HomeMy WebLinkAbout Sewer/Water Permit/sSUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. Only one building may connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation, Sump, Downspouts or other storm water drains shall be interconnected to District's sanitary sewer
as addressed through our 1/1 Ordinance 12.08.08 and 1/1 Policy found on our website at www.ctrwd.org.
3. The existing sewer line from the building to the septic tank may only be used if it is located under a building
addition, patio, porch or paved driveway. Air test is required to show if acceptable for re -use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The district shall inspect ALL laterals. The owner or contractor shall notify the District prior to backfilling the
installed lateral so the District can make an inspection to determine compliance with the District's sewer use
ordinance. Lateral stubs shall remain capped until an inspector is on site. Final connection shall only be made
under direct supervision of a CTRWD inspector. If an inspection fails and a second inspection is required or the
contractor is not on site for the scheduled inspection, a fee of $100.00 will be assessed and must be paid prior to
the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a
public sewer, a septic tank "...shall be abandoned (pumped clean) and filled completely with earthen material or
stone in a safe and sanitary manner." Please contact the appropriate County Board of Health for further
information and to notify the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SDR 21,
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR26 OR BETTER ("FERNCO" OR SIMILAR FLEXIBLE COUPLINGS TYPICALLY NOT ALLOWED'
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERIAL:
IF CONNECTING INTO A LOW PRESSURE FORCE MAIN-
CTRWD must be contacted for explanation of allowable pumps and pump requirements
1.25" HDPE DR11 IPS (TYP.) connections are to be made with
(Polypropylene or Stainless Steel), Compression Fittings or Electrofusion
ALL PUMP CONNECTIONS
Pumps located more than 3' perpendicular to or run longitudinally along the building for more than 3' shall have a
cleanout installed and the pipe shall be transitioned to 6" SDR 35 pipe for connection into the pump station.
CLEAN OUTS ARE TO BE LOCATED NO MORE THAN THREE FEET FROM THE FOUNDATION AND FOR
GRAVITY LATERALS NO MORE THAN 100 FEET APART (please see Clean Out Details Type 2 and Type 3 for
multiple cleanout installation requirements).
CLEAN OUT CAP REQUIREMENTS: 6" PVC Threaded Caps
7. BEDDING - Use Number 8 crushed stone or Number 8 fractured face aggregate Number 8 stone backfill material
8. is to be placed from 6 inches below to 12 inches above the pipe The trench should be a minimum of 18 inches
wide (six inches on both sides of the pipe)
Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meetinc
9. SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by
the District and the District's engineer prior to installation.
10. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
11. Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
Additional information on District standards and specifications may be obtained from the District's office during
business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web
site at http://www.ctrwd.org.
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
10701 North College Avenue Suite A
12. Indianapolis, Indiana 46280
13. Phone (317)-844-9200 Fax (317)-844-9203
Septic effluent shall not be pumped out into the sanitary sewer system.
13.a Contractors shall lay 14 gauge -solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top.
14. All splicing of tone wire shall be reconnected using either a 3M splice kit model DBR/Y-6, King Innovation Dryconn
Direct Bury Lug Aqua catalog # 90220, or District Engineer approved equal
All exteriors structures and piping are subject to be tested and/or televised upon the Districts discretion.
15. Examples of structures that may be included are manholes, grit interceptors, pump pits, grease interceptors, etc.
Testing requirements are to verify that all structures are watertight and that they conform to the Districts 1/1 Policy.
Call before you dig. IUPPS 1-800-382-5544, 48 hours prior to digging.
Revised 11/11/2017 by RH
tutu iv. uoiiege Avenue suite A Indianapolis, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.ctrwd.org
Residential
SANITARY SEWER PERMIT
Permit Type Final Subdivision College Meadows
Project WO
ENG10202006
Section Number
Project Name
Division C
Lot Number
16 B
Project Developer
CTRWD
Address Number
10530
Lift Station 01 Carmel Creek Station
Address 2
Treatment Plant
Carmel WWTP
Street
Combs Avenue
Parcel Acreage
0.18
City
Indianapolis
EDU in Gallons
310
Zip Code
46280
County
Hamilton
Local Sewer Charge - District Contribution
0.00
Plan Review and Inspection
0.00
Builder
Habitat for Humanity
Application Fee
150.00
Phone Number
EDU Fee
1818.00
Owner
Interceptor Fee
733.50
Other Fees
0.00
Phone Number
Fees Due
2701.50
Occupant
Invoice Number
Phone Number
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during
"open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation
drains, or other sources of ground or stormwater, shall be permitted to enter the District's sanitary sewer system. The
District will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for
laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder)
will be responsible for damages to the District's sewer system. This includes damages to manholes, castings,
manhole lids and the like-, caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200
24 hours in advance. All new construction will be placed on billing two months after connection has been made or
when water is connected, whichever comes first.
The building has:
Grease Trap Slab Foundation YES
Grease Interceptor Crawl Space
Grit Interceptor Basement
Grinder Station
Water Service City of Carmel
Main ID:
Manhole IDs USN1H
Lid Elevation
First Floor Elevation
Basement Elevation
CM17-CM17A
CM-17
CM-17A DSMH
840.86 /
-
V4Y
831.74
/
836.17
836.17
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor -4.69 4.43: Ft.
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Not Applicable
I ne uistrict currently requires that an AI inspection is performed and a Certificate of Compliance is issued prior to
_Z8<—occupancy / sale of a properrty. Please review attached 1/1 Permit.
-- ----- - - -- -- ---
]� Manholes shall remain accessible at all times Buried manholes will be corrected by the Developer/Owner.
--- ------ ------ ---- ------
The proper -class -of cleanout must be Installed every 100 feet of lateral pipe measured from sewer main to structure.
------------ ------ ---
The terms of the conditional permit, if any, are listed below.
�(TLPIans have been submitted.
II fees have been paid.
A certificate of insurance with the district named as certificate holder is required.
NEED A RIGHT-OF-WAY PERMIT
- k�- No manhole core permit required.
The facility is not classified as a FOG facility.
(Notes)
By signing below, I attest that I am farrfjfxr with Disir CT's specifications and agree to accept responsibility for all work do a un fer this permit.
Builder / Owner Signature_ �� — --- Phone Number _ .26 � —
Printed Name*�an
Approved ByR® s ctEngineer 04/02/2018
Permit is valid fAR from the date issued. Permit valid only with CTRWD seal in red ink.