PROJECTOR SCREEN LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' CEILING GRID, SUSPENDED, 2'x4' EXISTING DIFFUSER, LAY-IN, 4"x4' EXISTING DIFFUSER, LAY-IN, 1'x4' EXISTING DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 4'x4' TEES TO COMPLETE GRID CEILING GRID, SUSPENDED, 4'x4' GYPSUM BOARD CEILING LIGHT FIXTURE, 2'x2', FLUORESCENT. PARABOLIC LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC LIGHT FIXTURE, 1'x4', FLUORESCENT, PARABOLIC LEGEND AREA NOT IN CONTRACT REFLECTED CEILING PLAN AREA OF WORK RECESSED LIGHT FIXTURE WALL SCONCE LIGHT FIXTURE DATE DESCRIPTION ISSUE 02.16.18 REVIEW SET 02.20.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY AMERISURE 900 E. 96TH ST. - SUITE 275 INDIANAPOLIS, IN 46240 SDH KV 2017.362 2ND FLOOR N 0 2' 4' 8' 16' EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES A121 1 MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP EXHAUST FAN, 2'x2' EXISTING EXHAUST FAN, 2'x2' GYPSUM BOARD CEILING SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) NG G SWITCH, GARBAGE DISPOSAL EXPOSED TO DECK 04/05/18 Nick Mishler