HomeMy WebLinkAboutA000.31900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2018
Suzette Schuette09/30/2016
RIGHT
Allison II
2377.300.00.CPM
LOT 67
03/15/2018
PLOTTED: March 15, 2018 / Prem Kumar / 2377-ALLISON II-CZ-BASE-EL-HR2M.DWG
A3-HR2M
3FB.1Heartland 2M3 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleSCALE:REAR ELEVATION1/8" = 1'-0"-
\A1;9'-1{\H0.750000x;\S1#8;}"
TOP OF PLATE
\A1;4'-8{\H0.750000x;\S1#8;}"TOP OF PLATE
TOP OF FOUNDATION
\A1;12'-2{\H0.750000x;\S1#8;}"\A1;HDR. HGT. TYP.\A1;3'-9{\H0.750000x;\S7#8;}"\PHDR. HGT. TYP.
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
TOP OF FOUNDATIONTOP OF FLOOR
TOP OF PLATETOP OF FLOOR
TOP OF PLATE6" FASCIA \PBOARD, PER SPEC
ROOF SHINGLES,\PPER SPEC
HORIZONTAL SIDING, PER SPEC \A1;9'-1{\H0.750000x;\S1#8;}"
\A1;8'-1{\H0.750000x;\S1#8;}"
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;8'-1{\H0.750000x;\S1#8;}"
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
TOP OF FOUNDATION
TOP OF PLATE
TOP OF PLATE
127127
SCALE:LEFT ELEVATION1/8" = 1'-0"-
124
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
127127
127
124
127
SCALE:FRONT ELEVATION1/4" = 1'-0"-
\A1;8'-1{\H0.750000x;\S1#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
TOP OF FOUNDATIONTOP OF FLOOR
TOP OF FLOOR
TOP OF PLATE
TOP OF PLATE
12
8" TRIM, PER SPEC
6" TRIM, PER SPEC
6" RAKE BOARD, PER SPEC6" FRIEZE, PER SPEC
ROOF SHINGLES, PER SPEC
HORIZONTAL SIDING, PER SPEC
FYPON #LV12X24, OR EQUIVALENT
BRICK SOLDIER, PER SPEC
3" TRIM ON 10" FRIEZE, PER SPEC
BOARD & BATTEN SIDING, PER SPEC
14" SHUTTERS, PER SPEC4" TRIM, PER SPEC
ROWLOCK SILL, PER SPECBRICK VENEER, PER SPEC
6" FASCIA BOARD, PER SPEC
6" TRIM, PER SPEC
101210 1210
12101210
1210
\A1;8'-1{\H0.750000x;\S1#8;}"\PAT GARAGE
SIMILARSIMILARCL-07AD 2.3
\A1;3'-2{\H0.750000x;\S7#8;}"
SCALE:ROOF PLAN1/8" = 1'-0"-
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
10:12
10:1210:12
7:12
7:12
7:12
PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION
4:12
10:1210:1210:12
7:12
\A1;20'-0"
\A1;7'-0"
"B"509ROOF AREA:SQ. FT.
"B"2031ROOF AREA:SQ. FT.
\A1;7'-0"
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ELEVATION HR2M
ROOF AREA "A"SQ FTG 2031 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 2.71 3.39 3.39 49.90 8 0
AT EAVE 4.06 3.39 3.40 50.10 0 49.00
TOTAL (MIN)6.77 6.77 6.79 100.00
3
HIGH -
RIDGE VENT 2.71 3.39 3.38 49.80 0 0 27.00
AT EAVE 4.06 3.39 3.40 50.20 0 49.00
TOTAL (MIN)6.77 6.77 6.78 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ROOF AREA "B"SQ FTG 509 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.68 0.85 0.85 48.41 2 0
AT EAVE 1.02 0.85 0.90 51.59 0 13.00
TOTAL (MIN)1.70 1.70 1.75 100.00
3
HIGH -
RIDGE VENT 0.68 0.85 0.88 49.22 0 0 7.00
AT EAVE 1.02 0.85 0.90 50.78 0 13.00
TOTAL (MIN)1.70 1.70 1.78 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
04/02/18
Adam Schriner