HomeMy WebLinkAboutTelamon Office Renovation_Architectural Drawings_Updated 2LIFE SAFETY PLAN LEGEND INDICATES ONE-HOUR RATED CONSTRUCTION X 0 0 0 0 0 0 INDICATES TWO- HOUR RATED CONSTRUCTION - - INDICATES EGRESS PATH FEC INDICATES FIRE EXTINGUISHER LOCATION CODE SUMMARY PLUMBING FIXTURE REQUIRED (PLUMBING OCCUPANT LOAD) Based on actuay occupant load: 50 Males 50 Females OCCUPANT LOAD EGRESS CAPACITY TAG VARIANCE 24 Avariance was filed (ID Number X16139) for state approval for July 26 J hearing to not require elements and spaces on the 2nd floor to comply with accessibility requirements. OCCUPANT CAPACITY NUMBER OF OCCUPANTS OCCUPANCY TAG SPACE FUNCTION FROMTABLE 1004.1.1B 32 B = Business/Office 24000 SF S = Storage M =Mechanical AREAOF SPACE A = Assembly (net or gross) APPLICABLE CODES Indiana General Administrative Rules 2014 Indiana Building Code (2012 International Building Code with Indiana Ammendments) 2014 Indiana Fire Code (2012 International Fire Code with Indiana Ammendments) 2012 Indiana Plumbing Code (2006 International Plumbing Code with Indiana Ammendments) 2008 National Electrical Code (2008 NFPA 70) 2014 Indiana Mechanical Code (2012 International Mechanical Code with Indiana Ammendments) 2010 Indiana Energy Code (ASHRAE 90.1 2007) Americans with Disabilities Act Accessible Guidelines (ADAAG) for Buildings and Facilities American National Standards Institute Accessible and Usable Buildings and Facilities Standard (CABO/ANSI A117.1-2009) SCOPE OF PROJECT New two-story fire station with basement. OCCUPANCY CLASSIFICATION B Occupancy (304.1) CONSTRUCTION TYPE Type VB - Permitted based upon allowable area and height for B occupancy with area increases. See box to left. ALLOWABLE AREA Tabular Area: 23,000 sf 3 Stories (Table 503) Actual Area Per Floor: First Floor: 18,544 sf Mezzanine: 1,579 sf Second Floor: 5,443 sf Total: 25,566 sf FIRE RESISTIVE REQUIREMENTS Fire resistive requirements based on Type VB construction are as follows: Building Elements REQUIRED PROVIDED 0 hour (Table 601) MALE FEMALE MALE FEMALE UNISEX WATER CLOSETS 2 2 5 3 2 URINALS Exit access corridors 0 hour (Table 1018. 1) 7 0 hour (Table 60 1) Exit stair enclosures LAVATORIES 2 2 4 2 0 1 2 DRINKING FOUNTAIN SERVICE SINK 1 2 OCCUPANT LOAD EGRESS CAPACITY TAG VARIANCE 24 Avariance was filed (ID Number X16139) for state approval for July 26 J hearing to not require elements and spaces on the 2nd floor to comply with accessibility requirements. OCCUPANT CAPACITY NUMBER OF OCCUPANTS OCCUPANCY TAG SPACE FUNCTION FROMTABLE 1004.1.1B 32 B = Business/Office 24000 SF S = Storage M =Mechanical AREAOF SPACE A = Assembly (net or gross) APPLICABLE CODES Indiana General Administrative Rules 2014 Indiana Building Code (2012 International Building Code with Indiana Ammendments) 2014 Indiana Fire Code (2012 International Fire Code with Indiana Ammendments) 2012 Indiana Plumbing Code (2006 International Plumbing Code with Indiana Ammendments) 2008 National Electrical Code (2008 NFPA 70) 2014 Indiana Mechanical Code (2012 International Mechanical Code with Indiana Ammendments) 2010 Indiana Energy Code (ASHRAE 90.1 2007) Americans with Disabilities Act Accessible Guidelines (ADAAG) for Buildings and Facilities American National Standards Institute Accessible and Usable Buildings and Facilities Standard (CABO/ANSI A117.1-2009) SCOPE OF PROJECT New two-story fire station with basement. OCCUPANCY CLASSIFICATION B Occupancy (304.1) CONSTRUCTION TYPE Type VB - Permitted based upon allowable area and height for B occupancy with area increases. See box to left. ALLOWABLE AREA Tabular Area: 23,000 sf 3 Stories (Table 503) Actual Area Per Floor: First Floor: 18,544 sf Mezzanine: 1,579 sf Second Floor: 5,443 sf Total: 25,566 sf FIRE RESISTIVE REQUIREMENTS Fire resistive requirements based on Type VB construction are as follows: Building Elements Minimum Fire Resistance Beams 0 hour (Table 601) Columns 0 hour (Table 601) Exterior bearing walls 0 hour (Table 601) Exterior non-bearing walls 0 hour > 10 ft. yard (Table 602) Interior bearing walls 0 hour (Table 601) Interior non-bearing walls Non-combustible (Table 601 and Sec. 602.2) Exterior parapet walls Not required (Sec. 704.11, Exception 1 and 6) Exit access corridors 0 hour (Table 1018. 1) Floors 0 hour (Table 60 1) Exit stair enclosures Not Required (Sec. 1009.3, Exc. 1) ZLU Note: Interior stair from basement to first floor will be enclosed with 1 -hour fire barriers per section 1022. Shafts 1 hour (Sec. 707.4) Vertical openings: LJJ Protection of vertical Non-combustible items, including ducts, can openings in non -rated penetrate two (2) floors with non -rated floors assemblies and connect up to three (3) stories without a shaft or damper. Annular space U. (between the floor and penetrating item) must be filled with non-combustible material to resist 10 free passage of flame and products of Zr combustion (Sec. 711. 4. 3. 1). Combustible items can penetrate only one (1) non -rated floor assembly, and connect up to two (2) stories without a shaft or damper. The annular space between the floor penetrating item must be filled with non-combustible materials to resist free passage of flame and products of combustion (Sec. 711. 4. 3. 2). Roof: Z Roof deck fire resistance 0 hour (Table 601) Supporting members 0 hour (Table 601) Roof surfacing Class A, B, or C (Table 1505.1) Protection of openings: Exterior walls 0 hour (Table 704. 8) Vertical shafts 1 hour (Table 715. 4) Incidental -use rooms Doors with closers (Sec. 508. 2. 2. 1) Elevator and Equipment Room: The elevator shaft and machine room will be enclosed with 2 -hour construction in order to omit 7 L_ sprinkler protection from these spaces. ZLU (903.3.1.1.1) INCIDENTALUSE SEPARATIONS Incidental use areas are required to be provided with smoke tight construction. Partitions shall extend from the floor to the underside of the floor, roof deck above, or tight ceiling. Doors shall be self-closing or automatic -closing upon detection of smoke. Air-transferopenings shall be provided with smoke dampers. Duct work does not need to be dampered. (509.4.2) The following areas are considered incidental use areas: (IBC Table 509). Boiler and fuel equipment rooms over 400,000 BTUs/hour input. Laundry rooms over 100 sq. ft. OTHER SEPARATION Electrical "Rooms" Electrical vaults > 600 volts Transformers Dry type< 112-1/2 kVA > 112-1/2 kVA 3 hour rating [IEC, Sec. 110. 31 (A)] Not required [IEC 450.21. (A)] 1 hour [IEC 4502. 1 (B)]; See exception Vaults See section IEC 450.41 for exceptions Switch gear -unenclosed In a vault following IEC 450.41 Switch gear over 35,000 volts through 450.48; See IEC 230.212 NUMBER OF EXITS 2 means of egress are required from rooms or areas with an occupant load exceeding 50 or a common path of travel exceeding 100 feet. (1015.1) # Exits Basement 1 First Floor 2 Second Floor 2 OCCUPANT LOAD AND EGRESS CAPACITY See Occpancy Schedule this sheet for building occupant load Total egress capacity provided exceed occupant load. Refer to plans this sheet. EGRESS CORRIDORS Egress corridors are not require to be fire rated based upon automatic sprinkler protection. (1018.1 ) EGRESS TRAVEL DISTANCE Table 1016. 1, IBC limits the maximum travel distance in a sprinklered B occupancy to 300 feet. EXITING Doors serving an area required to have two (2) or more exits shall swing in the direction of egress travel (IBC, Sec. 1 008.1.2). DOOR SWING Doors serving an area required to have two (2) or more exits shall swing in the direction of egress travel (IBC, Sec. 1 008.1.2). PANIC HARDWARE Not required in a B occupancy. (1008.1 .10) FIRE PROTECTIONS SYSTEMS Sprinklers Provide per NFPA 13 Portable fire extinguishers Required per Carmel Indianal-ocal Code Smoke detection Recommend interconnected smoke alarms in sleeping areas as a minimum Standpipes Are not required based upon the elevation of the 2nd floor level at less than 30 feet above grade (905.3.1) Fire Alarm System Not required based upion a calculated occupant load of over 100 above or below the level or discharge. (907.2.2) Smoke Detectors Are required for HVAC shutdown for systems delivering in excess of 2000 CFM, and for elevator recall. (3003.2, 606.1 IMC) PROJECT SCOPE HIGHLIGHTED IN GRAY. PROJECT SCOPE HIGHLIGHTED IN GRAY. Exit signs Required (Sec. 1011. 1) RELEASED FOR CONSTRUCTION Exit illumination Required (Sec. 1 006) p SuhlecltDeamipllianicewith all regulatiians Iwith emergency power if State and (Local Cudles intro DATE: 04/13/18 a, , Nick Mishler 6 1 8 East M arket Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h. c o m Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarilyindicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. DRAWN BY Author CHECKED BY DATE ISSUED 02/28/2018 REVISIONS: # DESCRIPTION DATE Owner: Telamon Corporation 1000 E 116th St Carmel, IN 46032 317 818-6888 Construction Manager: Capitol Construction 11051 Village Square Lane Fishers, IN 46038 317 574-5488 Electrical Engineer: Crew Corp 7768 Zionsville Rd # 150 Indianapolis, IN 46268 PH 317 713-7777 Mechanical Engineer: Swift Air Mechanical, Inc. 4537 N Franklin Rd Indianapolis, IN 46226 PH 3 1 7 547-5355 Plumbing Engineer: Bell Plumbing Service Suite 400 Greenwood, IN 46143 PH 317 886-7220 D < G \ ST �O No. z AR -19490087 � �STATE of No i ANP CODE REVIEW AND LIFE SAFETY PLAN G002 PROJECT NUM BER: 16095 Z N OM 0 Q V O 7 L_ ZLU O JXL E LJJ V � V � U. s O 10 Zr - O LL O Q O IIIIIIIIIIIIIIII� O W D < G \ ST �O No. z AR -19490087 � �STATE of No i ANP CODE REVIEW AND LIFE SAFETY PLAN G002 PROJECT NUM BER: 16095