HomeMy WebLinkAboutTRUSS DRAWINGSRe:
The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision
based on the parameters provided by Timberland Home Center-Brazil, IN.
Liu, Xuegang
Pages or sheets covered by this seal: I30273009 thru I30273104
My license renewal date for the state of Indiana is July 31, 2018.
REAGAN_MODEL
Truss Engineer’s responsibility is solely for
design of individual trusses based upon design parameters shown
on referenced truss drawings. Parameters have not been verified
as appropriate for any use. Any location identification specified is
for file reference only and has not been used in preparing design.
Suitability of truss designs for any particular building is the
responsibility of the building designer, not the Truss Engineer,
per ANSI/TPI-1, Chapter 2.
IMPORTANT NOTE:
REAGAN S
16023 Swingley Ridge Rd
Chesterfield, MO 63017
314-434-1200
MiTek USA, Inc.
June 26,2017
Job
REAGAN_MODEL
Truss
A1
Truss Type
Roof Special Supported Gable
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273009
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:36:58 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-KPlkQ9Q54FYKsAhfEHqnz5MUu0TFAEXr5v7cE6z2SFp
Scale = 1:58.0
1
2
3
4
5
6
7
8
9
10
11
22
21
20 19 18 17 16 15
14
13
12
4x6
4x4
4x6
3x4
2x4 2x4 3x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
4-3-8
4-3-8
12-10-8
8-7-0
17-2-0
4-3-8
-1-0-0
1-0-0
8-7-0
8-7-0
17-2-0
Job
REAGAN_MODEL
Truss
A2
Truss Type
Roof Special
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273010
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:00 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-HnsUrrSMcto25Ur1MisF2WRmJq_Ke7c8ZCciJ?z2SFn
Scale = 1:57.4
1
2
3
4
5
6
7
8
9
11 10
12
13 14
15
16 17
4x4
4x6
3x4
3x4
5x8 5x8
4x6
3x4
3x4
2x4 2x4
4-3-8
4-3-8
12-10-8
8-7-0
17-2-0
4-3-8
-1-0-0
1-0-0
4-3-8
4-3-8
8-7-0
4-3-8
12-10-8
4-3-8
17-2-0
4-3-8
18-2-0
1-0-0
0-9-7
9-4-7
0-9-7
Job
REAGAN_MODEL
Truss
B1
Truss Type
Roof Special
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273011
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:01 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-l_Qs3BT_MAwvjdQEwPNUbj_uiDNNNYLHnsLGrRz2SFm
Scale = 1:57.4
1
2
3
4
5
6
7
8
9
10
11
15 14 13 12
16
17
18
19
20
21
4x6
4x4
4x4
4x6
4x4
5x6
5x6
4x6
3x4
3x4
3x4
3x4
3x10
3x4
4-0-0
4-0-0
4-3-8
0-3-8
5-8-0
1-4-8
5-11-8
0-3-8
10-3-0
4-3-8
14-6-8
4-3-8
Job
REAGAN_MODEL
Truss
C1
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273012
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:03 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-hMYdUtUEuoAdyxZc1qPyg83DA1yJrQeaFAqNvJz2SFk
Scale = 1:88.9
1
2
3
4
5 6 7 8 9 10
11
12
20 19 18 17 16
15
14
13
21
22
23
24
25 26 27 28 29 30
31
32
33 34 35 36 37 38
39 40
3x6
6x8 4x8
5x6
3x4
5x6
3x6
3x4
2x4
3x4
2x4
3x4
3x4 4x4
10x12
4x4
5x12 MT20HS
4x6 4x8
8-10-7
8-10-7
17-8-2
8-9-11
26-5-13
8-9-11
35-3-8
8-9-11
Job
REAGAN_MODEL
Truss
C2
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273013
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:05 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-dlgNuZWUQPRKCFj?9FSQlZ9T0rgeJGNtiUJT_Cz2SFi
Scale = 1:89.9
1
2
3
4
5 6 7 8 9
10
11
12
21 20
19 18 17
16
15
14
23 13
24
25
26
27 28 29 30
31
32 33 34
35 36
22
3x6
6x8 3x6
5x6
3x6
6x8
3x6
2x4
2x4
8x8 4x6
3x4
2x4
3x4
5x8
4x4
4x4
3x10
4x4
4x6
3x4
6-10-5
6-10-5
13-7-15
Job
REAGAN_MODEL
Truss
C3
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273014
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:07 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-a8n7JEXly0h2RYtOGgUur_EpVeL6n9tAAooa25z2SFg
Scale = 1:89.9
1
2
3
4
5 6 7 8 9
10
11
12
21 20
19 18 17
16
15
14
23 13
24
25
26
27 28 29 30
31
32 33 34
35 36
22
3x6
6x8 3x6
5x6
3x6
6x8
3x6
2x4
2x4
8x8 4x6
3x4
2x4
3x4
5x8
4x4
4x4
3x10
4x4
4x6
3x4
6-10-5
6-10-5
13-7-15
Job
REAGAN_MODEL
Truss
C4
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273015
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:09 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-WWvukwZ?Uexmgs1mO5WMwPJBSS?iF0VTd6Hh7zz2SFe
Scale = 1:84.0
1
2
3
4
5 6 7
8 9 10
11
12
20 19 18 17
16
15
14 13
21
22
23
24
25 26 27 28
29
30
31 32 33 34
35 36
3x6
6x8 3x6
5x6
4x4
5x6
4x6
3x4
2x4
6x8 4x6
3x4
2x4
5x8
4x4 4x4
3x10
4x6
4x4
8-8-13
8-8-13
17-4-14
8-8-1
26-0-15
8-8-1
34-8-1
Job
REAGAN_MODEL
Truss
C5
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273016
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:10 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-_iTGyGadFx3dI0cyxo1bScsPYsNV_WIcsm1EfPz2SFd
Scale = 1:87.5
1
2
3
4
5 6 7
8 9 10
11
12
20 19 18 17
16
15 14 13
21
22
23
24
25 26 27 28 29
30
31
32 33 34
35 36 37 38
3x6
6x8 3x6
5x6
4x4
5x6
3x6
2x4
2x4
8x8 5x6 WB
4x4
2x4
5x8
4x4
3x4
3x10
4x6
3x6
8-1-8
8-1-8
16-2-4
8-0-12
24-3-0
8-0-12
33-8-4
Job
REAGAN_MODEL
Truss
D1
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273017
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:12 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-w5b0MybtnZJLXKlL3D43X1xlyf2DSQWvJ4WLkIz2SFb
Scale = 1:68.0
1
2 3
4
5 6 7 8 9
10
19 18 17
16
15
14 13 12 11
20 21
22
23
2425 26 27 28 29
30 31
32 33 34 35
2x4
5x6 5x6
5x6 3x6
5x6
2x4
3x6
4x6 4x6
4x6
3x10
3x4
3x4
3x4
4x6
4x4
3x6 4x6
1-2-13
1-2-13
5-5-13
4-2-15
13-4-7
7-10-10
21-2-4
7-9-13
29-0-2
7-9-14
37-1-8
8-1-6
1-2-13
1-2-13
Job
REAGAN_MODEL
Truss
D2
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273018
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:14 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-tUjnned8JAZ3ndvkAe6XdS05VTpowK8CnO?SoBz2SFZ
Scale = 1:67.5
1
2 3
4 5 6 7 8
9
16 15
14 13 12 11 10
17
18
19
20
21 22 23 24 25 26
27 28 29 30 31 32
2x4
5x6 5x6
5x12 MT20HS
3x6
5x6
2x4
5x8 4x6
3x4
3x4 2x4
4x4 4x6 4x8 4x6
7-10-9
7-10-9
17-6-6
9-7-13
27-2-3
9-7-13
37-1-8
9-11-5
2-11-3
2-11-3
7-10-9
4-11-6
13-4-7
5-5-14
20-4-8
7-0-1
27-4-8
7-0-1
34-4-9
7-0-1
37-1-8
2-8-15
Job
REAGAN_MODEL
Truss
D3
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273019
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:16 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-psqXCJeOqnpn0x36I38?it6QVGQYODLUEiUZt3z2SFX
Scale = 1:82.1
1
2
3 4
5 6 7 8 9
10
11
12
13
23 22 21
20 19 18 17
16
15 14
24
25 26
27
28 29 30 31 32
33
34
35 36 37 38
39 40 41 42
2x4
5x6
5x6 5x6
5x12 MT20HS
3x6
5x6
5x6
3x6
2x4
4x8 2x4
3x10
3x10
3x4
3x4
3x4
4x6
4x8
4x4
4x6
3x6
4-7-9
4-7-9
13-4-7
8-8-13
Job
REAGAN_MODEL
Truss
D3
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273019
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:16 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-psqXCJeOqnpn0x36I38?it6QVGQYODLUEiUZt3z2SFX
NOTES-
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
D4
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273020
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:19 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-DRWgqLhG7iBLtOohzBiiKWkz2USUbZAxwgiDUOz2SFU
Scale = 1:94.0
1
2
3
4 5
6 7 8 9 10
11
13
14
25 24 23 22 21 20 19
18
17 16 15
26
27 28
29 30 31 32 33 34
35
36
37 38 39
40 41 42 43 44
2x4
5x6
5x6
8x12 MT20HS 5x6
5x8
3x6
5x6
5x6
3x6
2x4
2x4 2x4
3x10
4x8
3x10
2x4
3x4
4x6
8x10
4x4
4x6
3x10
3x6
6-3-15
6-3-15
12-8-2
6-4-2
Job
REAGAN_MODEL
Truss
D4
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273020
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:19 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-DRWgqLhG7iBLtOohzBiiKWkz2USUbZAxwgiDUOz2SFU
NOTES-
12) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 15. This connection is for uplift only and does not
consider lateral forces.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
D5
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273021
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:21 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-9qeQF1iXfKS36ix45ckAPxpJYH8z3TgEO_BKYHz2SFS
Scale = 1:85.7
1
2
3
4 5
6 7 8 9 10
11
12
13
14
25 24 23 22 21 20 19
18
17 16 15
26
27 28
29 30 31 32 33 34
35
36
37 38 39
40 41 42 43 44
2x4
5x6
5x6
8x12 MT20HS
5x6
5x8
3x6
5x6
5x6
3x6
2x4
2x4 2x4
3x10
4x8
3x10
2x4 3x4
4x6
8x10
4x4
4x6
3x10
3x6
6-3-15
6-3-15
12-8-4
Job
REAGAN_MODEL
Truss
D5
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273021
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:22 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-e0CoTNj9QdawksWGeKFPx8MUIhUCowwNcext4jz2SFR
NOTES-
12) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 15. This connection is for uplift only and does not
consider lateral forces.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
D6
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273022
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:24 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-aPJZu2lPyFqezAgfmkHt1ZRnUV9cGqyg4xQ_9bz2SFP
Scale = 1:84.0
1
2
3 4
5 6 7 8 9
10
11
12
13
24 23 22
21 20 19 18
17
16 15 14
25
26 27
28
29 30 31 32 33
34
35
36 37 38 39
40 41 42 43
2x4
5x6
5x6 5x6
5x6 3x6
5x6
5x6
3x6
2x4
2x4 3x6
3x10
3x10
3x4
3x4
3x4
4x6
8x10
4x4
4x6
3x10
3x6
4-7-9
4-7-9
13-4-7
8-8-14
Job
REAGAN_MODEL
Truss
D7
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273023
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:25 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-2btx5Ol1jYyVbKFrKSp6Zn_w7vVq?IzpJb9Xh2z2SFO
Scale = 1:62.0
1
2 3
4 5 6 7 8
15 14
13 12 11 10
9
16
17
18
19 20 21 22
23 24 25 26 27 28
2x4
5x6 5x6
8x8 4x4 3x4
4x6 4x6
4x8
3x4
3x4
3x4
4x4
4x4 3x4
7-10-9
7-10-9
15-11-9
8-1-0
24-0-8
8-0-15
32-5-0
8-4-8
2-11-2
2-11-2
7-10-9
4-11-7
13-4-7
5-5-13
19-7-7
6-3-0
25-10-7
6-3-0
32-5-0
6-6-8
2-5-13
4-5-1
9-0-0
Job
REAGAN_MODEL
Truss
D8
Truss Type
Piggyback Base
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273024
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:27 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-__?hW4nHFACDqdPERtraeC3GYiCbTCM6mveemwz2SFM
Scale = 1:62.1
1
2 3
4
5 6 7 8
9
16 15
14
13
12 11
10
17
18
19
20
21 22 23 24
25 26 27 28 29 30
2x4
5x6 5x8
4x6 4x4 3x4
4x4 4x4
5x10
4x6
3x10
3x4
3x4
4x4
3x4 4x6
5-5-12
5-5-12
13-4-7
7-10-11
22-8-15
9-4-9
32-5-0
9-8-1
1-2-12
1-2-12
5-5-12
4-3-0
9-5-1
3-11-5
13-4-7
3-11-5
19-7-7
Job
REAGAN_MODEL
Truss
E1
Truss Type
Piggyback Base
Qty
4
Ply
1
REAGAN S
Job Reference (optional)
I30273025
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:28 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-SAZ3jQow0TK4Sn_Q?aMpBPbPG6YXCeXG?ZOBINz2SFL
Scale = 1:73.5
12
3
4
5 6 7
8 9 10
16 15 14 13
12
11
17
18
19
20 21
22 23 24 25
26 27
3x4
6x8 3x4 2x4
4x4
4x6
3x4 2x4
2x4
8x8
4x4
2x4
3x10
3x4
4x4
7-9-8
7-9-8
15-6-4
7-8-12
23-3-0
7-8-12
32-8-8
9-5-8
-1-0-0
1-0-0
6-10-5
6-10-5
13-7-15
6-9-9
18-5-7
4-9-9
23-3-0
4-9-9
Job
REAGAN_MODEL
Truss
F1
Truss Type
Attic
Qty
4
Ply
1
REAGAN S
Job Reference (optional)
I30273026
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:29 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-wM7SxmoYmnSx4xZcZIt2kd8bEWr2xCGPDD7lqpz2SFK
Scale = 1:76.7
1
2
3
4
5
6
7
8
9
10
11
12
13
17 16 15 14
18
19
20 21
22
6x8
6x8
6x8
5x8
4x6
3x6
10x12
3x10
3x6 3x6
3x10
10x12
4x6
3x6
2x4
5x8
13-6-0
6-5-0
3-6-7
2-3-11
2-3-11
4-1-4
1-9-9
11-0-0
6-10-12
17-10-12
6-10-12
Job
REAGAN_MODEL
Truss
F2
Truss Type
Attic
Qty
3
Ply
1
REAGAN S
Job Reference (optional)
I30273027
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:31 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-tlECMSqoIOieJFi?givWp2DwgJWYP6aihXcrviz2SFI
Scale = 1:76.7
1
2
3
4
5
6
7
8
9
10
11
12
16 15 14 13
17
18
19 20
21
22
6x8
6x8
6x8
5x8
4x6
3x6
10x12
3x10
3x6
3x6
3x10
10x12
4x6
3x6
2x4
5x8
13-6-0
6-5-0
2-4-15
2-4-15
4-1-4
1-8-5
11-0-0
6-10-12
17-10-12
6-10-12
Job
REAGAN_MODEL
Truss
G1
Truss Type
Roof Special Girder
Qty
1
Ply
3
REAGAN S
Job Reference (optional)
I30273028
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:33 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-p8Myn7s2q?yMZYsNo7y_uTJIQ7Dytwr?8r5yzaz2SFG
Scale = 1:58.3
1
2
3
4
5
6
7
8
9
10
15 14 13 12
11
16
17
18
19
20
21 22 23 24
25
10x12 MT20HS
8x12 MT20HS
5x10
5x10 5x10
4x8
10x20 10x12
10x12
5x8
12x20
4x6
3x4
3x6
Special
HUS26
Special
HUS26
HUS26
Special
Special
1-10-10
1-10-10
2-3-10
0-5-0
3-5-7
1-1-13
Job
REAGAN_MODEL
Truss
G1
Truss Type
Roof Special Girder
Qty
1
Ply
3
REAGAN S
Job Reference (optional)
I30273028
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:33 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-p8Myn7s2q?yMZYsNo7y_uTJIQ7Dytwr?8r5yzaz2SFG
NOTES-
11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and
any other members.
12) WARNING: Required bearing size at joint(s) 10, 2 greater than input bearing size.
13) Bearing at joint(s) 10, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
14) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This connection is for uplift only and does not
consider lateral forces.
15) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16) Use Simpson Strong-Tie HUS26 (14-10d Girder, 6-10d Truss) or equivalent at 8-0-12 from the left end to connect truss(es) to back face of bottom chord.
17) Use Simpson Strong-Tie HUS26 (14-10d Girder, 6-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 12-0-12 from the left end to 14-0-12 to
connect truss(es) to back face of bottom chord.
18) Fill all nail holes where hanger is in contact with lumber.
19) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 5048 lb down and 1497 lb up at 6-1-8, 2065 lb down at 10-0-12, and
2009 lb down at 16-0-12, and 2013 lb down at 18-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-4=-60, 4-5=-60, 5-7=-60, 7-10=-60, 2-15=-20, 12-15=-20, 10-12=-20
Concentrated Loads (lb)
Vert: 14=-5048(B) 13=-2065(B) 21=-2142(B) 22=-1987(B) 23=-2013(B) 24=-2009(B) 25=-2013(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G2
Truss Type
Hip Girder
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273029
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:47 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-PqCFjw0qXJjNEix4c4CGSQulPm?U9CG3M0UiTmz2SF2
Scale = 1:80.6
12
3
4 5 6 7
8 9 10 11
12 13 14
15
29 28 27
26
25 24
23
22 21 20
19
18 17 16
30 31 32
33 34 35 36 37 38 39 40 41
42 43 44 45 46
47 48 49 50
3x6
5x6
4x6
4x8
6x8
4x4
2x4
8x10
5x12 MT20HS
3x4
3x6 4x6 5x8
6x12 MT20HS
2x4 3x10
3x6 4x8
2x4
3x6
3x10 3x4
8x10
3x6
6x8
3x6 5x8
6x8
LU24
LU24 LU24 LU24
LU24
LU24 LU24
LU24
Job
REAGAN_MODEL
Truss
G2
Truss Type
Hip Girder
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273029
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:47 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-PqCFjw0qXJjNEix4c4CGSQulPm?U9CG3M0UiTmz2SF2
NOTES-
10) The Fabrication Tolerance at joint 4 = 0%
11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and
any other members.
12) WARNING: Required bearing size at joint(s) 2 greater than input bearing size.
13) Refer to girder(s) for truss to truss connections.
14) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 16=1477.
15) Two RT16-2 USP connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This connection is for uplift only and does not consider lateral
forces.
16) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
17) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss, Single Ply Girder) or equivalent spaced at 4-0-12 oc max. starting at 2-0-12 from the left end to 41-9-12
to connect truss(es) to front face of bottom chord.
18) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss) or equivalent spaced at 3-4-8 oc max. starting at 18-5-4 from the left end to 21-9-12 to connect truss(es)
to front face of bottom chord.
19) Fill all nail holes where hanger is in contact with lumber.
20) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 221 lb down and 142 lb up at 16-5-4 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-4=-60, 4-14=-60, 14-15=-60, 2-20=-20, 16-19=-20
Concentrated Loads (lb)
Vert: 26=-222(F) 27=-222(F) 25=-221(F) 22=-222(F) 33=-403(F) 34=-316(F) 35=-283(F) 36=-222(F) 37=-222(F) 38=-222(F) 39=-444(F) 40=-410(F) 41=-444(F)
42=-221(F) 43=-222(F) 44=-222(F) 45=-222(F) 46=-222(F) 47=-223(F) 48=-223(F) 49=-223(F) 50=-299(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G3
Truss Type
Roof Special Girder
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273030
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:48 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-t0mdwG1TIcrEssWGAnjV?dQxiAXbusXCbgEF?Cz2SF1
Scale = 1:40.7
1
2
3
4
5
7 6
8
9
10
11
4x4
4x4
2x4
4x4
3x6
TJC37 3x4
3-10-0
3-10-0
7-10-0
4-0-0
-1-0-0
1-0-0
2-0-0
2-0-0
3-10-0
1-10-0
7-10-0
4-0-0
0-9-7
2-9-7
6-9-7
2-9-7
12.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-0-9], [3:0-2-8,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
Job
REAGAN_MODEL
Truss
G3
Truss Type
Roof Special Girder
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273030
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:48 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-t0mdwG1TIcrEssWGAnjV?dQxiAXbusXCbgEF?Cz2SF1
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-4=-60, 4-5=-60, 2-6=-20
Concentrated Loads (lb)
Vert: 11=-40(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G4
Truss Type
Half Hip Girder
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273031
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:49 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-LDK07c253wz5T04SkUEkXrz2RasFdKNLqKzoXfz2SF0
Scale = 1:15.1
1
2
3 4
6 7 8 5
4x8 2x4
4x6 4x4
2x4
TJC37
Special LU24
1-4-1
1-4-1
6-0-0
4-7-15
-1-0-0
1-0-0
1-4-1
1-4-1
6-0-0
4-7-15
0-9-7
2-1-7
12.00 12
Plate Offsets (X,Y)-- [2:Edge,0-1-1], [3:0-6-8,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
Job
REAGAN_MODEL
Truss
G4
Truss Type
Half Hip Girder
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273031
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:49 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-LDK07c253wz5T04SkUEkXrz2RasFdKNLqKzoXfz2SF0
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-4=-60, 2-5=-20
Concentrated Loads (lb)
Vert: 6=-14(B) 7=-38(B) 8=-38(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G5
Truss Type
Piggyback Base Girder
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273032
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:52 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-lo08md4zMrMgKTp1PdoR9TbX0niHqUuoWICT7_z2SEz
Scale = 1:88.4
1
2
3
4
5 6 7 8 9 10
11
12
22 21 20
19
18
17
16
15 14 13
23
24
25 26 27 28
29
30 31 32
33 34 35 36
3x6
6x8 3x6
8x8
5x10
7x12 MT20HS
3x6 2x4
2x4
10x12 6x8
4x4
2x4
5x8
4x6
2x4
3x10
5x8
4x4
10x12
4x8
HUS28 LU24
LU24
8-3-2
8-3-2
16-3-1
7-11-15
24-3-0
Job
REAGAN_MODEL
Truss
G5
Truss Type
Piggyback Base Girder
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273032
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:52 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-lo08md4zMrMgKTp1PdoR9TbX0niHqUuoWICT7_z2SEz
NOTES-
12) H10A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This connection is for uplift only and does not consider
lateral forces.
13) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 13. This connection is for uplift only and does not
consider lateral forces.
14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
15) Use Simpson Strong-Tie HUS28 (22-10d Girder, 8-10d Truss, Single Ply Girder) or equivalent at 37-5-12 from the left end to connect truss(es) to back face of bottom
chord.
16) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 39-4-4 from the left end to 41-4-4 to
connect truss(es) to back face of bottom chord.
17) Fill all nail holes where hanger is in contact with lumber.
18) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-5=-60, 5-10=-60, 10-12=-60, 2-19=-20, 13-18=-20
Concentrated Loads (lb)
Vert: 14=-2171(B) 35=-199(B) 36=-199(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G6
Truss Type
Roof Special Girder
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273033
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:54 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-iA7vBJ6DuScNanzQW2qvEugwAbQAIZc4zchZCsz2SEx
Scale = 1:30.5
1
2
3
4
5 6
7
8
9
17 16 15
14 13 12 11 10
18 19
20 21 22 23 24 25 26 27
5x8
5x8
4x6
5x8
5x8
8x12 WB
3x4
3x6 8x8 8x8 6x8 6x8
3x4
3x6
6x10 HUS26 8x8
HUS26 HUS26
HUS26 HUS26 HUS26
TJC37 HUS26 HUS26
TJC37
TJC37
TJC37 TJC37
LU24 TJC37
TJC37 TJC37
TJC37
TJC37
0-2-4
0-2-4
0-3-10
0-1-6
2-2-7
1-10-13
4-1-6
1-10-15
6-6-9
2-5-3
8-6-12
Job
REAGAN_MODEL
Truss
G6
Truss Type
Roof Special Girder
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273033
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:55 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-ANhHOf7sfmkEBxYc4lL8n6D5w?mP10sECGQ7kIz2SEw
NOTES-
12) Use Simpson Strong-Tie TJC37 (4 nail 90-150) or equivalent at 4-1-6 from the left end to connect truss(es) to back face of bottom chord, skewed 30.7 deg.to the right,
sloping 0.0 deg. down.
13) Use Simpson Strong-Tie TJC37 (4 nail 90-150) or equivalent at 5-4-11 from the left end to connect truss(es) to back face of bottom chord, skewed 22.9 deg.to the right,
sloping 0.0 deg. down.
14) Use Simpson Strong-Tie TJC37 (4 nail 90-150) or equivalent at 6-6-9 from the left end to connect truss(es) to back face of bottom chord, skewed 15.0 deg.to the right,
sloping 0.0 deg. down.
15) Use Simpson Strong-Tie TJC37 (4 nail 90-150) or equivalent at 7-5-15 from the left end to connect truss(es) to back face of bottom chord, skewed 6.5 deg.to the right,
sloping 0.0 deg. down.
16) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss, Single Ply Girder) or equivalent at 8-6-12 from the left end to connect truss(es) to back face of bottom
chord, skewed 0.0 deg.to the left, sloping 0.0 deg. down.
17) Use Simpson Strong-Tie TJC37 (4 nail, 30-90) or equivalent at 9-7-9 from the left end to connect truss(es) to back face of bottom chord, skewed 6.5 deg.to the left,
sloping 0.0 deg. down.
18) Use Simpson Strong-Tie TJC37 (4 nail, 30-90) or equivalent at 10-6-14 from the left end to connect truss(es) to back face of bottom chord, skewed 15.1 deg.to the left,
sloping 0.0 deg. down.
19) Use Simpson Strong-Tie TJC37 (4 nail, 30-90) or equivalent at 11-8-12 from the left end to connect truss(es) to back face of bottom chord, skewed 23.0 deg.to the left,
sloping 0.0 deg. down.
20) Use Simpson Strong-Tie TJC37 (4 nail, 30-90) or equivalent at 13-0-2 from the left end to connect truss(es) to back face of bottom chord, skewed 30.8 deg.to the left,
sloping 0.0 deg. down.
21) Use Simpson Strong-Tie TJC37 (4 nail, 30-90) or equivalent at 14-7-11 from the left end to connect truss(es) to back face of bottom chord, skewed 33.5 deg.to the left,
sloping 0.0 deg. down.
22) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-4=-60, 4-5=-60, 5-6=-60, 6-7=-60, 7-9=-60, 1-9=-20
Concentrated Loads (lb)
Vert: 17=1(B) 16=-36(B) 14=-74(B) 13=-86(B) 12=-75(B) 11=-36(B) 10=1(B) 20=-1520(F) 21=-1520(F) 22=-1563(F=-1510, B=-54) 23=-1566(F=-1486, B=-80)
24=-1566(F=-1486, B=-80) 25=-1528(F=-1475, B=-54) 26=-1268(F) 27=-1272(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G7
Truss Type
Jack-Closed Girder
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273034
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:55 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-ANhHOf7sfmkEBxYc4lL8n6D8w?kS1vQECGQ7kIz2SEw
Scale = 1:38.7
1
2
3
5
4
6
7 8
5x6
2x4
4x6
4x6
5x10
HUS28
HUS28
2-9-4
2-9-4
5-6-8
2-9-4
2-9-4
2-9-4
5-6-8
2-9-4
0-9-7
6-3-15
12.00 12
Plate Offsets (X,Y)-- [1:0-0-0,0-0-6], [2:0-1-0,0-1-8], [4:0-3-0,0-2-4], [5:0-6-4,0-2-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
Job
REAGAN_MODEL
Truss
G8
Truss Type
Roof Special Girder
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273035
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:57 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-6lp1pL86AN_yREi?CANcsXIStoQOVsYXgavDoBz2SEu
Scale = 1:58.1
1
2
3
4
5
6
7
8
9
15 10
14
13 12 11
16
17
18
19
4x4
4x4
4x4
8x8
6x12 MT20HS
5x6 5x6
4x6
3x4
3x4
5x10
3x10
3x4
3x6
3x10
Special
2-0-0
2-0-0
3-8-0
1-8-0
5-11-8
2-3-8
10-3-0
4-3-8
14-6-8
4-3-8
18-10-0
4-3-8
-1-0-0
Job
REAGAN_MODEL
Truss
G8
Truss Type
Roof Special Girder
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273035
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:57 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-6lp1pL86AN_yREi?CANcsXIStoQOVsYXgavDoBz2SEu
NOTES-
14) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-4=-60, 4-6=-60, 6-10=-60, 2-15=-20, 14-15=-20, 13-14=-20, 11-13=-20, 9-11=-20
Concentrated Loads (lb)
Vert: 3=-1(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G9
Truss Type
Half Hip Girder
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273036
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:59 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-28xoE0AMi?EggYrNJbQ4xyOr7cAzze5q7uOKt4z2SEs
Scale = 1:57.8
1
2
3
4 5 6 7
8 9 10
19 18
17
16 15
14
13 12 11
20
21 22
23 24 25 26 27 28 29 30 31 32
33 34 35 36
37
4x8 3x4 2x4
6x8
4x6
4x6
3x4
2x4 3x4 3x10
2x4
2x4
3x10 2x4
4x8 2x4
4x8
LU24 4x6
LU24
LU24
LU24 LU24
LU24
LU24 LU24
LU24
LU24
LU24
LU24 LU24
LU24
LU24
LU24
3-8-11
3-8-11
7-2-4
3-5-9
12-4-9
Job
REAGAN_MODEL
Truss
G9
Truss Type
Half Hip Girder
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273036
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:59 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-28xoE0AMi?EggYrNJbQ4xyOr7cAzze5q7uOKt4z2SEs
NOTES-
12) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss) or equivalent at 2-0-12 from the left end to connect truss(es) to back face of bottom chord.
13) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 4-0-12 from the left end to 32-0-12 to
connect truss(es) to back face of bottom chord.
14) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-4=-60, 4-10=-60, 2-11=-20
Concentrated Loads (lb)
Vert: 17=-222(B) 23=-403(B) 24=-316(B) 25=-283(B) 26=-222(B) 27=-222(B) 28=-222(B) 29=-222(B) 30=-221(B) 31=-221(B) 32=-221(B) 33=-221(B) 34=-221(B)
35=-221(B) 36=-221(B) 37=-226(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G10
Truss Type
Hip Girder
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273037
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:35 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-lWUjBptJMdC4os0mvY_SzuOmGx_QL_XHc9a32Tz2SFE
Scale = 1:44.3
1
2
3 4 5
6
7
8
14 13
12
11 10 9
15
16 17
18
19 20 21 22 23 24 25 26 27 28 29 30
4x6
4x8 4x8
4x6
3x4
2x4 3x4 3x10
2x4
3x4
3x4
2x4
4x6
LU24
LU24
LU24
LU24 LU24 LU24 LU24
LU24
LU24
LU24
3-10-5
3-10-5
7-5-6
3-7-2
10-6-0
3-0-10
13-6-10
3-0-10
17-1-11
3-7-2
21-0-0
3-10-5
3-10-5
3-10-5
Job
REAGAN_MODEL
Truss
G10
Truss Type
Hip Girder
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273037
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:35 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-lWUjBptJMdC4os0mvY_SzuOmGx_QL_XHc9a32Tz2SFE
NOTES-
13) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 4-0-12 from the left end to 16-11-4 to
connect truss(es) to back face of bottom chord.
14) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-5=-60, 5-8=-60, 1-7=-20
Concentrated Loads (lb)
Vert: 12=-210 14=-319(B) 9=-319(B) 19=-210 20=-406(B) 21=-210 22=-210 23=-283(B) 24=-210 25=-224(B) 26=-224(B) 27=-434(B=-224) 28=-434(B=-224)
29=-493(B=-283) 30=-406(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G11
Truss Type
Attic Girder
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273038
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:37 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-hvcTcVvZuETo1AA91z0w2JT9lkiOpsUa3T3A6Lz2SFC
Scale = 1:81.7
1
2
3
4
5
6
7
8
9
10
11
12
13
17 16 15 14
18
19 20
21 22
6x8
6x8
6x8
5x8
10x12
4x6
3x6
3x6
3x6
10x12
4x6
3x6
3x6
3x6
2x4
5x8
THJA26
Special
HGUS28-2
Special
8-0-0
6-5-0
3-5-12
3-5-12
6-10-4
3-4-8
11-0-0
Job
REAGAN_MODEL
Truss
G11
Truss Type
Attic Girder
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273038
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:37 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-hvcTcVvZuETo1AA91z0w2JT9lkiOpsUa3T3A6Lz2SFC
NOTES-
15) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1476 lb down and 113 lb up at 6-10-0, and 718 lb down and 447 lb up
at 15-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
16) Attic room checked for L/360 deflection.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-5=-60, 5-6=-70, 6-7=-60, 7-8=-60, 8-9=-70, 9-13=-60, 2-12=-20, 6-8=-10
Drag: 5-16=-10, 9-15=-10
Concentrated Loads (lb)
Vert: 16=-1476(F) 15=-1476(F) 21=-718(F) 22=-718(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G12
Truss Type
ATTIC GIRDER
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273039
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:39 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-eIjE1BwpQrjWHTKX8O3O8kZMpYFZHkQtXnYHBEz2SFA
Scale = 1:76.3
1 2
3
4
5
6
7
8
9
13 12 11 10
14 16 15
17
18
19
3x6
4x4
10x12
6x8
6x8
12x20
2x4
3x6
10x12
4x4
3x6
2x4 6x8
5x8
3x6
4x6
LU24 LU24
13-6-0
6-5-0
3-6-7
4-1-4
4-1-4
11-0-0
6-10-12
17-10-12
6-10-12
19-10-8
1-11-12
22-0-0
2-1-8
4-1-4
4-1-4
Job
REAGAN_MODEL
Truss
G12
Truss Type
ATTIC GIRDER
Qty
1
Ply
2
REAGAN S
Job Reference (optional)
I30273039
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:39 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-eIjE1BwpQrjWHTKX8O3O8kZMpYFZHkQtXnYHBEz2SFA
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-90, 3-4=-90, 4-5=-90, 5-6=-105, 6-9=-90, 9-13=-30, 5-14=-15
Drag: 12-14=-15, 6-11=-15
Concentrated Loads (lb)
Vert: 12=-161(B) 11=-163(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G13
Truss Type
Jack-Closed Girder
Qty
2
Ply
2
REAGAN S
Job Reference (optional)
I30273040
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:40 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-6UHcFXxRB9rNuduji5adgx5bCyoC0GG1lRIqjgz2SF9
Scale = 1:41.4
1
2
3
4
6 5
7
2x4
5x6
5x6
3x4
3x6
2-10-14
2-10-14
6-0-0
3-1-2
-1-0-0
1-0-0
2-10-14
2-10-14
6-0-0
3-1-2
0-10-15
6-10-15
12.00 12
Plate Offsets (X,Y)-- [3:0-1-4,0-1-8], [5:0-3-0,0-3-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
Job
REAGAN_MODEL
Truss
G13
Truss Type
Jack-Closed Girder
Qty
2
Ply
2
REAGAN S
Job Reference (optional)
I30273040
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:40 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-6UHcFXxRB9rNuduji5adgx5bCyoC0GG1lRIqjgz2SF9
LOAD CASE(S) Standard
Trapezoidal Loads (plf)
Vert: 2=-358-to-4=-270
2) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-5=-220(F=-200)
Trapezoidal Loads (plf)
Vert: 2=-358-to-4=-270
3) Dead + 0.75 Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-50, 2-5=-195(F=-175)
Trapezoidal Loads (plf)
Vert: 2=-323-to-4=-235
4) Dead + 0.75 Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-50, 2-5=-195(F=-175)
Trapezoidal Loads (plf)
Vert: 2=-323-to-4=-235
5) Dead + 0.75 Snow (Unbal. Left): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-50, 2-5=-195(F=-175)
Trapezoidal Loads (plf)
Vert: 2=-323-to-7=-256, 7=-269-to-4=-248
6) Dead + 0.75 Snow (Unbal. Right): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-29, 2-5=-143(F=-123)
Trapezoidal Loads (plf)
Vert: 2=-249-to-4=-161
7) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-4, 2-5=-61(F=-49)
Horz: 1-2=-8, 2-4=2
Trapezoidal Loads (plf)
Vert: 2=-161-to-4=-73
8) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=1, 2-5=-29(F=-17)
Horz: 1-2=-13, 2-4=-17
Trapezoidal Loads (plf)
Vert: 2=-110-to-4=-22
9) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-27, 2-5=-147(F=-127)
Horz: 1-2=7, 2-4=11
Trapezoidal Loads (plf)
Job
REAGAN_MODEL
Truss
G13
Truss Type
Jack-Closed Girder
Qty
2
Ply
2
REAGAN S
Job Reference (optional)
I30273040
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:40 2017 Page 3
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-6UHcFXxRB9rNuduji5adgx5bCyoC0GG1lRIqjgz2SF9
LOAD CASE(S) Standard
15) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=6, 2-5=-131(F=-111)
Horz: 1-2=-26, 2-4=-22
Trapezoidal Loads (plf)
Vert: 2=-207-to-4=-119
16) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-7, 2-5=-131(F=-111)
Horz: 1-2=-13, 2-4=-8
Trapezoidal Loads (plf)
Vert: 2=-220-to-4=-132
17) Dead + Snow on Overhangs: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-100, 2-5=-120(F=-100)
Trapezoidal Loads (plf)
Vert: 2=-218-to-4=-130
18) Dead + Snow (Unbal. Left): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-5=-220(F=-200)
Trapezoidal Loads (plf)
Vert: 2=-358-to-7=-291, 7=-308-to-4=-287
19) Dead + Snow (Unbal. Right): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-32, 2-5=-150(F=-130)
Trapezoidal Loads (plf)
Vert: 2=-260-to-4=-172
20) Dead: Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90
Uniform Loads (plf)
Vert: 1-2=-20, 2-5=-120(F=-100)
Trapezoidal Loads (plf)
Vert: 2=-218-to-4=-130
21) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-55, 2-5=-215(F=-195)
Horz: 1-2=5, 2-4=8
Trapezoidal Loads (plf)
Vert: 2=-351-to-4=-264
22) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-40, 2-5=-203(F=-183)
Horz: 1-2=-10, 2-4=-6
Trapezoidal Loads (plf)
Vert: 2=-325-to-4=-237
Job
REAGAN_MODEL
Truss
G13
Truss Type
Jack-Closed Girder
Qty
2
Ply
2
REAGAN S
Job Reference (optional)
I30273040
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:40 2017 Page 4
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-6UHcFXxRB9rNuduji5adgx5bCyoC0GG1lRIqjgz2SF9
LOAD CASE(S) Standard
Uniform Loads (plf)
Vert: 1-2=-40, 2-5=-203(F=-183)
Horz: 1-2=-10, 2-4=-6
Trapezoidal Loads (plf)
Vert: 2=-325-to-4=-237
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G14
Truss Type
Diagonal Hip Girder
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273041
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:40 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-6UHcFXxRB9rNuduji5adgx5d1ymN0E91lRIqjgz2SF9
Scale = 1:43.4
1
2
3
4
7 6
5
8
9 10
6x8
2x4
4x4 4x4
3x4
TJC37 TJC37
TJC37 TJC37
4-2-3
4-2-3
8-4-5
4-2-3
-1-5-0
1-5-0
4-2-3
4-2-3
8-4-5
4-2-3
0-10-15
6-9-14
8.49 12
Plate Offsets (X,Y)-- [3:0-1-12,0-1-8], [7:Edge,0-5-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
Job
REAGAN_MODEL
Truss
G14
Truss Type
Diagonal Hip Girder
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273041
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:40 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-6UHcFXxRB9rNuduji5adgx5d1ymN0E91lRIqjgz2SF9
LOAD CASE(S) Standard
Uniform Loads (plf)
Vert: 1-2=-60, 2-4=-60, 5-7=-20
Concentrated Loads (lb)
Vert: 9=-48(F=-24, B=-24) 10=-224(F=-112, B=-112)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
G15
Truss Type
Flat Girder
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273042
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:41 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-agr_Ssy3yTzEWnTwGp5sD9eqAL7dlkxA_51NF6z2SF8
Scale = 1:32.6
1 2
4
6 3
5
2x4
3x4 2x4
4x4
LU24
3-7-0
3-7-0
3-7-0
3-7-0
4-10-5
5-10-5
1-0-0
4-10-5
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.19
0.18
Job
REAGAN_MODEL
Truss
G16
Truss Type
Roof Special Girder
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273043
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:42 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-2sPMfCzijm548x26pWc5lMB?OlUkUAyJDlnxoZz2SF7
Scale: 3/16"=1’
1
2
4 3
6 5
7
8
3x6
2x4
4x8
3x4
3x4
3x4
4x4
3x4
LU24 3-7-0
3-7-0
3-7-0
3-7-0
11-10-9
1-0-0
8-10-12
10.00 12
Plate Offsets (X,Y)-- [1:0-3-0,0-1-0], [2:0-1-8,0-1-8], [5:0-2-12,0-2-0], [6:0-2-0,0-1-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
Job
REAGAN_MODEL
Truss
G17
Truss Type
Half Hip Girder
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273044
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:43 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-W3zktYzKT4Dxl5dINE7KIaj1j9ppDdsTRPWUK?z2SF6
Scale = 1:15.1
1
2
3 4
6 7 8 5
4x8 2x4
4x6 4x4
2x4
TJC37
Special LU24
1-4-1
1-4-1
6-0-8
4-8-7
-1-0-0
1-0-0
1-4-1
1-4-1
6-0-8
4-8-7
0-9-7
2-1-7
12.00 12
Plate Offsets (X,Y)-- [2:Edge,0-1-1], [3:0-6-8,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
Job
REAGAN_MODEL
Truss
G17
Truss Type
Half Hip Girder
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273044
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:37:43 2017 Page 2
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-W3zktYzKT4Dxl5dINE7KIaj1j9ppDdsTRPWUK?z2SF6
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-4=-60, 2-5=-20
Concentrated Loads (lb)
Vert: 6=-14(B) 7=-38(B) 8=-38(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
REAGAN_MODEL
Truss
H1
Truss Type
Hip
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273045
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:01 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-_W2YfiBcEcUOws?mR0SY1NT2hPm4Rdw6aCtRyyz2SEq
Scale = 1:81.6
1
34
5 6 7 8 9 10
11 12
13
21
20 19 18 17
16
15
14
22
23
24 25 26 27 28
29 30 31 32
33 34
3x6
5x6 3x6
6x8
3x6
5x8
4x8
3x4
2x4
5x10
3x10
2x4
3x4
3x4
3x4
3x4
6x8
5x12 MT20HS
3x10
4x8
9-7-1
9-7-1
18-1-14
8-6-13
26-8-11
8-6-13
35-3-8
8-6-13
43-5-0
8-1-8
Job
REAGAN_MODEL
Truss
H2
Truss Type
Hip
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273046
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:04 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-P5kgHkEVXXsznJkL68?Fe?5ZLdnDe_UZHA65YHz2SEn
Scale = 1:80.4
1
2
3
4
5 6 7 8 9
10
11
19 18 17 16 15
14
13
12
20
21
22 23 24 25 26
27 28 29 30 31 32
3x6
6x8 3x6
5x6
5x6
5x8
3x6 3x4
2x4
6x18
5x12 MT20HS
3x4
2x4
4x4
3x4
3x4
4x8 5x8
8-10-7
8-10-7
17-8-2
8-9-11
26-5-13
8-9-11
35-3-8
8-9-11
43-5-0
8-1-8
-1-0-0
1-0-0
6-0-5
6-0-5
Job
REAGAN_MODEL
Truss
H3
Truss Type
Hip
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273047
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:05 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-tII3U4E7Ir_qOTJXgrXUBDeju16fNSyiVqrf5jz2SEm
Scale = 1:91.5
1
2
3
4
5 6 7 8 9
10
11
12
20 19 18 17 16 15
14
13
21
22
23
24 25 26 27
28
29
30
31 32 33 34 35 36
37 38
3x6
6x8 3x6
6x8
3x4
5x6
3x6
2x4
2x4
4x4
2x4
3x4
3x4
2x4
5x12 MT20HS
6x8
4x4
5x12 MT20HS
4x6
8-10-7
8-10-7
17-8-2
8-9-11
26-5-13
8-9-11
Job
REAGAN_MODEL
Truss
H4
Truss Type
Half Hip
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273048
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:06 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-LUsRiQFl386h0dujDZ2jkQA4wQd961LrkUbCdAz2SEl
Scale: 1/2"=1’
1
2
3
4 5
6
7
2x4
3x4
3x6
3x4
4x4
6-0-0
6-0-0
-1-0-0
1-0-0
3-0-1
3-0-1
6-0-0
2-11-15
0-9-7
3-9-7
12.00 12
Plate Offsets (X,Y)-- [4:0-2-8,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
Job
REAGAN_MODEL
Truss
H5
Truss Type
Half Hip
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273049
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:07 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-pgQpvlGNqSEXenTwnGZyGej89qzRrTd?z8Kl9cz2SEk
Scale = 1:34.0
1
2
3
4 5
6
4x4 2x4
3x4
3x6
3x4
3x4
6-0-0
6-0-0
-1-0-0
1-0-0
4-8-1
4-8-1
6-0-0
1-3-15
0-9-7
5-5-7
12.00 12
Plate Offsets (X,Y)-- [4:0-2-8,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
Job
REAGAN_MODEL
Truss
H6
Truss Type
Half Hip
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273050
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:07 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-pgQpvlGNqSEXenTwnGZyGejG3q?wrTF?z8Kl9cz2SEk
Scale = 1:35.0
1
2
3
4
5 6
8 7
6x8 2x4
3x4
3x6
3x4
4x4
2x4
4-3-8
4-3-8
6-0-0
1-8-8
-1-0-0
1-0-0
2-8-1
2-8-1
5-0-10
2-4-9
6-0-0
0-11-6
0-9-7
5-10-1
3-10-1
2-0-0
12.00 12
6.00 12
Plate Offsets (X,Y)-- [2:0-2-10,0-0-6], [5:0-6-8,0-2-0], [8:0-2-0,0-2-4]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Job
REAGAN_MODEL
Truss
H7
Truss Type
Half Hip
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273051
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:08 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-HtzB75H?bmNOFw16L_4BprFH_ECOaqx8Bo4Jh2z2SEj
Scale: 3/16"=1’
1
2
3
4
5 6 7
8 9
15 14
13 12
11 10
16
17
18
19 20 21 22 23
24 25 26
3x6
4x6 4x4 4x6
5x12 MT20HS
4x6
3x4
3x10
2x4
2x4
3x10
2x4
4x8
3x4
9-7-1
9-7-1
17-4-2
7-9-1
24-11-7
7-7-5
32-8-8
7-9-1
-1-0-0
1-0-0
4-9-15
4-9-15
9-7-1
4-9-2
17-4-2
7-9-1
24-11-7
7-7-5
Job
REAGAN_MODEL
Truss
H8
Truss Type
Half Hip
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273052
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:10 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-EF5yYnIG7Nd6VEBUSP6fuGLaM2sI2csRf5ZPmxz2SEh
Scale = 1:67.8
1
2
3
4
5 6 7 8 9
15 14 13 12 11 10
16
17 18 19 20
21 22 23 24 25 26 27 28
3x4
6x8 3x4 4x4
4x6
4x6
3x4 3x6
2x4
3x4
3x4
3x4
4x4
4x4
8-1-13
8-1-13
16-2-14
8-1-1
24-3-15
8-1-1
32-8-8
8-4-9
-1-0-0
1-0-0
6-0-5
6-0-5
11-11-14
5-11-9
18-9-9
6-9-11
25-7-5
6-9-11
32-8-8
7-1-3
0-7-7
10-7-5
10.00 12
Plate Offsets (X,Y)-- [5:0-6-4,0-2-0], [9:Edge,0-3-8], [10:Edge,0-2-0], [11:0-1-8,0-1-8]
Job
REAGAN_MODEL
Truss
H9
Truss Type
Half Hip
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273053
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:11 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-iSfKl7Juthlz6Omh06duRUtoHRCZn7dbulIzINz2SEg
Scale = 1:76.3
12
3
4
5 6 7 8 9
15 14 13 12 11 10
16
17
18
19
20 21
22
23 24 25 26 27 28 29
3x6
4x6 3x4 3x4
3x6
4x6
2x4 3x4
3x4
3x10
3x4
4x4
4x4
3x6
8-1-13
8-1-13
16-2-14
8-1-1
24-3-15
8-1-1
32-8-8
8-4-9
-1-0-0
1-0-0
7-2-11
7-2-11
14-4-10
7-1-15
20-4-12
6-0-2
26-4-14
6-0-2
32-8-8
6-3-10
0-7-7
Job
REAGAN_MODEL
Truss
H10
Truss Type
Half Hip
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273054
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:02 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-Tjcws2CF?wcFX?ay_jznZa0OppG9ADLGpsd_UPz2SEp
Scale: 1/2"=1’
1
2
3
4 5
6
7
2x4
3x4
3x6
3x4
4x4
6-0-8
6-0-8
-1-0-0
1-0-0
3-0-1
3-0-1
6-0-8
3-0-7
0-9-7
3-9-7
12.00 12
Plate Offsets (X,Y)-- [4:0-2-8,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
Job
REAGAN_MODEL
Truss
H11
Truss Type
Half Hip
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273055
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:02 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-Tjcws2CF?wcFX?ay_jznZa0IQpGCACPGpsd_UPz2SEp
Scale = 1:34.0
1
2
3
4 5
6
4x4 2x4
3x4
3x6
3x4
3x4
6-0-8
6-0-8
-1-0-0
1-0-0
4-8-1
4-8-1
6-0-8
1-4-7
0-9-7
5-5-7
12.00 12
Plate Offsets (X,Y)-- [4:0-2-8,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
Job
REAGAN_MODEL
Truss
J1
Truss Type
Jack-Closed
Qty
15
Ply
1
REAGAN S
Job Reference (optional)
I30273056
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:11 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-iSfKl7Juthlz6Omh06duRUts1RLenHGbulIzINz2SEg
Scale = 1:40.8
1
2
3
5 4
6
8x8
2x4
4x4
6-0-0
6-0-0
-1-0-0
1-0-0
6-0-0
6-0-0
0-9-7
6-9-7
12.00 12
Plate Offsets (X,Y)-- [5:Edge,0-6-9]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
Job
REAGAN_MODEL
Truss
J2
Truss Type
Jack-Closed
Qty
10
Ply
1
REAGAN S
Job Reference (optional)
I30273057
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:17 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-Wb0b0AOfTXV7qJDrNNkIgl7t_sO2A?XTGhlHW1z2SEa
Scale = 1:40.6
1
2
4 3
5
8x8
2x4
4x4
6-0-0
6-0-0
6-0-0
6-0-0
0-9-7
6-9-7
12.00 12
Plate Offsets (X,Y)-- [4:Edge,0-6-9]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.58
0.24
0.08
Job
REAGAN_MODEL
Truss
J3
Truss Type
Jack-Closed
Qty
3
Ply
1
REAGAN S
Job Reference (optional)
I30273058
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:20 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-xAikeCQXmSthhmyP2VI?INlUP4SaNMdvyf_x6Mz2SEX
Scale = 1:38.8
1
2
3
4
7
6
5
8x8
2x4
4x4 3x4
3x4
4-3-8
4-3-8
6-0-0
1-8-8
-1-0-0
1-0-0
4-3-8
4-3-8
6-0-0
1-8-8
0-9-7
6-9-7
4-9-7
2-0-0
12.00 12
6.00 12
Plate Offsets (X,Y)-- [3:0-1-4,0-1-8], [6:0-2-0,0-2-4], [7:0-3-0,0-6-4]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
Job
REAGAN_MODEL
Truss
J4
Truss Type
Jack-Closed
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273059
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:20 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-xAikeCQXmSthhmyP2VI?INlPl4QMNLavyf_x6Mz2SEX
Scale = 1:38.0
1
2
4 3
5
8x8
2x4
4x4
5-6-8
5-6-8
5-6-8
5-6-8
0-9-7
6-3-15
12.00 12
Plate Offsets (X,Y)-- [4:Edge,0-6-9]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.48
0.20
0.07
Job
REAGAN_MODEL
Truss
J5
Truss Type
Jack-Closed
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273060
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:21 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-PNG6rYR9Xl?YJwXccDpEqbIf_Tps6pV3BJjVfoz2SEW
Scale = 1:20.2
1
2
3
5 4
6
8x8
2x4
4x4
3-2-11
3-2-11
-1-0-1
1-0-1
3-2-11
3-2-11
0-9-12
3-5-2
9.72 12
Plate Offsets (X,Y)-- [5:Edge,0-6-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
Job
REAGAN_MODEL
Truss
J6
Truss Type
Jack-Closed
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273061
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:22 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-tZqU3uRnI37Px46o9wKTNorqlt8DrGlCPzT2BEz2SEV
Scale = 1:19.2
1
2
3
5 4
6
8x8
2x4
4x4
3-0-1
3-0-1
-1-0-1
1-0-1
3-0-1
3-0-1
0-9-10
3-2-11
9.67 12
Plate Offsets (X,Y)-- [5:Edge,0-6-5]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
Job
REAGAN_MODEL
Truss
J7
Truss Type
Jack-Closed
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273062
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:22 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-tZqU3uRnI37Px46o9wKTNorqht8drGpCPzT2BEz2SEV
Scale = 1:15.8
1
2
3
5 4
8x8
2x4
3x4
2-2-6
2-2-5
-1-0-4
1-0-4
2-2-6
2-2-6
0-9-11
2-6-9
9.51 12
Plate Offsets (X,Y)-- [5:Edge,0-6-5]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.14
Job
REAGAN_MODEL
Truss
J8
Truss Type
Jack-Closed
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273063
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:23 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-LlNsGESQ3NFGYEh_jdriw0N?THUTaj?MedCcjhz2SEU
Scale = 1:19.2
1
2
3
5 4
6
8x8
2x4
4x4
2-11-14
2-11-14
-1-0-2
1-0-2
2-11-14
2-11-14
0-9-12
3-2-11
9.67 12
Plate Offsets (X,Y)-- [5:Edge,0-6-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
Job
REAGAN_MODEL
Truss
J9
Truss Type
Jack-Closed
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273064
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:23 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-LlNsGESQ3NFGYEh_jdriw0N?VHUgaj1MedCcjhz2SEU
Scale = 1:17.6
1
2
3
5 4
8x8
2x4
4x4
2-7-4
2-7-4
-1-0-0
1-0-0
2-7-4
2-7-4
0-9-11
2-10-14
9.69 12
Plate Offsets (X,Y)-- [5:Edge,0-6-5]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.13
Job
REAGAN_MODEL
Truss
J10
Truss Type
Jack-Closed
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273065
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:12 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-AeDiyTKWe_tqkYLtaq97zhQ7GrkrWlHk6P2Wqpz2SEf
Scale = 1:19.7
1
2
3
5 4
6
8x8
2x4
4x4
3-1-0
3-1-0
-1-0-0
1-0-0
3-1-0
3-1-0
0-9-12
3-3-15
9.78 12
Plate Offsets (X,Y)-- [5:Edge,0-6-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
Job
REAGAN_MODEL
Truss
J11
Truss Type
Jack-Closed
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273066
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:13 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-eqn4ApL8PI?hMiw38XgMWvzI0F4nECetL3n4NGz2SEe
Scale = 1:12.2
1
2
3
5
4
8x8
2x4
3x4
1-3-13
1-3-13
-1-0-0
1-0-0
1-3-13
1-3-13
0-9-8
1-10-1
9.52 12
Plate Offsets (X,Y)-- [5:Edge,0-6-5]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
Job
REAGAN_MODEL
Truss
J12
Truss Type
Jack-Closed
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273067
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:13 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-eqn4ApL8PI?hMiw38XgMWvzGVF4bECdtL3n4NGz2SEe
Scale = 1:13.8
1
2
3
5
4
6
8x8
2x4
4x4
2-0-10
2-0-10
-1-6-12
1-6-12
2-0-10
2-0-10
0-9-7
2-1-3
1-6-7
0-6-11
1-7-10
0-5-9
7.68 12
3.84 12
Plate Offsets (X,Y)-- [5:0-3-0,0-1-12]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
Job
REAGAN_MODEL
Truss
J13
Truss Type
Jack-Closed
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273068
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:14 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-60LSN9LmAc7YzrVGhEBb26VS?fQXzfp1ajXdviz2SEd
Scale = 1:16.9
1
2
3
5
4
6
8x8
2x4
4x4
2-8-7
2-8-7
-1-5-0
1-5-0
2-8-7
2-8-7
0-9-7
2-8-6
8.49 12
Plate Offsets (X,Y)-- [5:Edge,0-6-3]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Job
REAGAN_MODEL
Truss
J14
Truss Type
Jack-Closed
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273069
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:14 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-60LSN9LmAc7YzrVGhEBb26VRFfQmzfr1ajXdviz2SEd
Scale = 1:14.3
1
2
3
5 4
6
8x8
2x4
4x4
2-2-9
2-2-2
-1-6-12
1-6-12
2-2-9
2-2-9
0-9-7
2-2-7
7.68 12
Plate Offsets (X,Y)-- [5:0-3-0,0-1-12]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
Job
REAGAN_MODEL
Truss
J15
Truss Type
Jack-Closed
Qty
8
Ply
1
REAGAN S
Job Reference (optional)
I30273070
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:15 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-aDurbVMOxvFPb?4SFyiqbK2fz3mfi6MAoNGAR8z2SEc
Scale = 1:14.9
1
2
3
4
2x4
4x4 2x4
2-0-0
2-0-0
-1-0-0
1-0-0
2-0-0
2-0-0
0-7-7
2-3-7
10.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.10
0.04
0.00
Job
REAGAN_MODEL
Truss
J16
Truss Type
Jack-Closed
Qty
4
Ply
1
REAGAN S
Job Reference (optional)
I30273071
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:15 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-aDurbVMOxvFPb?4SFyiqbK2eS3m6i61AoNGAR8z2SEc
Scale = 1:17.3
1
2
3
5 2x4 4
3x4
2x4
3x4
1-10-15
1-10-15
-1-0-0
1-0-0
1-10-15
1-10-15
0-10-15
2-9-14
12.00 12
Plate Offsets (X,Y)-- [2:0-1-4,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.14
Job
REAGAN_MODEL
Truss
J17
Truss Type
Jack-Closed
Qty
4
Ply
1
REAGAN S
Job Reference (optional)
I30273072
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:16 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-2PSDoqN1iDNGD9fepfD37Xbo4S4ARZ6K110kzbz2SEb
Scale = 1:27.3
1
2
3
5 4
6
2x4
3x4
2x4
4x4
3-10-15
3-10-15
-1-0-0
1-0-0
3-10-15
3-10-15
0-10-15
4-9-14
12.00 12
Plate Offsets (X,Y)-- [2:0-1-4,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Job
REAGAN_MODEL
Truss
J18
Truss Type
Jack-Closed
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273073
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:16 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-2PSDoqN1iDNGD9fepfD37XboYS4?RZBK110kzbz2SEb
Scale = 1:28.3
1
2
4
3
5
2x4
3x4
2x4
4x4
4-1-8
4-1-8
4-1-8
4-1-8
0-10-15
5-0-7
12.00 12
Plate Offsets (X,Y)-- [1:0-1-4,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.24
Job
REAGAN_MODEL
Truss
J19
Truss Type
Jack-Closed
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273074
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:17 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-Wb0b0AOfTXV7qJDrNNkIgl7yWsRTA0aTGhlHW1z2SEa
Scale = 1:14.3
1
2
3
5 4
6
8x8
2x4
4x4
2-2-9
2-2-9
-1-6-12
1-6-12
2-2-9
2-2-9
0-9-7
2-2-7
7.68 12
Plate Offsets (X,Y)-- [5:0-3-0,0-1-12]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
Job
REAGAN_MODEL
Truss
J20
Truss Type
Jack-Closed
Qty
4
Ply
1
REAGAN S
Job Reference (optional)
I30273075
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:18 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-?oazDWOHEqd_STo1w4FXDyg35GkDvS_dVLVr2Tz2SEZ
Scale = 1:41.1
1
2
3
5 4
6
8x8
2x4
4x4
6-0-8
6-0-8
-1-0-0
1-0-0
6-0-8
6-0-8
0-9-7
6-9-15
12.00 12
Plate Offsets (X,Y)-- [5:Edge,0-6-9]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
Job
REAGAN_MODEL
Truss
J21
Truss Type
Jack-Closed
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273076
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:19 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-T_8LQsPv?8lq4dNDUonmlADE?g4VevFmj?EOavz2SEY
Scale = 1:41.4
1
2
3
5 4
6
2x4
3x4
2x4
4x4
6-0-0
6-0-0
-1-0-0
1-0-0
6-0-0
6-0-0
0-10-15
6-10-15
12.00 12
Plate Offsets (X,Y)-- [2:0-1-4,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Job
REAGAN_MODEL
Truss
J22
Truss Type
Flat
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273077
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:19 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-T_8LQsPv?8lq4dNDUonmlADJog5YewLmj?EOavz2SEY
Scale = 1:56.1
1 2
4 3
5
2x4
3x4 2x4
3x4
4-1-8
4-1-8
4-1-8
4-1-8
10-5-8
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.24
0.17
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Job
REAGAN_MODEL
Truss
K1
Truss Type
Common Supported Gable
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273078
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:24 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-pyxEUZT2qgO7AOGBHLMxSDwBjhq1JAAVtHy9G7z2SET
Scale = 1:32.8
1
2
3
4
5
6
7
10 9 8
11
12
4x4
2x4 2x4
2x4 2x4
2x4
2x4
2x4
8-7-0
8-7-0
-1-0-0
1-0-0
4-3-8
4-3-8
8-7-0
4-3-8
9-7-0
1-0-0
0-5-3
4-8-11
0-5-3
12.00 12
Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [6:0-2-6,0-1-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Job
REAGAN_MODEL
Truss
K2
Truss Type
Common
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273079
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:24 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-pyxEUZT2qgO7AOGBHLMxSDw86hpbJA4VtHy9G7z2SET
Scale = 1:32.8
1
2
3
4
5
6
7
8
4x4
2x4 2x4
2x4
4-3-8
4-3-8
8-7-0
4-3-8
-1-0-0
1-0-0
4-3-8
4-3-8
8-7-0
4-3-8
9-7-0
1-0-0
0-5-3
4-8-11
0-5-3
12.00 12
Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [4:0-2-6,0-1-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
Job
REAGAN_MODEL
Truss
M1
Truss Type
Monopitch Supported Gable
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273080
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:25 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-H8VdhvUga_W_oYrNr2tA?RTLy59f2dDe6xhioZz2SES
Scale = 1:38.8
1
2
3
4
5
9 8 7 6
10
3x10
2x4
2x4
2x4
2x4
2x4
2x4
0-0-1
0-0-1
5-6-9
5-6-8
-0-11-15
0-11-15
5-6-9
5-6-9
0-9-6
6-3-15
12.00 12
Plate Offsets (X,Y)-- [9:0-3-8,Edge]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
Job
REAGAN_MODEL
Truss
N1
Truss Type
Roof Special
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273081
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:26 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-mK3?uFVILIerPhPZOmPPXe?UqUVCn3HoKbRGK?z2SER
Scale = 1:40.7
1
2
3
4
5
6
8 7
9 10
11
4x4
4x4
2x4
3x4
3x6
3x4
3x4
3-8-4
3-8-4
7-10-0
4-1-12
-1-0-0
1-0-0
3-8-4
3-8-4
5-6-4
1-10-0
7-10-0
2-3-12
0-9-7
4-5-11
6-9-7
4-5-11
12.00 12
Plate Offsets (X,Y)-- [4:0-2-8,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
Job
REAGAN_MODEL
Truss
P1
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273082
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:27 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-EXdN6bVw6bmi1r_myTwe4sYf6uroWWHxZFApsSz2SEQ
Scale = 1:36.1
1
2
3
4 5 6
7 8
9
10
11
12
17 16 15 14 13
18 19
3x4 3x4
3x4
3x4
2x4
2x4
5x6
2x4
2x4
2x4
2x4
2x4
2x4
2x4
3x4
21-0-3
21-0-3
3-1-9
3-1-9
17-10-10
14-9-1
21-0-3
3-1-9
0-4-13
2-5-13
2-7-5
0-1-8
0-4-13
0-1-8
2-5-13
10.00 12
Plate Offsets (X,Y)-- [2:0-2-1,0-1-8], [4:0-2-0,0-1-13], [9:0-2-0,0-1-13], [11:0-2-1,0-1-8], [16:0-3-0,0-3-0]
LOADING (psf)
TCLL (roof)
Job
REAGAN_MODEL
Truss
P2
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273083
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:29 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-Avl7XHXAeD0QG9884uy69Hd?8iV6_POE0ZfwxKz2SEO
Scale = 1:36.7
1
2
3
4 5 6 7 8
9
10
11
16 15 14 13 12
17
18 19 20 21
22
3x4 3x4
3x4
2x4
2x4
5x6
2x4
2x4
2x4
2x4
2x4
2x4
2x4
3x4
21-0-3
21-0-3
5-6-6
5-6-6
15-5-13
9-11-8
21-0-3
5-6-6
0-4-13
4-5-13
4-7-5
0-1-8
0-4-13
0-1-8
4-5-13
10.00 12
Plate Offsets (X,Y)-- [2:0-2-1,0-1-8], [4:0-2-0,0-1-13], [8:0-2-0,0-1-13], [10:0-2-1,0-1-8], [15:0-3-0,0-3-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
Job
REAGAN_MODEL
Truss
P3
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273084
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:30 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-e5IWkdYpPW8HuJjLdcTLiUABt6rRjrCOFDPTTnz2SEN
Scale = 1:41.4
1
2
3
4
5 6
7
8
9
10
11
16 15 14 13 12
17
18
19
20
3x4 3x4
3x4
2x4
2x4
5x6
2x4
2x4
2x4
2x4
2x4
2x4
2x4
3x4
21-0-3
21-0-3
7-11-2
7-11-2
13-1-1
5-1-14
21-0-3
7-11-2
0-4-13
6-5-13
6-7-5
0-1-8
0-4-13
0-1-8
6-5-13
10.00 12
Job
REAGAN_MODEL
Truss
P4
Truss Type
GABLE
Qty
9
Ply
1
REAGAN S
Job Reference (optional)
I30273085
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:31 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-6IsuyzYRAqG7WTIXBJ_aEiiMXVBiSKNXUt81?Dz2SEM
Scale = 1:56.0
1
2
3
4
5
6
7
9 8
14 13 12 11 10
15
16
17 18
19
20
4x4
3x4
5x6 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
3x4
21-0-3
21-0-3
10-6-1
10-6-1
21-0-3
10-6-1
0-4-13
8-7-9
8-9-1
0-1-8
0-4-13
0-1-8
10.00 12
Plate Offsets (X,Y)-- [2:0-2-1,0-1-8], [8:0-2-1,0-1-8], [13:0-3-0,0-3-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
Job
REAGAN_MODEL
Truss
P5
Truss Type
GABLE
Qty
2
Ply
1
REAGAN S
Job Reference (optional)
I30273086
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:32 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-aUQG9JZ3x8O_8ctjl0WpnvFXDvXwBnbgjXuaYfz2SEL
Scale = 1:52.5
1
2
3
4
5
6
7
8
13 12 11 10 9
15
16
17 18
19
14
4x4
2x4
3x4
2x4
5x6
2x4
2x4
2x4
2x4
2x4
2x4
3x6
19-0-9
19-0-9
10-6-1
10-6-1
19-0-9
8-6-8
0-4-13
8-7-9
8-9-1
0-1-8
1-6-3
0-1-8
10.00 12
Plate Offsets (X,Y)-- [2:0-2-1,0-1-8], [12:0-3-0,0-3-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
Job
REAGAN_MODEL
Truss
P6
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273087
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:33 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-2g_eMeahiRWrlmSvJk12K7ohVJu9wEmqxBd746z2SEK
Scale = 1:33.7
1
2
3 4 5 6 7
8
9
15 14 13 12 11 10
17 18
16
3x4
3x4
2x4
3x4
2x4 3x4
2x4
2x4
2x4
2x4
5x6
2x4
2x4
2x4
19-0-9
19-0-9
3-1-9
3-1-9
17-10-10
14-9-1
19-0-9
1-1-15
0-4-13
2-5-13
2-7-5
0-1-8
1-6-3
0-1-8
2-5-13
10.00 12
Plate Offsets (X,Y)-- [2:0-2-1,0-1-8], [3:0-2-0,0-1-13], [6:0-3-0,0-3-0], [8:0-2-0,0-1-13]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
Job
REAGAN_MODEL
Truss
P7
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273088
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:34 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-XtY0a_bJTleiNw16sRYHsKKs1jDVfghzAqNhcYz2SEJ
Scale = 1:33.8
1
2
3
4 5 6
7
8
9
15 14 13 12 11 10
17
18 19 20 21
22
16
3x4 3x4
2x4
3x4
2x4 3x4
2x4
2x4
2x4
2x4
2x4
2x4 2x4
2x4
19-0-9
19-0-9
5-6-6
5-6-6
15-5-13
9-11-8
19-0-9
3-6-12
0-4-13
4-5-13
4-7-5
0-1-8
1-6-3
0-1-8
4-5-13
10.00 12
Plate Offsets (X,Y)-- [2:0-2-1,0-1-8], [4:0-2-0,0-1-13], [7:0-2-0,0-1-13]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
Job
REAGAN_MODEL
Truss
P8
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273089
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:35 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-?36PnKcxE3mZ?4cIQ93WPYt1h7YkO5t7PU6E8_z2SEI
Scale = 1:43.2
1
2
3
4 5 6
7
8
14 13 12 11 10 9
16
17
18
19 20
21
22
15
3x4
3x4
3x4
2x4 3x4
2x4
2x4
4x4
2x4
2x4
2x4
2x4
2x4
19-0-9
19-0-9
7-11-2
7-11-2
13-1-1
5-1-14
19-0-9
5-11-9
0-4-13
6-5-13
6-7-5
0-1-8
1-6-3
0-1-8
6-5-13
10.00 12
Plate Offsets (X,Y)-- [2:0-2-1,0-1-8], [4:0-2-0,0-1-13], [6:0-2-0,0-1-13]
LOADING (psf)
Job
REAGAN_MODEL
Truss
P9
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273090
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:37 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-xSE9C0dCmg0HEOlhYa5_UzyM6wEDs0JQsobLDtz2SEG
Scale = 1:46.6
1
2
3
4
5 6
7
8
9
15 14 13 12 11 10
17
18
19
20 21
22
23
16
3x4
4x6
2x4
3x4
2x4 3x4
2x4
2x4
2x4
2x4 2x4
2x4
2x4
19-0-9
19-0-9
8-9-10
8-9-10
12-2-9
3-4-15
19-0-9
6-10-1
0-4-13
7-2-8
7-4-0
0-1-8
1-6-3
0-1-8
7-2-8
10.00 12
Plate Offsets (X,Y)-- [2:0-2-1,0-1-8], [5:0-2-0,0-1-13], [7:0-4-4,0-2-0]
Job
REAGAN_MODEL
Truss
V1
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273091
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:38 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-PenXQMeqX_88sXKt5HcE1AVakKcTbTKZ5SLulJz2SEF
Scale = 1:76.4
1
2
3
4
5
6
7
8
9
10
11
12
23 22 21
20
19 18 17 16 15 14 13
24
25
26
3x4
4x4
2x4
3x4 2x4
2x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
3x4
18-4-4
18-4-4
11-4-13
11-4-13
18-4-4
Job
REAGAN_MODEL
Truss
V2
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273092
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:42 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-IP12FjhKaCfaK9eeK7hAB0gEmxxDXHn904J6u4z2SEB
Scale = 1:62.8
1
2
3
4
5
6
12 11 10 9 8 7
13
14
15
16
17
3x4
4x4
2x4
3x4 2x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
0-0-4
0-0-4
16-8-4
16-8-0
9-8-13
9-8-13
16-8-4
6-11-8
0-0-4
9-8-13
2-9-5
12.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
Job
REAGAN_MODEL
Truss
V3
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273093
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:42 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-IP12FjhKaCfaK9eeK7hAB0gElxxDXG8904J6u4z2SEB
Scale = 1:53.0
1
2
3
4
5
10 9 8 7 6
11
12
13 14
15
3x4
4x4
2x4
3x4 2x4
2x4 2x4
2x4
2x4
2x4
0-0-4
0-0-4
15-0-4
15-0-0
8-0-13
8-0-13
15-0-4
6-11-8
0-0-4
8-0-13
1-1-5
12.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Job
REAGAN_MODEL
Truss
V4
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273094
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:43 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-mcbQT3iyLWnRyJDquqCPkECQ9LIvGlsIEk2fRWz2SEA
Scale = 1:42.0
1
2
3
4
5
8 7 6
9 10
3x4 11 12
4x4
3x4
2x4 2x4
2x4
2x4
2x4
0-0-4
0-0-4
12-9-9
12-9-5
6-4-13
6-4-13
12-9-9
6-4-13
0-0-4
6-4-13
0-0-4
12.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
Job
REAGAN_MODEL
Truss
V5
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273095
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:44 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-Eo9ogPjb6qvHaSo1SYjeGRlahle8?DbRTOoDzzz2SE9
Scale: 3/8"=1’
1
2
3
4
5
6
2x4
4x4
2x4
2x4
0-0-4
0-0-4
9-5-9
9-5-5
4-8-13
4-8-13
9-5-9
4-8-13
0-0-4
4-8-13
0-0-4
12.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
Job
REAGAN_MODEL
Truss
V6
Truss Type
Valley
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273096
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:44 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-Eo9ogPjb6qvHaSo1SYjeGRlcUlfQ?DGRTOoDzzz2SE9
Scale = 1:21.5
1
2
3
4
2x4
4x4
2x4
2x4
0-0-4
0-0-4
6-1-9
6-1-5
3-0-13
3-0-13
6-1-9
3-0-13
0-0-4
3-0-13
0-0-4
12.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
Job
REAGAN_MODEL
Truss
V7
Truss Type
Valley
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273097
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:45 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-i_iAuljDt718BcMD0FEtpfIon9?ukgnbi2XmVPz2SE8
Scale = 1:9.8
1
2
3
2x4
3x4
2x4
0-0-4
0-0-4
2-9-9
2-9-5
1-4-13
1-4-13
2-9-9
1-4-13
0-0-4
1-4-13
0-0-4
12.00 12
Plate Offsets (X,Y)-- [2:0-2-0,Edge]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Job
REAGAN_MODEL
Truss
V8
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273098
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:46 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-AAGZ55kreR9?pmxPZzm6LsqvYYJIT6QkxiHJ1rz2SE7
Scale = 1:39.0
1
2
3 4
5
6
7
11 10 9 8
12
13 14
15
3x4 16 17
3x4 3x4
3x4
3x4 2x4
2x4
2x4
2x4
2x4
2x4
0-0-5
0-0-5
15-11-1
15-10-12
7-3-12
7-3-12
8-7-5
1-3-10
15-11-1
7-3-12
0-0-4
6-1-2
0-0-4
6-1-2
10.00 12
Plate Offsets (X,Y)-- [3:0-2-0,0-1-13], [5:0-2-0,0-1-13]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
Job
REAGAN_MODEL
Truss
V9
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273099
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:47 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-eNqxJRlTPlHsRwWc7gHLu4N62yghCaTu9M0taIz2SE6
Scale = 1:28.4
1
2
3
4
5
8 7 6
9
10
3x4
4x4
3x4
2x4 2x4
2x4
2x4
2x4
0-0-5
0-0-5
11-1-8
11-1-3
5-6-12
5-6-12
11-1-8
5-6-12
0-0-4
4-7-10
0-0-4
10.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
Job
REAGAN_MODEL
Truss
V10
Truss Type
Valley
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273100
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:39 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-tqLvdifSHHG?Thv3f_8TZO2lhkyEKy0iK64SHlz2SEE
Scale = 1:18.4
1
2
3
4
2x4
4x4
2x4 2x4
0-0-5
0-0-5
6-3-14
6-3-9
3-1-15
3-1-15
6-3-14
3-1-15
0-0-4
2-7-10
0-0-4
10.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Job
REAGAN_MODEL
Truss
V12
Truss Type
GABLE
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273101
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:39 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-tqLvdifSHHG?Thv3f_8TZO2lckyPKyeiK64SHlz2SEE
Scale = 1:35.8
1
2
3
5 4
6
2x4
4x4
2x4
2x4
2x4
0-0-3
0-0-3
5-2-14
5-2-11
2-3-5
2-3-5
5-2-14
2-11-9
0-0-4
3-5-0
5-10-10
18.00 12
10.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
Job
REAGAN_MODEL
Truss
V13
Truss Type
Roof Special
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273102
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:40 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-L1vIq2f42bPs5rUGDifi6bawM8Ig3PBsYmq?qCz2SED
Scale = 1:22.5
1
2
3
5 4
2x4
4x4
2x4
2x4 2x4
0-0-3
0-0-3
3-10-14
3-10-11
0-11-5
0-11-5
3-10-14
2-11-9
0-0-4
1-5-0
3-10-10
18.00 12
10.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
Job
REAGAN_MODEL
Truss
V14
Truss Type
Roof Special
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273103
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:40 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-L1vIq2f42bPs5rUGDifi6baxM8Iz3PAsYmq?qCz2SED
Scale = 1:23.4
1
2
3
5 4
2x4
4x4
2x4
2x4
2x4
0-0-3
0-0-3
3-5-15
3-5-12
1-8-6
1-8-6
3-5-15
1-9-9
0-0-4
2-6-10
4-0-9
18.00 12
10.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
Job
REAGAN_MODEL
Truss
V15
Truss Type
Roof Special
Qty
1
Ply
1
REAGAN S
Job Reference (optional)
I30273104
Timberland Lumber Company, Indianapolis, IN 46222 8.010 s Apr 20 2016 MiTek Industries, Inc. Mon Jun 26 09:38:41 2017 Page 1
ID:zmOrNt?gPyPDU7VfFE2gz?z3tuW-pDTg2NgipvXjj?3SnPAxep76FXd5osn?nQZYMez2SEC
Scale = 1:13.2
1
2
3
2x4
2x4
2x4
0-4-7
0-4-7
2-1-15
1-9-9
2-0-9
10.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.05
0.02
0.00
DEFL.
Vert(LL)
Vert(TL)
edge of truss.
/ 16 " from outside
1
0 -
PRODUCT CODE APPROVALS
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
W4-6
W3-6
W3-7
W2-7
W1-7
C1-8
C7-8 C6-7 C5-6
C4-5
C3-4
C1-2 C2-3
TOP CHORD
TOP CHORD
8 7 6 5
4
1 2 3
BOTTOM CHORDS
TOP CHORDS
BEARING
LATERAL BRACING LOCATION
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
The first dimension is the plate
width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
4 x 4
PLATE SIZE
This symbol indicates the
required direction of slots in
connector plates.
/ 16 "
1
For 4 x 2 orientation, locate
plates 0-
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
1 "
/ 4
3
PLATE LOCATION AND ORIENTATION
Symbols Numbering System
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.
Failure to Follow Could Cause Property
Damage or Personal Injury
General Safety Notes
* Plate location details available in MiTek 20/20
software or upon request.
Industry Standards:
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
' 2012 MiTekfi All Rights Reserved
MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015
WEBS
edge of truss.
/ 16 " from outside
1
0 -
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
W4-6
W3-6
W3-7
W2-7
W1-7
C1-8
C7-8 C6-7 C5-6
C4-5
C3-4
C1-2 C2-3
TOP CHORD
TOP CHORD
8 7 6 5
4
1 2 3
BOTTOM CHORDS
TOP CHORDS
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
4 x 4
PLATE SIZE
This symbol indicates the
required direction of slots in
connector plates.
/ 16 "
1
For 4 x 2 orientation, locate
plates 0-
1 "
/ 4
3
PLATE LOCATION AND ORIENTATION
Symbols Numbering System General Safety Notes
* Plate location details available in MiTek 20/20
software or upon request.
Industry Standards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
6-4-8 dimensions shown in ft-in-sixteenths
WEBS
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 7 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-1-15 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=74/2-0-0, 3=74/2-0-0
Max Horz 1=48(LC 13)
Max Uplift 3=-26(LC 13)
Max Grav 1=74(LC 1), 3=78(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) n/a
7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
TC
BC
WB
Matrix-S
0.06
0.01
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-5-15 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=63/3-5-12, 4=61/3-5-12, 5=122/3-5-12
Max Horz 1=109(LC 13)
Max Uplift 1=-2(LC 11), 4=-27(LC 13), 5=-90(LC 13)
Max Grav 1=98(LC 13), 4=64(LC 26), 5=148(LC 26)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
BC
WB
Matrix-S
0.12
0.03
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 15 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-10-14 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=30/3-10-11, 4=106/3-10-11, 5=143/3-10-11
Max Horz 1=104(LC 13)
Max Uplift 1=-32(LC 11), 4=-43(LC 13), 5=-79(LC 13)
Max Grav 1=100(LC 13), 4=112(LC 22), 5=166(LC 26)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
CSI.
TC
BC
WB
Matrix-S
0.12
0.04
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 24 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-2-14 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=84/5-2-11, 4=106/5-2-11, 5=196/5-2-11
Max Horz 1=164(LC 13)
Max Uplift 1=-13(LC 11), 4=-44(LC 13), 5=-143(LC 13)
Max Grav 1=157(LC 13), 4=111(LC 22), 5=235(LC 22)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb)
5=143.
7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 4, 5.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Matrix-S
0.12
0.05
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 18 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=125/6-3-4, 3=125/6-3-4, 4=191/6-3-4
Max Horz 1=44(LC 10)
Max Uplift 1=-13(LC 14), 3=-19(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable requires continuous bottom chord bearing.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.16
0.07
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 34 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 11-0-14.
(lb) - Max Horz 1=83(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-115(LC 13), 6=-114(LC 14)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=316(LC 22), 6=316(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-257/161, 4-6=-257/161
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable requires continuous bottom chord bearing.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
8=115, 6=114.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.27
0.15
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
7
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 53 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 3-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 15-10-8.
(lb) - Max Horz 1=-112(LC 9)
Max Uplift All uplift 100 lb or less at joint(s) 1 except 11=-119(LC 13), 8=-118(LC 14)
Max Grav All reactions 250 lb or less at joint(s) except 1=268(LC 35), 7=268(LC 35), 9=364(LC 49), 11=564(LC
35), 8=564(LC 35)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-280/100, 5-6=-280/100
WEBS 2-11=-465/163, 6-8=-465/163
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Provide adequate drainage to prevent water ponding.
6) Gable requires continuous bottom chord bearing.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) n/a
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Matrix-S
0.01
0.03
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 7 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-9-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=84/2-9-1, 3=84/2-9-1
Max Horz 1=20(LC 10)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable requires continuous bottom chord bearing.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
WB
Matrix-S
0.11
0.05
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 19 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=130/6-1-1, 3=130/6-1-1, 4=175/6-1-1
Max Horz 1=-53(LC 9)
Max Uplift 1=-18(LC 14), 3=-18(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable requires continuous bottom chord bearing.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
TC
BC
WB
Matrix-S
0.23
0.13
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 30 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=194/9-5-1, 3=194/9-5-1, 4=312/9-5-1
Max Horz 1=-85(LC 9)
Max Uplift 1=-18(LC 14), 3=-18(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable requires continuous bottom chord bearing.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.15
0.13
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 45 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 12-9-1.
(lb) - Max Horz 1=117(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-145(LC 13), 6=-144(LC 14)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=328(LC 22), 8=338(LC 22), 6=338(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-257/186, 4-6=-257/186
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable requires continuous bottom chord bearing.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.19
0.16
0.25
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
6
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 58 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 15-0-0.
(lb) - Max Horz 1=147(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 1 except 10=-172(LC 13), 7=-171(LC 14)
Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=458(LC 25), 10=449(LC 22), 7=408(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-10=-301/216, 4-7=-274/203
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 5-0-13, Exterior(2) 5-0-13 to 8-0-13,
Interior(1) 11-0-13 to 11-10-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable requires continuous bottom chord bearing.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.19
0.16
0.14
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
7
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 72 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-9
REACTIONS. All bearings 16-8-0.
(lb) - Max Horz 1=176(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 7 except 1=-154(LC 11), 11=-165(LC 13), 12=-116(LC 13),
8=-159(LC 14)
Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 9=520(LC 25), 11=435(LC 22), 12=268(LC 22),
8=405(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-202/252
WEBS 4-9=-304/79, 3-11=-294/214, 5-8=-269/199
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 6-8-13, Exterior(2) 6-8-13 to 9-8-13,
Interior(1) 12-8-13 to 13-6-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable requires continuous bottom chord bearing.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb)
1=154, 11=165, 12=116, 8=159.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
6-11-8
0-0-4
11-4-13
4-5-5
12.00 12
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.07
0.02
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
13
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 118 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 8-17, 7-18, 9-16
REACTIONS. All bearings 18-4-4.
(lb) - Max Horz 1=217(LC 13)
Max Uplift All uplift 100 lb or less at joint(s) 13, 17, 18, 19, 21, 22, 23, 16, 15, 14 except 1=-159(LC 11)
Max Grav All reactions 250 lb or less at joint(s) 13, 18, 19, 21, 22, 23, 16, 15, 14, 1 except 17=340(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-297/254, 7-8=-204/262
WEBS 8-17=-316/178
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-4-4 to 3-4-13, Interior(1) 3-4-13 to 8-4-13, Exterior(2) 8-4-13 to 11-4-13,
Interior(1) 14-4-13 to 15-2-8 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable requires continuous bottom chord bearing.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 17, 18, 19, 21,
22, 23, 16, 15, 14 except (jt=lb) 1=159.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.32
0.15
0.22
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.00
-0.00
(loc)
1
1
16
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 71 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-7.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 18-1-8.
(lb) - Max Horz 2=135(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 2, 13 except 15=-131(LC 13), 11=-139(LC 14)
Max Grav All reactions 250 lb or less at joint(s) 2, 10 except 15=569(LC 36), 13=504(LC 44), 12=443(LC 49),
11=570(LC 46)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-15=-475/174, 4-13=-324/84, 6-12=-265/16, 8-11=-456/170
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12, Interior(1) 3-2-12 to 4-6-11, Exterior(2) 4-6-11 to 16-5-8,
Interior(1) 16-5-8 to 18-10-13 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 4-0-0 oc.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
11) n/a
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.31
0.15
0.28
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.00
0.00
(loc)
1
1
9
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 70 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-6.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 18-1-8.
(lb) - Max Horz 2=121(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 2, 12, 11, 10, 9 except 14=-125(LC 13)
Max Grav All reactions 250 lb or less at joint(s) 9 except 2=264(LC 36), 14=577(LC 36), 12=446(LC 49),
11=550(LC 49), 10=499(LC 46)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-14=-483/167, 4-12=-273/82, 5-11=-419/56, 7-10=-404/126
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12, Interior(1) 3-2-12 to 3-8-4, Exterior(2) 3-8-4 to 17-3-15,
Interior(1) 17-3-15 to 18-10-13 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 4-0-0 oc.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9.
12) n/a
13) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.30
0.15
0.15
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.00
-0.00
(loc)
1
1
16
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 63 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-7.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 18-1-8.
(lb) - Max Horz 2=84(LC 13)
Max Uplift All uplift 100 lb or less at joint(s) 2, 15, 13, 12, 10, 11
Max Grav All reactions 250 lb or less at joint(s) 10 except 2=258(LC 36), 15=473(LC 44), 13=539(LC 41),
12=589(LC 41), 11=353(LC 46)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-15=-373/108, 5-13=-427/72, 6-12=-477/79, 8-11=-256/54
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-2-12 to 9-9-4, Interior(1) 9-9-4 to 11-2-15, Exterior(2) 11-2-15 to 15-5-13
zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 4-0-0 oc.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 15, 13, 12, 10,
11.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.29
0.09
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.00
0.00
(loc)
1
1
10
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 55 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-8.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 18-1-8.
(lb) - Max Horz 2=58(LC 13)
Max Uplift All uplift 100 lb or less at joint(s) 2, 15, 13, 12, 11, 10
Max Grav All reactions 250 lb or less at joint(s) 10 except 2=261(LC 36), 15=414(LC 35), 13=544(LC 35),
12=538(LC 35), 11=496(LC 35)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 4-15=-335/72, 5-13=-464/81, 6-12=-457/75, 7-11=-420/71
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-2-12 to 7-4-7, Interior(1) 7-4-7 to 13-7-12, Exterior(2) 13-7-12 to 17-10-10
zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 4-0-0 oc.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10.
12) n/a
13) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.20
0.15
0.13
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
0.00
(loc)
1
1
14
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 74 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-11
REACTIONS. All bearings 18-1-8.
(lb) - Max Horz 2=161(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 2, 11, 13, 9 except 12=-120(LC 13), 10=-137(LC 14)
Max Grav All reactions 250 lb or less at joint(s) 2, 9 except 11=420(LC 26), 12=416(LC 23), 13=269(LC 23),
10=444(LC 24)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-269/190, 4-5=-274/263, 5-6=-275/243
WEBS 5-11=-265/160, 4-12=-277/170, 6-10=-293/185, 7-9=-273/120
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12, Interior(1) 3-2-12 to 7-6-1, Exterior(2) 7-6-1 to 10-6-1,
Interior(1) 13-6-1 to 18-10-13 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 4-0-0 oc.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11, 13, 9
except (jt=lb) 12=120, 10=137.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.19
0.15
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
0.00
(loc)
8
8
8
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 77 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-12
REACTIONS. All bearings 19-9-1.
(lb) - Max Horz 2=-166(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 2, 14, 10, 8 except 13=-121(LC 13), 11=-124(LC 14)
Max Grav All reactions 250 lb or less at joint(s) 2, 8 except 12=384(LC 30), 13=415(LC 23), 14=270(LC 23),
11=425(LC 28), 10=265(LC 24)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 4-13=-283/170, 6-11=-289/174
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12, Interior(1) 3-2-12 to 7-6-1, Exterior(2) 7-6-1 to 10-6-1,
Interior(1) 13-6-1 to 17-9-7 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 4-0-0 oc.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
10) n/a
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Plate Offsets (X,Y)-- [2:0-2-1,0-1-8], [5:0-2-0,0-1-13], [7:0-2-0,0-1-13], [10:0-2-1,0-1-8], [15:0-3-0,0-3-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.25
0.15
0.25
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.00
0.01
(loc)
10
10
10
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 73 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 5-7.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 19-9-1.
(lb) - Max Horz 2=-125(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 2, 14, 15, 13, 10 except 16=-104(LC 13), 12=-107(LC 14)
Max Grav All reactions 250 lb or less at joint(s) 2, 10 except 14=501(LC 41), 15=494(LC 44), 16=465(LC 36),
13=501(LC 46), 12=462(LC 36)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 6-14=-366/57, 4-15=-389/123, 3-16=-400/148, 8-13=-397/121, 9-12=-400/149
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12, Interior(1) 3-2-12 to 3-8-4, Exterior(2) 3-8-4 to 17-3-15,
Interior(1) 17-3-15 to 17-9-7 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 4-0-0 oc.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14, 15, 13, 10
except (jt=lb) 16=104, 12=107.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.31
0.16
0.16
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
0.01
(loc)
10
10
10
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 67 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 4-8.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. All bearings 19-9-1.
(lb) - Max Horz 2=-86(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 2, 14, 15, 16, 13, 12
Max Grav All reactions 250 lb or less at joint(s) 2, 10 except 14=595(LC 41), 15=444(LC 35), 16=413(LC 36),
13=453(LC 35), 12=411(LC 36)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-330/63, 8-9=-326/57
WEBS 6-14=-485/82, 5-15=-362/77, 3-16=-344/126, 7-13=-370/70, 9-12=-345/124
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-2-12 to 9-9-4, Interior(1) 9-9-4 to 11-2-15, Exterior(2) 11-2-15 to 15-5-13
zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 4-0-0 oc.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14, 15, 16, 13,
12.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.28
0.09
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
11
11
11
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 58 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 4-9.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 19-9-1.
(lb) - Max Horz 2=-48(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 2, 15, 16, 17, 14, 13, 11
Max Grav All reactions 250 lb or less at joint(s) 2, 11 except 15=528(LC 35), 16=541(LC 35), 17=271(LC 36),
14=544(LC 35), 13=275(LC 36)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 6-15=-451/73, 5-16=-459/74, 8-14=-460/74
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-2-12 to 7-4-7, Interior(1) 7-4-7 to 13-7-12, Exterior(2) 13-7-12 to 17-10-10
zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 4-0-0 oc.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 15, 16, 17, 14,
13, 11.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.32
0.11
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.01
0.00
(loc)
8
7-8
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 47 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
SLIDER Left 2x4 SPF No.2 2-7-15
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 7=304/Mechanical, 2=371/0-3-8
Max Horz 2=205(LC 13)
Max Uplift 7=-100(LC 13)
Max Grav 7=430(LC 36), 2=595(LC 36)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-468/0
WEBS 5-7=-307/94
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
7=100.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.13
0.07
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
0.00
(loc)
1
1
6
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 30 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-6-9 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 5-6-8.
(lb) - Max Horz 9=188(LC 13)
Max Uplift All uplift 100 lb or less at joint(s) 9, 6, 7 except 8=-151(LC 13)
Max Grav All reactions 250 lb or less at joint(s) 9, 6, 7, 8
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) -0-11-15 to 2-0-1, Exterior(2) 2-0-1 to 2-4-13, Corner(3) 2-4-13 to 5-4-13
zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
7) Gable studs spaced at 2-0-0 oc.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6, 7 except
(jt=lb) 8=151.
10) Non Standard bearing condition. Review required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.27
0.12
0.03
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.02
0.00
(loc)
6
4-6
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 32 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 2=400/0-3-8, 4=400/0-3-8
Max Horz 2=-102(LC 11)
Max Uplift 2=-15(LC 13), 4=-15(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-326/23, 3-4=-326/23
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2 and 4. This
connection is for uplift only and does not consider lateral forces.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.10
0.03
0.03
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
7
7
6
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 37 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 8-7-0.
(lb) - Max Horz 2=-102(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 2, 10, 8
Max Grav All reactions 250 lb or less at joint(s) 2, 6, 9, 10, 8
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 2-0-0 oc.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10, 8.
11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2, 6.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
in
-0.02
-0.04
0.00
(loc)
3-4
3-4
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 44 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 1-4, 2-3, 1-3
REACTIONS. (lb/size) 4=153/0-3-8, 3=153/Mechanical
Max Uplift 4=-12(LC 9), 3=-12(LC 9)
Max Grav 4=182(LC 3), 3=154(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Provide adequate drainage to prevent water ponding.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
7) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 4. This
connection is for uplift only and does not consider lateral forces.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Matrix-S
0.55
0.24
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.10
-0.00
(loc)
5
4-5
4
l/defl
****
>717
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 32 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=304/0-3-8, 4=221/Mechanical
Max Horz 5=202(LC 13)
Max Uplift 4=-125(LC 13)
Max Grav 5=307(LC 20), 4=246(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
4=125.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.56
0.25
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.10
-0.00
(loc)
5
4-5
4
l/defl
****
>702
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 32 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=306/0-3-8, 4=223/Mechanical
Max Horz 5=204(LC 13)
Max Uplift 4=-121(LC 13)
Max Grav 5=308(LC 20), 4=247(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-5=-251/0
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
4=121.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.29
0.02
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
4-5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 12 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-9 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=225/0-4-9, 4=32/Mechanical
Max Horz 5=66(LC 13)
Max Uplift 5=-17(LC 13), 4=-37(LC 19)
Max Grav 5=285(LC 19), 4=40(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-5=-266/85
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 5. This
connection is for uplift only and does not consider lateral forces.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.10
0.03
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.02
-0.00
(loc)
4
3-4
3
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 21 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-1-8 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 4=153/0-3-8, 3=153/Mechanical
Max Horz 4=116(LC 13)
Max Uplift 3=-91(LC 13)
Max Grav 4=153(LC 19), 3=171(LC 22)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Matrix-S
0.21
0.09
0.03
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.02
-0.00
(loc)
5
4-5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 22 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-10-15 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=224/0-3-8, 4=134/Mechanical
Max Horz 5=139(LC 13)
Max Uplift 4=-86(LC 13)
Max Grav 5=225(LC 20), 4=152(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.02
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 12 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-10-15 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=158/0-3-8, 4=40/Mechanical
Max Horz 5=79(LC 13)
Max Uplift 4=-48(LC 13)
Max Grav 5=188(LC 19), 4=54(LC 27)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
0.00
(loc)
2
2
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 9 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 4=56/Mechanical, 2=152/0-3-8
Max Horz 2=70(LC 13)
Max Uplift 4=-27(LC 13)
Max Grav 4=62(LC 23), 2=168(LC 19)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.29
0.02
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
4-5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 12 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-9 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=225/0-4-9, 4=31/Mechanical
Max Horz 5=66(LC 13)
Max Uplift 5=-17(LC 13), 4=-37(LC 19)
Max Grav 5=285(LC 19), 4=40(LC 27)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-5=-266/85
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 5. This
connection is for uplift only and does not consider lateral forces.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Matrix-S
0.25
0.04
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
4-5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 14 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-7 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=220/0-4-9, 4=66/Mechanical
Max Horz 5=80(LC 13)
Max Uplift 5=-6(LC 13), 4=-31(LC 13)
Max Grav 5=255(LC 19), 4=75(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 5 and 4. This
connection is for uplift only and does not consider lateral forces.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.29
0.02
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
5
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 11 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-0-10 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=222/0-3-11, 4=21/Mechanical
Max Horz 5=62(LC 13)
Max Uplift 5=-17(LC 13), 4=-48(LC 19)
Max Grav 5=289(LC 19), 4=31(LC 11)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-5=-272/113
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 5. This
connection is for uplift only and does not consider lateral forces.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.13
0.01
0.01
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 8 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-3-13 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=148/0-3-8, 4=3/Mechanical
Max Horz 5=48(LC 13)
Max Uplift 5=-2(LC 13), 4=-43(LC 19)
Max Grav 5=199(LC 19), 4=18(LC 11)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 5. This
connection is for uplift only and does not consider lateral forces.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.13
0.05
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.01
-0.00
(loc)
5
4-5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 16 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-1-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=194/0-3-8, 4=97/Mechanical
Max Horz 5=93(LC 13)
Max Uplift 4=-49(LC 13)
Max Grav 5=195(LC 20), 4=108(LC 27)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.03
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
4-5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 14 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-7-4 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=178/0-3-7, 4=75/Mechanical
Max Horz 5=80(LC 13)
Max Uplift 4=-42(LC 13)
Max Grav 5=189(LC 19), 4=85(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.13
0.05
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
4-5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 16 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-11-14 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=192/0-3-7, 4=93/Mechanical
Max Horz 5=90(LC 13)
Max Uplift 4=-47(LC 13)
Max Grav 5=194(LC 19), 4=103(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.02
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
4-5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 12 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-6 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=167/0-3-7, 4=55/Mechanical
Max Horz 5=70(LC 13)
Max Uplift 4=-35(LC 13)
Max Grav 5=190(LC 19), 4=64(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.13
0.05
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
4-5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 16 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-0-1 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=192/0-3-9, 4=94/Mechanical
Max Horz 5=90(LC 13)
Max Uplift 4=-47(LC 13)
Max Grav 5=193(LC 19), 4=104(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.13
0.06
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.01
-0.00
(loc)
5
4-5
4
l/defl
****
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 17 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-2-11 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=200/0-3-7, 4=104/Mechanical
Max Horz 5=96(LC 13)
Max Uplift 4=-51(LC 13)
Max Grav 5=200(LC 20), 4=114(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.07
-0.00
(loc)
4
3-4
3
l/defl
****
>922
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 28 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-6-8 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 4=210/0-3-8, 3=210/Mechanical
Max Horz 4=159(LC 13)
Max Uplift 3=-113(LC 13)
Max Grav 4=211(LC 19), 3=231(LC 22)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
3=113.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.19
0.12
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.03
0.00
(loc)
6
6-7
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 36 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 7=304/0-3-8, 5=221/Mechanical
Max Horz 7=202(LC 13)
Max Uplift 5=-122(LC 13)
Max Grav 7=307(LC 20), 5=245(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-7=-266/101, 2-3=-255/0
BOT CHORD 6-7=-281/152
WEBS 3-5=-340/180
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
5=122.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.10
-0.00
(loc)
4
3-4
3
l/defl
****
>717
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 30 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 4=228/0-3-8, 3=228/Mechanical
Max Horz 4=173(LC 13)
Max Uplift 3=-122(LC 13)
Max Grav 4=230(LC 19), 3=251(LC 22)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
3=122.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.55
0.24
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.10
-0.00
(loc)
5
4-5
4
l/defl
****
>717
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 32 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=304/0-3-8, 4=221/Mechanical
Max Horz 5=202(LC 13)
Max Uplift 4=-120(LC 13)
Max Grav 5=307(LC 20), 4=245(LC 23)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
4=120.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
TC
BC
WB
Matrix-S
0.67
0.26
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.11
0.00
(loc)
2
2-6
6
l/defl
****
>651
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 33 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
SLIDER Left 2x4 SPF No.2 3-4-5
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins: 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 6=231/Mechanical, 2=301/0-3-8
Max Horz 2=170(LC 13)
Max Uplift 6=-70(LC 13)
Max Grav 6=303(LC 33), 2=526(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-301/72
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
CSI.
TC
BC
WB
Matrix-S
0.26
0.27
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.11
0.00
(loc)
2
2-6
6
l/defl
****
>651
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 28 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
SLIDER Left 2x4 SPF No.2 2-2-3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 6=231/Mechanical, 2=301/0-3-8
Max Horz 2=120(LC 13)
Max Uplift 6=-26(LC 10)
Max Grav 6=339(LC 32), 2=475(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-290/23
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
12-7-5
10.00 12
Plate Offsets (X,Y)-- [3:0-1-12,0-1-8], [10:0-2-12,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.79
0.82
0.75
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.20
-0.40
0.07
(loc)
10-11
10-11
10
l/defl
>999
>973
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 198 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SP 2400F 2.0E *Except*
5-7,7-9: 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
8-10: 2x4 SP 2400F 2.0E
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-5-9 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-3-12 max.): 5-9.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 9-10, 3-13, 6-13, 6-11, 8-10
REACTIONS. (lb/size) 10=1295/0-3-8, 2=1367/0-3-8
Max Horz 2=386(LC 13)
Max Uplift 10=-101(LC 10)
Max Grav 10=1907(LC 32), 2=1598(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2036/3, 3-5=-1394/86, 5-6=-1082/110, 6-8=-924/59, 9-10=-291/46
BOT CHORD 2-15=-242/1513, 13-15=-227/1563, 11-13=-98/1108, 10-11=-57/777
WEBS 3-15=0/373, 3-13=-877/177, 5-13=0/505, 6-13=-117/425, 6-11=-642/129, 8-11=-15/933,
8-10=-1724/128
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 10-1-12, Exterior(2) 10-1-12 to 14-4-10,
Interior(1) 18-7-9 to 29-6-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 10. This
connection is for uplift only and does not consider lateral forces.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.99
0.82
0.98
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.19
-0.40
0.08
(loc)
10-11
10-11
10
l/defl
>999
>978
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 177 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
5-7: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (2-2-0 max.): 5-9.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 9-10, 5-13, 6-13, 6-11
2 Rows at 1/3 pts 8-10
REACTIONS. (lb/size) 10=1295/0-3-8, 2=1367/0-3-8
Max Horz 2=326(LC 13)
Max Uplift 10=-101(LC 10)
Max Grav 10=1952(LC 32), 2=1604(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2056/40, 3-5=-1903/138, 5-6=-1408/103, 6-8=-1152/58, 9-10=-339/53
BOT CHORD 2-15=-218/1469, 13-15=-136/1236, 11-13=-106/1437, 10-11=-61/1051
WEBS 3-15=-536/219, 5-15=-110/823, 5-13=-76/494, 6-13=-246/347, 6-11=-623/101,
8-11=0/883, 8-10=-1856/109
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-8-15, Exterior(2) 7-8-15 to 11-11-14,
Interior(1) 16-2-12 to 29-6-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 10. This
connection is for uplift only and does not consider lateral forces.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
32-8-8
7-9-1
0-7-7
8-7-5
10.00 12
Plate Offsets (X,Y)-- [5:0-3-4,0-2-4], [7:0-2-0,Edge], [9:0-2-12,0-1-12], [10:0-3-8,Edge], [11:0-1-8,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.79
0.72
0.49
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.42
0.08
(loc)
13-15
2-15
10
l/defl
>999
>919
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 172 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
5-7,7-9: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
9-10: 2x4 SP 2400F 2.0E
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-8-11 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-3-12 max.): 5-9.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 9-10, 6-15, 6-11, 8-11
REACTIONS. (lb/size) 10=1295/0-3-8, 2=1367/0-3-8
Max Horz 2=265(LC 13)
Max Uplift 10=-102(LC 10)
Max Grav 10=1935(LC 32), 2=1590(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1948/84, 3-5=-1857/103, 5-6=-1412/120, 6-8=-1381/75, 8-9=-1381/75,
9-10=-1866/139
BOT CHORD 2-15=-215/1411, 13-15=-108/1836, 11-13=-108/1836
WEBS 3-15=-402/164, 5-15=0/704, 6-15=-661/114, 6-13=0/395, 6-11=-696/68, 8-11=-819/149,
9-11=-109/2006
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-4-2, Exterior(2) 5-4-2 to 9-7-1,
Interior(1) 13-9-15 to 29-6-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 10. This
connection is for uplift only and does not consider lateral forces.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.16
0.16
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.03
0.01
(loc)
8
2-8
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 34 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
SLIDER Left 2x4 SPF No.2 1-11-6
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins: 5-6.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 7=222/Mechanical, 2=303/0-3-8
Max Horz 2=183(LC 13)
Max Uplift 7=-89(LC 13)
Max Grav 7=319(LC 33), 2=539(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-562/38, 4-5=-293/25
BOT CHORD 2-8=-176/312
WEBS 5-8=-98/274, 5-7=-298/120
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Refer to girder(s) for truss to truss connections.
9) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
TC
BC
WB
Matrix-S
0.67
0.26
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.11
0.00
(loc)
2
2-6
6
l/defl
****
>665
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 33 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
SLIDER Left 2x4 SPF No.2 3-4-5
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins: 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 6=229/Mechanical, 2=299/0-3-8
Max Horz 2=170(LC 13)
Max Uplift 6=-71(LC 13)
Max Grav 6=303(LC 33), 2=524(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-299/74
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
CSI.
TC
BC
WB
Matrix-S
0.25
0.26
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.11
0.00
(loc)
2
2-6
6
l/defl
****
>665
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 28 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
SLIDER Left 2x4 SPF No.2 2-2-3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins: 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 6=229/Mechanical, 2=299/0-3-8
Max Horz 2=120(LC 13)
Max Uplift 6=-26(LC 10)
Max Grav 6=336(LC 32), 2=474(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-288/21
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
35-3-8
8-9-11
43-5-0
8-1-8
-1-0-0
1-0-0
7-2-11
7-2-11
14-4-10
7-1-15
20-10-14
6-6-4
27-5-2
6-6-4
33-11-6
6-6-4
35-3-8
1-4-2
39-2-8
3-11-0
43-5-0
4-2-8
0-7-7
12-7-5
2-8-9
2-0-0
12-7-5
10.00 12
Plate Offsets (X,Y)-- [5:0-6-4,0-2-0], [9:0-6-0,0-1-12], [14:0-2-12,0-2-12], [18:0-1-8,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.97
0.98
0.57
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.28
-0.50
0.12
(loc)
16-18
16-18
13
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 266 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
4-5,1-4: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2 *Except*
17-19: 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (2-2-0 max.): 5-9.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. Except:
1 Row at midpt 10-14
WEBS 1 Row at midpt 6-18, 6-16, 8-16, 11-13
REACTIONS. (lb/size) 2=1795/0-3-8, 13=1724/Mechanical
Max Horz 2=252(LC 13)
Max Grav 2=2037(LC 42), 13=2007(LC 35)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2701/125, 3-5=-2631/267, 5-6=-1907/210, 6-8=-1972/211, 8-9=-2012/217,
9-10=-1992/257, 10-11=-2104/188
BOT CHORD 2-20=-131/1992, 18-20=-84/1697, 16-18=-81/2060, 10-14=-316/116, 13-14=-46/1291
WEBS 3-20=-636/278, 5-20=-178/1015, 5-18=-82/820, 6-18=-619/218, 6-16=-298/82,
8-16=-775/127, 9-16=-102/892, 14-16=-2/1588, 9-14=-118/650, 11-14=-41/521,
11-13=-2206/96
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 10-1-12, Exterior(2) 10-1-12 to 14-4-10,
Interior(1) 18-7-9 to 29-8-7, Exterior(2) 33-11-6 to 43-3-4 zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
9) Refer to girder(s) for truss to truss connections.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
11-11-14
5-11-9
19-9-1
7-9-3
27-6-5
7-9-3
35-3-8
7-9-3
36-4-2
1-0-10
43-5-0
7-0-14
0-7-7
10-7-5
2-8-9
2-0-0
10-7-5
10.00 12
Plate Offsets (X,Y)-- [2:0-3-8,Edge], [5:0-6-4,0-2-0], [10:0-3-4,0-2-4], [11:Edge,0-1-4], [12:0-3-8,Edge], [13:0-10-0,0-2-12], [15:0-1-4,0-2-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.96
0.93
0.59
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.27
-0.48
0.12
(loc)
15-17
15-17
12
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 245 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SP 2400F 2.0E *Except*
4-5,1-4: 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
16-18: 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals, and
2-0-0 oc purlins (2-2-0 max.): 5-10.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 2-19.
1 Row at midpt 9-13
WEBS 1 Row at midpt 6-17, 6-15, 8-15, 8-13
REACTIONS. (lb/size) 2=1795/0-3-8, 12=1724/Mechanical
Max Horz 2=226(LC 13)
Max Grav 2=1971(LC 36), 12=2085(LC 35)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2633/131, 3-5=-2531/210, 5-6=-2295/193, 6-8=-2330/191, 8-9=-1884/181,
9-10=-1877/178, 10-11=-2245/152, 11-12=-2000/136
BOT CHORD 2-19=-138/1925, 17-19=-107/1830, 15-17=-124/2434, 9-13=-761/161
WEBS 3-19=-501/212, 5-19=-81/777, 5-17=-97/964, 6-17=-686/192, 6-15=-275/65,
13-15=-101/2388, 8-13=-708/81, 10-13=-135/1483, 11-13=-51/1684
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-8-15, Exterior(2) 7-8-15 to 11-11-14,
Interior(1) 16-2-12 to 32-1-4, Exterior(2) 36-4-2 to 43-3-4 zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
9) Refer to girder(s) for truss to truss connections.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
-1-0-0
1-0-0
4-9-15
4-9-15
9-7-1
4-9-2
16-0-3
6-5-2
22-5-4
6-5-2
28-10-6
6-5-2
35-3-8
6-5-2
38-8-15
3-5-7
43-5-0
4-8-1
0-7-7
8-7-5
2-8-9
2-0-0
8-7-5
10.00 12
Plate Offsets (X,Y)-- [2:0-3-8,Edge], [5:0-3-0,0-2-1], [12:0-6-0,0-1-12], [15:0-4-0,0-2-0], [17:0-0-11,0-2-12]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.99
0.96
0.70
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.30
-0.58
0.16
(loc)
17-19
17-19
14
l/defl
>999
>895
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 224 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
18-20: 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-2-15 oc purlins,
except end verticals, and 2-0-0 oc purlins (2-2-0 max.): 5-12.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 1 Row at midpt 6-21, 7-19, 7-17, 9-17, 9-15, 12-14
REACTIONS. (lb/size) 2=1795/0-3-8, 14=1724/Mechanical
Max Horz 2=200(LC 13)
Max Uplift 2=-3(LC 10), 14=-34(LC 9)
Max Grav 2=1986(LC 35), 14=2162(LC 35)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2696/143, 3-5=-2609/162, 5-6=-1993/165, 6-7=-2848/177, 7-9=-2769/164,
9-11=-2475/161, 11-12=-2476/157, 12-13=-272/89, 13-14=-327/87
BOT CHORD 2-21=-157/1962, 19-21=-163/2778, 17-19=-170/2904, 11-15=-617/102, 14-15=-51/1457
WEBS 3-21=-381/166, 5-21=0/1233, 6-21=-1305/157, 6-19=0/438, 7-17=-307/83,
15-17=-155/2864, 9-15=-497/65, 12-15=-104/2051, 12-14=-2405/121
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-4-2, Exterior(2) 5-4-2 to 9-7-1,
Interior(1) 13-9-15 to 34-6-1, Exterior(2) 38-8-15 to 43-3-4 zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14.
11) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This
connection is for uplift only and does not consider lateral forces.
12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
CSI.
TC
BC
WB
Matrix-S
0.76
0.13
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.01
0.00
(loc)
5-6
5-6
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 29 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins: 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=265/Mechanical, 2=354/0-3-8
Max Horz 2=69(LC 48)
Max Uplift 5=-65(LC 8), 2=-65(LC 11)
Max Grav 5=426(LC 30), 2=440(LC 31)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-441/86, 4-5=-270/42
WEBS 3-5=-265/69
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This
connection is for uplift only and does not consider lateral forces.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Use Simpson Strong-Tie TJC37 (4 nail 90-150) or equivalent at 1-6-0 from the left end to connect truss(es) to back face of bottom
chord, skewed 39.8 deg.to the right, sloping 0.0 deg. down.
12) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss, Single Ply Girder) or equivalent at 4-0-12 from the left end to
connect truss(es) to back face of bottom chord.
13) Fill all nail holes where hanger is in contact with lumber.
14) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 45 lb down and 44 lb up at
2-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
15) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
Continued LOAD CASE(on page S) Standard 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
CSI.
TC
BC
WB
Matrix-S
0.16
0.12
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.01
-0.00
(loc)
4
3-4
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 58 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-7-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-3
REACTIONS. (lb/size) 3=191/Mechanical, 7=182/0-3-8
Max Horz 7=-76(LC 12)
Max Uplift 3=-7(LC 10), 7=-230(LC 12)
Max Grav 3=242(LC 45), 7=214(LC 43)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 7. This
connection is for uplift only and does not consider lateral forces.
10) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss, Single Ply Girder) or equivalent at 1-7-12 from the left end to
connect truss(es) to front face of bottom chord.
11) Fill all nail holes where hanger is in contact with lumber.
12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 3-4=-20
Concentrated Loads (lb)
Vert: 8=-133(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.01
0.00
(loc)
3-4
3-4
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 27 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 4=193/Mechanical, 5=205/0-3-8
Max Uplift 4=-57(LC 7), 5=-66(LC 7)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 5. This
connection is for uplift only and does not consider lateral forces.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss, Single Ply Girder) or equivalent at 1-11-4 from the left end to
connect truss(es) to front face of bottom chord.
12) Fill all nail holes where hanger is in contact with lumber.
13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 3-4=-20
Concentrated Loads (lb)
Vert: 6=-135(F)
VERTICAL LEGS ARE NOT DESIGNED FOR LATERAL
LOADS IMPOSED BY SUPPORTS (BEARINGS).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.28
0.24
0.23
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.02
-0.00
(loc)
5-6
5-6
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 50 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 7=530/0-4-9, 5=481/Mechanical
Max Horz 7=201(LC 11)
Max Uplift 7=-118(LC 11), 5=-275(LC 11)
Max Grav 7=537(LC 18), 5=525(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-7=-509/124, 2-3=-498/128
BOT CHORD 5-6=-225/369
WEBS 2-6=-78/375, 3-6=-197/291, 3-5=-486/297
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
5=275.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 7. This
connection is for uplift only and does not consider lateral forces.
9) Use Simpson Strong-Tie TJC37 (4 nail, 30-90) or equivalent spaced at 2-9-15 oc max. starting at 2-9-8 from the left end to 5-7-7 to
connect truss(es) to front face of bottom chord.
10) Use Simpson Strong-Tie TJC37 (4 nail 90-150) or equivalent spaced at 2-9-15 oc max. starting at 2-9-8 from the left end to 5-7-7 to
connect truss(es) to back face of bottom chord.
11) Fill all nail holes where hanger is in contact with lumber.
12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
23) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-31, 2-5=-203(F=-183)
Horz: 1-2=-19, 2-4=-16
Trapezoidal Loads (plf)
Vert: 2=-315-to-4=-227
24) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-40, 2-5=-203(F=-183)
Horz: 1-2=-10, 2-4=-6
Trapezoidal Loads (plf)
Vert: 2=-325-to-4=-237
25) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-55, 2-5=-215(F=-195)
Horz: 1-2=5, 2-4=8
Trapezoidal Loads (plf)
Vert: 2=-351-to-4=-264
26) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-40, 2-5=-203(F=-183)
Horz: 1-2=-10, 2-4=-6
Trapezoidal Loads (plf)
Vert: 2=-325-to-4=-237
27) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-31, 2-5=-203(F=-183)
Horz: 1-2=-19, 2-4=-16
Trapezoidal Loads (plf)
Vert: 2=-315-to-4=-227
28) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60
Continued on page 4
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Vert: 2=-256-to-4=-168
10) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=-7, 2-5=-131(F=-111)
Horz: 1-2=-13, 2-4=-8
Trapezoidal Loads (plf)
Vert: 2=-220-to-4=-132
11) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=14, 2-5=4(F=16)
Horz: 1-2=-26, 2-4=-30
Trapezoidal Loads (plf)
Vert: 2=-64-to-4=24
12) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=1, 2-5=-29(F=-17)
Horz: 1-2=-13, 2-4=-17
Trapezoidal Loads (plf)
Vert: 2=-110-to-4=-22
13) Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=14, 2-5=4(F=16)
Horz: 1-2=-26, 2-4=-30
Trapezoidal Loads (plf)
Vert: 2=-64-to-4=24
14) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th Parallel: Lumber Increase=1.60, Plate Increase=1.60
Uniform Loads (plf)
Vert: 1-2=1, 2-5=-29(F=-17)
Horz: 1-2=-13, 2-4=-17
Trapezoidal Loads (plf)
Vert: 2=-110-to-4=-22
Continued on page 3
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.40
0.13
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
6
6
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 99 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x10 SP No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=1475/Mechanical, 2=1641/0-3-8
Max Horz 2=204(LC 11)
Max Uplift 5=-93(LC 11)
Max Grav 5=1496(LC 18), 2=1644(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1306/0, 3-4=-390/176, 4-5=-334/53
BOT CHORD 2-6=-36/711, 5-6=-36/711
WEBS 3-6=-20/507, 3-5=-1054/53
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5.
10) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28 has/have been
modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-5=-220(F=-200)
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
7-9-5
3-8-1
11-0-0
3-2-11
14-5-6
3-5-6
14-8-11
0-3-5
17-10-12
3-2-1
19-10-8
1-11-12
22-0-0
2-1-8
8-8-4
11-10-15
0-10-15
8-8-4
12.00 12
Plate Offsets (X,Y)-- [1:0-1-12,0-1-8], [3:0-6-0,0-3-0], [11:0-3-0,0-7-8], [12:0-3-0,0-8-8], [15:0-3-8,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
3-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.69
0.92
0.39
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Attic
in
-0.21
-0.35
0.01
-0.16
(loc)
11-12
11-12
9
11-12
l/defl
>999
>754
n/a
1055
L/d
480
240
n/a
360
PLATES
MT20
Weight: 442 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x8 SP No.2 *Except*
1-3: 2x4 SPF No.2
BOT CHORD 2x10 SP No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals
(Switched from sheeted: Spacing > 2-8-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 1-13
JOINTS 1 Brace at Jt(s): 1, 3, 4, 14, 15, 16
REACTIONS. (lb/size) 13=1664/0-3-8, 9=1639/0-3-8
Max Horz 13=-428(LC 12)
Max Grav 13=2449(LC 73), 9=2100(LC 64)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-13=-3057/46, 1-2=-1359/23, 2-3=-1272/0, 3-4=-863/169, 4-5=-769/90, 5-6=-1546/10,
6-8=-2558/0, 8-9=-2506/0
BOT CHORD 12-13=-219/429, 11-12=0/1419, 10-11=0/1688, 9-10=0/1691
WEBS 1-12=-55/3168, 12-14=-1181/184, 2-14=-803/147, 6-11=0/1620, 14-16=-168/1111,
15-16=-173/1109, 5-15=-1026/0, 4-15=0/577, 3-15=-1541/105, 3-14=-1283/189,
8-10=-821/506, 8-11=-680/421
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
5) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
6) Unbalanced snow loads have been considered for this design.
7) Provide adequate drainage to prevent water ponding.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Ceiling dead load (5.0 psf) on member(s). 5-6, 14-16, 15-16, 5-15; Wall dead load (5.0psf) on member(s).12-14, 6-11
10) Bottom chord live load (40.0 psf) and additional bottom chord dead load (0.0 psf) applied only to room. 11-12
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
12) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss, Single Ply Girder) or equivalent spaced at 13-7-8 oc max. starting
at 4-2-4 from the left end to 17-9-12 to connect truss(es) to back face of bottom chord.
13) Fill all nail holes where hanger is in contact with lumber.
14) Attic room checked for L/360 deflection.
LOAD CASE(S) Standard
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
4-1-12
15-1-12
4-1-12
18-6-4
3-4-8
22-0-0
3-5-12
-1-0-0
1-0-0
3-5-12
3-5-12
6-10-4
3-4-8
7-0-0
0-1-12
11-0-0
4-0-0
15-0-0
4-0-0
15-1-12
0-1-12
18-6-4
3-4-8
22-0-0
3-5-12
23-0-0
1-0-0
0-10-15
11-10-15
0-10-15
12.00 12
Plate Offsets (X,Y)-- [5:0-0-12,Edge], [9:0-0-12,Edge], [11:0-0-0,0-0-0], [12:0-0-0,0-0-0], [15:0-3-8,0-7-8], [16:0-3-8,0-7-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.09
0.32
0.29
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Attic
in
-0.03
-0.08
0.02
-0.01
(loc)
15-16
15-16
12
15-16
l/defl
>999
>999
n/a
7958
L/d
480
240
n/a
360
PLATES
MT20
Weight: 476 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x8 SP No.2
BOT CHORD 2x10 SP No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): 18
REACTIONS. (lb/size) 2=3244/0-3-8, 12=3240/0-3-8
Max Horz 2=-232(LC 36)
Max Uplift 2=-452(LC 11), 12=-450(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4099/621, 3-5=-3926/633, 5-6=-2140/364, 6-7=-340/60, 7-8=-340/60,
8-9=-2140/363, 9-11=-3928/633, 11-12=-4093/615
BOT CHORD 2-17=-485/2819, 16-17=-488/2820, 15-16=-350/2814, 14-15=-364/2734, 12-14=-363/2733
WEBS 3-17=-261/182, 5-16=-449/2391, 9-15=-449/2393, 11-14=-260/179, 6-18=-2596/497,
8-18=-2596/497
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-6-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
5) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
6) Unbalanced snow loads have been considered for this design.
7) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Ceiling dead load (5.0 psf) on member(s). 5-6, 8-9, 6-18, 8-18; Wall dead load (5.0psf) on member(s).5-16, 9-15
10) Bottom chord live load (40.0 psf) and additional bottom chord dead load (0.0 psf) applied only to room. 15-16
11) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2 and 12. This
connection is for uplift only and does not consider lateral forces.
12) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Left Hand Hip) or equivalent at 6-0-6 from the left end to connect truss(es) to
front face of bottom chord.
13) Use Simpson Strong-Tie HGUS28-2 (36-10d Girder, 12-10d Truss) or equivalent at 15-2-0 from the left end to connect truss(es) to
front face of bottom chord.
Continued 14) Fill all on nail page holes 2 where hanger is in contact with lumber.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
7-5-6
3-7-2
10-6-0
3-0-10
13-6-10
3-0-10
17-1-11
3-7-2
21-0-0
3-10-5
22-0-0
1-0-0
0-7-7
6-9-15
0-7-7
6-9-15
10.00 12
Plate Offsets (X,Y)-- [1:0-0-0,0-0-3], [2:0-1-8,0-1-8], [3:0-6-4,0-2-0], [5:0-6-4,0-2-0], [6:0-1-8,0-1-8], [7:0-0-0,0-0-3], [10:0-1-12,0-1-8], [13:0-1-12,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.28
0.55
0.19
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.05
-0.10
0.04
(loc)
13-14
13-14
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 245 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-7-5 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 3-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=3324/0-3-8, 7=2992/0-3-8
Max Horz 1=-133(LC 53)
Max Uplift 1=-177(LC 11), 7=-303(LC 12)
Max Grav 1=3626(LC 34), 7=3359(LC 34)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4637/291, 2-3=-3484/341, 3-4=-2776/326, 4-5=-2776/326, 5-6=-3407/358,
6-7=-4310/381
BOT CHORD 1-14=-239/3346, 13-14=-239/3346, 11-13=-234/2591, 10-11=-207/2530, 9-10=-215/3076,
7-9=-215/3076
WEBS 2-14=0/1181, 2-13=-1068/82, 3-13=-100/1527, 3-11=-188/551, 4-11=-337/92,
5-11=-151/689, 5-10=-142/1346, 6-10=-780/150, 6-9=-51/807
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
5) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
6) Unbalanced snow loads have been considered for this design.
7) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
8) Provide adequate drainage to prevent water ponding.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 1 and 7. This
connection is for uplift only and does not consider lateral forces.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
12) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss) or equivalent spaced at 16-10-8 oc max. starting at 2-0-12 from
the left end to 18-11-4 to connect truss(es) to back face of bottom chord.
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
5-2-5
17-5-2
5-0-9
22-5-10
5-0-9
27-6-3
5-0-9
32-8-8
5-2-5
-1-0-0
1-0-0
3-8-11
3-8-11
7-2-4
3-5-9
12-4-9
5-2-5
17-5-2
5-0-9
22-5-10
5-0-9
27-6-3
5-0-9
32-8-8
5-2-5
0-7-7
6-7-5
10.00 12
Plate Offsets (X,Y)-- [2:0-0-0,0-0-3], [3:0-1-8,0-1-8], [4:0-6-4,0-2-0], [11:Edge,0-4-0], [16:0-4-4,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.42
0.55
0.98
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.12
-0.23
0.07
(loc)
15-16
15-16
11
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 384 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-7-15 oc purlins,
except end verticals, and 2-0-0 oc purlins (5-5-8 max.): 4-10.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 11=3178/0-3-8, 2=3366/0-3-8
Max Horz 2=205(LC 48)
Max Uplift 11=-1187(LC 8), 2=-849(LC 8)
Max Grav 11=3806(LC 30), 2=3573(LC 30)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4833/1221, 3-4=-4322/1233, 4-5=-4592/1382, 5-6=-4591/1382, 6-8=-4134/1297,
8-9=-4134/1297
BOT CHORD 2-19=-966/3530, 18-19=-966/3530, 16-18=-966/3323, 15-16=-1487/4789,
13-15=-1487/4789, 12-13=-814/2628, 11-12=-814/2628
WEBS 3-19=-27/633, 3-18=-610/89, 4-18=-278/1080, 4-16=-686/1977, 5-16=-623/113,
6-16=-357/200, 6-15=-272/661, 6-13=-1041/302, 8-13=-404/90, 9-13=-768/2393,
9-12=-302/720, 9-11=-4143/1284
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Two RT16-2 USP connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 11. This connection is for uplift
only and does not consider lateral forces.
10) Two H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This
connection is for uplift only and does not consider lateral forces.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
1-0-0
1-2-13
1-2-13
2-10-13
1-8-0
5-11-8
3-0-11
10-3-0
4-3-8
14-6-8
4-3-8
18-10-0
4-3-8
19-10-0
1-0-0
0-9-7
2-0-3
9-4-7
0-9-7
2-0-0
1-1-15
12.00 12
6.00 12
Plate Offsets (X,Y)-- [2:Edge,0-0-2], [3:0-2-4,0-1-12], [5:0-2-12,0-2-8], [7:0-1-4,0-1-8], [9:0-2-10,0-0-2], [14:0-10-0,0-2-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.59
0.82
0.47
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.10
-0.21
0.18
(loc)
13
12-13
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 95 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
2-15: 2x6 SPF No.2
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
SLIDER Right 2x4 SPF No.2 3-2-1
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-5-11 oc purlins,
except
2-0-0 oc purlins (4-2-6 max.): 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 9=817/0-3-8, 2=808/0-3-8
Max Horz 2=186(LC 60)
Max Uplift 9=-10(LC 12), 2=-21(LC 11)
Max Grav 9=817(LC 1), 2=1122(LC 36)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1599/77, 3-4=-1935/97, 4-5=-2556/98, 5-6=-1049/64, 6-7=-873/96, 7-9=-1428/0
BOT CHORD 2-15=-139/1010, 14-15=-164/2787, 13-14=-68/1723, 12-13=-56/1485, 11-12=0/871,
9-11=0/1007
WEBS 3-15=-49/1556, 4-15=-1167/15, 4-14=-1501/122, 5-13=0/838, 5-12=-1068/157,
6-12=-47/893, 7-12=-433/107, 7-11=0/502, 5-14=-66/465
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) The Fabrication Tolerance at joint 14 = 6%
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Bearing at joint(s) 9, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
11) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 9 and 2. This
connection is for uplift only and does not consider lateral forces.
12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 59 lb down and 21 lb up at
Continued 1-2-13 on on page top chord. 2 The design/selection of such connection device(s) is the responsibility of others.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.49
0.85
0.70
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.04
0.01
(loc)
5
5
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 40 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x8 SP No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-0-4 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=2224/0-3-8, 4=2182/Mechanical
Max Horz 1=172(LC 11)
Max Uplift 4=-141(LC 11)
Max Grav 1=2225(LC 17), 4=2191(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2046/7
BOT CHORD 1-5=-85/1311, 4-5=-85/1311
WEBS 2-5=-15/2866, 2-4=-2009/130
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
4=141.
7) Use Simpson Strong-Tie HUS28 (22-10d Girder, 8-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at
1-8-15 from the left end to 3-8-15 to connect truss(es) to front face of bottom chord.
8) Fill all nail holes where hanger is in contact with lumber.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 1-4=-20
Concentrated Loads (lb)
Vert: 7=-1993(F) 8=-1993(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
2-0-3
10-6-14
2-0-3
13-0-2
2-5-4
14-10-15
1-10-13
16-9-11
1-10-11
16-11-0
0-1-6
17-1-5
0-2-4
2-2-7
2-2-7
4-1-6
1-10-15
6-6-9
2-5-3
8-6-12
2-0-3
10-6-14
2-0-3
13-0-2
2-5-4
14-10-15
1-10-13
17-1-5
2-2-5
0-9-8
2-7-1
3-2-15
3-5-3
0-9-8
5.23 12
3.24 12 1.10 12
5.25 12
Plate Offsets (X,Y)-- [1:0-2-9,0-2-8], [3:0-5-0,0-2-12], [4:0-5-4,0-2-8], [6:0-5-4,0-2-8], [7:0-5-0,0-2-12], [9:0-1-5,0-5-0], [11:0-3-8,0-4-8], [12:0-3-8,0-3-12], [13:0-4-0,0-5-8],
[15:0-2-12,0-6-4], [16:0-3-8,0-5-12]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.69
0.72
0.23
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.09
-0.21
0.06
(loc)
13
13
9
l/defl
>999
>944
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 228 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SP 2400F 2.0E
BOT CHORD 2x8 SP 2250F 1.8E
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2, Right: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=6931/0-2-12 (req. 0-5-7), 9=6527/0-2-11 (req. 0-5-2)
Max Horz 1=-37(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-11104/0, 2-3=-11371/0, 3-4=-10684/0, 4-5=-10367/39, 5-6=-10367/38,
6-7=-10558/4, 7-8=-10933/0, 8-9=-10498/0
BOT CHORD 1-17=0/9397, 16-17=0/9397, 14-16=0/10536, 13-14=0/10388, 12-13=0/10255,
11-12=0/10102, 10-11=0/8878, 9-10=0/8878
WEBS 2-17=0/631, 2-16=-300/1216, 3-16=0/1810, 3-14=-410/0, 4-14=0/1853, 5-13=0/1790,
6-12=0/1637, 7-12=-357/149, 7-11=0/1427, 8-11=-260/1348, 8-10=0/420
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-6-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
5) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
6) Unbalanced snow loads have been considered for this design.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) WARNING: Required bearing size at joint(s) 1, 9 greater than input bearing size.
9) Use Simpson Strong-Tie HUS26 (14-10d Girder, 6-10d Truss, Single Ply Girder) or equivalent spaced at 4-0-0 oc max. starting at
1-6-11 from the left end to 9-6-11 to connect truss(es) to front face of bottom chord.
10) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 8-0-0 oc max. starting at
3-6-11 from the left end to 15-6-11 to connect truss(es) to front face of bottom chord.
11) Use Simpson Strong-Tie TJC37 (4 nail 90-150) or equivalent at 2-5-10 from the left end to connect truss(es) to back face of bottom
Continued chord, on skewed page 2 33.3 deg.to the right, sloping 0.0 deg. down.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
7-11-15
29-5-9
5-2-9
34-8-1
5-2-9
37-5-4
2-9-3
43-5-0
5-11-12
-1-0-0
1-0-0
6-11-9
6-11-9
13-7-15
6-8-6
18-11-7
5-3-9
24-3-0
5-3-9
29-5-9
5-2-9
34-8-1
5-2-9
37-5-4
2-9-3
43-5-0
5-11-12
0-7-7
12-0-0
1-8-9
3-0-0
12-0-0
10.00 12
Plate Offsets (X,Y)-- [2:Edge,0-3-4], [5:0-6-4,0-2-0], [6:0-3-0,0-1-12], [10:Edge,0-2-11], [11:0-0-12,0-1-8], [12:0-5-0,0-2-0], [13:0-3-12,0-2-10], [14:0-3-8,0-6-0], [20:0-2-6,0-2-4]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.86
0.88
0.95
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.28
-0.51
0.21
(loc)
20-22
19-20
13
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 295 lb FT = 10%
GRIP
169/123
127/93
LUMBER-
TOP CHORD 2x4 SP 2400F 2.0E *Except*
5-8: 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
2-21: 2x4 SPF-S 1650F 1.6E, 16-18: 2x6 SPF No.2
13-16: 2x8 SP No.2
WEBS 2x4 SPF No.2 *Except*
5-20,6-20: 2x4 SPF-S 1650F 1.6E, 12-13: 2x6 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-9-9 oc purlins,
except end verticals, and 2-0-0 oc purlins (2-5-12 max.): 5-10.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. Except:
1 Row at midpt 7-18
WEBS 1 Row at midpt 6-20, 9-18, 9-15, 11-15
REACTIONS. (lb/size) 2=2108/(0-3-8 + H10A Simpson Strong-Tie) (req. 0-3-10), 13=3974/0-3-8 (req. 0-6-12)
Max Horz 2=245(LC 11)
Max Uplift 2=-30(LC 11), 13=-307(LC 12)
Max Grav 2=2312(LC 34), 13=4286(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3127/44, 3-5=-3030/222, 5-6=-2391/123, 6-7=-3766/193, 7-9=-3771/193,
9-10=-3135/187, 10-11=-4046/232, 11-12=-4769/294, 12-13=-3920/213
BOT CHORD 2-22=-162/2245, 20-22=-133/2096, 7-18=-492/91, 17-18=-191/3650, 15-17=-191/3652,
14-15=-196/3610, 13-14=-89/424
WEBS 3-22=-606/277, 5-22=-190/1006, 5-20=-123/1238, 6-20=-2225/198, 18-20=-186/3025,
6-18=-98/1796, 9-18=-221/528, 9-17=0/255, 9-15=-1330/283, 10-15=-121/2248,
11-15=-1654/366, 11-14=-433/1616, 12-14=-172/3359
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) The Fabrication Tolerance at joint 10 = 2%
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
10) WARNING: Required bearing size at joint(s) 13 greater than input bearing size.
11) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
Continued capacity on of page bearing 2 surface.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
CSI.
TC
BC
WB
Matrix-S
0.75
0.13
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.01
0.00
(loc)
5-6
5-6
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 29 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins: 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 5=264/Mechanical, 2=352/0-3-8
Max Horz 2=69(LC 11)
Max Uplift 5=-66(LC 8), 2=-64(LC 11)
Max Grav 5=423(LC 30), 2=438(LC 31)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-436/85, 4-5=-268/41
WEBS 3-5=-262/69
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This
connection is for uplift only and does not consider lateral forces.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Use Simpson Strong-Tie TJC37 (4 nail 90-150) or equivalent at 1-6-0 from the left end to connect truss(es) to back face of bottom
chord, skewed 39.8 deg.to the right, sloping 0.0 deg. down.
12) Use Simpson Strong-Tie LU24 (4-10d Girder, 2-10dx1 1/2 Truss, Single Ply Girder) or equivalent at 4-0-12 from the left end to
connect truss(es) to back face of bottom chord.
13) Fill all nail holes where hanger is in contact with lumber.
14) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 45 lb down and 44 lb up at
2-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
15) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
Continued LOAD CASE(on page S) Standard 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.56
0.09
0.14
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
7
7
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 45 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 6=306/Mechanical, 2=406/0-3-8
Max Horz 2=204(LC 11)
Max Uplift 6=-111(LC 11)
Max Grav 6=464(LC 34), 2=598(LC 34)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-454/0, 3-4=-323/0
BOT CHORD 6-7=-65/327
WEBS 4-6=-384/76
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
6=111.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This
connection is for uplift only and does not consider lateral forces.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Use Simpson Strong-Tie TJC37 (4 nail, 30-90) or equivalent at 2-0-0 from the left end to connect truss(es) to front face of bottom
chord, skewed 45.0 deg.to the left, sloping 0.0 deg. down.
12) Fill all nail holes where hanger is in contact with lumber.
13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
Special
LU24
LU24 LU24 LU24
LU24
LU24
LU24 LU24
LU24
LU24
LU24
LU24 LU24
3-8-11
3-8-11
7-2-4
3-5-9
11-10-7
4-8-3
16-6-11
4-8-3
21-2-14
4-8-3
25-11-1
4-8-3
30-7-5
4-8-3
35-3-8
4-8-3
38-2-10
2-11-2
41-1-12
2-11-2
43-5-0
2-3-4
-1-0-0
1-0-0
3-8-11
3-8-11
7-2-4
3-5-9
11-10-7
4-8-3
16-6-11
4-8-3
21-2-14
4-8-3
25-11-1
4-8-3
30-7-5
4-8-3
35-3-8
4-8-3
38-2-10
2-11-2
41-1-12
2-11-2
43-5-0
2-3-4
0-7-7
6-7-5
2-8-9
2-0-0
6-7-5
10.00 12
Plate Offsets (X,Y)-- [2:0-8-0,0-0-7], [3:0-1-8,0-1-8], [4:0-9-4,0-2-4], [13:0-2-12,0-2-4], [14:0-4-4,0-2-0], [15:0-3-0,0-1-8], [16:Edge,0-3-8], [19:0-3-8,0-4-4], [20:Edge,0-3-8],
[21:0-2-8,0-4-8], [27:0-2-12,0-2-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.59
0.85
0.97
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.33
-0.63
0.12
(loc)
24
24
16
l/defl
>999
>827
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 638 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x8 SP No.2 *Except*
12-20: 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-6-6 oc purlins,
except end verticals, and 2-0-0 oc purlins (3-7-11 max.): 4-14.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 2=4889/0-3-8 (req. 0-4-0), 16=4557/Mechanical
Max Horz 2=173(LC 11)
Max Uplift 2=-1295(LC 8), 16=-1477(LC 7)
Max Grav 2=5138(LC 33), 16=5068(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-7059/1858, 3-4=-6768/1923, 4-5=-7503/2208, 5-6=-7502/2208, 6-8=-9465/2813,
8-9=-9465/2813, 9-10=-7580/2320, 10-12=-8145/2468, 12-13=-8134/2466,
13-14=-2696/823, 14-15=-3444/1033, 15-16=-4905/1448
BOT CHORD 2-29=-1450/5217, 28-29=-1450/5217, 27-28=-1488/5154, 25-27=-2683/9037,
24-25=-2683/9037, 22-24=-2697/8857, 21-22=-2697/8857, 20-21=-104/342,
19-20=-98/274, 12-19=-418/80, 18-19=-1690/5592, 17-18=-1690/5592
WEBS 3-29=-30/388, 3-28=-379/162, 4-28=-267/1085, 4-27=-1226/3870, 5-27=-539/113,
6-27=-2536/810, 6-25=-357/1023, 6-24=-252/800, 8-24=-271/90, 9-24=-196/1004,
9-22=-249/605, 9-21=-2110/618, 10-21=-904/229, 19-21=-2425/7910, 10-19=-205/767,
13-19=-1312/4279, 13-18=-221/564, 13-17=-5212/1597, 14-17=-635/1984,
15-17=-1110/3724
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
5) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
6) Unbalanced snow loads have been considered for this design.
7) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
8) Provide adequate drainage to prevent water ponding.
Continued 9) All plates on are page MT20 2 plates unless otherwise indicated.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
4-3-8
0-10-1
6-1-8
1-10-0
10-3-0
4-1-8
14-6-8
4-3-8
16-6-6
1-11-14
18-10-0
2-3-10
-1-0-0
1-0-0
1-10-10
1-10-10
3-5-7
1-6-13
5-1-7
1-8-0
6-1-8
1-0-1
10-3-0
4-1-8
14-6-8
4-3-8
16-6-6
1-11-14
18-10-0
2-3-10
0-9-7
4-2-14
9-4-7
0-9-7
2-0-0
2-2-14
12.00 12
6.00 12
Plate Offsets (X,Y)-- [2:0-4-1,0-2-8], [3:0-6-12,0-2-8], [4:0-6-12,0-5-0], [5:0-6-0,0-5-8], [6:0-1-12,0-2-4], [7:0-4-12,0-2-8], [8:0-0-12,0-1-8], [9:0-1-4,0-1-8], [10:0-4-1,0-2-8],
[12:0-6-0,0-5-12], [14:0-5-8,0-6-0], [15:1-1-4,0-6-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.82
0.87
0.78
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.22
-0.44
0.42
(loc)
13-14
13-14
10
l/defl
>999
>511
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 476 lb FT = 10%
GRIP
169/123
148/108
LUMBER-
TOP CHORD 2x6 SPF No.2 *Except*
4-5: 2x8 SP No.2, 5-7: 2x6 SP No.1
BOT CHORD 2x8 SP 2250F 1.8E *Except*
2-15: 2x8 SP No.2
WEBS 2x4 SPF No.2 *Except*
6-14,4-15: 2x6 SPF No.2, 7-13: 2x4 SPF-S 1650F 1.6E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-7-10 oc purlins,
except
2-0-0 oc purlins (6-0-0 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 10=10866/0-3-8 (req. 0-5-11), 2=7964/0-3-8 (req. 0-4-5)
Max Horz 2=180(LC 58)
Max Uplift 2=-433(LC 11)
Max Grav 10=10866(LC 1), 2=8298(LC 36)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-17794/1030, 3-4=-19712/1141, 4-5=-15923/934, 5-6=-22602/1170, 6-7=-11168/0,
7-8=-11025/0, 8-9=-19290/0, 9-10=-18623/0
BOT CHORD 2-15=-815/12394, 3-15=-150/3442, 14-15=-1160/21453, 13-14=-943/17018,
12-13=0/13226, 11-12=0/14022, 10-11=0/13182
WEBS 5-15=-8343/394, 5-14=-8441/413, 6-14=-1786/12640, 6-13=-10851/1585, 7-13=0/15103,
8-13=-6414/0, 8-12=0/9129, 9-12=0/1710, 9-11=0/278, 4-15=-645/12009
NOTES-
1) n/a
2) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x8 - 4 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 14-5 2x4 - 1 row at 0-7-0 oc, 2x6 - 2 rows staggered at 0-9-0
oc.
3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
4) Unbalanced roof live loads have been considered for this design.
5) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
6) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
7) Unbalanced snow loads have been considered for this design.
8) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
9) Provide adequate drainage to prevent water ponding.
10) All plates are MT20 plates unless otherwise indicated.
Continued on page 2
PLY-TO-PLY CONNECTION REQUIRES THAT AN APPROVED
FACE MOUNT HANGER (SPECIFIED BY OTHERS) IS REQUIRED FOR
LOADS REPORTED IN NOTES. FACE MOUNT HANGER SHALL BE
ATTACHED WITH A MINIMUM OF 0.148"x 3" NAILS PER HANGER
MANUFACTURER SPECIFICATIONS.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
19-7-1
1-8-5
22-0-0
2-4-15
2-4-15
2-4-15
4-1-4
1-8-5
6-5-7
2-4-3
7-3-5
0-9-14
11-0-0
3-8-11
14-8-11
3-8-11
15-6-9
0-9-14
17-10-12
2-4-3
19-7-1
1-8-5
22-0-0
2-4-15
23-0-0
1-0-0
0-10-15
11-10-15
0-10-15
12.00 12
Plate Offsets (X,Y)-- [4:0-9-0,0-0-4], [8:0-9-0,0-0-4], [10:0-0-0,0-0-0], [11:0-0-0,0-0-0], [14:0-3-0,0-7-12], [15:0-3-0,0-7-12]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.96
0.93
0.44
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Attic
in
-0.30
-0.46
0.02
-0.21
(loc)
14-15
14-15
11
14-15
l/defl
>872
>570
n/a
810
L/d
480
240
n/a
360
PLATES
MT20
Weight: 221 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x8 SP No.2
BOT CHORD 2x10 SP No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 14-15.
JOINTS 1 Brace at Jt(s): 17
REACTIONS. (lb/size) 1=978/0-3-8, 11=1050/0-3-8
Max Horz 1=-226(LC 11)
Max Grav 1=1301(LC 25), 11=1363(LC 25)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1606/0, 2-4=-2096/0, 4-5=-1050/66, 7-8=-1052/67, 8-10=-2096/0, 10-11=-1592/0
BOT CHORD 1-16=-12/1206, 15-16=-17/1189, 14-15=0/1097, 13-14=0/1057, 11-13=0/1082
WEBS 2-16=-885/43, 4-15=0/1560, 5-17=-1082/63, 7-17=-1082/63, 8-14=0/1560,
10-13=-899/49
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 8-0-0, Exterior(2) 8-0-0 to 11-0-0,
Interior(1) 14-0-0 to 20-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Ceiling dead load (5.0 psf) on member(s). 4-5, 7-8, 5-17, 7-17; Wall dead load (5.0psf) on member(s).4-15, 8-14
8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (0.0 psf) applied only to room. 14-15
9) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
19-8-5
1-9-9
22-0-0
2-3-11
-1-0-0
1-0-0
2-3-11
2-3-11
4-1-4
1-9-9
6-5-7
2-4-3
7-3-5
0-9-14
11-0-0
3-8-11
14-8-11
3-8-11
15-6-9
0-9-14
17-10-12
2-4-3
19-8-5
1-9-9
22-0-0
2-3-11
23-0-0
1-0-0
0-10-15
11-10-15
0-10-15
12.00 12
Plate Offsets (X,Y)-- [5:0-9-0,0-0-4], [9:0-9-0,0-0-4], [10:0-0-0,0-0-0], [11:0-0-0,0-0-0], [12:0-0-0,0-0-0], [15:0-3-0,0-7-12], [16:0-3-0,0-7-12]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.96
0.93
0.43
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Attic
in
-0.30
-0.46
0.02
-0.21
(loc)
15-16
15-16
12
15-16
l/defl
>869
>568
n/a
806
L/d
480
240
n/a
360
PLATES
MT20
Weight: 225 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x8 SP No.2
BOT CHORD 2x10 SP No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 15-16.
JOINTS 1 Brace at Jt(s): 18
REACTIONS. (lb/size) 2=1048/0-3-8, 12=1048/0-3-8
Max Horz 2=-232(LC 11)
Max Grav 2=1362(LC 24), 12=1362(LC 25)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1571/0, 3-5=-2072/0, 5-6=-1049/66, 8-9=-1049/65, 9-11=-2071/0, 11-12=-1567/0
BOT CHORD 2-17=-9/1192, 16-17=-14/1173, 15-16=0/1094, 14-15=0/1049, 12-14=0/1074
WEBS 3-17=-890/39, 5-16=0/1522, 6-18=-1080/57, 8-18=-1080/57, 9-15=0/1522,
11-14=-890/47
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-2-14, Interior(1) 2-2-14 to 8-0-0, Exterior(2) 8-0-0 to 11-0-0,
Interior(1) 14-0-0 to 19-9-2 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Ceiling dead load (5.0 psf) on member(s). 5-6, 8-9, 6-18, 8-18; Wall dead load (5.0psf) on member(s).5-16, 9-15
8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (0.0 psf) applied only to room. 15-16
9) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
27-10-0
4-7-0
32-8-8
4-10-8
0-7-7
12-0-0
9-0-0
3-0-0
12-0-0
10.00 12
Plate Offsets (X,Y)-- [5:0-6-4,0-2-0], [9:0-1-12,0-2-0], [11:0-1-12,0-2-0], [12:0-2-12,Edge]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.97
0.76
0.84
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.32
-0.67
0.07
(loc)
11-12
11-12
11
l/defl
>999
>576
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 199 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
4-5: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2 *Except*
11-12: 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals, and
2-0-0 oc purlins (4-6-3 max.): 5-10.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 13-14.
1 Row at midpt 7-12
WEBS 1 Row at midpt 10-11, 5-14, 6-14, 6-12, 9-11
REACTIONS. (lb/size) 11=1295/0-3-8, 2=1367/0-3-8
Max Horz 2=368(LC 13)
Max Uplift 11=-101(LC 10)
Max Grav 11=1932(LC 32), 2=1598(LC 33)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2062/13, 3-5=-2029/173, 5-6=-1161/111, 6-7=-1437/98, 7-9=-1442/95
BOT CHORD 2-16=-228/1464, 14-16=-131/1091, 7-12=-498/81, 11-12=-69/890
WEBS 3-16=-657/276, 5-16=-203/1040, 5-14=-157/416, 6-14=-791/138, 12-14=-119/1445,
9-12=-55/1158, 9-11=-1838/150
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-5-0, Exterior(2) 9-5-0 to 13-7-15,
Interior(1) 17-10-13 to 29-6-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 11 and 2. This
connection is for uplift only and does not consider lateral forces.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
6-3-0
25-10-7
6-3-0
32-5-0
6-6-8
1-7-5
2-5-1
9-0-0
7.95 12
10.00 12
Plate Offsets (X,Y)-- [2:0-3-12,0-2-0], [3:0-4-0,0-3-4], [4:0-2-8,0-1-12], [7:0-2-0,Edge], [11:0-1-8,0-1-8], [15:0-5-0,0-2-4], [16:0-1-12,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.84
0.74
0.78
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.24
-0.51
0.08
(loc)
11-13
13-15
10
l/defl
>999
>755
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 171 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
10-12: 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-4-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (3-1-4 max.): 2-3, 5-9.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 9-10, 6-13, 6-11
2 Rows at 1/3 pts 8-10
REACTIONS. (lb/size) 10=1285/0-3-8, 16=1285/Mechanical
Max Horz 16=221(LC 13)
Max Uplift 10=-85(LC 10)
Max Grav 10=1921(LC 37), 16=1292(LC 38)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2839/18, 3-4=-4003/91, 4-5=-1932/94, 5-6=-1473/106, 6-8=-1410/55,
9-10=-310/49
BOT CHORD 15-16=-222/661, 13-15=-175/1809, 11-13=-94/1608, 10-11=-61/1140
WEBS 2-15=0/2451, 3-15=-2729/102, 4-15=-32/2147, 4-13=-924/141, 5-13=0/836,
6-13=-276/278, 6-11=-584/116, 8-11=0/878, 8-10=-1896/105, 2-16=-1358/52
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 4-2-12, Interior(1) 4-2-12 to 10-4-7, Exterior(2) 10-4-7 to 13-4-7,
Interior(1) 16-4-7 to 29-3-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Refer to girder(s) for truss to truss connections.
7) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 10. This
connection is for uplift only and does not consider lateral forces.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
7.95 12
10.00 12
Plate Offsets (X,Y)-- [2:0-3-12,0-2-0], [4:0-6-4,0-2-0], [6:0-2-0,Edge], [9:0-2-12,0-2-0], [10:0-1-8,0-1-8], [14:0-4-0,0-1-8], [15:0-1-12,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.84
0.82
0.77
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.23
-0.46
0.08
(loc)
12-14
12-14
9
l/defl
>999
>843
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 172 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
3-4: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-11-11 oc purlins,
except end verticals, and 2-0-0 oc purlins (3-1-13 max.): 2-3, 4-8.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 8-9, 4-12, 5-12, 5-10
2 Rows at 1/3 pts 7-9
REACTIONS. (lb/size) 9=1285/0-3-8, 15=1285/Mechanical
Max Horz 15=195(LC 13)
Max Uplift 9=-84(LC 10)
Max Grav 9=1921(LC 37), 15=1288(LC 37)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2050/53, 3-4=-2784/173, 4-5=-1548/96, 5-7=-1308/54, 8-9=-307/49
BOT CHORD 14-15=-193/814, 12-14=-123/1449, 10-12=-98/1606, 9-10=-59/1142
WEBS 2-14=0/1630, 3-14=-1939/177, 4-14=-123/1464, 4-12=-81/427, 5-12=-162/331,
5-10=-662/97, 7-10=0/892, 7-9=-1907/101, 2-15=-1406/48
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 5-11-2, Interior(1) 5-11-2 to 10-4-7, Exterior(2) 10-4-7 to 13-4-7,
Interior(1) 16-4-7 to 29-3-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Refer to girder(s) for truss to truss connections.
7) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 9. This
connection is for uplift only and does not consider lateral forces.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
21-3-7
7-11-0
29-2-8
7-11-1
36-11-12
7-9-4
37-1-9
0-1-13
38-11-1
1-9-8
42-1-8
3-2-7
2-1-0
2-1-0
4-7-9
2-6-9
10-3-6
5-7-14
13-4-7
3-1-0
20-4-7
7-0-1
27-4-8
7-0-1
34-4-9
7-0-1
37-1-9
2-9-0
38-11-1
1-9-8
42-1-8
3-2-7
43-1-8
1-0-0
3-1-13
4-8-14
6-5-2
9-0-0
5-2-10
10-0-0
1-4-15
1-0-0
10-0-0
9.14 12
7.95 12
10.00 12
18.00 12
Plate Offsets (X,Y)-- [3:0-3-0,0-2-3], [5:0-3-4,0-2-4], [8:0-1-12,0-1-8], [9:0-3-8,0-2-0], [11:0-5-4,0-2-4], [12:0-2-0,0-1-8], [17:0-4-12,Edge], [18:0-3-0,0-1-12], [23:0-3-12,0-1-8],
[24:0-1-12,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.77
0.88
0.95
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.18
-0.43
0.10
(loc)
21-23
21-23
17
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 252 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
5-7,7-9: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-6-11 oc purlins,
except end verticals, and 2-0-0 oc purlins (3-11-15 max.): 3-4, 5-9.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 4-23, 6-21, 6-20, 8-18, 9-17
REACTIONS. (lb/size) 14=-148/0-3-8, 17=2130/(0-3-8 + H10A Simpson Strong-Tie) (req. 0-4-3), 24=1433/Mechanical
Max Horz 24=-202(LC 14)
Max Uplift 14=-402(LC 65), 24=-8(LC 13)
Max Grav 14=108(LC 56), 17=2682(LC 43), 24=1495(LC 43)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1266/111, 3-4=-1062/113, 4-5=-2303/193, 5-6=-1792/178, 6-8=-2031/179,
8-9=-1330/152, 9-10=-37/587, 10-11=-16/529, 11-12=-36/503, 12-14=-77/431
BOT CHORD 23-24=-100/705, 21-23=-93/2030, 20-21=-109/2078, 18-20=-94/1630, 17-18=-38/449,
10-17=-318/80
WEBS 2-23=-16/805, 3-23=0/548, 4-23=-1447/83, 4-21=-735/138, 5-21=-33/1076,
6-21=-464/116, 6-20=-431/97, 8-20=-8/718, 8-18=-1416/148, 9-18=-48/1802,
9-17=-2417/105, 11-17=-393/110, 11-15=-77/257, 2-24=-1541/69, 12-15=-277/93
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 7-7-9, Interior(1) 7-7-9 to 10-3-6, Exterior(2) 10-3-6 to 13-4-7,
Interior(1) 16-4-7 to 31-4-9, Exterior(2) 34-4-9 to 37-3-5, Interior(1) 38-11-1 to 40-1-8 zone; cantilever left and right exposed ;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24.
10) H10A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 17. This connection is
for uplift only and does not consider lateral forces.
11) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 14. This
connection is for uplift only and does not consider lateral forces.
12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
6-4-4
20-10-0
8-1-12
28-11-13
8-1-13
36-11-12
7-11-15
37-1-9
0-1-13
38-11-1
1-9-8
42-1-8
3-2-7
3-3-7
3-3-7
5-5-6
2-1-15
6-3-15
0-10-10
12-8-4
6-4-4
13-4-7
0-8-3
20-4-7
7-0-1
27-4-8
7-0-1
34-4-9
7-0-1
37-1-9
2-9-0
38-11-1
1-9-8
42-1-8
3-2-7
43-1-8
1-0-0
3-6-7
6-2-5
7-10-2
8-5-2
8-5-3
9-0-0
5-2-10
10-0-0
1-4-15
1-0-0
10-0-0
9.72 12
9.14 12
7.95 12 10.00 12
18.00 12
Plate Offsets (X,Y)-- [4:0-8-8,0-1-12], [6:0-5-4,0-2-4], [9:0-1-12,0-1-8], [10:0-3-8,0-2-0], [12:0-5-4,0-2-4], [13:0-2-0,0-1-8], [18:0-4-12,Edge], [19:0-3-0,0-1-12], [23:0-4-0,0-1-12]
, [25:0-1-12,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.55
0.82
0.92
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.19
-0.43
0.08
(loc)
21-23
21-23
18
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 274 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SP 2400F 2.0E *Except*
1-2,2-3,10-12,12-14: 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-2-1 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-9-13 max.): 4-5, 6-10.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 4-24, 5-23, 6-21, 7-21, 9-19, 10-18, 2-25
REACTIONS. (lb/size) 15=-83/0-3-8, 18=2057/(0-3-8 + H10A Simpson Strong-Tie) (req. 0-4-1), 25=1441/Mechanical
Max Horz 25=-208(LC 14)
Max Uplift 15=-309(LC 69), 18=-16(LC 9), 25=-8(LC 10)
Max Grav 15=153(LC 60), 18=2577(LC 45), 25=1506(LC 45)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1310/134, 3-4=-1224/136, 4-5=-1815/158, 5-6=-2149/209, 6-7=-2127/176,
7-9=-2085/170, 9-10=-1409/148, 10-11=-50/495, 11-12=-29/436, 12-13=-48/413,
13-15=-122/337
BOT CHORD 24-25=-108/833, 23-24=-100/1107, 21-23=-120/1801, 19-21=-103/1669, 18-19=-36/491,
11-18=-314/80
WEBS 2-24=-35/612, 4-24=-506/158, 4-23=-92/1273, 5-23=-1409/171, 6-23=-53/1044,
6-21=-74/500, 7-21=-771/133, 9-21=-30/695, 9-19=-1393/165, 10-19=-68/1809,
10-18=-2341/131, 12-18=-325/120, 2-25=-1571/57
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 3-3-7, Interior(1) 3-3-7 to 5-5-6, Exterior(2) 5-5-6 to 6-3-15,
Interior(1) 9-3-15 to 12-8-4, Exterior(2) 13-4-7 to 37-3-5, Interior(1) 37-3-5 to 38-11-1, Exterior(2) 40-1-8 to 43-1-8 zone; cantilever
left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25.
11) H10A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 18. This connection is
for uplift only and does not consider lateral forces.
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
20-9-15
8-1-13
28-11-12
8-1-13
36-11-12
8-0-0
37-1-9
0-1-13
38-11-1
1-9-8
42-1-8
3-2-7
3-3-6
3-3-6
5-5-5
2-1-15
6-3-15
0-10-10
12-8-2
6-4-2
13-4-7
0-8-5
20-4-8
7-0-1
27-4-8
7-0-1
34-4-9
7-0-1
37-1-9
2-9-0
38-11-1
1-9-8
42-1-8
3-2-7
43-1-8
1-0-0
3-6-7
6-2-5
7-10-1
8-5-2
8-5-1
9-0-0
5-2-10
10-0-0
1-4-15
1-0-0
10-0-0
9.72 12
9.14 12
7.96 12 10.00 12
18.00 12
Plate Offsets (X,Y)-- [4:0-8-8,0-1-12], [6:0-5-4,0-2-4], [9:0-1-12,0-1-8], [10:0-3-8,0-2-0], [12:0-5-4,0-2-4], [13:0-2-0,0-1-8], [18:0-4-12,Edge], [19:0-3-0,0-1-12], [23:0-4-0,0-1-12]
, [25:0-1-12,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.55
0.82
0.92
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.19
-0.43
0.08
(loc)
21-23
21-23
18
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 274 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SP 2400F 2.0E *Except*
1-2,2-3,10-12,12-14: 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-2-1 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-9-13 max.): 4-5, 6-10.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 4-24, 5-23, 6-21, 7-21, 9-19, 10-18, 2-25
REACTIONS. (lb/size) 15=-83/0-3-8, 18=2058/(0-3-8 + H10A Simpson Strong-Tie) (req. 0-4-1), 25=1441/Mechanical
Max Horz 25=-208(LC 14)
Max Uplift 15=-310(LC 69), 18=-16(LC 9), 25=-8(LC 10)
Max Grav 15=152(LC 60), 18=2578(LC 45), 25=1506(LC 45)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1310/134, 3-4=-1225/136, 4-5=-1815/158, 5-6=-2154/209, 6-7=-2127/176,
7-9=-2085/170, 9-10=-1409/148, 10-11=-50/496, 11-12=-29/437, 12-13=-48/414,
13-15=-121/338
BOT CHORD 24-25=-108/833, 23-24=-99/1107, 21-23=-120/1801, 19-21=-102/1668, 18-19=-36/490,
11-18=-314/80
WEBS 2-24=-35/612, 4-24=-505/157, 4-23=-92/1276, 5-23=-1413/172, 6-23=-53/1047,
6-21=-74/500, 7-21=-771/133, 9-21=-29/696, 9-19=-1393/165, 10-19=-68/1809,
10-18=-2341/131, 12-18=-326/120, 2-25=-1571/57
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 3-3-6, Interior(1) 3-3-6 to 5-5-5, Exterior(2) 5-5-5 to 6-3-15,
Interior(1) 9-3-15 to 12-8-2, Exterior(2) 13-4-7 to 37-3-5, Interior(1) 37-3-5 to 38-11-1, Exterior(2) 40-1-8 to 43-1-8 zone; cantilever
left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25.
11) H10A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 18. This connection is
for uplift only and does not consider lateral forces.
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
21-3-7
7-11-0
29-2-8
7-11-1
36-11-12
7-9-4
37-1-9
0-1-13
42-1-8
4-11-15
2-0-15
2-0-15
4-7-9
2-6-10
10-3-5
5-7-12
13-4-7
3-1-1
20-4-8
7-0-1
27-4-8
7-0-1
34-4-9
7-0-1
37-1-9
2-9-0
38-11-1
1-9-8
42-1-8
3-2-7
43-1-8
1-0-0
3-1-13
4-8-13
6-5-3
9-0-0
5-2-10
10-0-0
1-4-15
1-0-0
10-0-0
9.14 12
7.96 12
10.00 12
18.00 12
Plate Offsets (X,Y)-- [3:0-3-0,0-2-3], [5:0-9-4,0-2-4], [8:0-1-12,0-1-8], [9:0-3-4,0-2-0], [11:0-3-0,0-1-12], [12:0-2-0,0-1-8], [16:0-6-0,0-2-0], [17:0-3-0,0-1-12], [22:0-3-12,0-1-8],
[23:0-1-12,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.77
0.90
0.86
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.18
-0.43
0.11
(loc)
20-22
20-22
16
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 246 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
5-7,7-9: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-5-15 oc purlins,
except end verticals, and 2-0-0 oc purlins (3-11-6 max.): 3-4, 5-9.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 14-15.
WEBS 1 Row at midpt 4-22, 6-20, 6-19, 8-17, 9-16
REACTIONS. (lb/size) 14=83/0-3-8, 16=1871/(0-3-8 + H10A Simpson Strong-Tie) (req. 0-3-12), 23=1462/Mechanical
Max Horz 23=-202(LC 14)
Max Uplift 14=-245(LC 65), 23=-16(LC 13)
Max Grav 14=262(LC 56), 16=2401(LC 57), 23=1530(LC 43)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1299/126, 3-4=-1089/125, 4-5=-2373/226, 5-6=-1846/203, 6-8=-2117/219,
8-9=-1448/208, 9-10=-83/433, 10-11=-38/374, 11-12=-74/385, 12-14=-209/297
BOT CHORD 22-23=-100/713, 20-22=-94/2090, 19-20=-111/2160, 17-19=-96/1740, 16-17=-41/551,
10-16=-315/77
WEBS 2-22=-21/825, 3-22=0/566, 4-22=-1496/105, 4-20=-742/143, 5-20=-54/1114,
6-20=-509/126, 6-19=-395/96, 8-19=-7/683, 8-17=-1379/147, 9-17=-47/1759,
9-16=-2192/100, 2-23=-1578/87
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 7-7-9, Interior(1) 7-7-9 to 10-3-5, Exterior(2) 10-3-5 to 13-4-7,
Interior(1) 16-4-7 to 31-4-9, Exterior(2) 34-4-9 to 37-3-5, Interior(1) 38-11-1 to 40-1-8 zone; cantilever left and right exposed ;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23.
11) H10A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 16. This connection is
for uplift only and does not consider lateral forces.
12) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 14. This
Continued connection on page is for 2 uplift only and does not consider lateral forces.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
2-5-13
4-5-3
9-0-0
6-8-9
9-0-0
7.96 12
10.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-2-3], [4:0-9-4,0-2-4], [8:0-3-4,0-2-0], [11:0-1-8,0-1-8], [15:0-2-8,0-2-4], [16:0-1-12,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.67
0.53
0.78
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.30
-0.62
0.07
(loc)
13-15
13-15
10
l/defl
>999
>713
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 214 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
3-4,4-6,6-8: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-7-9 oc purlins,
except end verticals, and 2-0-0 oc purlins (3-3-10 max.): 2-3, 4-8.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-13, 5-11, 7-11, 8-10
REACTIONS. (lb/size) 16=1473/Mechanical, 10=1473/Mechanical
Max Horz 16=157(LC 13)
Max Uplift 10=-20(LC 10)
Max Grav 16=1540(LC 38), 10=2013(LC 38)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2516/94, 3-4=-3404/226, 4-5=-2077/134, 5-7=-1802/111, 7-8=-1822/113
BOT CHORD 15-16=-148/986, 13-15=-101/1830, 11-13=-100/2179, 10-11=-26/588
WEBS 2-15=-8/2021, 3-15=-2288/210, 4-15=-109/1567, 4-13=-38/636, 5-13=-330/292,
5-11=-611/64, 7-11=-798/137, 8-11=-68/1932, 2-16=-1716/71, 8-10=-2016/111
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 5-11-3, Interior(1) 5-11-3 to 10-4-7, Exterior(2) 10-4-7 to 13-4-7,
Interior(1) 16-4-7 to 31-4-9, Exterior(2) 34-4-9 to 36-11-12 zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
5-5-13
4-2-15
9-5-2
3-11-5
13-4-7
3-11-5
20-4-8
7-0-1
27-4-8
7-0-1
34-4-9
7-0-1
37-1-8
2-8-15
1-7-6
2-5-3
9-0-0
6-8-9
9-0-0
7.96 12
10.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-2-3], [3:0-3-4,0-3-4], [4:0-2-8,0-1-12], [5:0-3-12,0-2-8], [9:0-3-4,0-2-0], [11:Edge,0-2-0], [12:0-3-0,0-1-12], [17:0-2-0,0-1-12], [18:0-2-12,0-2-4],
[19:0-1-12,0-2-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.67
0.86
0.78
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.25
-0.57
0.13
(loc)
14-15
15-17
11
l/defl
>999
>771
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 205 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
5-7,7-9: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-8 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-10-1 max.): 2-3, 5-9.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-18, 6-15, 6-14, 8-12, 9-11
REACTIONS. (lb/size) 19=1473/Mechanical, 11=1473/Mechanical
Max Horz 19=183(LC 13)
Max Uplift 11=-21(LC 10)
Max Grav 19=1540(LC 38), 11=2013(LC 38)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-899/47, 3-4=-4453/157, 4-5=-2428/143, 5-6=-1862/144, 6-8=-2148/133,
8-9=-1517/98
BOT CHORD 18-19=-180/804, 17-18=-190/3522, 15-17=-153/2243, 14-15=-97/2185, 12-14=-80/1774,
11-12=-25/591
WEBS 2-18=0/1399, 3-18=-2952/43, 3-17=-1599/124, 4-17=-50/2074, 4-15=-974/139,
5-15=0/1098, 6-15=-542/130, 6-14=-387/106, 8-14=-20/648, 8-12=-1355/150,
9-12=-51/1765, 2-19=-1653/56, 9-11=-2038/100
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) 0-1-12 to 4-2-13, Interior(1) 4-2-13 to 10-4-7, Exterior(2) 10-4-7 to 13-4-7,
Interior(1) 16-4-7 to 31-4-9, Exterior(2) 34-4-9 to 36-11-12 zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Provide adequate drainage to prevent water ponding.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
9-5-4
43-5-0
9-8-12
-1-0-0
1-0-0
6-10-5
6-10-5
13-7-15
6-9-9
18-11-7
5-3-9
24-3-0
5-3-9
29-5-9
5-2-9
34-8-1
5-2-9
38-10-13
4-2-11
43-5-0
4-6-3
0-7-7
12-0-0
1-8-9
3-0-0
12-0-0
10.00 12
Plate Offsets (X,Y)-- [5:0-6-4,0-2-0], [6:0-1-12,0-2-0], [10:0-4-0,0-1-12], [16:0-2-8,Edge], [18:0-1-3,0-2-4]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.67
0.87
0.83
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.37
-0.71
0.18
(loc)
14-16
14-16
13
l/defl
>999
>734
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 253 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
4-5,1-4: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2 *Except*
15-16,13-15: 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-7-4 oc purlins,
except end verticals, and 2-0-0 oc purlins (2-11-15 max.): 5-10.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 17-18.
1 Row at midpt 7-16
WEBS 1 Row at midpt 9-14, 11-13
2 Rows at 1/3 pts 6-18
REACTIONS. (lb/size) 2=1795/0-3-8, 13=1724/0-3-8
Max Horz 2=245(LC 13)
Max Grav 2=2000(LC 36), 13=2033(LC 35)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2635/124, 3-5=-2585/271, 5-6=-1926/206, 6-7=-2880/219, 7-9=-2887/217,
9-10=-1975/178, 10-11=-2431/183, 11-12=-294/64, 12-13=-316/58
BOT CHORD 2-20=-122/1901, 18-20=-89/1733, 7-16=-495/91, 14-16=-74/2551, 13-14=-56/1606
WEBS 3-20=-630/271, 5-20=-188/995, 5-18=-81/929, 6-18=-1650/133, 16-18=-109/2448,
6-16=-23/1119, 9-16=-49/642, 9-14=-1324/168, 10-14=-30/1200, 11-14=-94/375,
11-13=-2343/104
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-5-0, Exterior(2) 9-5-0 to 13-7-15,
Interior(1) 17-10-13 to 30-5-3, Exterior(2) 34-8-1 to 43-3-4 zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2 and 13. This
connection is for uplift only and does not consider lateral forces.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
8-7-2
43-5-0
8-8-15
-1-0-0
1-0-0
6-10-5
6-10-5
13-7-15
6-9-9
19-10-7
6-2-8
26-0-15
6-2-8
30-4-8
4-3-9
34-8-1
4-3-9
38-10-13
4-2-11
43-5-0
4-6-3
0-7-7
12-0-0
1-8-9
3-0-0
12-0-0
10.00 12
Plate Offsets (X,Y)-- [5:0-6-4,0-2-0], [10:0-4-4,0-2-0], [13:0-1-12,0-2-0], [16:0-2-8,0-2-12], [18:0-1-3,0-2-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.88
0.97
0.99
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.29
-0.55
0.17
(loc)
14-16
14-16
13
l/defl
>999
>935
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 251 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
4-5,1-4: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2 *Except*
15-16,13-15: 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-8-2 oc purlins,
except end verticals, and 2-0-0 oc purlins (2-2-0 max.): 5-10.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. Except:
1 Row at midpt 7-16
WEBS 1 Row at midpt 6-18, 9-14, 11-13
REACTIONS. (lb/size) 2=1795/0-3-8, 13=1724/0-3-8
Max Horz 2=244(LC 13)
Max Grav 2=2000(LC 36), 13=2033(LC 35)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2627/128, 3-5=-2510/253, 5-6=-2004/206, 6-7=-2813/218, 7-9=-2818/216,
9-10=-1841/179, 10-11=-2411/188, 11-12=-287/67, 12-13=-312/62
BOT CHORD 2-20=-124/1897, 18-20=-91/1736, 7-16=-507/92, 14-16=-63/2439, 13-14=-54/1612
WEBS 3-20=-599/258, 5-20=-154/967, 5-18=-87/880, 6-18=-1496/153, 16-18=-111/2429,
6-16=-24/869, 9-16=-60/834, 9-14=-1393/157, 10-14=-39/1221, 11-14=-91/370,
11-13=-2361/94
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-5-0, Exterior(2) 9-5-0 to 13-7-15,
Interior(1) 17-10-13 to 30-4-8, Exterior(2) 34-8-1 to 43-3-4 zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2 and 13. This
connection is for uplift only and does not consider lateral forces.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
6-9-9
19-10-7
6-2-8
26-0-15
6-2-8
34-8-1
8-7-2
43-5-0
8-8-15
-1-0-0
1-0-0
6-10-5
6-10-5
13-7-15
6-9-9
19-10-7
6-2-8
26-0-15
6-2-8
30-4-8
4-3-9
34-8-1
4-3-9
38-10-13
4-2-11
43-5-0
4-6-3
0-7-7
12-0-0
4-5-5
0-3-4
1-8-9
3-0-0
12-0-0
10.00 12
Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-1-8,0-1-8], [5:0-4-0,0-1-4], [6:0-2-0,0-1-12], [10:0-4-4,0-2-0], [16:0-2-8,Edge], [18:0-1-8,0-2-8], [22:0-1-0,0-1-4]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.98
0.85
0.81
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.30
-0.58
0.21
(loc)
14-16
14-16
22
l/defl
>999
>899
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 257 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
4-5: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2 *Except*
15-16,13-15: 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals, and
2-0-0 oc purlins (2-2-0 max.): 5-10.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 17-18.
1 Row at midpt 7-16
WEBS 1 Row at midpt 3-19, 9-14, 11-13
2 Rows at 1/3 pts 6-18
REACTIONS. (lb/size) 2=1795/0-3-8, 22=1724/Mechanical
Max Horz 2=244(LC 13)
Max Grav 2=2000(LC 36), 22=2033(LC 35)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2679/111, 3-5=-2341/201, 5-6=-2154/213, 6-7=-2815/215, 7-9=-2818/214,
9-10=-1840/175, 10-11=-2411/182, 11-12=-294/64, 13-22=-2033/74, 12-13=-316/60
BOT CHORD 2-21=-114/1913, 19-21=-114/1913, 18-19=-84/1746, 7-16=-510/92, 14-16=-63/2439,
13-14=-56/1613
WEBS 3-21=0/329, 3-19=-744/181, 5-19=-39/706, 5-18=-143/867, 6-18=-1696/145,
16-18=-95/2386, 6-16=-18/1157, 9-16=-60/835, 9-14=-1394/156, 10-14=-34/1221,
11-14=-91/371, 11-13=-2353/105
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-5-0, Exterior(2) 9-5-0 to 13-7-15,
Interior(1) 17-10-13 to 30-4-8, Exterior(2) 34-8-1 to 38-11-15 zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) Refer to girder(s) for truss to truss connections.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This
connection is for uplift only and does not consider lateral forces.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
VERTICAL LEGS ARE NOT DESIGNED FOR LATERAL
LOADS IMPOSED BY SUPPORTS (BEARINGS).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
6-9-9
19-10-7
6-2-8
26-0-15
6-2-8
34-8-1
8-7-2
43-5-0
8-8-15
-1-0-0
1-0-0
6-10-5
6-10-5
13-7-15
6-9-9
19-10-7
6-2-8
26-0-15
6-2-8
30-4-8
4-3-9
34-8-1
4-3-9
38-10-13
4-2-11
43-5-0
4-6-3
0-7-7
12-0-0
3-5-5
1-3-4
1-8-9
3-0-0
12-0-0
10.00 12
Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-1-8,0-1-8], [5:0-4-0,0-1-4], [6:0-2-0,0-1-12], [10:0-4-4,0-2-0], [16:0-2-8,Edge], [18:0-1-8,0-2-8], [22:0-1-0,0-1-4]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.98
0.85
0.81
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.30
-0.57
0.20
(loc)
14-16
14-16
22
l/defl
>999
>903
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 256 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
4-5: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2 *Except*
15-16,13-15: 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals, and
2-0-0 oc purlins (2-2-0 max.): 5-10.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 17-18.
1 Row at midpt 7-16
WEBS 1 Row at midpt 3-19, 9-14, 11-13
2 Rows at 1/3 pts 6-18
REACTIONS. (lb/size) 2=1795/0-3-8, 22=1724/Mechanical
Max Horz 2=244(LC 13)
Max Grav 2=2000(LC 36), 22=2033(LC 35)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2679/111, 3-5=-2341/201, 5-6=-2154/213, 6-7=-2815/215, 7-9=-2818/214,
9-10=-1840/175, 10-11=-2411/182, 11-12=-294/64, 13-22=-2033/74, 12-13=-316/60
BOT CHORD 2-21=-114/1913, 19-21=-114/1913, 18-19=-84/1746, 7-16=-510/92, 14-16=-63/2439,
13-14=-56/1613
WEBS 3-21=0/329, 3-19=-744/181, 5-19=-39/706, 5-18=-143/867, 6-18=-1696/145,
16-18=-95/2386, 6-16=-18/1157, 9-16=-60/835, 9-14=-1394/156, 10-14=-34/1221,
11-14=-91/371, 11-13=-2353/105
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-5-0, Exterior(2) 9-5-0 to 13-7-15,
Interior(1) 17-10-13 to 30-4-8, Exterior(2) 34-8-1 to 38-11-15 zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) Refer to girder(s) for truss to truss connections.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This
connection is for uplift only and does not consider lateral forces.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
VERTICAL LEGS ARE NOT DESIGNED FOR LATERAL
LOADS IMPOSED BY SUPPORTS (BEARINGS).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
43-5-0
8-1-8
-1-0-0
1-0-0
6-10-5
6-10-5
13-7-15
6-9-9
20-8-0
7-0-1
27-8-0
7-0-1
34-8-1
7-0-1
35-3-8
0-7-7
39-2-8
3-11-0
43-5-0
4-2-8
0-7-7
12-0-0
2-8-9
2-0-0
12-0-0
10.00 12
Plate Offsets (X,Y)-- [5:0-6-4,0-2-0], [7:0-4-0,Edge], [9:0-3-12,0-2-8], [14:0-5-8,Edge], [16:0-1-4,0-1-12], [18:0-1-8,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.61
0.97
0.57
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.26
-0.47
0.13
(loc)
16-18
16-18
13
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 268 lb FT = 10%
GRIP
197/144
148/108
LUMBER-
TOP CHORD 2x4 SP 2400F 2.0E *Except*
9-12: 2x4 SPF No.2, 7-9: 2x6 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
17-19: 2x4 SP 2400F 2.0E
WEBS 2x4 SPF No.2
WEDGE
Left: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-10-6 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-6-12 max.): 5-9.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. Except:
1 Row at midpt 10-14
WEBS 1 Row at midpt 6-18, 6-16, 8-16, 8-14, 11-13
REACTIONS. (lb/size) 2=1795/0-3-8, 13=1724/Mechanical
Max Horz 2=244(LC 13)
Max Grav 2=2015(LC 42), 13=2033(LC 35)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2666/128, 3-5=-2551/248, 5-6=-2013/205, 6-8=-2098/207, 8-9=-1579/189,
9-10=-1760/224, 10-11=-2132/192
BOT CHORD 2-20=-124/1943, 18-20=-91/1737, 16-18=-92/2166, 10-14=-58/454, 13-14=-47/1307
WEBS 3-20=-591/255, 5-20=-144/937, 5-18=-85/837, 6-18=-633/195, 6-16=-271/75,
8-14=-840/103, 11-14=-48/531, 11-13=-2233/99, 14-16=-66/2124, 9-14=-58/632
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-5-0, Exterior(2) 9-5-0 to 13-7-15,
Interior(1) 17-10-13 to 30-5-3, Exterior(2) 34-8-1 to 43-3-4 zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
9) Refer to girder(s) for truss to truss connections.
10) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2. This
connection is for uplift only and does not consider lateral forces.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
18-10-0
4-3-8
-1-0-0
1-0-0
2-10-13
2-10-13
4-6-13
1-8-0
5-11-8
1-4-11
10-3-0
4-3-8
14-6-8
4-3-8
18-10-0
4-3-8
19-10-0
1-0-0
0-9-7
3-8-3
9-4-7
0-9-7
2-0-0
1-8-3
12.00 12
6.00 12
Plate Offsets (X,Y)-- [2:0-2-10,0-0-2], [4:0-4-4,0-1-12], [6:0-1-4,0-1-8], [8:0-1-4,0-1-8], [10:0-2-10,0-0-2], [14:0-1-8,0-1-8]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.55
0.55
0.43
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.09
-0.19
0.20
(loc)
14
13-14
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 92 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
SLIDER Left 2x4 SPF No.2 2-2-4, Right 2x4 SPF No.2 3-2-1
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-7-9 oc purlins, except
2-0-0 oc purlins (3-10-3 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 2=811/0-3-8, 10=811/0-3-8
Max Horz 2=-185(LC 11)
Max Uplift 2=-20(LC 13), 10=-9(LC 14)
Max Grav 2=1140(LC 38), 10=811(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1752/88, 4-5=-2155/97, 5-6=-1901/62, 6-7=-1010/76, 7-8=-837/96, 8-10=-1414/0
BOT CHORD 2-15=-126/1160, 14-15=-102/2267, 13-14=-51/1381, 12-13=0/843, 10-12=0/977
WEBS 4-15=-5/1578, 5-15=-562/22, 5-14=-1183/69, 8-12=0/491, 7-13=-46/838, 6-14=-9/831,
6-13=-972/150, 8-13=-431/106
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 4-6-13, Interior(1) 4-6-13 to 7-3-0, Exterior(2) 7-3-0 to 10-3-0,
Interior(1) 13-3-0 to 16-10-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Bearing at joint(s) 2, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2 and 10. This
connection is for uplift only and does not consider lateral forces.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
2-0-0
12.00 12
6.00 12
Plate Offsets (X,Y)-- [2:0-2-10,0-0-2], [5:0-2-0,0-1-8], [8:0-2-10,0-0-2], [10:0-5-4,0-3-0], [11:0-5-4,0-3-0]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.40
0.73
0.27
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.27
-0.65
0.14
(loc)
10-11
10-11
8
l/defl
>752
>312
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 84 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
SLIDER Left 2x4 SPF No.2 3-2-1, Right 2x4 SPF No.2 3-2-1
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-8-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 2=744/0-3-8, 8=744/0-3-8
Max Horz 2=-185(LC 11)
Max Uplift 2=-10(LC 13), 8=-10(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1369/35, 4-5=-1316/259, 5-6=-1178/148, 6-8=-1345/0
BOT CHORD 2-11=-65/1110, 10-11=0/473, 8-10=0/971
WEBS 5-10=-134/855, 6-10=-219/275, 5-11=-234/966, 4-11=-219/255
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-7-0, Exterior(2) 5-7-0 to 8-7-0,
Interior(1) 11-7-0 to 15-2-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2 and 8. This
connection is for uplift only and does not consider lateral forces.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017
8-7-0
18-2-0
1-0-0
0-9-7
9-4-7
0-9-7
2-0-0
12.00 12
6.00 12
Plate Offsets (X,Y)-- [12:0-3-0,0-1-4], [22:0-3-0,0-1-4]
LOADING (psf)
TCLL (roof)
Snow (Pf)
TCDL
BCLL
BCDL
20.0
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.14
0.07
0.24
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
11
11
12
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 82 lb FT = 10%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. All bearings 17-2-0.
(lb) - Max Horz 22=-185(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 12, 20, 14, 18, 19, 16, 15 except 22=-118(LC 9), 21=-136(LC 13),
13=-128(LC 14)
Max Grav All reactions 250 lb or less at joint(s) 22, 12, 20, 14, 18, 19, 21, 16, 15, 13 except 17=280(LC 14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 6-17=-285/208
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 5-7-0, Corner(3) 5-7-0 to 8-7-0,
Exterior(2) 11-7-0 to 15-2-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15
Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) Gable requires continuous bottom chord bearing.
8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
9) Gable studs spaced at 2-0-0 oc.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 20, 14, 18,
19, 16, 15 except (jt=lb) 22=118, 21=136, 13=128.
12) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 20, 14, 17, 18, 19, 21, 16, 15, 13.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
June 26,2017