HomeMy WebLinkAboutA-141 - FIRST FLOOR FINISH PLANS
TABLE PARK
1
A
T
LF/30/42
T
T
T
TV
1
1
REG.
103A
WORK
AREA
103B
VESTIBULE
101
WAITING
102
CIRC
107
OFFICE
105
SUB
WAITING
106
PUBLIC
TLT
104
X-RAY
108
CIRC.
110
CIRC.
111
1
1
CIRC
115
CIRC
116
RECEPTION
109
CIRC
113
OFFICE /
CONSULT
112
A. SEE FINISH FLOOR PLAN AND STANDARD INTERIOR DETAILS FOR TRANSITION
LOCATIONS AND DETAILS.
B. ALL TRANSITIONS TO MEET ADA REQUIREMENTS. CONTRACTOR RESPONSIBLE
FOR FEATHERING FLOOR FOR FLUSH TRANSITION BETWEEN MATERIALS.
C. SEE FINISH FLOOR PLAN FOR FLOOR PATTERN AND INDICATION OF FLOORING
MATERIAL TRANSITIONS.
D. SEE REFLECTED CEILING PLAN FOR CEILING MATERIAL LIST, CEILING HEIGHTS,
BULKHEAD PAINT COLOR, AND CUBICLE CURTAINS.
E. SEE WINDOW ELEVATIONS FOR LOCATIONS OF SPECIALTY GLASS,
MECHOSHADES, AND INTERGRAL BINDS.
F. SEE WALL PROTECTION PLAN FOR LOCATIONS AND DETAILS.
G. SEE CASEWORK DRAWINGS FOR STANDARD WINDOW SILL DETAILS.
H. TERMINATE WALLCOVERING AT ALL INSIDE CORNERS.
I. FOR ADDITIONAL INFORMATION SEE INTERIOR ELEVATIONS, AND FOR CEILING
HEIGHTS SEE REFLECTED CEILING PLANS.
FINISH PLAN GENERAL NOTES
1. PAINT TO BE EPOXY.
2. CONFIRM ACCENT PAINT COLOR/LOCATION WITH OWNER.
FINISH SCHEDULE REMARKS:
SUMMARY
SECTION INCLUDES HETEROGENEOUS
RESILIENT SHEET PRODUCT WITH WELDED
SEAMS TO PROVIDE AN IMPERVIOUS FLOOR
SURFACE.
PERFORMANCE CRITERIA
MINIMUM WEAR LAYER THICKNESS: 0.020 IN.
MINIMUM OVERALL THICKNESS: 0.080 IN.
MINIMUM STATIC LOAD LIMIT: 750 PSI
MAINTENANCE PROPERTIES: TRUE NO-WAX
WELD: COLOR TO MATCH FLOORING
PRODUCT APPLICATION
THE NUMBER OF FLOORING MATERIALS,
PATTERNING, AND WELDED SEAMS WILL BE
MINIMAL. HERRINGBONE, RADIUSES, OR
COMPLEX FLOOR PATTERNS WILL NOT BE
USED.
PRE-INSTALLATION REQUIREMENTS
ALL NEW FLOORING MATERIALS, NOT
PREVIOUSLY INSTALLED IN EXISTING FACILITY
OR CAMPUS, WILL BE TESTED BY
MAINTENANCE AND ENVIRONMENTAL SERVICE
REPRESENTATIVE(S) PRIOR TO
SPECIFICATION.
SEAMING DIAGRAMS FOR RESILIENT SHEET
FLOORING WILL BE PROVIDED TO REDUCE
MATERIAL WASTE AND VERIFIED FOR
CONSTRUCTABILITY. SEAMING DIAGRAMS WILL
BE PROVIDED IN IMPLEMENTATION DRAWINGS.
WHEN SEAMLESS FLOORING IS UTILIZED AT
ON-GRADE OR BELOW GRADE LOCATIONS,
SPECIFICATIONS AND INSTALLATION
REQUIREMENTS WILL BE COST-EFFECTIVE
PROVEN STRATEGIES TO MITIGATE
UNNECESSARY COST. ALLOWANCES WILL NOT
BE ACCEPTED.
PROTECTION
FLOORING SHOULD BE PROTECTED DURING
DURATION OF CONSTRUCTION AND FF&E
INSTALLATION PHASES.
PRE-OCCUPANCY REQUIREMENTS
MANUFACTURER TECHNICIAN TO PROVIDE IN-
SERVICE MAINTENANCE TRAINING TO
TOUCHPOINT/EVS COVERING DAILY AND
MILESTONE CLEANING REQUIREMENTS.
TERMINAL CLEANING OF THE FLOORING WILL
BE CONDUCTED PRIOR TO OCCUPANCY.
CLEANING, MAINTENANCE AND WARRANTY
TEKNOFLOR:
HTTPS://WWW.SHANNONSPECIALTYFLOORS.C
OM/TECHNICAL-DATA/TEKNOFLOR/
MANNINGTON:
HTTPS://WWW.MANNINGTONCOMMERCIAL.CO
M/RESOURCES/TECHNICAL/
.
RESILIENT NO WAX SHEET: NO SUBSTITUTIONS
TEKNOFLOR CONTACT:
NAME: DALE CARSON
EMAIL:DALEC@SHANNONSPECIALTYFLOORS.COM
PHONE:407-414-7933
RS-1
MANUFACTURER: TEKNOFLOR FLOORING
PRODUCT TYPE: COASTALSCAPES HPD
PRODUCT NO.: 9301
SIZE: 6' ROLL
COLOR: COCONUT BARK
WELD: TEKWELD 9301
FINISH LEGEND - FLOORING - RESILIENT NO WAX SHEET
RESILIENT BASE: NO SUBSTITUTIONS
JOHNSONITE CONTACT:
NAME: BRENDA CICCARELLO
EMAIL: BRENDA.CICCARELLO@TARKETT.COM
PHONE: 440-321-2156
RB-1
MANUFACTURER: JOHNSONITE FLOORING
PRODUCT TYPE: TRADITIONAL COVE BASE
PRODUCT NO.: DC-29-4
SIZE: 4" HEIGHT
COLOR: MOONROCK 29
RB-2
NOT USED
RB-3
MANUFACTURER: JOHNSONITE FLOORING
PRODUCT TYPE: MANDALAY
PRODUCT NO.: MW-29-H
SIZE: 4.5" HEIGHT
COLOR: MOONROCK 29
FINISH LEGEND - BASE & ACCESSORIES
SUMMARY
SECTION INCLUDES RESILIENT BASE AND
STAIR TREADS.
DEFINITIONS
PUBLIC SPECIAL USE SHALL INCLUDE LOBBIES
AND OTHERS HIGH-VISIBILITY AREAS THAT
REQUIRE AND AESTHETIC UPGRADE.
PERFORMANCE CRITERIA
RESILIENT BASE
STYLE: COVED TOE
MATERIAL: VINYL OR RUBBER
LENGTH: CONTINUOUS ROLL
HEIGHT: 4" MINIMUM
STAIRTREAD
STYLE: ONE-PIECE NOSING-TREAD-RISER
STAIRTREAD
MATERIAL: RUBBER
ACCESSORY REQUIRED: VISUALLY IMPAIRED
STRIPS
PRODUCT APPLICATION
RESILIENT COVE BASE SHOULD BE USED AT
APPLICABLE CARPET AND RESILIENT
FLOORING APPLICATIONS.
PROTECTION
FLOORING SHOULD BE PROTECTED DURING
DURATION OF CONSTRUCTION AND FF&E
INSTALLATION PHASES.
CLEANING, MAINTENANCE AND WARRANTY
JOHNSONITE
HTTP://WWW.JOHNSONITE.COM/PORTALS/8/FIL
ES/MLDINS090806.PDF
NORA
HTTP://NORA.COM/FILEADMIN/USER_UPLOAD/
_TEMP_/PDF/US/MAINTENANCE_GUIDE/MAINTE
NANCE_STAIRTREADS_0117.PDF
SUMMARY
SECTION INCLUDES INTERIOR CARPET TILE
AND WALK-OFF CARPET TILE
PERFORMANCE CRITERIA
CARPET TILE
FIBER AND DYE METHOND: 100% SOLUSTION
DYED NYLON
CONSTRUCTION: LOOP OR CUT/LOOP
BACKING: HIGH PERFORMANCE BACKING, NO
CUSHION
INSTALLATION: DIRECT GLUE-DOWN -
RELEASABLE GLUE
PRODUCT APPLICATION
SLIP-RESISTANT FLOORING MATERIALS ARE
REQUIRED AT ALL ENTRANCE DOORS,
VESTIBULES , AND LOBBY AREAS, EXTENDING
A MINIMUM OF 10'-0" INTO THE BUILDING FROM
ENTRY.
PROTECTION
FLOORING SHOULD BE PROTECTED DURING
DURATION OF CONSTRUCTION AND FF&E
INSTALLATION PHASES.
PRE-OCCUPANCY REQUIREMENTS
MANUFACTURER TECHNICIAN TO PROVIDE IN-
SERVICE MAINTENANCE TRAINING TO
TOUCHPOINT/EVS COVERING DAILY AND
MILESTONE CLEANING REQUIREMENTS.
TERMINAL CLEANING OF THE FLOORING WILL
BE CONDUCTED PRIOR TO OCCUPANCY.
CLEANING AND MAINTENANCE
HTTP://WWW.MANNINGTONCOMMERCIAL.COM/
RESOURCES/TECHNICAL/
WARRANTY INFORMATION
HTTPS://MANNINGTONCOMMERCIAL.COM/RES
OURCES/TECHNICAL/
CARPET TILE-WALK-OFF: NO
SUBSTITUTIONS
CONTACT: STEVE HADRYCH
EMAIL: ASCENSION@MANNINGTON.COM
PHONE: 714-584-1902
WOC-1
MANUFACTURER: MANNINGTON
PRODUCT TYPE: RUFFIAN II
PRODUCT NO.: 8404
SIZE: 24" X 24"
COLOR: TAN TETONS
FINISH LEGEND - FLOORING - CARPET TILE
SUMMARY
SECTION INCLUDES LUXURY VINYL TILE
FLOORING (LVT).
PERFORMANCE CRITERIA
MINIMUM WEAR LAYER THICKNESS: 0.8 MM
MINIMUM OVERALL THICKNESS: 3.0 MM
MINIMUM STATIC LOAD LIMIT: 1000 PSI
MAINTENANCE PROPERTIES: TRUE NO-WAX
PRODUCT APPLICATION
REFER TO ROOM FINISH SCHEDULES FOR
APPLICATION GUIDANCE.
PRE-INSTALLATION REQUIREMENTS
ALL NEW FLOORING MATERIALS, NOT
PREVIOUSLY INSTALLED IN EXISTING FACILITY
OR CAMPUS, WILL BE TESTED BY
MAINTENANCE AND ENVIRONMENTAL SERVICE
REPRESENTATIVE(S) PRIOR TO
SPECIFICATION.
PROTECTION
FLOORING SHOULD DBE PROTECTED DURING
DURATION OF CONSTRUCTION AND FF&E
INSTALLATION PHASES.
PRE-OCCUPANCY REQUIREMENTS
MANUFACTURER TECHNICIAN TO PROVIDE IN-
SERVICE MAINTENANCE TRAINING TO
TOUCHPOINT/EVS COVERING DAILY AND
MILESTONE CLEANING REQUIREMENTS.
TERMINAL CLEANING OF THE FLOORING WILL
BE CONDUCTED PRIOR TO OCCUPANCY.
CLEANING AND MAINTENANCE
HTTPS://TANDUS-
PRODUCTION.S3.AMAZONAWS.COM/CONTENT/
FILE/207/LVT_RECOMMENDED_MAINTENANCE.
PDF
WARRANTY INFORMATION
HTTPS:TANDUS-
PRODUCTION.S3.AMAZONAWS.COM/CONTENT/
FILE/167/COMM_20YR_ECV.PDF
LUXURY VINYL TILE: NO SUBSTITUTIONS
CONTACT:
NAME: JENN HAUTAMAKI
EMAIL: JENN.HAITAMAKI@TARKETT.COM
PHONE: 313-330-1629
LVT-1
MANUFACTURER: TANDUS CENTIVA
PRODUCT TYPE: CLASSIC PLANK #ECK
PRODUCT NO.: 3307
SIZE: 6" X 36"
COLOR: EUROPEAN CHERRY
FINISH LEGEND - FLOORING - LUXURY VINYL TILE
WALL PROTECTION:
WALL PROTECTION: NO SUBSTITUTIONS
APPROVED DISTRIBUTOR
Name: Medxcel Customer Team
Email: Medxcel@Grainger.com
Phone Number: 1-888-693-3722
PRODUCT CONTACT
Name: Kimberly Bassett
Email: kbassett@inprocorp.com
Phone Number: 262-679-9010
WP-3
MANUFACTURER: INPRO
PRODUCT TYPE: 0.040" SHEET WALL PROTECTION
SIZE: 48" X 96"
COLOR: CLAM SHELL 0154
( PAINT COORDINATE:PT-3, PT-4 )
CORNER GUARDS:
CG-1
( ON ALL OUTSIDE CORNERS U.N.O. )
MANUFACTURER: INPRO
PRODUCT TYPE: 2" 90 DEGREE
PRODUCT NO: 160
SIZE: FULL HEIGHT
COLOR: TO MATCH SHEET WALL PROTECTION OR/
COLOR ACCORDING TO (PAINT
COORDINATE) LISTED IN WALL PROTECTION
DESCRIPTION IF NO WALL PROTECTION IS
SCHEDULED.
SUMMARY
SECTION INCLUDES SHEET WALL PROTECTION
AND CORNER GUARDS.
PERFORMANCE CRITERIA
RIGID SHEET WALL PROTECTION
MATERIAL: VINYL/ ACRYLIC OR PVC-FREE
THICKNESS: .040"
VERTICAL SEAMS: BUTT JOINTS WITH COLOR
MATCHED CAULK
FIRE RATING: CLASS A
PRODUCT APPLICATION
CHAIR RAIL WALL PROTECTION WILL BE
INSTALLED ON FURNITURE- LOCATED WALLS
IN ALL AREAS WHERE FURNITURE BACKS ARE
PLACED AGAINST A WALL. CHAIR RAILS MAY
BE OMITTED IF FURNITURE PROVIDES WALL
SAVER FEATURES AND FIXED BACKS.
PROTECTION
FLOORING SHOULD BE PROTECTED DURING
DURATION OF CONSTRUCTION AND FF&E
INSTALLATION PHASES.
DELIVERY/ STORAGE & HANDLING
PRODUCTS WILL BE DELIVER JUST IN TIME
USING PROCUREMENT PROCESS LISTED IN
PROCUMBENT SPECIFICATION.
CLEANING AND MAINTENANCE
https://easternus.azureedge.net/~/media/Inpro/TDM
%20Files/Documents/C/l/e/a/n/Cleanup%20Instructi
ons482Rev6pdf.ashx?modified=20161220090407
WARRANTY INFORMATION
https://easternus.azureedge.net/~/media/Inpro/TDM
%20Files/Documents/W/a/r/r/a/WarrantyIPC485REV
3pdf.ashx?modified=20160907010622
SUMMARY
INTERIOR WALL AND TRIM PAINT
DELIVERY, STORAGE, AND HANDLING
PRODUCT WILL BE PROCURED THROUGH
GRAINGER PURCHASING PROGRAM. REFER
TO FRONT-END SPECIFICATION, 00 0000 /02
PRODUCT APPLICATION
USE NO VOC FORMULA IN OCCUPIED SPACE.
USE LOW VOC FORMULA WHEN SPACE IS NOT
OCCUPIED.
PRIMER PAINT
PRO-HIDE GOLD INTERIOR PRIMER
LATEX PAINT
PRO-HIDE GOLD INTERIOR LATEX
STANDARD WALL FINISH: EGGSHELL, TWO
COATS
STANDARD TRIM FINISH: SEMI-GLOSS, TWO
COATS
PRIMER: ONE COAT
WATER-BASED EPOXY PAINT
TBD
STANDARD WALL FINISH: EGGSHELL, TWO
COATS
STANDARD TRIM FINISH: SEMI-GLOSS, TWO
COATS
PRIMER: ONE COAT
PRE-INSTALLATION REQUIREMENTS
SURFACES WILL BE CLEAN, DRY AND DULL.
CLEANING
PREPARATION AND GENERAL REQUIREMENTS.
MAINTENANCE
PREPARATION AND GENERAL REQUIREMENTS.
PAINT: NO SUBSTITUTIONS
APPROVED DISTRIBUTOR
NAME: MEDXCEL CUSTOMER TEAM
EMAIL: MEDXCEL@GRAINGER.COM
PHONE: 1-888-693-3722
PRODUCT CONTACT
NAME: VINCENT J. BARONE
EMAIL: VINCENT.J.BARONE@SHERWIN.COM
PHONE: 216-515-7785
PT-4
MANUFACTURER: PRATT & LAMBERT
COLOR: 32-28 CADET GRAY
PT-5
MANUFACTURER: PRATT & LAMBERT
COLOR: 29-21 DEPENDABLE
PT-6
MANUFACTURER: PRATT & LAMBERT
COLOR: 27-32 SEED PEARL
PT-B2
MANUFACTURER: PRATT & LAMBERT
COLOR: 26-12 PARADISE LOST
ALL CEILINGS TO BE PT-6
*ALL DOOR FRAMES TO BE PT-4
FINISH LEGEND - WALLS - PAINT
1
SEE CEILING PLANS
WALL BASE
GYP. BD. SEE
FINISH SCHEDULE
WALL PROTECTION
WP-3
CAP
DRAWING CONTENTS:
ISSUE DATE:
DRAWING NO.
PROJECT NO.
ST. VINCENT
MICHIGAN ROAD
HOPD
IMAGING POS22
COMPLIANCE
10801 N MICHIGAN RD,
ZIONSVILLE, IN 46077
MKM:
ASCENSION:
Certification:
Key Plan:
Consultant Logo:
119 West Wayne Street
Fort Wayne, Indiana 46802
p 260.422.0783
f 260.426.4561
www.MKMdesign.com
30329
02/12/2018 17088
A-141
FIRST FLOOR FINISH
PLANS
NORTH
1/8" = 1'-0"
FIRST FLOOR FINISH PLAN
FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR BASE
WALL
NORTH EAST SOUTH WEST REMARKS
LEVEL 1 - FIRST FLOOR
101 VESTIBULE WOC-1 RB-3 PT-4 PT-B2 PT-4 PT-4 2
102 WAITING LVT-1 RB-3 PT-4 PT-4 PT-4 ---
103A REG. LVT-1 RB-3 PT-4 --- PT-4 PT-4
103B WORK AREA LVT-1 RB-1 PT-4 PT-4 PT-4 PT-4
104 PUBLIC TLT --- --- --- --- --- --- 1
105 OFFICE LVT-1 RB-1 PT-4 PT-4 PT-5 PT-4
106 SUB WAITING LVT-1 RB-3 PT-4 PT-4 PT-4 PT-4
107 CIRC LVT-1 RB-3 PT-4 PT-4 --- PT-4
108 X-RAY RS-1 RB-1 PT-4 PT-4 PT-4 PT-4
109 RECEPTION --- --- --- --- --- ---
110 CIRC. LVT-1 RB-3 PT-4 PT-4 PT-4 PT-4
111 CIRC. LVT-1 RB-3 PT-4 PT-4 PT-4 PT-4
112 OFFICE /
CONSULT
LVT-1 RB-1 PT-4 PT-5 PT-4 PT-4
113 CIRC --- RB-1 --- --- PT-4 PT-4
115 CIRC LVT-1 RB-3 PT-4 PT-4 PT-4 PT-4
116 CIRC LVT-1 RB-3 PT-4 PT-4 PT-4 PT-4
REVISION
No. Date Revision
04/12/18
Nick Mishler
04/12/18
Nick Mishler