Loading...
HomeMy WebLinkAboutAnsul SystemBURNETT FABRICATING 6904 EMERALD BAY LANE INDIANAPOLIS IN 46237 SWEET SKIES JET IN-FLIGHT CATERING 108 EAST CARMEL DRIVE CARMEL IN SIZE FSCM NO DWG REV KITCHEN FIRE SYSTEM 1 SCALE 3/8"=1' SHEET 1 OF 5 PRE-ENGINEERED SYSTEM SHOP DRAWING ONLY – NOT TO SCALE BUCKEYE KITCHEN MISTER BFR-10 THIS SYSTEM UTILIZES 7 of 10 POINTS 42" - 48" REMOTE PULL STATION SHALL BE INSTALLED 42" - 48" ABOVE THE FINISHED FLOOR AND A DISTANCE OF AT LEAST 10FT FROM THE HAZARD BUT NOT MORE THAN 20FT. IT SHALL BE INSTALLED IN THE PATH OF EXIT AND REQUIRE A MAXIMUM FORCE OF 40 LBS AND A MAXIMUM MOVEMENT OF 14" FOR ACTUATION DISCHARGE PIPING CONNECTION TO HORN STROBE OR F.A.C.P. ACTIVATES UPON SYSTEM DISCHARGE (SUPPLIED, INSTALLED AND WIRED BY OTHERS) CONNECTION TO MAKE UP AIR FAN, SHUT DOWN UPON ACTIVATION (CONNECTION BY OTHERS) BUCK EYE BFR-10 MECHANICAL GAS SHUT OFF VALVE CLASS K WET CHEMICAL EXTINGUISHER SHALL BE INSTALLED 42" - 48" ABOVE THE FINISHED FLOOR N-1HP 1 FLOW PT HAZARD QTY NOZZLE BAND COLOR PTS TOTAL MIN Nozzle Height MAX Nozzle Height BFR - 10 TANK GRIDDLE 1 1LP RED 1 1 24 48 CHAR BROILER 1 1HP BLUE 1 1 30 48 RANGE 1 2LP YELLOW 2 2 35 43 DUCT 1 2W WHITE 2 2 PLENUM 1 1HP BLUE 1 1 7 NOZZLE TABLE 150" PERIMETER MAX 12 FT LENGTH MAX 14"x14" DUCT 360 36" GRIDDLE 10 FT HOOD N-2W 2 FLOW PT BURNETT FABRICATING 6904 EMERALD BAY LANE INDIANAPOLIS IN 46237 SWEET SKIES JET IN-FLIGHT CATERING 108 EAST CARMEL DRIVE CARMEL IN SIZE FSCM NO DWG REV KITCHEN FIRE SYSTEM 1 SCALE 3/8"=1' SHEET 2 OF 5 ALL PENETRATIONS TO THE HOOD SHALL BE SEALED WITH AN APPROVED QUICK SEAL DEVICE GENERAL NOTES: 1.System shall be Pre-Engineered 2.System shall be manufactured by Buckeye Fire Equipment of Kings Mountain NC 3.Buckeye Kitchen Mister systems have the following Listings and Approvals: Underwriters Laboratories Inc, UL 300 / UL 1254, UL EX 6885 ISO-9001 Registered 4.System Temperature Limitations – 32F min / 120F Max 5.Installation requirements, nozzle limitations and design criteria shall comply with the Buckeye Fire Equipment, Kitchen Mister Technical Manual and all addendums as published by Buckeye Fire Equipment 6.Pipe and fittings shall be Schedule 40 Black, Chrome Plated or Stainless. Galvanized Pipe Shall Not Be Used. 7.All required electrical work shall be performed by others and is not included on this shop drawing. 8.All required plumbing work be performed by others and is not included on this shop drawing Minimum Piping Requirements Note: Minimum piping requirements only apply when protecting a wok, deep fat fryer or range. 1.Minimum number of elbows before the closest nozzle protecting a fryer, range or wok shall be five (5) 2.The minimum piping volume before the closest nozzle protecting a fryer, range or wok shall not be less than 360 ml 3.The total system pipe volume shall not be less than 660 ml for all cylinder sizes. 4.A system shall have a minimum of three (3) flow points. General Piping Requirements 1.All piping shall be 3/8” or 1/2” 2.Split piping and straight line piping are allowed on all system as long as the total piping parameters are not exceeded. 3.When the discharge piping is split, no nozzles can be installed before the split. 4.The maximum number of elbows allowed per system are: BRF-5 20 elbows maximum BRF-10/15/20 25 elbows maximum 5.The maximum number of elbows between any two nozzles is five(5) 6.The maximum vertical rise of the supply line is ten (10) feet; this is either the maximum elevation difference between tank outlet and the highest nozzle or tank outlet and the highest of lowest point in the piping systems. 7.The maximum vertical rise of any nozzle above the supply line is two (2) feet. 8.No traps are allowed in the piping system. 9.When different size piping is used in the same system, the largest diameter piping must be closest to the cylinder and sizes are to decrease as they reach the nozzle. So piping always runs from larger to smaller diameter 10.Elbows or swivel adaptors used at the nozzle for aiming DO NOT count toward the total elbows allowed per system or the number of elbows allowed between two (2) nozzles. 11.For the BRF-15 and BRF-20 only, the maximum volume of piping between the BURNETT FABRICATING 6904 EMERALD BAY LANE INDIANAPOLIS IN 46237 SWEET SKIES JET IN-FLIGHT CATERING 108 EAST CARMEL DRIVE CARMEL IN SIZE FSCM NO DWG REV KITCHEN FIRE SYSTEM 1 SCALE 3/8"=1' SHEET 3 OF 5 04/06/18 Nick Mishler BURNETT FABRICATING 6904 EMERALD BAY LANE INDIANAPOLIS IN 46237 SWEET SKIES JET IN-FLIGHT CATERING 108 EAST CARMEL DRIVE CARMEL IN SIZE FSCM NO DWG REV KITCHEN FIRE SYSTEM 1 SCALE 3/8"=1' SHEET 4 OF 5 04/06/18 Nick Mishler BURNETT FABRICATING 6904 EMERALD BAY LANE INDIANAPOLIS IN 46237 SWEET SKIES JET IN-FLIGHT CATERING 108 EAST CARMEL DRIVE CARMEL IN SIZE FSCM NO DWG REV KITCHEN FIRE SYSTEM 1 SCALE 3/8"=1' SHEET 5 OF 5 10' 78" 24" 51" EXHAUST FAN CURB MAKE UP FAN CURB EXHAUST FAN MAKE UP AIR UNIT INSULATED FLEX DUCT SUPPLY AIR 3" SPACER SHORT CIRCUIT EXHAUST HOOD 48 HINGE STAINLESS WALL PANEL THREADED STEEL ROD HANGERS 6" MIN EF EXHAUST FAN ON/OFF SHALL BE THEROSTATCALLY CONTROLLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCURS (WIRING BY OTHERS) UNISTRUT EXHAUST HOOD SYSTEM DESIGNED IN COMPLIANCE WITH IMC SECTIONS 506, 507 & 508 14"x14" 16 ga STEEL DUCT FULLY WELDED WITH 2 LAYERS OF FIRE WRAP FIRE WRAP FIRE WRAP 40" MIN 3/8" THREADED ROD 04/06/18 Nick Mishler nozzle nearest the supply line from one branch to the closest nozzle from the next branch shall not exceed 500 ml. 04/06/18 Nick Mishler 450 N-1LP 1 FLOW PT 36" RANGE HS MU 360 N-2LP 2 FLOW PT N-1HP 1 FLOW PT 36" CHAR BROILER 04/06/18 Nick Mishler