HomeMy WebLinkAboutA-131 - FIRST FLOOR REFLECTED CEILINGTV
REFLECTED CEILING PLAN GENERAL NOTES
A. CONTRACTOR TO REVIEW REFLECTED CEILING
PLANS WITH MECHANICAL, ELECTRICAL, PLUMBING, AND
FIRE PROTECTION SYSTEMS TO COORDINATE
INSTALLATION AND NOTIFY ARCHITECT IMMEDIATELY IF
ANY CONFLICTS OCCUR.
B. CONTRACTOR TO SKETCH/SCRIBE ALL BULKHEADS
ON THE FLOOR PRIOR TO CONSTRUCTION FOR FIELD
COORDINATION.
C. FIELD VERIFY ANY ACCESS PANELS WITHIN THE
CEILINGS/ SOFFITS WITH ARCHITECT PRIOR TO
INSTALLATION. SEE SPECIFICAITONS FOR ACCESS
PANELS.
D. REFER TO ENLARGED REFLECTED CEILING PLANS
FOR SPECIFIC AREAS IF REQUIRED FOR THE PROJECT.
E. IF PROJECT DOES NOT REQUIRE SPRAY-APPLIED
FIREPROOFING, OPEN CEILINGS WITH EXPOSED
STRUCTURAL STEEL SHALL BE PAINTED. REFER TO
REFLECTED CEILING PLAN AND THE FINISH LEGEND FOR
PAINT SELECTION.
F. IF PROJECT REQUIRES SPRAY-APPLIED
FIREPROOFING, OPEN CEILINGS TO EXPOSED
STRUCTURAL STEEL ABOVE SHALL NOT BE PAINTED.
SEE SPECIFICATIONS FOR MORE INFORMATION ON
SPRAY-APPLIED FIREPROOFING
G. FOR ADDITIONAL INFORMATION AND CEILING HEIGHT
CLARIFICATION REFER TO THE INTERIOR ELEVATIONS.
H. FOR BULKHEAD FINISH COLOR INFORMATION REFER
TO FINISH LEGEND.
ACP-1 - MATCH EXISTING
MANUFACTURER: ARMSTRONG
PRODUCT TYPE: HUMIGAURD PLUS
PRODUCT NO.: 1774
SIZE: 24" X 24" X 1"
COLOR/EDGE: MATCH EXISTING
GRID SYSTEM: MATCH EXISTING
CEILING HEIGHT A.F.F.
S SPEAKER
REFLECTED CEILING FINISH LEGEND
GYP
COLOR: PT-6
FINISH: FLAT
UNLESS NOTED OTHERWISE
X-RAY
108
BOTTOM FLANGE
OF STEEL BAR
JOISTS ABOVE AT
11'-0" (FIELD
VERIFY)
2' - 1 1/2" 5' - 11" 5' - 11" 5' - 8 1/2"
5' - 9 1/8" 4 7/8" 6' - 0" 4 7/8" 7' - 1 1/8"
10' - 0"
8' - 9 1/2"
8' - 8"
2
7
6' - 9 3/4"
6' - 4 7/8"
6' - 0" 4 7/8" 9' - 2 3/8"
4 2
VESTIBULE
WAITING 101
REG. 102
103A
WORK
AREA
103B
PUBLIC
TLT
104
OFFICE
105
3
SUB
WAITING
106 A-131
1 Sim
2
OFFICE /
CONSULT
112
3
3
3
3
7
8' - 0"
3
6
5
1
2
7' - 9 7/8" 3' - 4 1/4"
8' - 0"
8' - 6"
8' - 6 1/2" 2
MATCH EX.
HEIGHT
MATCH EX.
HEIGHT
8' - 6"
3
2
MATCH EX.
HEIGHT
MATCH EX.
HEIGHT
8' - 8"
5
8' - 0"
7
7
4
3
4
4
5 1/4" 8' - 0"
2' - 4"
8
3
4
2' - 4"
6" (MIN)
METAL STUD DIAG.
BRACING @ 48" O.C.
METAL STUD
FRAMING @ 16" O.C.
LAY-IN CEILING TILE -
SEE REF. CLG. PLAN
5/8" TYPE "X"
GYPSUM BOARD
DRAWING CONTENTS:
ISSUE DATE:
DRAWING NO.
PROJECT NO.
ST. VINCENT
MICHIGAN ROAD
HOPD
IMAGING POS22
COMPLIANCE
10801 N MICHIGAN RD,
ZIONSVILLE, IN 46077
MKM:
ASCENSION:
Certification:
Key Plan:
Consultant Logo:
119 West Wayne Street
Fort Wayne, Indiana 46802
p 260.422.0783
f 260.426.4561
www.MKMdesign.com
30329
02/12/2018 17088
A-131
FIRST FLOOR
REFLECTED CEILING
REFLECTED CEILING PLAN NOTES
1 PROVIDE NEW LAY-IN CEILING SYSTEM AS
SCHEDULED. ALIGN NEW GRID WITH EXISTING.
2 PROVIDE NEW LAY-IN CEILING SYSTEM AS
SCHEDULED. MATCH EXISTING CEILING HEIGHT.
3 EXISTING LAY-IN CEILING TO REMAIN. PROTECT
DURING CONSTRUCTION
4 SEE MEP FOR ADDITIONAL SCOPE OF WORK.
5 MODIFY EXISTING LAY-IN CEILING AS NEEDED FOR
NEW CONSTRUCTION.
6 EXISTING BULKHEAD TO REMAIN. PROTECT
DURING CONSTRUCTION.
7 PROVIDE NEW BULKHEAD SYSTEM.
8 PROVIDE 2" CONTINIUOUS ALUMINUM SOFFIT
VENT
1/4" = 1'-0"
1 ENLARGED RCP - X-RAY RM.
NORTH
1/8" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN
1" = 1'-0"
2 CEILING DTL.
REVISION
No. Date Revision
04/12/18
Nick Mishler
04/12/18
Nick Mishler