Loading...
HomeMy WebLinkAboutA-141 - FIRST FLOOR FINISH PLANS                 TABLE PARK 1 A T LF/30/42 T T T TV 1 1 REG. 103A WORK AREA 103B VESTIBULE 101 WAITING 102 CIRC 107 OFFICE 105 SUB WAITING 106 PUBLIC TLT 104 X-RAY 108 CIRC. 110 CIRC. 111 1 1 CIRC 115 CIRC 116 RECEPTION 109 CIRC 113 OFFICE / CONSULT 112 A. SEE FINISH FLOOR PLAN AND STANDARD INTERIOR DETAILS FOR TRANSITION LOCATIONS AND DETAILS. B. ALL TRANSITIONS TO MEET ADA REQUIREMENTS. CONTRACTOR RESPONSIBLE FOR FEATHERING FLOOR FOR FLUSH TRANSITION BETWEEN MATERIALS. C. SEE FINISH FLOOR PLAN FOR FLOOR PATTERN AND INDICATION OF FLOORING MATERIAL TRANSITIONS. D. SEE REFLECTED CEILING PLAN FOR CEILING MATERIAL LIST, CEILING HEIGHTS, BULKHEAD PAINT COLOR, AND CUBICLE CURTAINS. E. SEE WINDOW ELEVATIONS FOR LOCATIONS OF SPECIALTY GLASS, MECHOSHADES, AND INTERGRAL BINDS. F. SEE WALL PROTECTION PLAN FOR LOCATIONS AND DETAILS. G. SEE CASEWORK DRAWINGS FOR STANDARD WINDOW SILL DETAILS. H. TERMINATE WALLCOVERING AT ALL INSIDE CORNERS. I. FOR ADDITIONAL INFORMATION SEE INTERIOR ELEVATIONS, AND FOR CEILING HEIGHTS SEE REFLECTED CEILING PLANS. FINISH PLAN GENERAL NOTES 1. PAINT TO BE EPOXY. 2. CONFIRM ACCENT PAINT COLOR/LOCATION WITH OWNER. FINISH SCHEDULE REMARKS: SUMMARY SECTION INCLUDES HETEROGENEOUS RESILIENT SHEET PRODUCT WITH WELDED SEAMS TO PROVIDE AN IMPERVIOUS FLOOR SURFACE. PERFORMANCE CRITERIA MINIMUM WEAR LAYER THICKNESS: 0.020 IN. MINIMUM OVERALL THICKNESS: 0.080 IN. MINIMUM STATIC LOAD LIMIT: 750 PSI MAINTENANCE PROPERTIES: TRUE NO-WAX WELD: COLOR TO MATCH FLOORING PRODUCT APPLICATION THE NUMBER OF FLOORING MATERIALS, PATTERNING, AND WELDED SEAMS WILL BE MINIMAL. HERRINGBONE, RADIUSES, OR COMPLEX FLOOR PATTERNS WILL NOT BE USED. PRE-INSTALLATION REQUIREMENTS ALL NEW FLOORING MATERIALS, NOT PREVIOUSLY INSTALLED IN EXISTING FACILITY OR CAMPUS, WILL BE TESTED BY MAINTENANCE AND ENVIRONMENTAL SERVICE REPRESENTATIVE(S) PRIOR TO SPECIFICATION. SEAMING DIAGRAMS FOR RESILIENT SHEET FLOORING WILL BE PROVIDED TO REDUCE MATERIAL WASTE AND VERIFIED FOR CONSTRUCTABILITY. SEAMING DIAGRAMS WILL BE PROVIDED IN IMPLEMENTATION DRAWINGS. WHEN SEAMLESS FLOORING IS UTILIZED AT ON-GRADE OR BELOW GRADE LOCATIONS, SPECIFICATIONS AND INSTALLATION REQUIREMENTS WILL BE COST-EFFECTIVE PROVEN STRATEGIES TO MITIGATE UNNECESSARY COST. ALLOWANCES WILL NOT BE ACCEPTED. PROTECTION FLOORING SHOULD BE PROTECTED DURING DURATION OF CONSTRUCTION AND FF&E INSTALLATION PHASES. PRE-OCCUPANCY REQUIREMENTS MANUFACTURER TECHNICIAN TO PROVIDE IN- SERVICE MAINTENANCE TRAINING TO TOUCHPOINT/EVS COVERING DAILY AND MILESTONE CLEANING REQUIREMENTS. TERMINAL CLEANING OF THE FLOORING WILL BE CONDUCTED PRIOR TO OCCUPANCY. CLEANING, MAINTENANCE AND WARRANTY TEKNOFLOR: HTTPS://WWW.SHANNONSPECIALTYFLOORS.C OM/TECHNICAL-DATA/TEKNOFLOR/ MANNINGTON: HTTPS://WWW.MANNINGTONCOMMERCIAL.CO M/RESOURCES/TECHNICAL/ . RESILIENT NO WAX SHEET: NO SUBSTITUTIONS TEKNOFLOR CONTACT: NAME: DALE CARSON EMAIL:DALEC@SHANNONSPECIALTYFLOORS.COM PHONE:407-414-7933 RS-1 MANUFACTURER: TEKNOFLOR FLOORING PRODUCT TYPE: COASTALSCAPES HPD PRODUCT NO.: 9301 SIZE: 6' ROLL COLOR: COCONUT BARK WELD: TEKWELD 9301 FINISH LEGEND - FLOORING - RESILIENT NO WAX SHEET RESILIENT BASE: NO SUBSTITUTIONS JOHNSONITE CONTACT: NAME: BRENDA CICCARELLO EMAIL: BRENDA.CICCARELLO@TARKETT.COM PHONE: 440-321-2156 RB-1 MANUFACTURER: JOHNSONITE FLOORING PRODUCT TYPE: TRADITIONAL COVE BASE PRODUCT NO.: DC-29-4 SIZE: 4" HEIGHT COLOR: MOONROCK 29 RB-2 NOT USED RB-3 MANUFACTURER: JOHNSONITE FLOORING PRODUCT TYPE: MANDALAY PRODUCT NO.: MW-29-H SIZE: 4.5" HEIGHT COLOR: MOONROCK 29 FINISH LEGEND - BASE & ACCESSORIES SUMMARY SECTION INCLUDES RESILIENT BASE AND STAIR TREADS. DEFINITIONS PUBLIC SPECIAL USE SHALL INCLUDE LOBBIES AND OTHERS HIGH-VISIBILITY AREAS THAT REQUIRE AND AESTHETIC UPGRADE. PERFORMANCE CRITERIA RESILIENT BASE STYLE: COVED TOE MATERIAL: VINYL OR RUBBER LENGTH: CONTINUOUS ROLL HEIGHT: 4" MINIMUM STAIRTREAD STYLE: ONE-PIECE NOSING-TREAD-RISER STAIRTREAD MATERIAL: RUBBER ACCESSORY REQUIRED: VISUALLY IMPAIRED STRIPS PRODUCT APPLICATION RESILIENT COVE BASE SHOULD BE USED AT APPLICABLE CARPET AND RESILIENT FLOORING APPLICATIONS. PROTECTION FLOORING SHOULD BE PROTECTED DURING DURATION OF CONSTRUCTION AND FF&E INSTALLATION PHASES. CLEANING, MAINTENANCE AND WARRANTY JOHNSONITE HTTP://WWW.JOHNSONITE.COM/PORTALS/8/FIL ES/MLDINS090806.PDF NORA HTTP://NORA.COM/FILEADMIN/USER_UPLOAD/ _TEMP_/PDF/US/MAINTENANCE_GUIDE/MAINTE NANCE_STAIRTREADS_0117.PDF SUMMARY SECTION INCLUDES INTERIOR CARPET TILE AND WALK-OFF CARPET TILE PERFORMANCE CRITERIA CARPET TILE FIBER AND DYE METHOND: 100% SOLUSTION DYED NYLON CONSTRUCTION: LOOP OR CUT/LOOP BACKING: HIGH PERFORMANCE BACKING, NO CUSHION INSTALLATION: DIRECT GLUE-DOWN - RELEASABLE GLUE PRODUCT APPLICATION SLIP-RESISTANT FLOORING MATERIALS ARE REQUIRED AT ALL ENTRANCE DOORS, VESTIBULES , AND LOBBY AREAS, EXTENDING A MINIMUM OF 10'-0" INTO THE BUILDING FROM ENTRY. PROTECTION FLOORING SHOULD BE PROTECTED DURING DURATION OF CONSTRUCTION AND FF&E INSTALLATION PHASES. PRE-OCCUPANCY REQUIREMENTS MANUFACTURER TECHNICIAN TO PROVIDE IN- SERVICE MAINTENANCE TRAINING TO TOUCHPOINT/EVS COVERING DAILY AND MILESTONE CLEANING REQUIREMENTS. TERMINAL CLEANING OF THE FLOORING WILL BE CONDUCTED PRIOR TO OCCUPANCY. CLEANING AND MAINTENANCE HTTP://WWW.MANNINGTONCOMMERCIAL.COM/ RESOURCES/TECHNICAL/ WARRANTY INFORMATION HTTPS://MANNINGTONCOMMERCIAL.COM/RES OURCES/TECHNICAL/ CARPET TILE-WALK-OFF: NO SUBSTITUTIONS CONTACT: STEVE HADRYCH EMAIL: ASCENSION@MANNINGTON.COM PHONE: 714-584-1902 WOC-1 MANUFACTURER: MANNINGTON PRODUCT TYPE: RUFFIAN II PRODUCT NO.: 8404 SIZE: 24" X 24" COLOR: TAN TETONS FINISH LEGEND - FLOORING - CARPET TILE SUMMARY SECTION INCLUDES LUXURY VINYL TILE FLOORING (LVT). PERFORMANCE CRITERIA MINIMUM WEAR LAYER THICKNESS: 0.8 MM MINIMUM OVERALL THICKNESS: 3.0 MM MINIMUM STATIC LOAD LIMIT: 1000 PSI MAINTENANCE PROPERTIES: TRUE NO-WAX PRODUCT APPLICATION REFER TO ROOM FINISH SCHEDULES FOR APPLICATION GUIDANCE. PRE-INSTALLATION REQUIREMENTS ALL NEW FLOORING MATERIALS, NOT PREVIOUSLY INSTALLED IN EXISTING FACILITY OR CAMPUS, WILL BE TESTED BY MAINTENANCE AND ENVIRONMENTAL SERVICE REPRESENTATIVE(S) PRIOR TO SPECIFICATION. PROTECTION FLOORING SHOULD DBE PROTECTED DURING DURATION OF CONSTRUCTION AND FF&E INSTALLATION PHASES. PRE-OCCUPANCY REQUIREMENTS MANUFACTURER TECHNICIAN TO PROVIDE IN- SERVICE MAINTENANCE TRAINING TO TOUCHPOINT/EVS COVERING DAILY AND MILESTONE CLEANING REQUIREMENTS. TERMINAL CLEANING OF THE FLOORING WILL BE CONDUCTED PRIOR TO OCCUPANCY. CLEANING AND MAINTENANCE HTTPS://TANDUS- PRODUCTION.S3.AMAZONAWS.COM/CONTENT/ FILE/207/LVT_RECOMMENDED_MAINTENANCE. PDF WARRANTY INFORMATION HTTPS:TANDUS- PRODUCTION.S3.AMAZONAWS.COM/CONTENT/ FILE/167/COMM_20YR_ECV.PDF LUXURY VINYL TILE: NO SUBSTITUTIONS CONTACT: NAME: JENN HAUTAMAKI EMAIL: JENN.HAITAMAKI@TARKETT.COM PHONE: 313-330-1629 LVT-1 MANUFACTURER: TANDUS CENTIVA PRODUCT TYPE: CLASSIC PLANK #ECK PRODUCT NO.: 3307 SIZE: 6" X 36" COLOR: EUROPEAN CHERRY FINISH LEGEND - FLOORING - LUXURY VINYL TILE WALL PROTECTION: WALL PROTECTION: NO SUBSTITUTIONS APPROVED DISTRIBUTOR Name: Medxcel Customer Team Email: Medxcel@Grainger.com Phone Number: 1-888-693-3722 PRODUCT CONTACT Name: Kimberly Bassett Email: kbassett@inprocorp.com Phone Number: 262-679-9010 WP-3 MANUFACTURER: INPRO PRODUCT TYPE: 0.040" SHEET WALL PROTECTION SIZE: 48" X 96" COLOR: CLAM SHELL 0154 ( PAINT COORDINATE:PT-3, PT-4 ) CORNER GUARDS: CG-1 ( ON ALL OUTSIDE CORNERS U.N.O. ) MANUFACTURER: INPRO PRODUCT TYPE: 2" 90 DEGREE PRODUCT NO: 160 SIZE: FULL HEIGHT COLOR: TO MATCH SHEET WALL PROTECTION OR/ COLOR ACCORDING TO (PAINT COORDINATE) LISTED IN WALL PROTECTION DESCRIPTION IF NO WALL PROTECTION IS SCHEDULED. SUMMARY SECTION INCLUDES SHEET WALL PROTECTION AND CORNER GUARDS. PERFORMANCE CRITERIA RIGID SHEET WALL PROTECTION MATERIAL: VINYL/ ACRYLIC OR PVC-FREE THICKNESS: .040" VERTICAL SEAMS: BUTT JOINTS WITH COLOR MATCHED CAULK FIRE RATING: CLASS A PRODUCT APPLICATION CHAIR RAIL WALL PROTECTION WILL BE INSTALLED ON FURNITURE- LOCATED WALLS IN ALL AREAS WHERE FURNITURE BACKS ARE PLACED AGAINST A WALL. CHAIR RAILS MAY BE OMITTED IF FURNITURE PROVIDES WALL SAVER FEATURES AND FIXED BACKS. PROTECTION FLOORING SHOULD BE PROTECTED DURING DURATION OF CONSTRUCTION AND FF&E INSTALLATION PHASES. DELIVERY/ STORAGE & HANDLING PRODUCTS WILL BE DELIVER JUST IN TIME USING PROCUREMENT PROCESS LISTED IN PROCUMBENT SPECIFICATION. CLEANING AND MAINTENANCE https://easternus.azureedge.net/~/media/Inpro/TDM %20Files/Documents/C/l/e/a/n/Cleanup%20Instructi ons482Rev6pdf.ashx?modified=20161220090407 WARRANTY INFORMATION https://easternus.azureedge.net/~/media/Inpro/TDM %20Files/Documents/W/a/r/r/a/WarrantyIPC485REV 3pdf.ashx?modified=20160907010622 SUMMARY INTERIOR WALL AND TRIM PAINT DELIVERY, STORAGE, AND HANDLING PRODUCT WILL BE PROCURED THROUGH GRAINGER PURCHASING PROGRAM. REFER TO FRONT-END SPECIFICATION, 00 0000 /02 PRODUCT APPLICATION USE NO VOC FORMULA IN OCCUPIED SPACE. USE LOW VOC FORMULA WHEN SPACE IS NOT OCCUPIED. PRIMER PAINT PRO-HIDE GOLD INTERIOR PRIMER LATEX PAINT PRO-HIDE GOLD INTERIOR LATEX STANDARD WALL FINISH: EGGSHELL, TWO COATS STANDARD TRIM FINISH: SEMI-GLOSS, TWO COATS PRIMER: ONE COAT WATER-BASED EPOXY PAINT TBD STANDARD WALL FINISH: EGGSHELL, TWO COATS STANDARD TRIM FINISH: SEMI-GLOSS, TWO COATS PRIMER: ONE COAT PRE-INSTALLATION REQUIREMENTS SURFACES WILL BE CLEAN, DRY AND DULL. CLEANING PREPARATION AND GENERAL REQUIREMENTS. MAINTENANCE PREPARATION AND GENERAL REQUIREMENTS. PAINT: NO SUBSTITUTIONS APPROVED DISTRIBUTOR NAME: MEDXCEL CUSTOMER TEAM EMAIL: MEDXCEL@GRAINGER.COM PHONE: 1-888-693-3722 PRODUCT CONTACT NAME: VINCENT J. BARONE EMAIL: VINCENT.J.BARONE@SHERWIN.COM PHONE: 216-515-7785 PT-4 MANUFACTURER: PRATT & LAMBERT COLOR: 32-28 CADET GRAY PT-5 MANUFACTURER: PRATT & LAMBERT COLOR: 29-21 DEPENDABLE PT-6 MANUFACTURER: PRATT & LAMBERT COLOR: 27-32 SEED PEARL PT-B2 MANUFACTURER: PRATT & LAMBERT COLOR: 26-12 PARADISE LOST ALL CEILINGS TO BE PT-6 *ALL DOOR FRAMES TO BE PT-4 FINISH LEGEND - WALLS - PAINT 1 SEE CEILING PLANS WALL BASE GYP. BD. SEE FINISH SCHEDULE WALL PROTECTION WP-3 CAP                       DRAWING CONTENTS: ISSUE DATE: DRAWING NO. PROJECT NO. ST. VINCENT MICHIGAN ROAD HOPD IMAGING POS22 COMPLIANCE 10801 N MICHIGAN RD, ZIONSVILLE, IN 46077 MKM: ASCENSION: Certification: Key Plan: Consultant Logo: 119 West Wayne Street Fort Wayne, Indiana 46802 p 260.422.0783 f 260.426.4561 www.MKMdesign.com 30329              02/12/2018 17088 A-141         FIRST FLOOR FINISH PLANS NORTH 1/8" = 1'-0" FIRST FLOOR FINISH PLAN FINISH SCHEDULE ROOM NUMBER ROOM NAME FLOOR BASE WALL NORTH EAST SOUTH WEST REMARKS LEVEL 1 - FIRST FLOOR 101 VESTIBULE WOC-1 RB-3 PT-4 PT-B2 PT-4 PT-4 2 102 WAITING LVT-1 RB-3 PT-4 PT-4 PT-4 --- 103A REG. LVT-1 RB-3 PT-4 --- PT-4 PT-4 103B WORK AREA LVT-1 RB-1 PT-4 PT-4 PT-4 PT-4 104 PUBLIC TLT --- --- --- --- --- --- 1 105 OFFICE LVT-1 RB-1 PT-4 PT-4 PT-5 PT-4 106 SUB WAITING LVT-1 RB-3 PT-4 PT-4 PT-4 PT-4 107 CIRC LVT-1 RB-3 PT-4 PT-4 --- PT-4 108 X-RAY RS-1 RB-1 PT-4 PT-4 PT-4 PT-4 109 RECEPTION --- --- --- --- --- --- 110 CIRC. LVT-1 RB-3 PT-4 PT-4 PT-4 PT-4 111 CIRC. LVT-1 RB-3 PT-4 PT-4 PT-4 PT-4 112 OFFICE / CONSULT LVT-1 RB-1 PT-4 PT-5 PT-4 PT-4 113 CIRC --- RB-1 --- --- PT-4 PT-4 115 CIRC LVT-1 RB-3 PT-4 PT-4 PT-4 PT-4 116 CIRC LVT-1 RB-3 PT-4 PT-4 PT-4 PT-4 REVISION No. Date Revision 04/12/18 Nick Mishler 04/12/18 Nick Mishler