HomeMy WebLinkAboutA000.0 5NOTE: WHERE SPAN
EXCEEDS 4'-0", PROVIDE A
CENTER SUPPORT BRACKET.
NOTE: PROVIDE (9)
BRUSHED CHROME DOUBLE
COAT HOOKS AT MAXIMUM
48" A.F.F. FOR ADA
COMPLIANCE.
BLACK MELAMINE SHELF
SUPPORTS (TYP. EACH
END)
11
4" DIA. ROD
BASE CABINETS
(SEE CASEWORK NOTE 1)
FALSE
PANEL
FALSE
PANEL
2'-10"
24" DEEP PLASTIC LAMINATE
(PL2) COUNTERTOP WITH 4"
HIGH BACK SPLASH
*SEE PLAN NOTE (F04) FOR
ALTERNATE PRICE OPTION
1'-5" 3'-10" 1'-8"
2'-101
2" 2'-10
1
2" 2'-10
1
2"
45 DEGREE MITRED
BACKSPLASH
EXIST
4"V.
EXIST
4"W.
2"W.
F.F.
2"W.
2"W.
SINK
TO
BUILDING
DRAIN
F.F.
11
2"V.
CLG.
11
2"V.
CLG.
TO EXISTING
STACK
3'-7" 8"
7"
8'-0"
3'-0"
D5
8"
1
4" TEMPERED
GLASS,
WOOD FLUSH
BEAD STAINED
TO MATCH
DOOR
8'-0"
3'-0" EQ. EQ.
4" STAINLESS STEEL
TOP RAIL
1/2" TEMPERED GLASS
PROVIDE ONE PULL ON
EACH SIDE OF DOOR
(TOTAL COUNT 2), AS
NOTED IN REMARKS
4" STAINLESS STEEL TOP
RAIL
D4
USE SINGLE GLASS IF FULL
WIDTH IS LESS THAN 4'-6"
FILM PATTERN TBD IF
ALTERNATE PRICE IS
ACCEPTED
8'-0"
EQ. EQ. 3'-0"
4" STAINLESS STEEL
TOP RAIL
1/2" TEMPERED GLASS
4" STAINLESS STEEL TOP
RAIL
USE SINGLE GLASS IF FULL
WIDTH IS LESS THAN 4'-6"
PROVIDE ONE
LOCKING LADDER PULL
ON EACH SIDE OF
DOOR (TOTAL COUNT
(4, AS NOTED IN
REMARKS
D6
F2
6'-4"
2"
8'-2"
8'-0" 2"
F1
8'-2"
3'-0"
3'-4"
2" 2"
8'-0" 2"
2"
F3
6'-6"
2" 3'-0"
8'-2"
8'-0" 2"
2" 3'-0" 2"
1
4" TEMPERED
GLASS
SINGLE BOWL SINK: 18 GAUGE
STAINLESS STEEL, 25"x21
1
4" WITH
KOHLER SIMPLICE FAUCET #K-597
(OR EQUAL)
*NOTE-IF ALTERNATE PRICE
COUNTERTOP FOR (SS1) IS
ACCEPTED, THEN USE THIS SINK
AND FACUET SPECIFICATIONS:
SINGLE BOWL UNDER-MOUNT SINK:
18 GAUGE STAINLESS STEEL ELKAY
231
2"x18
1
4"x5
3
8" #ELUHAD211555
(OR EQUAL) WITH KOHLER
SIMPLICE FAUCET #K-597 (OR
EQUAL)
3'-0"
ADA
(32
1
4" H)
UC REFRIG
BY
CONTRACTOR
2'-8" 2'-0" 2'-8"
24" DEEP PLASTIC LAMINATE
(PL2) COUNTERTOP WITH 4"
HIGH BACK SPLASH
*SEE PLAN NOTE (F04) FOR
(SS1) ALTERNATE PRICE
OPTION
BASE CABINETS
(SEE CASEWORK NOTE 1)
2'-10"
4'-0"
(CLEAR)
3'-5"
3'-0"
25" DEEP PLASTIC LAMINATE
(PL2) COUNTERTOP WITH 4"
HIGH BACK SPLASH
PLASTIC LAMINATE BASE
CABINETS (SEE
CASEWORK NOTE 1)
3'-5" 3'-5"
3'-5" 3'-5" 3'-5"
WALL CABINETS
(SEE CASEWORK NOTE 1)
REFRIG. BY
TENANT
8'-7
1
4"
(CLEAR)
REFRIG. BY
TENANT
2'-3" 3'-0" 2'-9"
2'-10" 1'-9" 2'-6"
WALL CABINETS
(SEE CASEWORK NOTE 1)
SINGLE BOWL SINK: 18 GAUGE
STAINLESS STEEL, 25"x21
1
4" WITH
KOHLER SIMPLICE FAUCET #K-597
(OR EQUAL), AND GARBAGE
DISPOSAL
*NOTE-IF ALTERNATE PRICE
COUNTERTOP FOR (SS1) IS
ACCEPTED, THEN USE THIS SINK
AND FACUET SPECIFICATIONS:
SINGLE BOWL UNDER-MOUNT SINK:
18 GAUGE STAINLESS STEEL ELKAY
231
2"x18
1
4"x5
3
8" #ELUHAD211555
(OR EQUAL) WITH KOHLER
SIMPLICE FAUCET #K-597 (OR
EQUAL)
24" DEEP PLASTIC LAMINATE
(PL2) COUNTERTOP WITH 4"
HIGH BACK SPLASH. *SEE PLAN
NOTE (F04) FOR ALTERNATE
PRICE OPTION
BASE CABINETS
(SEE CASEWORK NOTE 1)
1'-3
1
2"
1'-5"
MICRO BOX
18"D SHELF
2'-0"
1'-6" 1'-3"
2'-0"
PULL OUT TRASH
2'-9" 2'-9"
2'-11" 2'-7" 2'-7" 2'-7" 2'-11"
ADJUST MICRO BOX TO FIT
TENANT PROVIDED
MICROWAVE. MICRO 21
1
2"W X
12"H. CONFIRM DIMENSIONS
WITH TENANT.
PAINTED DRYWALL
3'-6"
10'-0"
SUPPORT TOP AS NEEDED
WITH RAKKS EH-1818-FM
ATTACHED TO METAL STUDS
WITH WOOD BLOCKING AS
NEEDED. DRYWALL TO BE
INSTALLED OVER VERTICAL
SUPPORT.
48" DEEP PLASTIC LAMINATE (PL2)
COUNTERTOP CENTERED ON WALL
WITH MITRED WATERFALL EDGE TO
FLOOR ON BOTH ENDS. *SEE PLAN
NOTE (F04) FOR ALTERNATE PRICE
OPTION
VINYL BASE
NO VINYL BASE AT
WATERFALL EDGE
PROVIDE (2) POWER GROMMETS IN
COUNTERTOP. REFER TO NOTE (E13)
ON E111 SHEET FURTHER DETAILS.
SUPPORT TOP AS
NEEDED WITH RAKKS
EH-1818-FM ATTACHED
TO METAL STUDS WITH
WOOD BLOCKING AS
NEEDED. DRYWALL TO
BE INSTALLED OVER
VERTICAL SUPPORT.
24" DEEP PLASTIC
LAMINATE (PL2)
COUNTERTOP. SEAM
SEAL COUNTERTOP TO
WALL AS TIGHTLY
AS POSSIBLE. DESIGN
INTENT IS FOR NO GAPS
TO BE PRESENT BETWEEN
COUNTERTOP AND WALL.
*SEE PLAN NOTE (F04) FOR
ALTERNATE PRICE OPTION
3'-6"
21'-01
4
"
VINYL BASE
8'-0"
D1
3'-0"
1'-0" 8"
7" 7"
8'-0"
3'-0"
D2
1
4" TEMPERED
GLASS,
WOOD
FLUSH
BEAD
STAINED
TO MATCH
DOOR
8'-0"
D3
3'-0"
BI-FOLD
DOOR
DOOR SCHEDULE
# DIMENSIONS DOOR FRAME HARDWARE REM.
01A R3
01B R1
02
03 PP R1
04
05
06
07 PP R1
08
09
10
15 R2
DOOR SCHEDULE
INTERIOR DETAILS
A211
TYPICAL ALL SINGLE LOCATIONS,
GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN
ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF
BASE CABINET PRIOR TO ORDERING.
1. PROVIDE A.W.I. CUSTOM GRADE, FLUSH-OVERLAY CABINETS.
FABRICATE WITH PLASTIC LAMINATE (PL1) COVERED M.D.O. BOARD
WITH 4" WIRE PULLS. COORDINATE WITH ELEVATIONS FOR QUANTITIES.
- AT BREAK ROOM & CONFERENCE PROVIDE:
24" DEEP COUNTERTOPS
23" DEEP BASE CABINETS
11
1
2" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS
- AT MAIL ROOM PROVIDE:
25" DEEP COUNTERTOPS
24" DEEP BASE CABINETS
11
1
2" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS
- 4" BASE AT CABINETS TO BE VINYL BASE AS SPECIFIED, UNLESS
NOTED OTHERWISE.
CASEWORK NOTES
CL CLOSER
CH COAT HOOK
CR CARD READER BY TENANT (N.I.C.)
DB DEADBOLT
DL DUMMY LEVER
EL ELECTROMAGNETIC LOCK (PER IBC 2012)
ES ELECTRIC STRIKE BY TENANT (N.I.C.)
H HOLD OPEN
KP KICK PLATE
KS KICK STOP
OL OFFICE LOCKSET
PH PANIC HARDWARE
PL PRIVACY LOCKSET
PP PUSH/PULL- SEE REMARKS FOR SPEC.
PS PASSAGE LATCHSET
PV PIVOT HINGE
RL ROLLER LATCHES
SL STOREROOM LOCKSET
TS TOP STRIKES
HARDWARE LEGEND
NOTE: REFER TO FLOORPLAN
AND CASEWORK ELEVATIONS
FOR SINK LOCATIONS.
DATE DESCRIPTION
ISSUE
02.16.18 REVIEW SET
02.20.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
AMERISURE
900 E. 96TH ST. - SUITE 275
INDIANAPOLIS, IN 46240
SDH KV
2017.362
2ND FLOOR
DOOR/FRAME TYPES
0 1' 2' 4'
ELEVATION - CONFERENCE 203
A211
3
0 3" 6" 1' 2'
COAT/ROD DETAIL
A211
2
NOT TO SCALE
RISER DIAGRAM
A211
1
D5 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING CR,ES,PP,CL
R1. PROVIDE ROCKWOOD POST MOUNT PULLS; ONE OF EACH SIDE OF
DOOR (QTY=2 PER DOOR)
R2. FINISH TENANT SIDE OF DOOR AND FRAME TO MATCH SUITE
STANDARD STAIN COLOR. FINISH CORRIDOR SIDE OF DOOR AND
FRAME TO MATCH BUILDING STANDARD STAIN COLOR IN PUBLIC
CORRIDORS.
R3. LONG LOCKING LADDER PULL (MATCH VACANCY DOWN THE
HALL).
D4 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING CR,ES,PP,CL
3'-0"x8'-0"x1
3
4" (PAIR) D3 RL, DL
REMARKS
DOOR/FRAME NOTES
1. REUSE DOORS FROM DEMOLITION WHERE POSSIBLE; TOUCH UP EXISTING
DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD DOORS
MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO MATCH
EXISTING. PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS.
2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE
EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW
DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD.
PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND
LATCHSETS.
3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE EXISTING
FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING REPAINTED,
TOUCH UP EXISTING FRAMES TO BE REUSED.
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS
UNLESS OTHERWISE NOTED ON PLAN.
5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND
LOCKSETS.
6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION,
PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC
AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL
SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA
BUILDING CODE, CHAPTER 10, MEANS OF EGRESS.
7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
· 7'-0" HT. TO HAVE 3 HINGES
· GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES
· FINISH TO MATCH HARDWARE SET
8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE
NOTED.
9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR
UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL
STOP.
TYPE MATERIAL FINISH TYPE MATERIAL FINISH
0 1' 2' 4'
ELEVATION - CONFERENCE 203
A211
4
D4 HERCULITE GLASS SYSTEM -- DRYWALL WRAPPED OPENING
D2
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
F3 TIMELY
MATCH
EXIST.
OL
D2
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
F3 TIMELY
MATCH
EXIST.
OL
D2
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
F3 TIMELY
MATCH
EXIST.
OL
D4 HERCULITE GLASS SYSTEM -- DRYWALL WRAPPED OPENING
D1
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
F1 TIMELY
MATCH
EXIST.
CR, ES, SL, CL
D1
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
F1 TIMELY
MATCH
EXIST.
CR, ES, SL, CL
D1
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
F1 TIMELY
MATCH
EXIST.
PS
D6
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST. F1 TIMELY
MATCH
EXIST.
CR, ES, SL, CL
3'-0"x8'-0"x1
3
4"
3'-0"x8'-0"x1
3
4"
3'-0"x8'-0"x1
3
4"
3'-0"x8'-0"x1
3
4"
3'-0"x8'-0"x1
3
4"
3'-0"x8'-0"x1
3
4"
3'-0"x8'-0"x1
3
4"
3'-0"x8'-0"x1
3
4"
3'-0"x8'-0"x1
3
4"
3'-0"xFULL HEIGHT
3'-0"xFULL HEIGHT
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
F2 TIMELY
MATCH
EXIST.
0 1' 2' 4'
ELEVATION - MAILROOM 210
A211
5
0 1' 2' 4'
ELEVATION -BREAK 213
A211
6
0 1' 2' 4'
ELEVATION -BREAK 213
A211
7
0 1' 2' 4'
ELEVATION -BREAK 213
A211
8
NOTE: AT DOOR (O1B), PORTION OF WALL IS ON ANGLE.
04/05/18
Nick Mishler