201
OPEN OFFICE
214
OFFICE
204
OFFICE
205
OFFICE
206
CONFERENCE
207
HW ETI OB RA D
HUDDLE
211
CONFERENCE
203
CLOSET
202
6x10
COPY
215
LF LF LF LF
6x8
6x8
6x8
6x8
6x8
6x8
6x8
6x8
6x8
6x8
6x8 6x8
6x8 6x8
COPY
212
MAILROOM
210
LAN
209
STORAGE
208
6x8
REFRIG
BY
TENANT
6x10
6x8 6x8
6x8
6x8
6x8
6x8
6x8
6x8 6x8
6x8 6x8
6x8 6x8
6x8
6x8
6x8
6x8
6x8
6x8
6x8
6x8
6x8 6x8
. C . U
G I R F E R
LF LF LF LF LF
6x8
6x8
REFRIG
BY
TENANT
MICRO
BREAK
213
DED
DED
+42"
+42"
DED
DED
+42"
GFCI
+42"
GFCI
DED
+42"
GFCI
+42"
+44"
+44"
P
P
P
P P P
J
J
P P
TV
+60"
+60"
DED
GFCI
GFCI
J
+46"
+46"
TV
+60"
+60"
TV
+60"
+60"
+44"
+44"
+72"
+72"
TV
DED
+60"
DED
+42"
GFCI
ELECTRICAL PLAN
E111
PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR
FOR CARD READER (CARD READER BY TENANT). COORDINATE
WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE
FOR MORE DETAILS.
COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE
SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S
FURNITURE VENDOR.
PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, (1)CENTERED
AT 42" A.F.F. AND (1) CENTERED AT 60" A.F.F.
PROVIDE POWER AND DATA AT 60" A.F.F. FOR TENANT'S WALL
MOUNTED TELEVISION. COORDINATE EXACT LOCATION WITH
TENANT.
PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE
FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS
FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU
DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO
ORDERING.
IF POSSIBLE, CONVERT EXISTING BLANK/OPEN BOX TO NEW
RECEPTACLE AS SHOWN. IF NOT POSSIBLE, REMOVE BLANK/OPEN
BOX AND PROVIDE NEW RECEPTACLE AT THIS LOCATION.
PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE FOR
TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION
WITH TENANT'S FURNITURE VENDOR. POWER POLE BY FURNITURE
VENDOR.
PROVIDE POWER AT THIS LOCATION FOR TENANT'S UC
REFRIGERATOR.
COORDINATE WITH TENANT ON REQUIREMENTS IN THIS AREA.
PROVIDE POWER AT THIS LOCATION FOR GARBAGE DISPOSAL.
PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION FROM
FLOOR CORE POKE THRU DEVICE TO WALL MOUNTED MONITOR(S)
OR CEILING MOUNTED PROJECTOR.
PROVIDE (2) FLIP POWER RECESSED GROMMETS, EQUALLY
SPACED AND CENTERED IN ISLAND. RECESSED POWER GROMMET
TO BE: DOUG MOCKETT-#PCS43/USB- FLIP-UP GROMMET (1
POWER/2 USB) IN METALLIC SILVER OR EQUAL.
PROVIDE POWER AND DATA AT 72" A.F.F. FOR TENANT'S WALL
MOUNTED TELEVISION. COORDINATE EXACT LOCATION WITH
TENANT.
CONFIRM OFFICE LAYOUT AND ELECTRICAL LOCATIONS WITH
TENANT IN THIS AREA PRIOR TO INSTALLATION.
PLAN NOTES
AREA NOT IN CONTRACT ELECTRICAL PLAN
AREA OF WORK
LEGEND
DATE DESCRIPTION
ISSUE
02.16.18 REVIEW SET
02.20.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
AMERISURE
900 E. 96TH ST. - SUITE 275
INDIANAPOLIS, IN 46240
SDH KV
2017.362
2ND FLOOR
N
0 2' 4' 8' 16'
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE.
REPLACE WITH NEW AS REQUIRED.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
GENERAL NOTES
DED
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
BOX, BLANK COVER PLATE
BOX, OPEN
BOX, BLANK COVER PLATE
BOX, OPEN
POWER POLE FOR
ELECTRICAL AND DATA.
PROVIDE JUNCTION BOX
ABOVE CEILING.
POWER AND DATA POLE
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DEDICATED CIRCUIT
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
GFCI GROUND FAULT CIRCUIT
INTERRUPT OUTLET
HEIGHT OF ELECTRICAL
OR DATA DEVICE
CEILING MOUNTED
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
J
J
B
O
J
+42"
04/05/18
Nick Mishler