HomeMy WebLinkAboutBBG Construction-Sumner Basement Remodel 24x36 FinalTHESE DRAWINGS ARE THE PROPRIETARY WORKPRODUCT AND PROPERTY OF BBG CONSTRUCTION,DEVELOPED FOR THE EXCLUSIVE USE OF BBGCONSTRUCTION.USE OF THESE DRAWINGS ANDCONCEPTS CONTAINED THEREIN WITHOUT THEWRITTEN PERMISSION OF BBG CONSTRUCTION ISPROHIBITED AND MAY SUBJECT YOU TO A CLAIM FORDAMAGES.SHELVING
C01C01
C01C01
C01C01
C02C02
C05C05
C05C05
C07C07
C07C07
C01C01
C01C01
C01C01
C02C02
C05C05
C05C05
C07C07 DISHWASHERC07C07
C04C04
C04C04
W01W01
W01W01
30" SC 108X80 DOORWAY24X80 DOORWAY42X73 CASE32" SC32X80 DOORWAY 24" SC36" SC32" SC
UP
54'25'12'-8" 6'-8" 13'-11 1/4"
32'-7 5/8"16'-4 3/8"37'12'-4"23'-8"2'2'19'-8 7/8"13'-10 5/8"
3'7'-11 1/2"3'
3'
16'-6 1/8"15'-9 3/8"7'-11" 11'-6 1/2"24'-6 3/4"
3'-10"5'9'
6'-9 1/4"5'-0 5/8"12'-11 1/2"3'-1 1/2" 12'16'-7 1/8"8'-6"2'-2 3/4"16'-8 1/2"5'-3 1/2"10'-0 5/8" 3'3'
1597 SQ FT
16'-5" X 19'-4"
291 SQ FT
10'-8" X 16'-8"158 SQ FT
23'-0" X 23'-7"
573 SQ FT
13'-10" X 17'-11"
232 SQ FT
6'-8" X 5'-0"
33 SQ FT
12'-0" X 8'-0"
96 SQ FT
7'-0" X 15'-8"
158 SQ FT
5'-11" X 4'-11"29 SQ FT
3'-0" X 16'-1"
48 SQ FT
3'-0" X 4'-11"
15 SQ FT
LIVING AREA
BAR
LIVING
BEDROOM
MULTIUSE
UTILITY
THEATER
UTILITY
BATH
SHOWER
WALK-IN CLOSET
MEP BULKHEAD
SUMP PUMP
EXISTING STRUCTURAL POST
EXISTING MAIN ELECTRICAL PANEL
2.5X3X8" BRICK
TREATED 2X4 SILL PLATE
CONTINUOUS POUR 7 5/8" STEM WALL W/ BRICK LEDGE
GRADE LINE
CONTINUOUS POUR 8X16" FOOTER
UNDISTURBED SOIL
VAPOR BARRIER
CORRUGATED DRAINAGE PIPE
SINGLE 2X4 TREATED BASE PLATE
GRAVEL FILL
VAPOR BARRIER
2X4 FRAMING 16" O.C.
DOUBLE 2X4 TOP PLATE
TYPICAL 2X4 FURRED WALL AND 7 5/8" STEM WALL W/ BRICK LEDGE
(SCALE ½"=1')
A-1
SHEET#
SCALE:BBG Construction15034 Declaration DriveWestfield, IN 46074bbgconstruction.comDATE:
4/6/2018
¼" = 1'LAYOUTSUMNERS BASEMENT12864 Birkenstock Street Carmel, IN 46032SUMNERS BASEMENT REMODEL
PRIMARY CEILING HEIGHT 105.5"
(BAR AND THEATER CEILING HEIGHT 97 1/8")
Scale ¼" x 1'
Notes
All Interior dimensions are to wall framing
All opening dimensions are to rough opening or center line
All interior walls are framed using 2x4 dimensional lumber unless otherwise noted
All interior walls are framed using double 2x4 top plate w/ single 2x4 treated bottom plate
Foundation stem walls are 7 5/8" with a 3 1/2" brick ledge and 4 1/8" upper stem wall
CROSS SECTION
Scale ½" = 1'
04/13/18
David Rutti
THESE DRAWINGS ARE THE PROPRIETARY WORKPRODUCT AND PROPERTY OF BBG CONSTRUCTION,DEVELOPED FOR THE EXCLUSIVE USE OF BBGCONSTRUCTION.USE OF THESE DRAWINGS ANDCONCEPTS CONTAINED THEREIN WITHOUT THEWRITTEN PERMISSION OF BBG CONSTRUCTION ISPROHIBITED AND MAY SUBJECT YOU TO A CLAIM FORDAMAGES.UP
R
R
R
R R
R
R
R
R
R
R
R
R
R
R
RR
R R
R
R R
R
EP
GFCI
GFCI
GFCI
3DM
3DM
DM
DM
1597 SQ FT
LIVING AREA
BAR
LIVING
BEDROOM
MULTIUSE
UTILITY
THEATER
UTILITY
BATH
SHOWER
WALK-IN CLOSET
MEP BULKHEAD
EXISTING MAIN ELECTRICAL PANEL
ELECTRICAL SCHEDULE
2D SYMBOL NUMBER QTY FLOOR WIDTH DEPTH HEIGHT ATTACHED TO DESCRIPTION CODE MANUFACTURER COMMENTS NUMBER
E01 1 1 12 " 12 " 1 1/4 " CEILING BATHROOM EXHAUST (LIGHT) E01
E02 1 1 14 1/4 " 3 3/8 " 23 " WALL ELECTRICAL PANEL E02
E03 1 1 18 15/16 " 18 15/16 " 6 1/2 " CEILING CONTEMPORARY FLUSH E03
E04 1 1 20 1/2 " 6 1/8 " 10 5/16 " WALL MURRAY FEISS SCONCE 3 E04
E05 2 1 3 " 1/2 " 5 " WALL SINGLE POLE (SLIDING DIMMER) E05
E06 10 1 3 " 1/2 " 5 " WALL SWITCH (DECORATOR) E06
E07 2 1 3 " 1/2 " 5 " WALL THREE WAY (SLIDING DIMMER) E07
E08 25 1 3 " 5/16 " 5 " WALL E08
E09 3 1 3 " 5/16 " 5 " WALL GFCI E09
E10 3 1 4 " 4 " 5 1/2 " CEILING BARE BULB E10
E11 22 1 7 3/8 " 7 3/8 " 5/16 " CEILING 6" CAN E11
E12 1 1 7 3/8 " 7 3/8 " 5/16 " CEILING RECESSED VAPOR LIGHT E12
E13 2 1 9 9/16 " 9 9/16 " 42 " CEILING TRADITIONAL PENDANT E13
EP
DM
3DM
GFCI
R
R
A-2
SHEET#
SCALE:BBG Construction15034 Declaration DriveWestfield, IN 46074bbgconstruction.comDATE:
4/6/2018
¼" = 1'SUMNERS BASEMENT12864 Birkenstock StreetCarmel, IN 46032ELECRICAL LAYOUT / SCHEDULE
Scale ¼" x 1'ELECTRICAL LAYOUT
04/13/18
David Rutti