HomeMy WebLinkAbout6.02 Side Elevationã
BRICK and STONE LINTEL SCHEDULE
48" HIGHSPAN WINDOW
*STONE *BRICKAll Lintels: 4" Minimum bearing required each end
* Brick is based on 40psf and Stone is based on 60psf
** Any lintels not described by the above parameters shall be specifically designed.
LINTEL SIZE36" HIGH ABOVE
Up to 6'-0"
Up to 8'-3"
Up to 9'-3"
Up to 16'-3"
Up to 6'-0"
Up to 8'-3"
Up to 9'-3"
Up to 16'-3"
L7 x 4 x 38 L8 x 4 x 12 L8 x 4 x 12
L6 x 4 x 5 16
L5 x 3 12 x 5 16
L3 12 x 3 12 x 1 4
L7 x 4 x 38
**per Design
L5 x 3 12 x 516
L4 x 3 12 x 14
L7 x 4 x 38 **per Design
**per Design**per Design
L6 x 4 x 38
L8 x 4 x 12
----
----
---- ----
----
----
---- ----
----
----
----
----
----
----
----
----
TYPICAL TRIM:
6" FASCIA
8" FRIEZE
(ALL SIDES)
(FRONT ONLY, UNLESS OTHERWISE NOTED)
04/03/18
Adam Schriner