Loading...
HomeMy WebLinkAboutA-102 - FIRST FLOOR DEMO & ARCHITECTURAL PLANS - XRAY      TABLE PARK       TABLE PARK A. THIS DEMOLITION PLAN SHALL SERVE TO AID THE CONTRACTORS IN EVALUATION OF THE WORK AND EXTENT OF DEMOLITION. BUT WILL NOT BE HELD TO BE ALL INCLUSIVE. THE CONTRACTORS ARE RESPONSIBLE FOR FIELD VERIFICATION OF EXISTING CONDITIONS, DEMOLITION AND REMOVALS AS REQUIRED FOR THE INSTALLATION OF THE NEW WORK AND FINISHES INDICATED WHETHER OR NOT IT IS SPECIFICALLY NOTED IN THESE DRAWINGS B. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR RELATED WORK. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK WITH OTHER CONTRACTORS. C. DEMOLITION WORK EFFECTING OCCUPIED AREAS OF THE FACILITY WILL BE SCHEDULED IN ADVANCE WITH THE OWNER THROUGH CONSTRUCTION/PROJECT MANAGER. REFER TO SPECIFICATIONS. D. OFFER REMOVED ITEMS SUCH AS DOORS, HARDWARE, PLUMBING FIXTURES, AND TOILET ACCESSORIES TO OWNER BEFORE REMOVAL FROM THE SITE. DETERMINE SALVAGE ITEMS WITH THE OWNER BEFORE DEMOLITION BEGINS. E. ALL CONTRACTORS ARE RESPONSIBLE FOR SECURING CHASES AND RISERS BEFORE DEMOLITION WORK PROCEEDS TO PREVENT DEBRIS FROM FALLING THROUGH INTO OCCUPIED SPACES BELOW. F. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR RELATED WORK AND ITEMS TO BE REMOVED OR RE-INSTALLED IN NEW CONSTRUCTION. TEMPORARY LIGHTING, COMMUNICATION AND MECHANICAL SYSTEMS WILL BE COORDINATED WITH OTHER CONTRACTORS. MAINTAIN ALL LIFE SAFETY DEVISES. G. HOLES LEFT IN THE CONCRETE FLOOR FROM REMOVED ITEMS SUCH AS PLUMBING PIPES, CONDUITS, ETC. WILL BE PATCHED BY RESPECTIVE CONTRACTOR PERFORMING THAT PORTION OF THE WORK. H. FINISH REMOVAL NOTES APPLY TO PARTITIONS/WALLS THAT REMAIN. REMOVE ALL FINISHES FROM WALLS THAT REMAIN WITHIN THE LIMIT OF CONSTRUCTION. I. INTERIOR PARTITIONS AND/OR WALLS SHALL BE REMOVED ENTIRELY FROM DECK ABOVE TO DECK BELOW. J. PRIOR TO SAWCUTTING EXISTING CONCRETE SLAB IS TO BE SCANNED TO VERIFY EXISTING CONDITIONS. DEMOLITION GENERAL NOTES 1000 A RENOVATION GRAPHIC LEGEND EXISTING DOOR TO REMAIN EXISTING DOOR TO BE REMOVED NEW DOOR EXISTING WINDOW TO REMAIN EXISTING WINDOW TO BE REMOVED NEW WINDOW FLOOR PLAN GENERAL NOTES A. GENERAL CONTRACTOR TAKES RESPONSIBILITY FOR COORDINATING REQUIRED WORK WITH ALL TRADES BASED UPON A COMPLETE SET OF CONSTRUCTION DOCUMENTS. B. GENERAL CONTRACTOR TO PROVIDE SOLID BLOCKING FOR ALL WALL MOUNTED CASEWORK, EQUIPMENT, AND ACCESSORIES, INCLUDING TOILET ACCESSORIES AS REQUIRED. C. REFER TO CODE REVIEW PLAN FOR RATED PARTITIONS AND ASSEMBLIES. D. GENERAL CONTRACTOR TO PATCH ALL CONCRETE SLABS AT MECH/ELEC PENETRATIONS. PATCH SLAB FLUSH WITH EXISTING SLAB AND PROVIDE #4 DOWELS INTO EXISTING SLAB AS REQUIRED. E. DAMAGED WALLS AND FINISHES TO BE REPAIRED AS REQUIRED TO MATCH EXISTING ADJACENT WALLS. F. GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO PATCH ALL CRACKS AND RESEAL JOINTS IN EXISTING SUBSTRATES SCHEDULED TO RECEIVE NEW FINISHES. G. UNLESS NOTED OTHERWISE, NEW WALLS TO BE 3 5/8" METAL STUDS @ 16" O.C. WITH (1) LAYER OF 5/8" TYPE "X" GYPSUM BOARD EACH SIDE. EXTEND STUD AND GYPSUM BOARD TO DECK ABOVE. SEAL AS REQUIRED FOR WALL RATINGS INDICATED ON THE CODE REVIEW PLAN. 2' - 4" 3' - 3" NOTE: WALL PARTITION DIMENSION STRINGS ARE FROM FACE OF STUD TO FACE OF STUD. 1.0 2.0 3.0 4.0 METAL STUD WOOD STUD CONCRETE MASONRY UNIT CAST-IN-PLACE CONCRETE 1.3a STRUCTURE/FRAMING NOMINAL DIMENSION TYPE DESIGNATION STRUCTURE/FRAMING RATING R X-RAY 108 CHANGE 126 CHANGE 125 E108 1.3A 1' - 6" 9.01 3.02 A-420 4 6.01 11.02 9.05 1.06 3.16 3.14 3.12 2.01 3.01 3.13 3.09 3.17                       DRAWING CONTENTS: ISSUE DATE: DRAWING NO. PROJECT NO. ST. VINCENT MICHIGAN ROAD HOPD IMAGING POS22 COMPLIANCE 10801 N MICHIGAN RD, ZIONSVILLE, IN 46077 MKM: ASCENSION: Certification: Key Plan: Consultant Logo: 119 West Wayne Street Fort Wayne, Indiana 46802 p 260.422.0783 f 260.426.4561 www.MKMdesign.com 30329            02/12/2018 17088 A-102         FIRST FLOOR DEMO & ARCHITECTURAL PLANS - XRAY DEMOLITION PLAN NOTES 3.07 REMOVE AND DISPOSE OF EXTERIOR WINDOW SYSTEM. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW WORK AS SCHEDULED. 3.08 REMOVE EXISTING CURTAIN (VALANCE) AND RELATED HANGERS ONLY IN THEIR ENTIRETY AND OFFER TO OWNER BEFORE DISPOSING. EXISTING BLINDS TO REMAIN. PROTECT DURING CONSTRUCTION. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED. 3.09 EXISTING INTERIOR WINDOW SYSTEM TO REMAIN. 3.10 REMOVE DOOR(S), HARDWARE, AND FRAME. OFFER DOOR(S) AND HARDWARE TO OWNER BEFORE DISPOSING. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW WORK AS SCHEDULED. 3.11 ELECTRICAL, PHONE OR NURSE CALL PANEL/CABINET. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. 3.12 EXISTING DOOR(S), HARDWARE, AND FRAME TO REMAIN. CLEAN/ PREP EXISTING FRAMES FOR NEW FINISH. PROTECT DURING CONSTRUCTION. REPAIR/REPLACE DAMAGED COMPONENTS AT CONCLUSION OF THE WORK. 3.13 REMOVE BASE CABINET(S), COUNTERTOP, WALL CABINET(S), MISCELLANEOUS TASKLIGHTING AND PLUMBING FIXTURES, WHERE APPLICIABLE. OFFER TO OWNER BEFORE DISPOSING. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED. 3.14 EXISTING CASEWORK TO REMAIN. PROTECT DURING CONSTRUCTION. 3.16 EXISTING FURNITURE TO BE REMOVED BY OFFICEWORK. EXISTING LARGE MEDICAL EQUIPMENT, INCLUDIING DEXA CAMERA TO BE REMOVED BY TRIMEDEX. 3.17 EXISTING PLUMBING FIXTURE(S) TO REMAIN. PROTECT DURING CONSTRUCTION. REPLACE DAMAGED FIXTURES AT CONCLUSION OF THE WORK. 3.18 REMOVE PLUMBING FIXTURE(S). OFFER TO OWNER BEFORE DISPOSING. SEE PLUMBING DRAWINGS FOR MORE INFROMATION. 3.19 REMOVE UPPER CABINET ONLY. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED. 3.20 REMOVE EXISTING WALL COVERING IN ITS ENTIRETY. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED. 3.21 REMOVE AND SALVAGE EXISTING WALL MOUNTED EQUIPMENT. 3.22 EXISTING WALL PROTECTION TO REMAIN. PROTECT DURING CONSTRUCTION. 3.23 DATA AND POWER RECEPTACLES TO BE REMOVED / RELOCATED. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED. SEE ELECTRICAL FOR ADDITIONAL INFORMATION. 3.24 MAIL BOX TO BE REMOVED AND SALVAGED BY OFFICEWORKS. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED. DEMOLITION PLAN NOTES CEILING DEMOLITION 1.01 REMOVE AND DISPOSE OF ACOUSTICAL LAY-IN CEILING SYSTEM: TILES, GRID AND ALL RELATED HANGERS AND SUPPORTS. 1.02 EXISTING ACOUSTICAL LAY-IN CEILING SYSTEM TO REMAIN. PROTECT DURING CONSTRUCTION. REPLACE DAMAGED CEILING AREAS (MATCH EXISTING) AT CONCLUSION OF THE WORK. 1.03 REMOVE AND DISPOSE OF DRYWALL/PLASTER CEILING AND ALL RELATE FRAMING, SUPPORTS AND ACCESS PANELS. 1.04 REMOVE EXISTING CEILING ACCESS DOOR. 1.06 REMOVE AND DISPOSE OF ACOUSTICAL LAY-IN CEILING SYSTEM: TILES,GRID AND ALL RELATED HANGERS AND SUPPORTS AND UNISTRAT SYSTEM. FLOORING DEMOLITION 2.01 REMOVE AND DISPOSE OF VINYL FLOORING (SHEET/VCT) AND ALL RELATED MASTIC/ADHESIVE. CLEAN/ PREP/ PATCH/ REPAIR SUBFLOOR TO ACCEPT NEW FLOORING AS SCHEDULED. SUBFLOOR NEEDS TO BE COMPLETELY LEVEL AND SMOOTH PRIOR TO INSTALLATION OF NEW FINISHES AS SCHEDULE 2.02 REMOVE AND DISPOSE OF CARPET AND ALL RELATED ADHESIVE. CLEAN/ PREP/ PATCH/ REPAIR SUBFLOOR TO ACCEPT NEW FLOORING AS SCHEDULED. SUBFLOOR NEEDS TO BE COMPLETELY LEVEL AND SMOOTH PRIOR TO INSTALLATION OF NEW FINISHES AS SCHEDULED. 2.03 EXISTING FLOOR FINISH TO REMAIN. PROTECT FLOORING DURING CONSTRUCTION. REPLACE DAMAGED FLOOR AREAS (MATCH EXISTING) AT CONCLUSION OF THE WORK. PARTITION DEMOLITION 3.01 REMOVE AND DISPOSE OF EXISTING WALL BASE. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED. 3.02 REMOVE AND SALVAGE PORTION OF EXISTING EXTERIOR MANSORY WALL SYSTEM ABOVE AND BELOW THE WINDOW AS REQUIRED AND PREPARE ADJACENT FOR NEW CONSTRUCTION. REMOVE PA CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW WORK AS SCHEDULED. 3.03 EXISTING TV TO BE REMOVED BY OWNER. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED. 3.04 FROM CORNER, REMOVE EXISTING WALL COVERING IN ITS ENTIRETY. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED. 3.05 REMOVE AND DISPOSE OF WALL PROTECTION - CORNER GUARD, RUBSTRIP OR WAINSCOT. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW FINISHES AS SCHEDULED. SKIM-COAT WALL TO ACCEPT NEW WALL FINISH AS SCHEDULED. 3.06 REMOVE PORTION OF EXISTING WALL AS REQUIRED. CLEAN/ PREP/ PATCH/ REPAIR WALL SURFACE TO ACCEPT NEW WORK AS SCHEDULED. FLOOR PLAN NOTES 9.02 INFILL EXISTING WALL OPENING - MATCH ADJACENT CONSTRUCTION. 9.04 MODIFY FRAMING FROM DEMOLISHED DARK ROOM DOOR AND PATCH FINISHES TO MATCH ADJACENT AS REQUIRED. 9.05 PAINT EXISTING DOOR FRAME IN ITS ENTIRETY. DIV 10 - SPECIALTIES 10.01 NEW 18" VERTICAL GRAB BAR TO MATCH EXISTING IN FINISH AND TEXTURE. DIV 11 - EQUIPMENT 11.01 FURNITURE SYSTEMS BY OFFICEWORKS. SEE VENDOR DRAWINGS FOR MORE INFORMATION. 11.02 XRAY EQUIMPEMT BY VENDOR. 11.03 RESINTALL SALVAGED WALL MOUNTED EQUIPMENT AT THE SAME AT AS PREVIOUSLY INSTALLED. DIV 22 - PLUMBING 22.01 STORM PIPE. SEE MECHANICAL DIV 32 – EXTERIOR IMPROVEMENTS 32.01 EXISTING SIDEWALK PROTECT DURING CONSTRUCTION 32.02 NEW SIDEWALK. SEE DETAILS ON SHEET A-202 AND SPECIFICATIONS FOR MORE INFORMATION 32.03 EXISTING UTILITY LIGHT POLE POWER LINE. IDENTIFY PRIOR TO EXCAVATION 32.04 EXISTING IRRIGATION LINE TO BE MODIFIED AS NEEDED. FLOOR PLAN NOTES DIV 3 - CONCRETE 3.01 ALIGN NEW CONCRETE SLAB EDGE WITH FINISH HEIGHT IN NEW VESTIBULE. SEE SECTIONS FOR MORE INFORMATION 3.02 LINE OF CONCRETE CLEARANCE FOR X-RAY EQUIPMENT. MANUFACTURER APPROVED THE EXISTING 4" CONCRETE SLAB FOR NEW X-RAY EQUIPMENT. CONTACTOR TO HAVE AN ALLOWANCE FOR NEW 8" CONCRETE SLAB IF EXISTING CONCRETE IS IN BAD CONDITION. DIV 4 - MASONRY 4.01 NEW COLUMN MASONRY UNITS, PRECAST CONCRETE ACCENTS AND MORTAR TO MATCH EXISTING BUILDING IN COLOR AND FINISH. NEW BRICK TO RUN 1/3 BOND PATTERN, SPLIT-FACE CMU TO RUN 1/2 BOND PATTERN. MORTAR TO BE LAB TESTED TO MATCH EXISTING. DIV 6 - WOOD, PLASTICS, AND LAMINATES 6.01 NEW LAMINATE COUNTERTOP. SEE DETAIL FOR MORE INFORMATION. 6.02 SALVAGED MAILBOX TO BE INSTALLED BY OFFICEWORK. DIV 7 - THERMAL PROTECTIODIV 7 - THERMAL MOISTURE PROTECTION 7.01 DOWNSPOUT. SEE MECHANICAL DIV 8 - OPENINGS 8.01 NEW ADA PUSH BUTTON. SEE ELECTRICAL FOR ADDITIONAL INFORMATION. DIV 9 - FINISHES 9.01 GYPSUM BOARD BULKHEAD. SEE REFLECTED CEILING AND FINISH PLANS FOR MORE INFORMATION. WALL TYPE SCHEDULE WALL TYPE RATING DESCRIPTION 1.3 3 5/8" METAL STUD @ 16" O.C. (1) LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE EXTEND TO 6" ABOVE ABOVE AND INSULATE FULL HEIGHT (TYPICAL WALL COMPOSITION). 1.3A 3 5/8" METAL STUD @ 16" O.C. (1) LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE EXTEND TO DECK ABOVE AND INSULATE FULL HEIGHT. 1/32" LEAD LINED TO A HEIGHT OF 7'-0". WALL TYPE LEGEND TYPICAL FRAMING DTL. 1/4" = 1'-0" 2 FIRST FLOOR ARCHITECTURAL PLAN 1/4" = 1'-0" 1 FIRST FLOOR DEMOLITION PLAN REVISION No. Date Revision 04/12/18 Nick Mishler 04/12/18 Nick Mishler