Loading...
HomeMy WebLinkAboutA-131 - FIRST FLOOR REFLECTED CEILINGTV REFLECTED CEILING PLAN GENERAL NOTES A. CONTRACTOR TO REVIEW REFLECTED CEILING PLANS WITH MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION SYSTEMS TO COORDINATE INSTALLATION AND NOTIFY ARCHITECT IMMEDIATELY IF ANY CONFLICTS OCCUR. B. CONTRACTOR TO SKETCH/SCRIBE ALL BULKHEADS ON THE FLOOR PRIOR TO CONSTRUCTION FOR FIELD COORDINATION. C. FIELD VERIFY ANY ACCESS PANELS WITHIN THE CEILINGS/ SOFFITS WITH ARCHITECT PRIOR TO INSTALLATION. SEE SPECIFICAITONS FOR ACCESS PANELS. D. REFER TO ENLARGED REFLECTED CEILING PLANS FOR SPECIFIC AREAS IF REQUIRED FOR THE PROJECT. E. IF PROJECT DOES NOT REQUIRE SPRAY-APPLIED FIREPROOFING, OPEN CEILINGS WITH EXPOSED STRUCTURAL STEEL SHALL BE PAINTED. REFER TO REFLECTED CEILING PLAN AND THE FINISH LEGEND FOR PAINT SELECTION. F. IF PROJECT REQUIRES SPRAY-APPLIED FIREPROOFING, OPEN CEILINGS TO EXPOSED STRUCTURAL STEEL ABOVE SHALL NOT BE PAINTED. SEE SPECIFICATIONS FOR MORE INFORMATION ON SPRAY-APPLIED FIREPROOFING G. FOR ADDITIONAL INFORMATION AND CEILING HEIGHT CLARIFICATION REFER TO THE INTERIOR ELEVATIONS. H. FOR BULKHEAD FINISH COLOR INFORMATION REFER TO FINISH LEGEND. ACP-1 - MATCH EXISTING MANUFACTURER: ARMSTRONG PRODUCT TYPE: HUMIGAURD PLUS PRODUCT NO.: 1774 SIZE: 24" X 24" X 1" COLOR/EDGE: MATCH EXISTING GRID SYSTEM: MATCH EXISTING CEILING HEIGHT A.F.F. S SPEAKER REFLECTED CEILING FINISH LEGEND GYP COLOR: PT-6 FINISH: FLAT UNLESS NOTED OTHERWISE X-RAY 108 BOTTOM FLANGE OF STEEL BAR JOISTS ABOVE AT 11'-0" (FIELD VERIFY) 2' - 1 1/2" 5' - 11" 5' - 11" 5' - 8 1/2" 5' - 9 1/8" 4 7/8" 6' - 0" 4 7/8" 7' - 1 1/8" 10' - 0" 8' - 9 1/2" 8' - 8" 2 7 6' - 9 3/4" 6' - 4 7/8" 6' - 0" 4 7/8" 9' - 2 3/8" 4 2 VESTIBULE WAITING 101 REG. 102 103A WORK AREA 103B PUBLIC TLT 104 OFFICE 105 3 SUB WAITING 106 A-131 1 Sim 2 OFFICE / CONSULT 112 3 3 3 3 7 8' - 0" 3 6 5 1 2 7' - 9 7/8" 3' - 4 1/4" 8' - 0" 8' - 6" 8' - 6 1/2" 2 MATCH EX. HEIGHT MATCH EX. HEIGHT 8' - 6" 3 2 MATCH EX. HEIGHT MATCH EX. HEIGHT 8' - 8" 5 8' - 0" 7 7 4 3 4 4 5 1/4" 8' - 0" 2' - 4" 8 3 4 2' - 4" 6" (MIN) METAL STUD DIAG. BRACING @ 48" O.C. METAL STUD FRAMING @ 16" O.C. LAY-IN CEILING TILE - SEE REF. CLG. PLAN 5/8" TYPE "X" GYPSUM BOARD                       DRAWING CONTENTS: ISSUE DATE: DRAWING NO. PROJECT NO. ST. VINCENT MICHIGAN ROAD HOPD IMAGING POS22 COMPLIANCE 10801 N MICHIGAN RD, ZIONSVILLE, IN 46077 MKM: ASCENSION: Certification: Key Plan: Consultant Logo: 119 West Wayne Street Fort Wayne, Indiana 46802 p 260.422.0783 f 260.426.4561 www.MKMdesign.com 30329             02/12/2018 17088 A-131         FIRST FLOOR REFLECTED CEILING REFLECTED CEILING PLAN NOTES 1 PROVIDE NEW LAY-IN CEILING SYSTEM AS SCHEDULED. ALIGN NEW GRID WITH EXISTING. 2 PROVIDE NEW LAY-IN CEILING SYSTEM AS SCHEDULED. MATCH EXISTING CEILING HEIGHT. 3 EXISTING LAY-IN CEILING TO REMAIN. PROTECT DURING CONSTRUCTION 4 SEE MEP FOR ADDITIONAL SCOPE OF WORK. 5 MODIFY EXISTING LAY-IN CEILING AS NEEDED FOR NEW CONSTRUCTION. 6 EXISTING BULKHEAD TO REMAIN. PROTECT DURING CONSTRUCTION. 7 PROVIDE NEW BULKHEAD SYSTEM. 8 PROVIDE 2" CONTINIUOUS ALUMINUM SOFFIT VENT 1/4" = 1'-0" 1 ENLARGED RCP - X-RAY RM. NORTH 1/8" = 1'-0" FIRST FLOOR REFLECTED CEILING PLAN 1" = 1'-0" 2 CEILING DTL. REVISION No. Date Revision 04/12/18 Nick Mishler 04/12/18 Nick Mishler