Loading...
HomeMy WebLinkAboutA-420 - CASEWORK NOTES, LEGEND, & DETAILSA. ALL CASEWORK SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS UNLESS NOTED OTHERWISE B. ALL WALL CABINETS SHALL BE 15" (INCHES) DEEP. (U.N.O) C. ALL WALL CABINETS WITH TASKLIGHT LOCATIONS SHALL HAVE A CASEWORK VALANCE THAT IS CONTINUOUS ACROSS ALL ADJOINING CABINETS. (U.N.O) D. ALL BASE CABINETS SHALL BE 24" (INCHES) DEEP. (U.N.O) E. ALL BASE CABINETS FOR VERTICAL FILE DRAWERS: INTERIOR DIMENSIONS MUST ACCOMMODATE FRONT TO BACK HANGING AND HAVE LOCK. (U.N.O) F. ON ALL BASE CABINETS, PROVIDE SCHEDULED WALL BASE ALONG BOTTOM OF EXPOSED FRONTS, BACKS, SIDES AND ENDS OF ALL FIXED CASEWORK, WARDROBES, END PANELS, VERTICAL SUPPORTS, KNEE SPACES, ETC. (U.N.O.) G. ALL INDIVIDUAL WALL CABINET WIDTHS SHALL BE ALIGNED WITH INDIVIDUAL BASE CABINET WIDTHS BELOW. (U.N.O.) H. ALL WALL AND BASE CABINETS LOCATED NEXT TO A SIDE WALL, PROVIDE A MINIMUM OF A 1" FILLER PANEL AT EACH END OF UPPER/LOWER CASEWORK. (U.N.O) I. ALL WALL CABINETS WITH A GYPSUM BOARD BULKHEAD ABOVE SHALL HAVE A MINIMUM OF A 1" FILL PANEL ACROSS THE TOP OF THE WALL CABINETS TO ALLOW FOR CLEAR DOOR SWING. J. ALL EXPOSED CABINET SIDES SHALL RECEIVE FINISHED END PANELS. (U.N.O) K. ALL CABINET DOOR WIDTHS SHALL NOT EXCEED 2'-0" IN WIDTH. (U.N.O) L. ALL CABINET DOOR AND DRAWER EDGES TO RECEIVE A 3MM EDGE BANDING. (U.N.O.) M. ALL HINGES AND RELATED HARDWARE SHALL BE CONCEALED. (U.N.O) N. ALL CABINETS AND DRAWERS TO INCLUDE 4" WIRE PULLS. (U.N.O) O. ALL COUNTERTOPS SHALL EXTEND 1" BEYOND THE DEPTH OF THE BASE CABINETS BELOW. (U.N.O) P. ALL COUNTERTOPS WITH EXPOSED OUTSIDE CORNERS SHALL HAVE A RADIUS CORNER. (U.N.O) Q. ALL PLASTIC LAMINATE COUNTERTOP FRONT EDGES/ EXPOSED EDGES SHALL HAVE 3MM EDGE (NOT NECESSARY ON BACKSPLASH OR SIDESPLASH). (U.N.O) R. ALL COUNTERTOPS SHALL BE INSTALLED AT 34" A.F.F. IF CONTAINING AND INTEGRAL BOWL SINK. (U.N.O) S. ALL DROP-IN SINKS IN COUNTERTOPS SHALL BE INSTALLED SO THAT THE RIM OF THE SINK IS AT 34" A.F.F. DO NOT INSTALL ANY LOWER TO AVOID CONFLICTS WITH OWNER SUPPLIED EQUIPMENT UNDER THE COUNTERTOP. (U.N.O) T. SHELVING UP TO 30" (INCHES) WIDE SHALL BE 3/4" THICK AND ADJUSTABLE, AND SHELVING OVER 30" (INCHES) WIDE SHALL BE 1" THICK AND HAVE INTERMEDIATE ADJUSTABLE SUPPORTS ALONG THE INSIDE BACK OF CABINET. (U.N.O) U. CASEWORK SHALL BE CAULKED AT ALL JUNCTURES WITH ADJOINING MATERIALS INCLUDING WALL, BASE, COUNTERTOP, ETC. EVEN THOUGH JOINT MAY NOT BE VISIBLE. V. ALL CASEWORK DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO SUBMITTING SHOP DRAWINGS/SHOP FABRICATION. DO NOT SCALE DRAWINGS. W. THE CONTRACTOR SHALL PROVIDE SOLID BLOCKING AS REQUIRED FOR WALL-MOUNTED CASEWORK AND ACCESSORIES. X. COORDINATE OWNER SUPPLIED WALL ACCESSORIES PRIOR TO INSTALLATION OF CASEWORK. Y. CASEWORK MANUFACTURER AND INSTALLER SHALL COORDINATE WITH APPROPRIATE SUBCONTRACTORS FOR INSTALLATION OF SINKS WITH ASSOCIATED PIPING AND FITTINGS, AND FOR INSTALLATION OF ELECTRICAL RECEPTACLES, LIGHT FIXTURES, VOICE/DATA OUTLETS, DICTATION OUTLETS, ETC. WITHIN THE CASEWORK. Z. THE CONTRACTOR SHALL VERIFY AND COORDINATE WITH THE OWNER IN CLEAR DIMENSION CONFLICTS BETWEEN THE PROPOSED EQUIPMENT SUPPLIED BY THE OWNER AND THE CASEWORK FOUND WITHIN THE CONSTRUCTION DOCUMENTS AND SHALL REPORT AT ONCE TO THE ARCHITECT ANY ERROR, INCONSISTENCY, OR OMISSION THAT HE MAY DISCOVER DURING THIS COORDINATION. CASEWORK GENERAL NOTES PLASTIC LAMINATE: PL-5 (COUNTERTOPS) MANUFACTURER: WILSONART PRODUCT NO.: 4943 COLOR: CLASSIC LINEN CASEWORK FINISH LEGEND 3/4" 3/4" VARIES KNEE SPACE VARIES 3/4" 3/4" VARIES BASE CABINET VARIES 4" PROVIDE PAINTED FIRE RETARDENT PLYWOOD AT ALL KNEE SPACES PROVIDE PAINTED FIRE RETARDENT WOOD BLOCKING FOR COUNTERTOP LEDGER WHERE STEEL ANGLE BRACKETS AREN'T REQUIRED PLASTIC LAMINATE COUNTER - SEE CASEWORK GENERAL NOTES FOR COUNTER EDGE PROFILE SEALANT JOINT AT TRANSITION SEE FINISH LEGEND/ELEVATIONS FOR BACKSPLASH/SIDESPLASH IF REQUIRED SEALANT JOINT AT WALL AND COUNTER OR BACKSPLASH PROVIDE FIRE RETARDENT PLYWOOD AT ALL BASE CABINETS PROVIDE FIRE RETARDENT WOOD BLOCKING AS NEEDED TO INSTALL COUNTERTOP AT BASE CABINETS PLASTIC LAMINATE COUNTER - SEE CASEWORK GENERAL NOTES FOR COUNTER EDGE PROFILE SEALANT JOINT AT BASE CABINET EDGE SEE FINISH LEGEND/ELEVATIONS FOR BACKSPLASH/SIDESPLASH IF REQUIRED SEALANT JOINT AT WALL AND COUNTER OR BACKSPLASH NOTE: PAINT AND SEAL ALL EXPOSED PLYWOOD SURFACES BELOW COUNTERS NOTE: PAINT AND SEAL ALL EXPOSED PLYWOOD SURFACES BELOW COUNTERS 3MM TRIM END PIECE. NOTE: PROVIDE EDGE BAND AT BASE AND WALL CABINET DOORS/ DRAWERS AND AT COUNTERTOP EDGES. (3) 2X4 FIRE RETARDANT WD BLOCKING IN STUD WALL - SPACE EQUALLY 2" X 2" X 1/4" VERT. LEG STEEL ANGLE RADIUS END OF STEEL ANGLE PAINT EXPOSED SURFACES SEE WALL TYPES SEE FINISH LEGEND FOR COUNTERTOP FINISH 4" PROVIDE SEALANT AT DRYWALL AROUND STEEL ANGLE AND ALONG PLYWOOD AT ANGLE FLANGE NOTE: THIS IS THE TYPICAL SUPPORT DETAIL FOR WALL MOUNTED COUNTER TOPS. STEEL ANGLE SUPPORTS SHALL NOT EXCEED A MAXIMUM SPACING OF 4'-0" (ANGLE VERTICAL LEG) 1' - 11 1/4" 2" X 2" X 1/4" HORIZ. LEG STEEL ANGLE SEE FINISH LEGEND FOR COUNTERTOP FINISH 4" PAINT FIRE RETARDANT WOOD LEDGER BEYOND TO SUPPORT COUNTERTOP AT END WALL. PROVIDE SEALANT ALONG PLYWOOD AND LEDGER COUNTER SUPPORT AT KNEE SPACE COUNTER SUPPORT AT END WALL SEE WALL TYPES CONTINUOUS WOOD LEDGER ALONG WALL WOOD BLOCKING IN WALL NOTE: THE FIRST STEEL ANGLE INSTALLED FOR THE PROJECT MUST HAVE ARCHITECT REVIEW QUALITY OF INSTALLATION PRIOR TO CLOSING-UP WALL. IF A DIFFERENT ANGLE OR MANUFACTURER OF ANGEL IS BEING PROVIDED. ANGLE SUBMITTALS AND SHOP DRAWINGS MUST BE SUBMITTED FOR REVIEW PRIOR TO PURCHASE OR FABRICATION ALONG WITH A MOCK-UP TO REVIEW. PAINT FIRE-RETARDANT PLYWOOD SUPPORT NOTE: AN APPROVED EQUAL TO THE STEEL ANGLES: RAKKS, EH-INSIDE WALL MOUNT COUNTER SUPPORT BRACKET. SEE MANUFACTURER SPECIFICATIONS FOR SPACING AND SIZE REQUIREMENTS DEPENDENT ON COUNTER DEPTH. ANGLES TO BE PRIMED FOR PAINTING NOTE: AN APPROVED EQUAL TO WALL CLEATS: RAKKS, EH-CS ALUMINUM ANGLE CLEAT STOCK. SEE MANUFACTURER SPECIFICATIONS FOR SPACING AND SIZE REQUIREMENTS DEPENDENT ON COUNTER DEPTH. ANGLES TO BE PRIMED FOR PAINTING *SHOW TOILET ACCESSORY #'S FOR TYPICAL ROOM LAYOUT 1 2' - 6" FIELD VERIFY 4' - 8" NEW PLASTIC LAMINATE (PL-5) COUNTER TOP EXISTING WINDOW SYSTEM NEW WALL BASE NEW WALL SYSTEM (LEAD LINED) NOTES: 1. TYPICAL AT ALL GRAB BAR LOCATIONS. 2. REFER TO ENLARGED TOILET PLAN FOR TOILET ACCESSORIES LOCATIONS. 3. REFER TO ADA CLEARANCES / TOLERANCES DTLS FOR DIMENSIONAL LOCATIONS. WALL ANCHOR AT EACH FLANGE BY MFG. 2x6 FIRE TREATED SOLID WOOD BLOCKING OR 20 GA CONTINUOUS STEEL STRAPPING AT GRAB BARS AND TOILET ACCESSORIES TYPICAL FRAMING BLOCKING IS CONTINUOUS BETWEEN STUDS BLOCKING OR STRAPPING FOR ADDITIONAL TOILET ACCESSORIES                       DRAWING CONTENTS: ISSUE DATE: DRAWING NO. PROJECT NO. ST. VINCENT MICHIGAN ROAD HOPD IMAGING POS22 COMPLIANCE 10801 N MICHIGAN RD, ZIONSVILLE, IN 46077 MKM: ASCENSION: Certification: Key Plan: Consultant Logo: 119 West Wayne Street Fort Wayne, Indiana 46802 p 260.422.0783 f 260.426.4561 www.MKMdesign.com 30329              02/12/2018 17088 A-420         CASEWORK NOTES, LEGEND, & DETAILS 3" = 1'-0" 12" = 1'-0" 2 PLASTIC LAMINATE EDGE DTL. 3 CASEWORK TRIM DTL. 1 1/2" = 1'-0" 1 COUNTER SUPPORT DTL. TOILET ACCESSORIES SCHEDULE ITEM MODEL NO. DESCRIPTION SUPPLIED BY INSTALLED BY 1 MATCH EXISTING MTG 18" GRAB BAR: CONCEALED MOUNTING WITH SNAP FLANGE, REFER TO ADA CLEARANCES AND TOLERANCES DETAIL FOR MOUNTING HEIGHT. CONTRACTOR CONTRACTOR TYPICAL TOILET PLAN 3/8" = 1'-0" 4 CASEWORK - X-RAY ROOM 3/8" = 1'-0" 5 GRAB BAR BLOCKING DTL. REVISION No. Date Revision 04/12/18 Nick Mishler 04/12/18 Nick Mishler