COMBINATION AUDIO/VISUAL ALARM
AUDIBLE ALARM ONLY
TELEVISION OUTLET: WALL MOUNTED DOUBLE GANG BOX WITH
SINGLE GANG RING (VERTICAL) MOUNTED AT 84" A.F.F. U.O.N.
PROVIDE ONE (1) 3/4" EMPTY CONDUIT STUB INTO ACCESSIBLE
CEILING, WITH J-HOOK SUPPORT PATHWAY TO TELECOM CLOSET.
CARD READER WITH PIN PAD WALL MOUNT AT +48" A.F.F.
ELECTRIC DOOR STRIKE (FURNISHED BY G.C., INSTALLED BY E.C.)
OH
ND
NS
N2
N1
CB
DZ
MAS
PC
NB
NC
NCEQ
NCEQ
F#
F#
A 1a
LUMINAIRES
ABBREVIATIONS
POWER EQUIPMENT
LINE TYPE LEGEND
WIRING PLANS
DRAWING REFERENCES
WIRING DEVICES, RECEPTACLES - MISC.
SWITCHES AND LIGHTING CONTROL DEVICES
FIRE ALARM SYSTEMS
SECURITY ALARM SYSTEMS
ELECTRICAL GENERAL NOTES NURSE CALL SYSTEMS
GENERAL DEMOLITION NOTES
DISTRIBUTED TELEVISION
TELECOMMUNICATIONS
JUNCTION AND PULL BOXES
ACCESS CONTROL SYSTEMS
PULL BOX
HEAT DETECTOR : FIXED TEMPERATURE
SPRINKLER SYSTEM WATER FLOW SWITCH
SPRINKLER SYSTEM TAMPER (SUPERVISORY) SWITCH
SPRINKLER SYSTEM ELECTRICAL SOLENOID VALVE
EXTINGUISHING SYSTEM PRESSURE SWITCH
SMOKE DETECTOR : PHOTOELECTRIC TYPE.
END OF LINE RESISTOR
ADDRESSABLE CONTROL RELAY
ADDRESSABLE MONITOR MODULE
SMOKE DAMPER
FIRE ALARM ELECTROMAGNETIC DOOR HOLDER
SINGLE STATION SMOKE DETECTOR WITH SOUNDER BASE
WALL MOUNTED [HORN/BELL/SPEAKER/CHIME] WITH STROBE
WALL MOUNTED STROBE
CEILING MOUNTED WITH STROBE
HEAT DETECTOR : RATE OF RISE
DUCT MOUNTED SMOKE DETECTOR : PHOTOELECTRIC TYPE
CEILING MOUNTED [HORN/BELL/SPEAKER/CHIME] WITH STROBE
CEILING MOUNTED [HORN/BELL/SPEAKER/CHIME]
SHADING INDICATES EMERGENCY POWER
WALL MOUNTED [HORN/BELL/SPEAKER/CHIME]
FIRE ALARM MANUAL STATION: +48" A.F.F. TO CENTER LINE
CONTACT IN KITCHEN EXTINGUISHING SYSTEM PANEL FOR
CONNECTION INTO FIRE ALARM SYSTEM
NEW WORK BY THIS CONTRACTOR
(DARK, SOLID LINE)
EXISTING TO REMAIN OR NEW WORK BY OTHERS
(LIGHT, SOLID LINE)
EXISTING TO BE REMOVED BY THIS CONTRACTOR
(DARK, DASHED LINE, DEMOLITION PLANS)
NEW WORK BY THIS CONTRACTOR TO BE
INSTALLED UNDERGROUND, OR BELOW FLOOR
(DARK, LONG DASHED LINE)
CONDUIT TURNING UP
CONDUIT TURNING DOWN
CONDUIT CAPPED FOR FUTURE.
CABLE TRAY : TYPE AS NOTED
BUSWAY
HOMERUN TO PANEL OR DESTINATION NOTED
ISOLATED GROUND
GROUND
NEUTRAL
PHASE CONDUCTOR
HACHURES INDICATE NUMBER OF CONDUCTORS
IN CONDUIT
NOTE: LONG HACHURE - NEUTRAL CONDUCTOR
NORTH ARROW
PLAN DETAIL REFERENCE TITLE
# KEYED NOTE DESIGNATION
AHU
1
PLAN MARK
EQUIPMENT NUMBER
EQUIPMENT DESIGNATION REFER TO MEP
SCHEDULE FOR CIRCUITING AND DEVICE
REQUIREMENTS AND FLOOR PLANS FOR
LOCATIONS
#
E100 ENLARGED PLAN REFERENCE
1 PLAN MARK
SHEET NUMBER
MOTOR CONTROL CENTER
SWITCHBOARD
PANELBOARD (SURFACE)
ELECTRIC HEATING EQUIPMENT
HANDHOLE
MANHOLE
ELECTRICAL SERVICE METER
PANELBOARD (FLUSH)
VARIABLE FREQUENCY DRIVE
TRANSFORMER
MOTOR : SEE EQUIPMENT DATA SCHEDULE FOR
HORSEPOWER
MAGNETIC STARTER
UNFUSED DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
MAGNETIC STARTER WITH DISCONNECT
PIPE WITH ELECTRIC HEAT TRACING
UNINTERRUPTIBLE POWER SUPPLY SYSTEM
FLOOR BOX : ROUGH IN ONLY WITH BLANK COVER
FLOOR BOX : SYMBOL DESIGNATES TYPE OF SERVICE
DUPLEX RECEPTACLE OUTLET
DUPLEX RECEPTACLE OUTLET : GROUND FAULT TYPE
SPECIAL PURPOSE OUTLET AS NOTED
SINGLE RECEPTACLE OUTLET
DUPLEX RECEPTACLE OUTLET WITH ISOLATED GROUND
DOUBLE DUPLEX RECEPTACLE OUTLET
M
ELECTRICAL CONNECTION: CEILING MOUNTED
SHADING INDICATES EMERGENCY POWER
COMBINATION DUPLEX RECEPTACLE AND TV OUTLET
(SEE TV SYMBOL UNDER "DISTRIBUTED TELEVISION").
TYPICAL MOUNTING HEIGHT: +18" A.F.F.
SUBSCRIPT LEGEND:
A: ABOVE COUNTER: MOUNT +6" ABOVE BACKSPLASH OR
WORK SURFACE.
C: CEILING: MOUNT FLUSH WITHIN CEILING TILE OR GYPSUM
BOARD.
CR: COMPUTER RECEPTACLE: PROVIDE LABEL TO READ:
'COMPUTER'.
S: SWITCHED: PROVIDE ONE OUTLET CONTROLLED BY
TOGGLE SWITCH.
U: UNDER COUNTER: WITHIN CABINETRY OR CASEWORK.
A SLASH BETWEEN TWO SUBSCRIPTS INDICATES MULTIPLE PARAMETERS
(EXAMPLE: A/3 DENOTES ABOVE COUNTER MOUNTING, CIRCUIT 3).
1.
2.
3.
4.
REFER TO LUMINAIRE SCHEDULE FOR LUMINAIRE DESCRIPTIONS.
"NL" INDICATES UNSWITCHED LUMINAIRE
"SE" DESIGNATION INDICATES LUMINAIRE IS SWITCHED DURING NORMAL OPERATION,
BUT UPON LOSS OF POWER, LUMINAIRE REVERTS TO 100% OUTPUT VIA BATTERY
BALLAST, REGARDLESS OF THE ON/OFF STATUS OF THE LOCAL LIGHTING CONTROL
DEVICE. EXTEND AN UNSWITCHED PORTION OF THE LIGHTING CIRCUIT SERVING
AREA, AHEAD OF ALL LIGHTING CONTACTORS, TO THIS DEVICE.
SHADING LEGEND (APPLICABLE TO
LUMINAIRE SYMBOLS):
NO SHADING: NORMAL POWER
HALF-SHADING: LIFE
SAFETY OR
BATTERY BACKUP
FULL-SHADING: CRITICAL POWER
A: LUMINAIRE TYPE
1: CIRCUIT NUMBER
a: CONTROLLING SWITCH
SWITCH - TYPE AS INDICATED BY SUBSCRIPT
CEILING OCCUPANCY DETECTOR : INFRARED SENSOR TYPE.
1.
2.
3.
4.
TYPICAL MOUNTING HEIGHT : 48" A.F.F. TO CENTER U.O.N.
WHERE TWO OR MORE SWITCHES ARE SHOWN ADJACENT TO EACH OTHER,
PROVIDE A COMMON GANG BOX WITH A SINGLE, SEAMLESS FACEPLATE.
SUBSCRIPT LEGEND:
2 : TWO-POLE SWITCH
3 : THREE-WAY SWITCH
4 : FOUR-WAY SWITCH
K : KEY SWITCH
D : DIMMER - COORDINATE REQUIREMENTS FOR LUMINAIRE
COMPATIBILITY
P : PILOT LIGHT SWITCH
C : MOMENTARY CONTACT SWITCH
LV : LOW VOLTAGE CONTROL MASTER STATION
L : LOW VOLTAGE LOCAL SINGLE/PUSH BUTTON STATION
-A LOWERCASE SUBSCRIPT INDICATES THE SWITCHLEG THE DEVICE CONTROLS.
REFER TO SPECIFICATION SECTION 26 09 23 FOR ADDITIONAL INFORMATION.
BUZZER MOUNT AS NOTED
BELL MOUNT AS NOTED
CHIME MOUNT AS NOTED
DOOR ALARM JAMB SWITCH MOUNT AS NOTED
SECURITY CAMERA
SINGLE BED STATION : +48" A.F.F. U.O.N.
DOUBLE BED STATION : +48" A.F.F. U.O.N.
STAFF STATION : +48" A.F.F. U.O.N.
DUTY STATION : +48" A.F.F. U.O.N.
EMERGENCY PUSHBUTTON STATION : +48" A.F.F. U.O.N.
CODE BLUE STATION : +48" A.F.F. U.O.N.
NURSE CALL MASTER STATION : DESK MOUNTED
CEILING MOUNTED ZONE LIGHT.
EMERGENCY PULL CORD STATION: +48" A.F.F. AT TOILETS,
+78" AT SHOWER STATIONS. CORD LENGTH SHALL EXTEND
TO +6" A.F.F.
CEILING MOUNTED DOME LIGHT: CENTERED AT DOOR OPENING
NURSE CALL EQUIPMENT CABINET WITH POWER SUPPLY:
SURFACE MOUNTED
NURSE CALL EQUIPMENT CABINET WITH POWER
SUPPLY: FLUSH MOUNTED
WALL MOUNTED DOME LIGHT: MOUNT ABOVE DOOR JAMB,
CENTERED BETWEEN TOP OF DOOR FRAME AND CEILING
PUSHBUTTON : +48" A.F.F. OR AS NOTED
KEYSWITCH : WALL MOUNT AT +48" A.F.F.
PASSIVE INFRA-RED DETECTOR
BALANCED MAGNETIC SWITCH
ELECTRO-MAGNETIC LOCK
CARD READER : WALL MOUNT AT +48" A.F.F.
POWER SUPPLY
REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT MOUNTING HEIGHTS AND
LOCATIONS. WHERE ELEVATIONS DO NOT SPECIFY, MOUNT DEVICES AS
INDICATED.
MANUAL MOTOR STARTER WITH PILOT LIGHT (+48" A.F.F.)
JUNCTION BOX : CEILING OR FLOOR MOUNTED. SIZE
PER N.E.C. REQUIREMENTS.
JUNCTION BOX : WALL MOUNTED. SIZE PER N.E.C.
REQUIREMENTS.
CEILING PHOTOCELL
POWER POLE
ELECTRICAL CONNECTION: WALL MOUNTED
1.
2.
3.
4.
5.
6.
REFER TO SPECIFICATIONS SECTION 283111 FOR ADDITIONAL INFORMATION
PERTAINING TO THE FIRE ALARM SYSTEM.
SIGNALING LINE CIRCUITS SHALL BE ROUTED IN A CLASS [A] [B]
CONFIGURATION.
NOTIFICATION APPLIANCE CIRCUITS SHALL BE ROUTED IN A CLASS [A] [B]
CONFIGURATION.
FIRE ALARM CIRCUITS SHALL BE ROUTED IN CONDUIT WHERE INACCESSIBLE.
WHERE ROUTED ABOVE ACCESSIBLE CEILINGS, FIRE ALARM CIRCUITS SHALL
CONSIST OF [PLENUM RATED CABLE SUPPORTED EVERY 4'-0"][WIRING WITHIN
CONDUIT] BETWEEN DEVICES.
FOR VISUAL DEVICES, THE '#' WITHIN THE SYMBOL CORRESPONDS TO THE
CANDELA RATING OF THE DEVICE: 1=15cd, 3=30cd, 5=75cd, 7=177cd.
WALL MOUNTED NOTIFICATION DEVICES SHALL BE MOUNTED WITH THE TOP OF
THE DEVICE +90" A.F.F. OR 6" BELOW THE CEILING, WHICHEVER IS LOWER.
RESPONSIBILITIES:
RESPONSIBILITIES:
1.
2.
3.
TYPICAL MOUNTING HEIGHT: +18" A.F.F. UNLESS OTHERWISE NOTED. PROVIDE 4 11/16"
SQUARE BOX WITH SINGLE GANG PLASTER RING (VERTICAL)
ALL TELECOMMUNICATION CONDUIT SHALL BE A MINIMUM OF 1" IN DIAMETER STUBBED
TO ACCESSIBLE CORRIDOR CEILING SPACE, UNLESS OTHERWISE NOTED.
SUBSCRIPT LEGEND:
A: ABOVE COUNTER - MOUNT +6" ABOVE BACKSPLASH OR WORK SURFACE
WITH BOX ORIENTED HORIZONTALLY.
C: CEILING MOUNTED - MOUNT FLUSH WITHIN CEILING TILE OR GYPSUM
CEILING.
W: WALL PHONE - MOUNT +48" A.F.F. OR 6" ABOVE WORK SURFACE. PROVIDE
MOUNTING LUGS FOR TELEPHONE.
WAP: WIRELESS ACCESS POINT DATA OUTLET - FURNISH AND INSTALL A [CAT 6]
CABLE WITH RJ-45 JACK AND 10-'0" OF SLACK CABLE COILED
ABOVE ACCESSIBLE CEILING FROM [TELECOM ROOM]. WIRELESS
ACCESS POINTS ARE [OWNER FURNISHED], [OWNER INSTALLED].
- A SLASH BETWEEN TWO SUBSCRIPTS INDICATES MULTIPLE PARAMETERS (EXAMPLE:
A/3 DENOTES ABOVE COUNTER MOUNTING, 3 CABLES.)
RESPONSIBILITIES:
RESPONSIBILITIES:
RESPONSIBILITIES: RACEWAY AND BOXES: CONTRACTOR FURNISHED,
INSTALLED
WIRING: CONTRACTOR FURNISHED, INSTALLED
DEVICES: CONTRACTOR FURNISHED, INSTALLED
F
F
F#
DS
FW
FT
SD
DH
FK
FR
FM
SD
FV
FP
F#
J
P
M
UPS
VFD
HH
MH
T
E
D
A
V
BMS
PIR
ES
CR
MAG
KS
CRP
PP
E
MAKE ALL INSTALLATIONS IN ACCORDANCE WITH THE [AMERICANS WITH DISABILITIES
ACT ACCESSIBILITY GUIDELINES (ADAAG)] AND/OR [ARCHITECTURAL BARRIERS ACT
(ABA)].
MOUNTING HEIGHTS INDICATED WITHIN PLANS AND SCHEDULES ARE DIMENSIONED TO
THE CENTER LINE OF THE DEVICE, EQUIPMENT, LUMINAIRE, ETC. UNLESS OTHERWISE
NOTED.
COORDINATE EXACT EQUIPMENT LOCATIONS WITH OTHER TRADES. EQUIPMENT
LOCATIONS SHOWN ON ELECTRICAL PLANS ARE DIAGRAMMATICAL ONLY AND MIGHT
NOT BE EXACT.
CIRCUIT IDENTIFICATION NUMBERS BESIDE ELECTRICAL DEVICES AND CONNECTION
POINTS ON PLANS CORRESPOND TO AN OVERCURRENT DEVICE IN THE DESIGNATED
PANELBOARD. NOTE ALL CIRCUIT NUMBER CHANGES MADE IN THE FIELD AT EACH
ELECTRICAL DEVICE AND CONNECTION POINT. ALSO CORRECT THE DIRECTORIES AND
DEVICE MARKINGS AT PANELBOARDS, SWITCHBOARDS AND SWITCHGEAR TO
ACCURATELY REFLECT THE AS-BUILT CONDITIONS.
INSTALL EMERGENCY AND EXIT LUMINAIRE WIRING IN A SEPARATE RACEWAY FROM
THAT OF ANY NORMAL POWER DEVICE.
CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILINGS, OR BELOW FLOOR
SLABS, ETC. UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE
SPECIFICATIONS. CONDUIT ROUTED IN MECHANICAL ROOMS, ELECTRICAL ROOMS,
AND STORAGE ROOMS WITHOUT CEILINGS MAY BE ROUTED EXPOSED.
COORDINATE VERTICAL CONDUIT ROUTING TO WALL MOUNTED DEVICES TO ENSURE
DEVICES LOCATED WITHIN AN 18-INCH HORIZONTAL DIMENSION WILL BE CENTER-
ALIGNED VERTICALLY.
CONCEAL ELECTRICAL CONNECTIONS FOR ELECTRIC WATER COOLERS (EWC) BEHIND
WATER COOLER ACCESS PLATE OR DIRECTLY BELOW AND CENTERED ON WALL.
FIELD COORDINATE ALL ELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT
MOUNTING LOCATIONS TO AVOID ENCROACHMENT OF OPERATION AND ACCESS TO
EQUIPMENT FROM OTHER TRADES. COORDINATE THE APPROPRIATE MOUNTING
LOCATION WITH THE AFFECTED DISCIPLINES WHEN EQUIPMENT IS SPECIFIED TO BE
MOUNTED ONTO THE SURFACE OF ANOTHER DISCIPLINE'S EQUIPMENT.
REPAIR ALL OPENINGS MADE IN EXISTING WALLS, PARTITIONS, ETC TO ACCOMMODATE
WORK OF THIS DISCIPLINE TO MATCH THE SURROUNDING CONDITIONS, USING
WORKERS QUALIFIED IN THE APPROPRIATE TRADE. APPROPRIATELY GROUT OR SEAL
ALL CONDUITS THROUGH WALLS.
ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS
MUST HAVE BEEN TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS
FOR FIRE TESTS OF THROUGH-PENETRATION FIRESTOPS.
INSTALL A PERMANENT DIRECTORY ACCORDING TO THE NATIONAL ELECTRICAL CODE,
ARTICLE 230 AT EACH SERVICE ENTRANCE AND POWER SOURCE.
PERFORM ALL WELDING ACCORDING TO AMERICAN WELDING SOCIETY STANDARDS.
FURNISH CERTIFICATES QUALIFYING EACH WELDER TO THE ARCHITECT OR ENGINEER
PRIOR TO START OF WORK. THE ARCHITECT OR ENGINEER RESERVES THE RIGHT TO
REQUIRE QUALIFYING DEMONSTRATION, AT NO ADDITIONAL EXPENSE, OF ANY
WELDERS ASSIGNED TO THE JOB.
REPLACE OR REINSTALL ALL PORTIONS OF THE BUILDING (CEILING TILES, WALLS, ETC)
REMOVED TO ACCOMMODATE THE INSTALLATION OF ANY ELECTRICAL DEVICE,
EQUIPMENT, ETC., USING WORKERS QUALIFIED IN THE APPROPRIATE TRADE.
COORDINATE LUMINAIRE LOCATIONS SUCH THAT LUMINAIRES RUN PARALLEL TO THE
FACE OF THE EQUIPMENT AND OVER AISLES BETWEEN EQUIPMENT IN ALL
MECHANICAL AND ELECTRICAL EQUIPMENT AREAS. INSTALL AT PROPER LOCATIONS
AND HEIGHTS TO PROPERLY ILLUMINATE ALL GAGES, PANELS, ELECTRICAL
EQUIPMENT, CONTROLS, VALVES, ETC. CHAIN HANGING, STEM HANGING, CHANNEL
HANGING, ETC. ARE ACCEPTABLE METHODS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
REMOVE, CAP AND RELOCATE EQUIPMENT, OUTLETS, CONDUIT, WIRE, ETC., AS SHOWN
AND SPECIFIED ON DRAWINGS, AND AS MAY BECOME NECESSARY BECAUSE OF
EXISTING FIELD CONDITIONS. VISIBLY EXAMINE ALL EXISTING WALLS DESIGNATED FOR
REMOVAL TO DETERMINE THE CONDUIT AND THE WIRING THAT WILL REQUIRE CAPPING
AND REMOVAL, WHETHER OR NOT SUCH CONDITIONS ARE INDICATED ON THE
DRAWINGS. FAILURE TO VISIT THE SITE AND TO TAKE ALL EXISTING CONDITIONS INTO
ACCOUNT WILL NOT ALLOW FOR CHANGES TO THE SCOPE OF WORK.
MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING FIXTURES, EQUIPMENT, OUTLETS, ETC.,
TO REMAIN IN USE WHETHER NOTED ON THE PLANS OR NOT. FIELD VERIFY EXISTING
ITEMS TO REMAIN IN USE. RECONNECT RACEWAYS AND WIRING FOR EXISTING CIRCUITS
WHICH MUST BE RE-ROUTED OR WHICH ARE PARTIALLY ABANDONED TO POWER THE
REMAINING OUTLETS ON THE CIRCUIT.
REMOVE ALL UNUSED WIRING AND CABLES BACK TO THEIR SOURCE. REMOVE ALL
UNUSED CONDUIT THAT IS EXPOSED OR ABOVE ACCESSIBLE CEILINGS WHICH IS
AFFECTED BY OR IS IN THE AREA OF THE DEMOLITION WORK.
THE INTENTION OF THE ELECTRICAL DEMOLITION DRAWINGS IS TO DISCONNECT AND
REMOVE ALL ELECTRICAL WORK MADE VOID BY THE SCOPE OF THE CONSTRUCTION
AND ALTERATION. FIELD VERIFY EXACT MATERIAL QUANTITIES REQUIRED TO BE
REMOVED.
DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, DEVICES,
ASSOCIATED RACEWAYS, SUPPORTING HARDWARE, AND WIRING, WHICH HAVE BEEN
MADE OBSOLETE BY THE WORK OR IS SHOWN DASHED ON THE ELECTRICAL
DEMOLITION DRAWINGS, UNLESS OTHERWISE NOTED. ALTHOUGH AN ATTEMPT HAS
BEEN MADE TO INDICATE ALL OF THIS WORK, TOTAL ACCURACY IS NOT GUARANTEED.
VISIBLY EXAMINE ALL AREAS AND WALLS AND CEILINGS SCHEDULED FOR REMOVAL TO
DETERMINE EXISTING ELECTRICAL ITEMS TO REMAIN.
WHERE ELECTRICAL EQUIPMENT, CONDUIT, BOXES, AND SUPPORTING HARDWARE ARE
REMOVED, PATCH AND FINISH THE SURFACE AS REQUIRED TO MATCH THE EXISTING,
USING WORKERS QUALIFIED IN THE APPROPRIATE TRADE.
WHERE BURIED CONDUITS EXTENDING OUT OF A CONCRETE SLAB BECOME
ABANDONED, CUT AND GRIND THE CONDUITS OFF FLUSH WITH TOP OF SLAB AND PLUG
WITH NON-SHRINK WATERPROOF GROUT FILL.
TAKE ALL REMOVED MATERIALS FROM THE PROJECT SITE, EXCEPT FOR THOSE TO BE
RELOCATED, STORED, OR TURNED OVER TO THE OWNER.
ACCEPTANCE OF CONTRACT MEANS INSTALLER ACCEPTS EXISTING CONDITIONS.
COORDINATE ALL DEMOLITION WORK WITH ALL OTHER TRADES.
PROVIDE A BLANK COVER OVER THE OUTLET WHERE A FLUSH DEVICE IS BEING
REMOVED FROM FLOORS AND WALLS THAT ARE TO REMAIN. MATCH THE COLOR AND
MATERIAL TO THE EXISTING REMAINING COVERS IN THE ROOM OR SPACE.
LEGALLY DISPOSE OF HAZARDOUS MATERIALS AND BALLASTS OR OTHER EQUIPMENT
CONTAINING PCBS AND LAMPS CONTAINING MERCURY. COMPLY WITH ALL FEDERAL,
STATE, AND LOCAL LAWS.
MODIFY EXISTING PANEL DIRECTORIES (OR REPLACE) FOR PANELBOARDS WHICH HAVE
HAD ALTERATIONS TO THE CIRCUITS ORIGINATING THEREIN. DESCRIBE THE LOAD AND
LOCATION. TYPE, DO NOT HAND LETTER NEW PANELBOARD DIRECTORIES.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
A.F.F : ABOVE FINISHED FLOOR
C : CONDUIT
E.C. : ELECTRICAL CONTRACTOR
ER : EXISTING RELOCATED
ETR : EXISTING TO REMAIN
EWC : ELECTRIC WATER COOLER
G.C. : GENERAL CONTRACTOR
GND : GROUND
TYP. : TYPICAL
U.O.N. : UNLESS OTHERWISE NOTED
PROVIDE WIRING REQUIRED BY THE CIRCUITING AND SWITCHING
REQUIREMENTS FOR THE PARTICULAR CIRCUITS INVOLVED. TYPICAL
120V HOMERUNS SHALL CONSIST OF #12 AWG CONDUCTORS IN 3/4"
CONDUIT MINIMUM UNLESS INDICATED OTHERWISE. NO SHARED
NEUTRALS SHALL BE ALLOWED. A MAXIMUM OF NINE CURRENT-
CARRYING CONDUCTORS ARE ALLOWED IN A RACEWAY. NEUTRAL
CONDUCTORS ARE ALSO CONSIDERED CURRENT-CARRYING
CONDUCTORS. FOR CIRCUITS EXCEEDING 75'-0" IN LENGTH, PROVIDE
THE NEXT LARGER WIRE SIZE FOR THE CIRCUIT AMPACITY.
WHERE NUMBER OF CURRENT-CARRYING CONDUCTORS IN A
RACEWAY EXCEEDS THREE, THE ALLOWABLE AMPACITY OF EACH
CONDUCTOR SHALL BE REDUCED AS SHOWN IN THE ADJUSTMENT
FACTOR TABLE IN THE NATIONAL ELECTRIC CODE. LOAD DIVERSITY
FACTORS SHALL NOT BE USED IN SIZING CONDUCTORS. NEUTRAL
CONDUCTORS SHALL BE COUNTED AS CURRENT-CARRYING
CONDUCTORS.
1.
2.
RACEWAY AND BOXES: CONTRACTOR FURNISHED, INSTALLED
WIRING: CONTRACTOR FURNISHED, INSTALLED
DEVICES: CONTRACTOR FURNISHED, INSTALLED
1.
2.
5. LUMAINAIRE DESIGNATION KEY:
RACEWAY AND BOXES: CONTRACTOR FURNISHED, INSTALLED
WIRING: CONTRACTOR FURNISHED, INSTALLED
DEVICES: CONTRACTOR FURNISHED, INSTALLED
RACEWAY AND BOXES: CONTRACTOR FURNISHED, INSTALLED
WIRING: CONTRACTOR FURNISHED, INSTALLED
DEVICES: CONTRACTOR FURNISHED, INSTALLED
1.
RACEWAY AND BOXES: CONTRACTOR FURNISHED, INSTALLED
WIRING: CONTRACTOR FURNISHED, INSTALLED
DEVICES: CONTRACTOR FURNISHED, INSTALLED
DATA OUTLET WITH 4 POSITION FACEPLATE & TOTAL OF [(2)] ACTIVE
JACKS AND [(2)] [CAT 6e CABLES].
TELEPHONE OUTLET WITH SINGLE POSITION FACEPLATE & TOTAL OF
[(1)] ACTIVE JACK AND [(1)] [CAT 6e] CABLE.
COMBINATION VOICE/DATA OUTLET WITH 4 POSITION FACEPLATE &
TOTAL OF [(2)] ACTIVE DATA JACKS, [(1)] ACTIVE VOICE JACK AND [(3)]
[CAT 6e CABLES].
DUPLEX RECEPTACLE OUTLET : INTELLIGENTLY CONTROLLED
SO WALL MOUNTED SINGLE SWITCH OCCUPANCY SENSOR
Drawing Name:
Plot Time/Date:
DRAWING CONTENTS:
ISSUE DATE:
DRAWING NO.
PROJECT NO.
ST. VINCENT
MICHIGAN ROAD
HOPD
IMAGING POS22
COMPLIANCE
10801 N MICHIGAN RD,
ZIONSVILLE, IN 46077
MKM:
ASCENSION:
Certification:
Key Plan:
Consultant Logo:
119 West Wayne Street
Fort Wayne, Indiana 46802
p 260.422.0783
f 260.426.4561
www.MKMdesign.com
30329
2/1 3/201 8 8:54:1 9 AM
02/01/2018 17088
E-001
Template.rte
ELECTRICAL SYMBOLS
& ABBREVIATIONS
REVISION
No. Date Revision
1905-23 2/12/2018
04/12/18
Nick Mishler
04/12/18
Nick Mishler