Loading...
HomeMy WebLinkAboutA000.0 5NOTE: WHERE SPAN EXCEEDS 4'-0", PROVIDE A CENTER SUPPORT BRACKET. NOTE: PROVIDE (9) BRUSHED CHROME DOUBLE COAT HOOKS AT MAXIMUM 48" A.F.F. FOR ADA COMPLIANCE. BLACK MELAMINE SHELF SUPPORTS (TYP. EACH END) 11 4" DIA. ROD BASE CABINETS (SEE CASEWORK NOTE 1) FALSE PANEL FALSE PANEL 2'-10" 24" DEEP PLASTIC LAMINATE (PL2) COUNTERTOP WITH 4" HIGH BACK SPLASH *SEE PLAN NOTE (F04) FOR ALTERNATE PRICE OPTION 1'-5" 3'-10" 1'-8" 2'-101 2" 2'-10 1 2" 2'-10 1 2" 45 DEGREE MITRED BACKSPLASH EXIST 4"V. EXIST 4"W. 2"W. F.F. 2"W. 2"W. SINK TO BUILDING DRAIN F.F. 11 2"V. CLG. 11 2"V. CLG. TO EXISTING STACK 3'-7" 8" 7" 8'-0" 3'-0" D5 8" 1 4" TEMPERED GLASS, WOOD FLUSH BEAD STAINED TO MATCH DOOR 8'-0" 3'-0" EQ. EQ. 4" STAINLESS STEEL TOP RAIL 1/2" TEMPERED GLASS PROVIDE ONE PULL ON EACH SIDE OF DOOR (TOTAL COUNT 2), AS NOTED IN REMARKS 4" STAINLESS STEEL TOP RAIL D4 USE SINGLE GLASS IF FULL WIDTH IS LESS THAN 4'-6" FILM PATTERN TBD IF ALTERNATE PRICE IS ACCEPTED 8'-0" EQ. EQ. 3'-0" 4" STAINLESS STEEL TOP RAIL 1/2" TEMPERED GLASS 4" STAINLESS STEEL TOP RAIL USE SINGLE GLASS IF FULL WIDTH IS LESS THAN 4'-6" PROVIDE ONE LOCKING LADDER PULL ON EACH SIDE OF DOOR (TOTAL COUNT (4, AS NOTED IN REMARKS D6 F2 6'-4" 2" 8'-2" 8'-0" 2" F1 8'-2" 3'-0" 3'-4" 2" 2" 8'-0" 2" 2" F3 6'-6" 2" 3'-0" 8'-2" 8'-0" 2" 2" 3'-0" 2" 1 4" TEMPERED GLASS SINGLE BOWL SINK: 18 GAUGE STAINLESS STEEL, 25"x21 1 4" WITH KOHLER SIMPLICE FAUCET #K-597 (OR EQUAL) *NOTE-IF ALTERNATE PRICE COUNTERTOP FOR (SS1) IS ACCEPTED, THEN USE THIS SINK AND FACUET SPECIFICATIONS: SINGLE BOWL UNDER-MOUNT SINK: 18 GAUGE STAINLESS STEEL ELKAY 231 2"x18 1 4"x5 3 8" #ELUHAD211555 (OR EQUAL) WITH KOHLER SIMPLICE FAUCET #K-597 (OR EQUAL) 3'-0" ADA (32 1 4" H) UC REFRIG BY CONTRACTOR 2'-8" 2'-0" 2'-8" 24" DEEP PLASTIC LAMINATE (PL2) COUNTERTOP WITH 4" HIGH BACK SPLASH *SEE PLAN NOTE (F04) FOR (SS1) ALTERNATE PRICE OPTION BASE CABINETS (SEE CASEWORK NOTE 1) 2'-10" 4'-0" (CLEAR) 3'-5" 3'-0" 25" DEEP PLASTIC LAMINATE (PL2) COUNTERTOP WITH 4" HIGH BACK SPLASH PLASTIC LAMINATE BASE CABINETS (SEE CASEWORK NOTE 1) 3'-5" 3'-5" 3'-5" 3'-5" 3'-5" WALL CABINETS (SEE CASEWORK NOTE 1) REFRIG. BY TENANT 8'-7 1 4" (CLEAR) REFRIG. BY TENANT 2'-3" 3'-0" 2'-9" 2'-10" 1'-9" 2'-6" WALL CABINETS (SEE CASEWORK NOTE 1) SINGLE BOWL SINK: 18 GAUGE STAINLESS STEEL, 25"x21 1 4" WITH KOHLER SIMPLICE FAUCET #K-597 (OR EQUAL), AND GARBAGE DISPOSAL *NOTE-IF ALTERNATE PRICE COUNTERTOP FOR (SS1) IS ACCEPTED, THEN USE THIS SINK AND FACUET SPECIFICATIONS: SINGLE BOWL UNDER-MOUNT SINK: 18 GAUGE STAINLESS STEEL ELKAY 231 2"x18 1 4"x5 3 8" #ELUHAD211555 (OR EQUAL) WITH KOHLER SIMPLICE FAUCET #K-597 (OR EQUAL) 24" DEEP PLASTIC LAMINATE (PL2) COUNTERTOP WITH 4" HIGH BACK SPLASH. *SEE PLAN NOTE (F04) FOR ALTERNATE PRICE OPTION BASE CABINETS (SEE CASEWORK NOTE 1) 1'-3 1 2" 1'-5" MICRO BOX 18"D SHELF 2'-0" 1'-6" 1'-3" 2'-0" PULL OUT TRASH 2'-9" 2'-9" 2'-11" 2'-7" 2'-7" 2'-7" 2'-11" ADJUST MICRO BOX TO FIT TENANT PROVIDED MICROWAVE. MICRO 21 1 2"W X 12"H. CONFIRM DIMENSIONS WITH TENANT. PAINTED DRYWALL 3'-6" 10'-0" SUPPORT TOP AS NEEDED WITH RAKKS EH-1818-FM ATTACHED TO METAL STUDS WITH WOOD BLOCKING AS NEEDED. DRYWALL TO BE INSTALLED OVER VERTICAL SUPPORT. 48" DEEP PLASTIC LAMINATE (PL2) COUNTERTOP CENTERED ON WALL WITH MITRED WATERFALL EDGE TO FLOOR ON BOTH ENDS. *SEE PLAN NOTE (F04) FOR ALTERNATE PRICE OPTION VINYL BASE NO VINYL BASE AT WATERFALL EDGE PROVIDE (2) POWER GROMMETS IN COUNTERTOP. REFER TO NOTE (E13) ON E111 SHEET FURTHER DETAILS. SUPPORT TOP AS NEEDED WITH RAKKS EH-1818-FM ATTACHED TO METAL STUDS WITH WOOD BLOCKING AS NEEDED. DRYWALL TO BE INSTALLED OVER VERTICAL SUPPORT. 24" DEEP PLASTIC LAMINATE (PL2) COUNTERTOP. SEAM SEAL COUNTERTOP TO WALL AS TIGHTLY AS POSSIBLE. DESIGN INTENT IS FOR NO GAPS TO BE PRESENT BETWEEN COUNTERTOP AND WALL. *SEE PLAN NOTE (F04) FOR ALTERNATE PRICE OPTION 3'-6" 21'-01 4 " VINYL BASE 8'-0" D1 3'-0" 1'-0" 8" 7" 7" 8'-0" 3'-0" D2 1 4" TEMPERED GLASS, WOOD FLUSH BEAD STAINED TO MATCH DOOR 8'-0" D3 3'-0" BI-FOLD DOOR DOOR SCHEDULE # DIMENSIONS DOOR FRAME HARDWARE REM. 01A R3 01B R1 02 03 PP R1 04 05 06 07 PP R1 08 09 10 15 R2 DOOR SCHEDULE INTERIOR DETAILS A211 TYPICAL ALL SINGLE LOCATIONS, GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF BASE CABINET PRIOR TO ORDERING. 1. PROVIDE A.W.I. CUSTOM GRADE, FLUSH-OVERLAY CABINETS. FABRICATE WITH PLASTIC LAMINATE (PL1) COVERED M.D.O. BOARD WITH 4" WIRE PULLS. COORDINATE WITH ELEVATIONS FOR QUANTITIES. - AT BREAK ROOM & CONFERENCE PROVIDE: 24" DEEP COUNTERTOPS 23" DEEP BASE CABINETS 11 1 2" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS - AT MAIL ROOM PROVIDE: 25" DEEP COUNTERTOPS 24" DEEP BASE CABINETS 11 1 2" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS - 4" BASE AT CABINETS TO BE VINYL BASE AS SPECIFIED, UNLESS NOTED OTHERWISE. CASEWORK NOTES CL CLOSER CH COAT HOOK CR CARD READER BY TENANT (N.I.C.) DB DEADBOLT DL DUMMY LEVER EL ELECTROMAGNETIC LOCK (PER IBC 2012) ES ELECTRIC STRIKE BY TENANT (N.I.C.) H HOLD OPEN KP KICK PLATE KS KICK STOP OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL- SEE REMARKS FOR SPEC. PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES HARDWARE LEGEND NOTE: REFER TO FLOORPLAN AND CASEWORK ELEVATIONS FOR SINK LOCATIONS. DATE DESCRIPTION ISSUE 02.16.18 REVIEW SET 02.20.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY AMERISURE 900 E. 96TH ST. - SUITE 275 INDIANAPOLIS, IN 46240 SDH KV 2017.362 2ND FLOOR DOOR/FRAME TYPES 0 1' 2' 4' ELEVATION - CONFERENCE 203 A211 3 0 3" 6" 1' 2' COAT/ROD DETAIL A211 2 NOT TO SCALE RISER DIAGRAM A211 1 D5 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING CR,ES,PP,CL R1. PROVIDE ROCKWOOD POST MOUNT PULLS; ONE OF EACH SIDE OF DOOR (QTY=2 PER DOOR) R2. FINISH TENANT SIDE OF DOOR AND FRAME TO MATCH SUITE STANDARD STAIN COLOR. FINISH CORRIDOR SIDE OF DOOR AND FRAME TO MATCH BUILDING STANDARD STAIN COLOR IN PUBLIC CORRIDORS. R3. LONG LOCKING LADDER PULL (MATCH VACANCY DOWN THE HALL). D4 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING CR,ES,PP,CL 3'-0"x8'-0"x1 3 4" (PAIR) D3 RL, DL REMARKS DOOR/FRAME NOTES 1. REUSE DOORS FROM DEMOLITION WHERE POSSIBLE; TOUCH UP EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO MATCH EXISTING. PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED. 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: · 7'-0" HT. TO HAVE 3 HINGES · GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES · FINISH TO MATCH HARDWARE SET 8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. TYPE MATERIAL FINISH TYPE MATERIAL FINISH 0 1' 2' 4' ELEVATION - CONFERENCE 203 A211 4 D4 HERCULITE GLASS SYSTEM -- DRYWALL WRAPPED OPENING D2 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F3 TIMELY MATCH EXIST. OL D2 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F3 TIMELY MATCH EXIST. OL D2 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F3 TIMELY MATCH EXIST. OL D4 HERCULITE GLASS SYSTEM -- DRYWALL WRAPPED OPENING D1 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F1 TIMELY MATCH EXIST. CR, ES, SL, CL D1 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F1 TIMELY MATCH EXIST. CR, ES, SL, CL D1 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F1 TIMELY MATCH EXIST. PS D6 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F1 TIMELY MATCH EXIST. CR, ES, SL, CL 3'-0"x8'-0"x1 3 4" 3'-0"x8'-0"x1 3 4" 3'-0"x8'-0"x1 3 4" 3'-0"x8'-0"x1 3 4" 3'-0"x8'-0"x1 3 4" 3'-0"x8'-0"x1 3 4" 3'-0"x8'-0"x1 3 4" 3'-0"x8'-0"x1 3 4" 3'-0"x8'-0"x1 3 4" 3'-0"xFULL HEIGHT 3'-0"xFULL HEIGHT SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F2 TIMELY MATCH EXIST. 0 1' 2' 4' ELEVATION - MAILROOM 210 A211 5 0 1' 2' 4' ELEVATION -BREAK 213 A211 6 0 1' 2' 4' ELEVATION -BREAK 213 A211 7 0 1' 2' 4' ELEVATION -BREAK 213 A211 8 NOTE: AT DOOR (O1B), PORTION OF WALL IS ON ANGLE. 04/05/18 Nick Mishler