Loading...
HomeMy WebLinkAboutBBG Construction-Sumner Basement Remodel 24x36 FinalTHESE DRAWINGS ARE THE PROPRIETARY WORKPRODUCT AND PROPERTY OF BBG CONSTRUCTION,DEVELOPED FOR THE EXCLUSIVE USE OF BBGCONSTRUCTION.USE OF THESE DRAWINGS ANDCONCEPTS CONTAINED THEREIN WITHOUT THEWRITTEN PERMISSION OF BBG CONSTRUCTION ISPROHIBITED AND MAY SUBJECT YOU TO A CLAIM FORDAMAGES.SHELVING C01C01 C01C01 C01C01 C02C02 C05C05 C05C05 C07C07 C07C07 C01C01 C01C01 C01C01 C02C02 C05C05 C05C05 C07C07 DISHWASHERC07C07 C04C04 C04C04 W01W01 W01W01 30" SC 108X80 DOORWAY24X80 DOORWAY42X73 CASE32" SC32X80 DOORWAY 24" SC36" SC32" SC UP 54'25'12'-8" 6'-8" 13'-11 1/4" 32'-7 5/8"16'-4 3/8"37'12'-4"23'-8"2'2'19'-8 7/8"13'-10 5/8" 3'7'-11 1/2"3' 3' 16'-6 1/8"15'-9 3/8"7'-11" 11'-6 1/2"24'-6 3/4" 3'-10"5'9' 6'-9 1/4"5'-0 5/8"12'-11 1/2"3'-1 1/2" 12'16'-7 1/8"8'-6"2'-2 3/4"16'-8 1/2"5'-3 1/2"10'-0 5/8" 3'3' 1597 SQ FT 16'-5" X 19'-4" 291 SQ FT 10'-8" X 16'-8"158 SQ FT 23'-0" X 23'-7" 573 SQ FT 13'-10" X 17'-11" 232 SQ FT 6'-8" X 5'-0" 33 SQ FT 12'-0" X 8'-0" 96 SQ FT 7'-0" X 15'-8" 158 SQ FT 5'-11" X 4'-11"29 SQ FT 3'-0" X 16'-1" 48 SQ FT 3'-0" X 4'-11" 15 SQ FT LIVING AREA BAR LIVING BEDROOM MULTIUSE UTILITY THEATER UTILITY BATH SHOWER WALK-IN CLOSET MEP BULKHEAD SUMP PUMP EXISTING STRUCTURAL POST EXISTING MAIN ELECTRICAL PANEL 2.5X3X8" BRICK TREATED 2X4 SILL PLATE CONTINUOUS POUR 7 5/8" STEM WALL W/ BRICK LEDGE GRADE LINE CONTINUOUS POUR 8X16" FOOTER UNDISTURBED SOIL VAPOR BARRIER CORRUGATED DRAINAGE PIPE SINGLE 2X4 TREATED BASE PLATE GRAVEL FILL VAPOR BARRIER 2X4 FRAMING 16" O.C. DOUBLE 2X4 TOP PLATE TYPICAL 2X4 FURRED WALL AND 7 5/8" STEM WALL W/ BRICK LEDGE (SCALE ½"=1') A-1 SHEET# SCALE:BBG Construction15034 Declaration DriveWestfield, IN 46074bbgconstruction.comDATE: 4/6/2018 ¼" = 1'LAYOUTSUMNERS BASEMENT12864 Birkenstock Street Carmel, IN 46032SUMNERS BASEMENT REMODEL PRIMARY CEILING HEIGHT 105.5" (BAR AND THEATER CEILING HEIGHT 97 1/8") Scale ¼" x 1' Notes All Interior dimensions are to wall framing All opening dimensions are to rough opening or center line All interior walls are framed using 2x4 dimensional lumber unless otherwise noted All interior walls are framed using double 2x4 top plate w/ single 2x4 treated bottom plate Foundation stem walls are 7 5/8" with a 3 1/2" brick ledge and 4 1/8" upper stem wall CROSS SECTION Scale ½" = 1' 04/13/18 David Rutti THESE DRAWINGS ARE THE PROPRIETARY WORKPRODUCT AND PROPERTY OF BBG CONSTRUCTION,DEVELOPED FOR THE EXCLUSIVE USE OF BBGCONSTRUCTION.USE OF THESE DRAWINGS ANDCONCEPTS CONTAINED THEREIN WITHOUT THEWRITTEN PERMISSION OF BBG CONSTRUCTION ISPROHIBITED AND MAY SUBJECT YOU TO A CLAIM FORDAMAGES.UP R R R R R R R R R R R R R R R RR R R R R R R EP GFCI GFCI GFCI 3DM 3DM DM DM 1597 SQ FT LIVING AREA BAR LIVING BEDROOM MULTIUSE UTILITY THEATER UTILITY BATH SHOWER WALK-IN CLOSET MEP BULKHEAD EXISTING MAIN ELECTRICAL PANEL ELECTRICAL SCHEDULE 2D SYMBOL NUMBER QTY FLOOR WIDTH DEPTH HEIGHT ATTACHED TO DESCRIPTION CODE MANUFACTURER COMMENTS NUMBER E01 1 1 12 " 12 " 1 1/4 " CEILING BATHROOM EXHAUST (LIGHT) E01 E02 1 1 14 1/4 " 3 3/8 " 23 " WALL ELECTRICAL PANEL E02 E03 1 1 18 15/16 " 18 15/16 " 6 1/2 " CEILING CONTEMPORARY FLUSH E03 E04 1 1 20 1/2 " 6 1/8 " 10 5/16 " WALL MURRAY FEISS SCONCE 3 E04 E05 2 1 3 " 1/2 " 5 " WALL SINGLE POLE (SLIDING DIMMER) E05 E06 10 1 3 " 1/2 " 5 " WALL SWITCH (DECORATOR) E06 E07 2 1 3 " 1/2 " 5 " WALL THREE WAY (SLIDING DIMMER) E07 E08 25 1 3 " 5/16 " 5 " WALL E08 E09 3 1 3 " 5/16 " 5 " WALL GFCI E09 E10 3 1 4 " 4 " 5 1/2 " CEILING BARE BULB E10 E11 22 1 7 3/8 " 7 3/8 " 5/16 " CEILING 6" CAN E11 E12 1 1 7 3/8 " 7 3/8 " 5/16 " CEILING RECESSED VAPOR LIGHT E12 E13 2 1 9 9/16 " 9 9/16 " 42 " CEILING TRADITIONAL PENDANT E13 EP DM 3DM GFCI R R A-2 SHEET# SCALE:BBG Construction15034 Declaration DriveWestfield, IN 46074bbgconstruction.comDATE: 4/6/2018 ¼" = 1'SUMNERS BASEMENT12864 Birkenstock StreetCarmel, IN 46032ELECRICAL LAYOUT / SCHEDULE Scale ¼" x 1'ELECTRICAL LAYOUT 04/13/18 David Rutti