Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4
SCOPE DOCUMENT THE DRAWINGS INDICATE THE GENERAL 56OPE OF THE PROJECT IN TERMS OF DESIGN CONCEPT. A5 SCOPE DOCUMENTS, THE DRAWINGS DO NOT NEGE55ARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE PROJECT. THE CONTRACTOR AND 5UBGONTRAGTOR5 SHALL FURNISH ALL ITEMS FOR WORK REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE PROJECT. CCENERAL MOTES A. ALL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS. B. ALL FINISHES SHALL COMPLY WITH FLAME SPREAD AND SMOKE DEVELOPMENT 5TANDARD5 AS L15TED IN THE UNIFORM FIRE CODE AND THE UNIFORM BUILDING, CODE. G. ALL DIMENSIONS ARE FROM FINISHED FAGS OF WALL TO FINISHED FACE OF WALL OR FROM FINISHED FACE OF WALL TO FINISHED FACE OF MASONRY OR FROM FINISHED FACE OF MASONRY TO FINISHED FACE OF MASONRY, UNLESS OTHERWISE NOTED. ALL MA50NRY DIMEN51ONS ARE NOMINAL. D. VERIFY ALL EXI5TIN6 CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY DESIGNER OR ARCHITECT IMMEDIATELY OF ANY DIMENSIONAL CONFLICTS OR CONFLICTS DUE TO UNKNOWN CONDITIONS. WORK SHALL NOT PROCEED UNTIL CONFLICTS ARE RESOLVED. E. EACH CONTRACTOR SHALL EXAMINE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. F. REVIEW ALL DRAWINGS (ARCHITECTURAL, PLUMBING, ELECTRICAL, HVAG) GONGERNING SLEEVES, OUTLETS, BOXES, ANGHOR5, VENTS, OPENINGS, ETC. THAT MAY BE REQUIRED. EACH RESPECTIVE TRADE 15 RESPONSIBLE FOR PROVIDING AND INSTALLING THESE ITEMS. 6. ALL 5UBGONTRAGTOR5 SHALL PROVIDE SHOP DRAWINGS TO DESIGNER FOR REVIEH ON PRODUCTS OF WORK PRIOR TO FABRICATION AS REQUESTED. H. WHERE NIG = NOT IN CONTRACT, BY OTHERS OR BY OWNER, THE G.G. SHALL COORDINATE AND VERIFY ANY AND ALL SPECIFIC REQUIREMENTS OF FRAMING, BLOGKING, HOOK-UP, SERVICES, UTILITIES, ETC. WITH THE OWNER. I. G.G. TO TAPE, SPACKLE, AND SAND SMOOTH ALL GYPSUM WALL CONSTRUCTION AND PREPARE WALLS TO RECEIVE FINISHES. J. G.G. TO PROVIDE AND INSTALL ANY M15GELLANEOUS BLOGKING AS REQUIRED FOR ANY WALL MOUNTED SHELVING, EQUIPMENT OR ACCESSORIES. K. CONTRACTOR SHALL PROVIDE ALL BARRICADES, DUST PARTITIONS, ETC. AS REQUIRED BY LAW AND AS OTHERWISE REQUIRED. L. EACH CONTRACTOR 15 REQU I RED TO REMOVE ALL CARTONS, BOXES, PALLETS, PACKAGING,, UNUSED MATERIALS, TRASH AND DEBRIS CAUSED BY HI5 WORK FROM THE JOB. M. EACH CONTRACTOR 15 RESPONSIBLE FOR PROPER INSTALLATION OF ALL FINISHES SPECIFIED. FINISHES ARE SPECIFIED ONLY. PROPER INSTALLATION METHOD 15 TO BE DETERMINED BY CONTRACTOR AND INSTALLER. FLOOR PLAN PLAN MOTES I. ALL DOORS ARE EXI5TINC TO REMAIN. EXISTING FRAMES TO REMAIN. DOORS TO BE STAINED. FRAMES TO BE PAINTED. ALL DOORS TO HAVE LEVER HANDLES. ANY NEW DOORS AND FRAMES REQUIRED TO MATGH EXI5TIN6. 2. DOORS #I AND #G ARE EXI5TIN6 EXTERIOR DOORS AND FRAMES TO REMAIN. 3. CONTRACTOR TO REPAIR ANY EXISTING DAMAGED DRYWALL. ANY EXISTING WALLS TO BE PATCHED AFTER EXI5TIN6 OUTLETS ARE REMOVED OR FROM DAMA(5E. 4. EXTERIOR WINDOW BLINDS TO BE PROVIDED FOR ALL EXTERIOR HINDOH5 HHERE THEY DO NOT ALREADY EXIST. ALL BLINDS IN SUITE TO MATCH. 5. ALL EXPOSED GORNER5 TO REGEIVE CLEAR PLASTIC CORNER 6UARD5. 6. CONTRACTOR TO PROVIDE CLEAR GAULKINC AROUND ALL DOOR FRAMES (WOOD AND METAL) AFTER DOOR FRAMES HAVE BEEN ADJUSTED AND SET. 7. ANY FIRE ALARM PULL5 AFFECTED BY DEMOLITION TO BE RELOCATED TO NEAREST REMAINING OR NEN HALL. 8. ANY INTERIOR GLAZING REQUIRED TO BE #" LAMINATED SAFETY CLASS. FLOOR PLAN <E)"ED NOTES I. NEW WALL GONSTRUGTION TO ALIGN WITH EXISTING COLUMN, WINDOW MULLION, OR EXISTING WALL. 2. GONTRAGTOR TO REPAIR EXI5TIN6 PLASTIC LAMINATE COUNTER AND CASEWORK DOOR. 3. CONTRACTOR TO PROVIDE NEH DRYWALL CONSTRUCTION AT 8'-O" WITH PLASTIC LAMINATE TOP GAP - PL__. 4. LOCATION FOR EXISTING RESTROOM TO REMAIN. 5. LOCATION OF EXISTING PLUMBING STUB TO REMAIN FOR NEW SINK HOOKUP. 6. EXI5TIN6 GABINETRY TO REMAIN. 7. CONTRACTOR TO PROVIDE BLOCKING IN GEILINC FOR EXAM L1614T. EXACT LOCATION TO BE DETERMINED. ON SITE. 8. LOCATION FOR EXI5TIN6 DEMISING WALL. N rA ■ UZI0 /�0 1� 0 ISO ISO 1� 0 ® 0 0 © J. 0 0 M 0. Ma 0 • IN FLOOR PLAN 5GALE: I/8"=1' -O" NALL TYPE A NO 5GALE '16 LAMINATE AP - PL_ METAL STUDS O.G. rP.BOARD WDE5 ATT INSULATION E 46 STANDARD LINE WALL LEC�END EXI5TIN(9 HALL GON5TRUGTION EX15TI NG, HALL CONSTRUCTION TO 13E REMOVED. NEW PARTIAL HE16HT PARTITION NEH GLAZED HALL NEW INSULATED WALL APPROVAL FOR CONSTRUCTION The Tenant agrees that these drawings and specifications represent the entire scope of work for the Improvements to be provided. The Tenant's signature below represents acceptance of the final design. Any changes to this scope of work Initiated by the Tenant will cause changes In the total cost to the Tenant and In the completion date for the project. Tenant Date OD Z Dks) r O �v Z Q) W Q) D_Z z � O O � Z v� N� �- � u O l� m — 7 N � I� ��d Z=p (S) o N ' 0 0 � W z •} LL 0 • � � O O � Z v� N� �- � u LU l� m — 7 D --z � I� ��d Z=p (S) o N ' 0 0 � W z •} LL 0 LJ 3 toO a •• om �Nv W W Z v� N� �- � u LU l� m — v D --z � I� ��d Z=p � W z LL 0 �Nv W SHEET NUMBER A2. 4 OF 5 SHEETS r r a r 0 Z v� N� �- u LU — v SHEET NUMBER A2. 4 OF 5 SHEETS r r a r 0