HomeMy WebLinkAboutTelamon Office Renovation_Architectural Drawings_Updated 5�►VA. Y TYPE CAB. CABINET F.O. FINISH OPENING N.A.F. NO APPLIEDFINISH T.C. TOP OF CURB ADA COMPLIANT FS ONE GYPSUM C.F.C.I. CONTRACTOR FURNISHED- F.O.B. FACE OF BLOCK N.I.C. NOT IN CONTRACT ABBREVIATIONS TOP OF DECK BOBRICK B-6806 SERIES 36", 42"AND 18" VERTICAL U.V. TOILET ACCESSORY MOUNTING HEIGHTS CONTRACTOR INSTALLED GENERAL PROJECT NOTES MISCELLANEOUS E TECH. J SOAP DISPENSER R ADA COMPLIANT C.G. CORNERGUARD 11 61' SCOPE DRAWINGS AND SPECIFICATIONS, AS DEFINED BYTHE CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH ALL ASPECTS NOT TO SCALE TEL. TELEPHONE T7 SHOWER ROD 48", HOOKS AND CURTAIN BOBRICK B-207 C.I.P. CAST -IN-PLACE F.O.F. FACE OF FINISH O BOBRICK B-6827 TEMP. TEMPORARY NOTED INDIANA CONSTRUCTION INDUSTRY COUNCIL'S GUIDELINES, OF THE WORK, EVEN THOSE AREAS DESIGNATED TO BE PROVIDED BY CJ. CONTROLJOINT F.O.G. FACE OF GYPSUM BD. EA. EACH ACH JAN. JANITOR R RADIUS PAIR CL. CENTERLINE F.O.S. OTHERS. THIS FAMILIARIZATION INCLUDES FULL AND COMPLETE O.A. OVERALL � TOP OF MASONRY E.C. ELECTRICALCONTRACTOR J.C. JANITOR CLOSET R.C.P. REFLECTEDCEILING PLAN FIREPROOF O.C. ON CENTER A. THE CONTRACTOR SHALL OBSERVE THE FOLLOWING: UNDERSTANDING OF THE WORK DESCRIBED OLLSHEETS OF THE B. ALLDIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL DRAWINGS. CENTERLINE E.I.F.S. EXTERIOR INSULATION JST. BRIG. JOIST BEARING R.D. ROOFDRAIN TOPOF VERT. VERTICAL DRAWINGS AND IN ALLSECTIONS OF THE PROJECT MANUAL. FAILURE BY CONSTRUCTION MANAGER F.V. FIELDVERIFY O.F.C.I. OWNER FURNISHED- FINISH SYSTEM JT. JOINT REF. REFERENCE CMP COMPOSITEMETALPANEL (� NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE ANY THE CONTRACTOR TO BECOME COMPLETELY FAMILIAR AND COGNIZANT CONTRACTOR INSTALLED TS # NUMBER E.J. EXPANSIONJOINT FINISH SYSTEM HVAC REFL. REFLECTED O.F.0.1. OWNER FURNISHED- T.W. CONTRACTOR FROM RESPONSIBILITY TO PROVIDE APPROPRIATE OF ALLASPECTS OF THE WORK SHALL NOT RELIEVE THE CONTRACTOR OF OF FINISH TO FACE OF FINISH. A CONCRETE MASONRY UNIT EL. ELEVATION L OWNER INSTALLED REINF. REINFORCED o QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, THE RESPONSIBILITY TO PROVIDE MATERIALS, ASSEMBLIES, OR SERVICES G.C. GENERAL CONTRACTOR O.H. OPPOSITEHAND ELEC. ELECTRIC/ELECTRICAL DEPARTMENT RESIL. RESILIENT CONCRETE 3' 01' r' INSTALLATION, ANCHORAGE AND COORDINATION WITH OTHER INDICATED IN THE CONTRACT DOCUMENTS. U A/C AIR CONDITIONING ELEV. ELEVATOR/ELEVATION L LENGTH R. H. RIGHT HAND OPPOSITE - 3' 6" 11-011 UNLESS NOTED OTHERWISE TRADES, ORWAIVE THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY C. CONT ACOUS. ACOUSTICAL ENGR. ENGINEER LAV. I RM ROOM 1' -0" WIDE/WIDTH AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THE B. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING: IN WALLS SUPPORTING CASEWORK, TACKBOARDS, K. A.C.T. ACOUSTICAL CEILINGTILELAVATORY E.P. ELECTRICALPANEL LB POUND R.O. ROUGH OPENING GRAB BARSCONTRACT WITH DOCUMENTS, OR WAIVE THE CONTRACTOR'S MARKERBOARDS, RESTROOM ACCESSORIES, ETC. ACP ACOUSTICAL CEILING PANEL EQ. EQUAL L.H. LEFTHAND INCANDESCENT GRAB BARS ' WATERCLOSET RESPONSIBILITY TO ALERT THE ARCHITECT TO ERRORS OR OMISSIONS ALLMATERIAL AND EQUIPMENT OF INDUSTRY STANDARD QUALITY, ADA AMERICANS W/DISABILITIES ACT EQUIP. EQUIPMENT L.L.H. LONG LEG HORIZONTAL S WD. WOOD CONTAINED THEREIN. SPECIFIED OR NOT, AND WITH THE LIMITATION OF THE CONTRACT D. SEAL ALLJOINTS BETWEEN DISSIMILAR MATERIALS. L. ADAAG AMERICANS W/DISABILITIES ACT E.W.C. ELECTRICWATERCOOLER L.L.O. LONG LEG OUT SCHED. SCHEDULE o TOILET PAPER DISPENSER WATERHEATER DOCUMENTS TO CAUSE THE INSTALLATION TO FUNCTION IN FRAME TYPICAL. ACCESSIBILITYGUIDELINES EXIST. EXISTING L.L.V. LONG LEGVERTICAL S.D. SOAP DISPENSER z W/0 WITHOUT CONTRACTOR SHALL VERIFY IN THE FIELD ALL EXISTING APPLICABLE ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED E. ALLGYPSUM WALLBOARD IS 5/8" TYPE "X" UNLESS NOTED ADJ. ADJUSTABLE EXP. EXPOSED DOWNSPOUT SECT. SECTION o v z 0 0 w CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS AND PROJECT. OTHERWISE. PROVIDE MOISTURE AND MOLD RESISTANT A/E ARCHITECT/ENGINEER EXT. EXTERIOR M S.F. SQUARE FEET 0 � a , " o x w x AS PERTINENT TO THE INTENT OF THESE DRAWINGS. ANY GYPSUM WALLBOARD IN APPARATUS BAY, JANITOR CLOSETS, A.F.F. ABOVE FINISHED FLOOR SHT. SHEET a � v � DISCREPANCY DISCOVERED SHALL BE BROUGHT TO THE ATTENTION ALLMATERIAL NECESSARY FOR EQUIPMENT TO FUNCTION IN A NORMAL RESTROOMS, LOCKER ROOMS AS WELL AS WET WALLS KITCHEN ALT. ALTERNATE F MAX. MAXIMUM SIM. SIMILAR C4 8" v OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANYWORK AND ACCEPTABLE MANNER. AND LAUNDRY ROOMS. ALUM. ALUMINUM F -R FIRE -RESISTIVE MB. MARKERBOARD SPEC. SPECIFICATION a - o v o AFFECTED BY, OR RELATED TO, SUCH DISCREPANCY. F. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT A.P. ACCESS PANEL FAB. FABRICATE/FABRICATOR M.C. MECHANICAL CONTRACTOR SQ. SQUARE � a a I `V ALLWORKREQUIRED TO CAUSE CONSTRACTOR'S OPERATIONS TO FIT INDIVIDUAL UNITS OF WORK AT INDUSTRY RECOGNIZED ARCH. ARCHITECT/ARCHITECTURAL F.C.U. FAN COIL UNIT M.D.F. MEDIUM DENSITY FIBERBOARD S.S. STAINLESS STEEL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED AND COORDINATE WITH OTHER TRADES. STANDARD MOUNTING HEIGHTS, ADA AND ANSI Al 17.1 FOR A.V. AUDIO/VISUAL F.D. FLOORDRAIN MECH. MECHANICAL% STD. STANDARD 171019" P-3" WITH, OR CAUSED BY FAILURE TO COMPLY WITH REQUIREMENT. THE PARTICULAR APPLICATION AND REFER QUESTIONABLE B F.E. FIRE EXTINGUISHER M.E.P. MECH./ELECT./PLUMBING ST L. STEEL LWALL-MOUNTED ALLWORK REQUIRED TO COMPLY WITH GOVERNING CODES WITH MOUNTING HEIGHT CHOICES TO ARCHITECT FOR FINAL F.E.C.FIRE EXTINGUISHER CABINET MFR. MANUFACTURER(ING) STOR. STORAGE SANITARY NAPKIN DISPOSAL--JCONTRACTOR SHALL REVIEW IN ADVANCE ALL PORTIONS OF THE RESPECT TO CONSTRACTOR'S ACTIVITY, EXCEPT FOR DESIGN CRITERIA DECISIONS. BD . BOARDM.H. F.F.E. FINISH FLOOR ELEVATION MANHOLE STRUCT. STRUCTURAL OR FLOOR PIPE INSULATION FOR WORK TO VERIFY THAT THE WORK WILL NOT PROHIBIT COMPLETION INVOLOVING CAPACITIES AND BASIC DESIGN. G. COORDINATE ENGINEERING DRAWINGS WITH ARCHITECTURAL BITUM. BITUMINOUS F.F.&E. FURNISHINGS, FIXTURES MIN. MINIMUM SUSP. SUSPEND(ED) MOUNTED WATER CLOSET ADA COMPLIANCE OF THE PROJECT AS INTENDED IN THESE CONTRACT DOCUMENTS. DRAWINGS AND FIELD CONDITIONS, AND REPORT BLDG. BUILDING AND EQUIPMENT MISC. MISCELLANEOUS SYM. SYMMETRICAL ANY QUESTIONS SHALL BE PROMPTLY REFERRED TO THE ARCHITECT WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE SIZING OF DISCREPANCIES IMMEDIATELY TO ARCHITECT. B/0 BOTTOM OF F.H.C. FIRE HOSE CABINET M.O. MASONRY OPENING T FOR RESOLUTION. INTERCONNECT FACILITIES, SUCH AS DUCTS AND WIRING IN PIECES OF H. CONFLICTS BETWEEN SPECIFICATIONS AND DRAWINGS SHALL BE B.O.W. BOTTOM OF WALL FIN. FINISH(ED) MTL. METAL EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE COMMUNICATED TO THE ARCHITECT FOR RESOLUTION PRIOR TO BSMT. BASEMENT FL FLOOR T. THICKNESS CONTRACTOR SHALL REFER TO THE PROJECT MANUAL FOR CLEANING EQUIPMENT. COMMENCEMENT OF THE WORK. C FLUOR. FLUORESCENT N T.B. TBD T ET TOO BBEE DETERMINED AND DISPOSAL REQUIREMENTS. Y TYPE CAB. CABINET F.O. FINISH OPENING N.A.F. NO APPLIEDFINISH T.C. TOP OF CURB ADA COMPLIANT FS ONE GYPSUM C.F.C.I. CONTRACTOR FURNISHED- F.O.B. FACE OF BLOCK N.I.C. NOT IN CONTRACT T.D. TOP OF DECK BOBRICK B-6806 SERIES 36", 42"AND 18" VERTICAL U.V. UNITVENTILATOR CONTRACTOR INSTALLED F.O.BR. FACE OF BRICK NO. NUMBER TECH. TECHNICAL SOAP DISPENSER BYOWNER VENDOR ADA COMPLIANT C.G. CORNERGUARD F.O.C. FACE OF CONCRETE N.T.S. NOT TO SCALE TEL. TELEPHONE T7 SHOWER ROD 48", HOOKS AND CURTAIN BOBRICK B-207 C.I.P. CAST -IN-PLACE F.O.F. FACE OF FINISH O BOBRICK B-6827 TEMP. TEMPORARY NOTED 7PLASTER ON METAL LATH STEEL, COPPER, CONDUIT OR EMT CJ. CONTROLJOINT F.O.G. FACE OF GYPSUM BD. W/AB/PVC INSULATION T&G TONGUE AND GROOVE HARDWARE PR. PAIR CL. CENTERLINE F.O.S. FACE OF STUD O.A. OVERALL T.M. TOP OF MASONRY (SLEEVED OR UNSLEEVED) C.W. COLDWATER CLG. CEILING FPRF. FIREPROOF O.C. ON CENTER TMPRD. TEMPERED B. ALLDIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL DRAWINGS. CLR CLEARANCE) FT. FOOT/FEET O.D. OUTSIDE DIAMETER T/0 TOPOF VERT. VERTICAL C.M. CONSTRUCTION MANAGER F.V. FIELDVERIFY O.F.C.I. OWNER FURNISHED- T.P. TOP OF PAVEMENT HT. HEATING, VENTILATION& PTD. CMP COMPOSITEMETALPANEL (� CONTRACTOR INSTALLED TS TOP OF STEEL FINISH SYSTEM HVAC A.C. PWD. O.F.0.1. OWNER FURNISHED- T.W. TOPOFWALL OF FINISH TO FACE OF FINISH. C.M.U. CONCRETE MASONRY UNIT GA. GAUGE OWNER INSTALLED TYP. TYPICAL COL. COLUMN G.C. GENERAL CONTRACTOR O.H. OPPOSITEHAND DEPT. DEPARTMENT CONC. CONCRETE GEN. GENERAL OPG. OPENING U CONST. CONSTRUCTION GL. GLASS OPP. OPPOSITE U.N.O. UNLESS NOTED OTHERWISE C. CONT CONTINUOUS G.W.B./GWB GYPSUMWALLBOARD P DETAIL GFOUNTAIN I SPECIALTY ACCESSORY SCHEDULE TYPE ITEM MFR/MODEL REMARKS PROVIDED BY INSTALLED BY T1 TOILET PAPER DISPENSER BOBRICK B-2888 ADA COMPLIANT FS ONE GYPSUM T2 SANITARY NAPKIN DISPOSAL BOBRICK B-254 FS ONE CONTR. CONTRACTOR T3 GRAB BARS (3 PIECE) BOBRICK B-6806 SERIES 36", 42"AND 18" VERTICAL U.V. UNITVENTILATOR T4 RECESSED PAPER TOWELDISPENSER/ WASTE RECEPTACLE BOBRICK B-369 STEEL, COPPER, CONDUIT OR EMT 4 HR WL 1 1 10 T5 SOAP DISPENSER BYOWNER VENDOR ADA COMPLIANT HEIGHT P. LAM T6 TOWEL HOOK BOBRICK B-6827 NOTE: REFERTO PROJECT MANUAL FOR COMPLETETOILETACCESSORYSPECIFICATIONS. IN A SLEEVE A. T7 SHOWER ROD 48", HOOKS AND CURTAIN BOBRICK B-207 B204-1 AND B204-3 C.T. CERAMICTILE T8 MOP HOOK BOBRICK B-6827 PLASTER O NOTED WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL STANDARDS ESTABLISHED BYTHE RECOGNIZED TRADE ASSOCIATION SURFACES AND FINISHES AT INTERIOR AND EXTERIOR OF BUILDING. HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT DAMAGED SURFACES AND FINISHES RESULTING FROM THE SHALL GOVERN THE WORK. PERFORMANCE OF THE WORK SHALL BE REPAIRED AT NO COST TO THE OWNER BYTHE RESPONSIBLE CONTRACTOR TO MATCH EXISTING TO ALL UNSPECIFIED FIXTURES, ACCESSORIES AND / OR EQUIPMENT THE SATISFACTION OF THE OWNER. PROVIDED BYTHE CONTRACTOR SHALL HAVE CUT SHEETS/ DRAWINGS SUBMITTED TO THE ARCHITECT FOR APPROVAL. GENERAL PLAN NOTES 7� VINYL SIDING -MATCH EXISTING MEMBRANEAIR BARRIER -SHOWN DASHED 1/2" PLYWOOD INSULATION 6" METAL STUD CONCRETE OR CONCRETE BLOCK STEEL, COPPER, CONDUIT OR EMT (SLEEVED OR UNSLEEVED) 3 HR CAJ 1155 FS -ONE CAJ 1226 FS ONE PLYWOOD UTIL. UTILIT WJ 1042 FS ONE GYPSUM STEEL, COPPER, CONDUIT OR EMT 1 OR 2 HR WL 1054 FS ONE CONTR. CONTRACTOR H WL 1085 P.L. PROPERTYLINE U.V. UNITVENTILATOR WL 1058 FS ONE SHOWN ON ROLLED SHAPE STEEL, COPPER, CONDUIT OR EMT 4 HR WL 1 1 10 FS ONE COOK. CPT. COORDINATE CARPET H. HEIGHT P. LAM PLASTICLAMINATE - - GLASS FIBER REINFORCED ✓� r✓"-� RIGID INSULATION: THERMAL, ACOUSTICAL, OR SAFING NOTE: REFERTO PROJECT MANUAL FOR COMPLETETOILETACCESSORYSPECIFICATIONS. IN A SLEEVE A. DO NOT SCALE THE DRAWINGS. REFER DISCREPANCIES TO I. SUPPLY, COORDINATE, AND INSTALL ACCESS DOORS, PANELS GYPSUM STEEL, COPPER, CONDUIT OR EMT C.T. CERAMICTILE HB HOSE BIBB PLAS. PLASTER O NOTED 7PLASTER ON METAL LATH STEEL, COPPER, CONDUIT OR EMT 1 OR 2 HR ARCHITECT FOR FINALDECISIONS. AND HATCHES IN CEILINGS, WALLS, AND FLOORS; AND NOTIFY W/AB/PVC INSULATION HDWR. HARDWARE PR. PAIR V FS ONE W/ GLASSFIBER INSULATION ARCHITECT OF ANY CONFLICTS WITH FEATURES SHOWN ON (SLEEVED OR UNSLEEVED) C.W. COLDWATER H.M. HOLLOWMETAL PREFAB. PREFABRICATED V.C.T. VERTICALNYL COMPOSITION TILE PIPE W/ GLASSFIBER INSULATION B. ALLDIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL DRAWINGS. IN A SLEEVE D HORIZ. HORIZONTAL PT. BD. PARTICLEBOARD VERT. VERTICAL UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS D.E.F.S. DIRECT EXTERIOR HT. HEATING, VENTILATION& PTD. PAINTED VEST. VESTIBULE "CLR OR "CLEAR" INDICATE A CLEAR DIMENSION FROM FACE J. PROVIDE WATER ROUGH -IN AND ELECTRICALCONNECTIONS FINISH SYSTEM HVAC A.C. PWD. PLYWOOD VIF VERIFYIN FIELD OF FINISH TO FACE OF FINISH. FOR OWNER -PROVIDED EQUIPMENT IN COMPLIANCE WITH MEP H.W. HOT WATER O' DRAWINGS. DEPT. DEPARTMENT W DET. DETAIL Q.T. QUARRYTILE C. PROVIDE BRACING AND WOOD BLOCKING AS REQUIRED D.F. DETAIL GFOUNTAIN I W WIDE/WIDTH IN WALLS SUPPORTING CASEWORK, TACKBOARDS, K. PROVIDE SLIP CHANNELS AT ALL LOCATIONS WHERE WALLS DIA. DIAMETER I.D. INSIDE DIAMETER W/ WITH MARKERBOARDS, RESTROOM ACCESSORIES, ETC. EXTEND TO A STRUCTURAL MEMBER ABOVE. DIM. DIMENSION INCAN. INCANDESCENT W.C. WATERCLOSET DIM. DISPENSER INFO. INFORMATION WD. WOOD D. SEAL ALLJOINTS BETWEEN DISSIMILAR MATERIALS. L. DOORS ARE TO BE INSTALLED 4" FROM CORNER TO EDGE OF D.M.B. DRYMARKERBOARD INSUL. INSULATION W.H. WATERHEATER FRAME TYPICAL. DN DOWN INT. INTERIOR W/0 WITHOUT E. ALLGYPSUM WALLBOARD IS 5/8" TYPE "X" UNLESS NOTED DS DOWNSPOUT WT. WEIGHT OTHERWISE. PROVIDE MOISTURE AND MOLD RESISTANT DWG. DRAWING W.W.F. WELDEDWIRE FABRIC GYPSUM WALLBOARD IN APPARATUS BAY, JANITOR CLOSETS, RESTROOMS, LOCKER ROOMS AS WELL AS WET WALLS KITCHEN AND LAUNDRY ROOMS. F. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT INDIVIDUAL UNITS OF WORK AT INDUSTRY RECOGNIZED STANDARD MOUNTING HEIGHTS, ADA AND ANSI Al 17.1 FOR THE PARTICULAR APPLICATION AND REFER QUESTIONABLE MOUNTING HEIGHT CHOICES TO ARCHITECT FOR FINAL DECISIONS. G. COORDINATE ENGINEERING DRAWINGS WITH ARCHITECTURAL DRAWINGS AND FIELD CONDITIONS, AND REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT. H. CONFLICTS BETWEEN SPECIFICATIONS AND DRAWINGS SHALL BE COMMUNICATED TO THE ARCHITECT FOR RESOLUTION PRIOR TO COMMENCEMENT OF THE WORK. EXTERIORWALL TYPES SCHEDULE FIRE STOPPING SCHEDULE AND DETAILS MATERIALS LEGEND NOTE: PATTERNS SHOWN REPRESENT CUT MATERIALS IN PLAN OR SECTION, UNLESS NOTED OTHERWISE BELOW. UL SYSTEM BASIS OF DESIGN EARTH ® ACOUSTICAL CEILING TILE WOOD FRAMING/ BLOCKING: BASE MATERIAL PENETRATING ITEM FIRE RATING NO. HILTI PRODUCT CONTINOUS METAL PIPE 7� VINYL SIDING -MATCH EXISTING MEMBRANEAIR BARRIER -SHOWN DASHED 1/2" PLYWOOD INSULATION 6" METAL STUD CONCRETE OR CONCRETE BLOCK STEEL, COPPER, CONDUIT OR EMT (SLEEVED OR UNSLEEVED) 3 HR CAJ 1155 FS -ONE CAJ 1226 FS ONE PLYWOOD STEEL, COPPER, CONDUIT OR EMT 4 HR WJ 1042 FS ONE GYPSUM STEEL, COPPER, CONDUIT OR EMT 1 OR 2 HR WL 1054 FS ONE 3HR STEEL, COPPER, CONDUIT OR EMT 1 OR 2 HR WL 1085 FS ONE MEMBRANE: WATERPROOF, STEEL, COPPER, CONDUIT OR EMT (SLEEVED) 2 HR WL 1058 FS ONE SHOWN ON ROLLED SHAPE STEEL, COPPER, CONDUIT OR EMT 4 HR WL 1 1 10 FS ONE GRANULAR FILL ® RESINOUS FLOORING: WOOD SHIM TERRAZO, TROWEL -ON, UNO SAND, GROUT TILE: CERAMIC, QUARRY, UNO FINISHED WOOD AS NOTED SHOWN CUT AND ELEVATION CAST -IN-PLACE CONCRETE CARPET, CARPET TILE (DETAIL) ENGINEERED WOOD: GLUE LAMINATED PRECAST CONCRETE, GRATING WOOD FLOOR, WOOD INSULATED METALPIPES CAST STONE SHOWN IN PLAN SHINGLES, OR SIDING CONCRETE OR STEEL, COPPER, CONDUIT OR EMT 2 HR CAJ 5091 FS ONE CONCRETE BLOCK W/ GLASSFIBER INSULATION PLYWOOD BLOCK CP 642 (SMALL SCALE) (SLEEVED OR UNSLEEVED) GYPSUM GYPSUM WALL TO METAL DECK ® INSULATED GLASS: EIFS STEEL, COPPER, CONDUIT OR EMT 3HR CAJ 5090 FS ONE HWD-1011 W/AB/PVC INSULATION MEMBRANE: WATERPROOF, (TOP OF WALLTO FLOOR) 1 OR 2 HR HWD-1003/-1011 (SLEEVED OR UNSLEEVED) SHOWN ON ROLLED SHAPE WL 2078 METAL: TYPE AS NOTED AIR BARRIER SYSTEM STEEL, COPPER, CONDUIT OR EMT 4 HR WJ 5029 FS ONE ACOUSTICAL, UNO PIPE W/ GLASSFIBER INSULATION METAL: ROLLED SHAPES - - GLASS FIBER REINFORCED ✓� r✓"-� RIGID INSULATION: THERMAL, ACOUSTICAL, OR SAFING IN A SLEEVE CONCRETE SIDING OR TRIM O 10 GYPSUM STEEL, COPPER, CONDUIT OR EMT 1 OR 2 HR WL 5029 FS ONE SHEATHING: GYPSUM, OR AS W/ GLASSFIBER INSULATION O NOTED 7PLASTER ON METAL LATH STEEL, COPPER, CONDUIT OR EMT 1 OR 2 HR WL 5028 FS ONE W/AB/PVC INSULATION STEEL, COPPER, CONDUIT OR EMT 1 OR 2 HR WL 5025 FS ONE W/ GLASSFIBER INSULATION W/ COLLAR (SLEEVED OR UNSLEEVED) STEEL, COPPER, CONDUIT OR EMT 4 HR WL 5073 FS ONE PIPE W/ GLASSFIBER INSULATION IN A SLEEVE JOINTS CONCRETE OR CONCRETE BLOCKWALL TO METAL 2 HR HWD-0008 FS ONE CONCRETE DECK (TOP OF WALL) BRICK MASONRY INSULATED GLASS: PLYWOOD BLOCK CP 642 (SMALL SCALE) GLASS PIPE GYPSUM GYPSUM WALL TO METAL DECK ® INSULATED GLASS: EIFS MAX 6" PVC, CPVC, ABS, FRPP (IN A SLEEVE) /l MARBLE OR AS NOTED (TOP OF WALL TO ROOF) D13/A601 1 OR 2 HR HWD-1011 CP 601 OR MEMBRANE: WATERPROOF, (TOP OF WALLTO FLOOR) 1 OR 2 HR HWD-1003/-1011 FS ONE PLASTIC & GLASS PIPE SYMBOLS LEGEND CONCRETE OR CONCRETE MASONRY UNIT ® GRATING PARTICLEBOARD FS ONE BRICK MASONRY INSULATED GLASS: PLYWOOD CAJ 2109 CP 642 (SMALL SCALE) GLASS PIPE 3 HR STONE: LIMESTONE, GRANITE, ® INSULATED GLASS: EIFS MAX 6" PVC, CPVC, ABS, FRPP (IN A SLEEVE) /l MARBLE OR AS NOTED (DETAIL) CP 642 GYPSUM TERRA COTTA, STRUCTURAL MEMBRANE: WATERPROOF, SPRAYED FIREPROOFING FS ONE CLAY TILE ROOF, DAMPPROOFING SHOWN ON ROLLED SHAPE WL 2078 METAL: TYPE AS NOTED AIR BARRIER SYSTEM BATT INSULATION: THERMAL OR U ACOUSTICAL, UNO METAL: ROLLED SHAPES - - GLASS FIBER REINFORCED ✓� r✓"-� RIGID INSULATION: THERMAL, ACOUSTICAL, OR SAFING s CONCRETE SIDING OR TRIM O 10 Z GYPSUM WALL BOARD O SHEATHING: GYPSUM, OR AS O NOTED 7PLASTER ON METAL LATH PLASTIC & GLASS PIPE SYMBOLS LEGEND CONCRETE OR PVC, CPVC (CLOSED SYSTEM ONLY) 3 HR CAJ 214 1 FS ONE CONCRETE BLOCK PVC, CPVC, ABS, FRPP 3 HR CAJ 2109 CP 642 GLASS PIPE 3 HR CAJ 21 18 FS ONE MAX 6" PVC, CPVC, ABS, FRPP (IN A SLEEVE) 3 HR CAJ 21 10 CP 642 GYPSUM PVC, CPVC (CLOSED SYSTEM ONLY) 1 OR 2 HR WL 2098 FS ONE LU PVC, CPVC, ABS, FRPP (CLOSED SYSTEM ONLY) 1 OR 2 HR WL 2078 CP 642 WL 2075 FS ONE SIM DETAIL CALLOUT 1 DETAIL NUMBER DOOR ID NUMBER ► CONTROLJOINT A101 SHEET NUMBER REFER TO DOOR SHEDULE SHEET (ELEVATION VIEWS) ROOM TAG SEALAND AND BACKER ROD Room Name —ROOM NAME (DETAIL VIEWS) EXTERIOR ELEVATION TAG XXXX ROOM NUMBER 5/8 GYP. BASIS OF DESIGN: HILTI CONSTRUCTION CHEMICALS, INC. 1 ELEVATION NUMBER APPROVED EQUALS: PRODUCT OF EQUIVALENT CHARACTERISTICS UL COMPLIANT WITH UL 1479AND UL 2079, ASTM E 1339. CEILING TAG ACEILING TYPE A1101 SHEET NUMBER KEYED NOTE / PLAN NOTE M�::::CEI BRICK SILL � INTERIOR ELEVATION TAG LING HEIGHT 1/ A101 � SHEET NUMBER DEMOLITION NOTE ELEVATION NUMBER GL -X GLAZING TYPE BRICK -MATCH EXISTING `_ WALLCONSTRUCTION SECTION MARKER NEW CONSTRUCTION v FIRE SEAL MATERIALAS 1 SIM SECTION NUMBER KIT OF PARTS NOTE EXISTING CONSTRUCTION REQUIREDFORFIRERATING00000.00 NOTE NUMBER DEMOLISHED CONSTRUCTION FILLINGANNULAR SPACE AlA101 SHEET NUMBER SPEC SECTION REFERENCE WINDOW TYPE WALL TAG TX TOILET ACCESSORY PENETRATINGITEM ATTRIBUTE li WALL TYPE FX FURNITU RE/EQUIPM ENT TAG WALL FINISH TAG (&O�L COLUMN GRID X DENOTES DIFFERENT WALL CIKIICU I (\/`ATIf—\KI RELEAS O FOR CONSTRUCTION BRICK/ VINYL SIDING ON METAL STUD. WA L L PE N ETRATI O N Smhlect D eamipIlianice with all regulatiims if State and Local Cradles SCALE: 1" = P-0" DATE: 04/13/18 Nick Mishler 61 8 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h. c o m Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarilyindicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. DRAWN BY REG CHECKED BY DATE ISSUED 02/28/201 8 REVISIONS: # DESCRIPTION DATE Owner: Tela mon Corporation 1000 E 116th St Carmel, IN 46032 317 818-6888 Construction Manager: Capitol Construction 11051 Village Square Lane Fishers, IN 46038 317 574-5488 Electrical Engineer: Crew Corp 7768 Zionsville Rd # 150 Indianapolis, IN 46268 PH 317 713-7777 Mechanical Engineer: Swift Air Mechanical, Inc. 4537 N Franklin Rd Indianapolis, IN 46226 PH 317 547-5355 Plumbing Engineer: Bell Plumbing Service Suite 400 Greenwood, IN 46143 PH 317 886-7220 Z EI FIRE RATING REF. DESIGN No. R -VALUE U -VALUE 0 Q 19.21 0.052 RELEAS O FOR CONSTRUCTION BRICK/ VINYL SIDING ON METAL STUD. WA L L PE N ETRATI O N Smhlect D eamipIlianice with all regulatiims if State and Local Cradles SCALE: 1" = P-0" DATE: 04/13/18 Nick Mishler 61 8 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h. c o m Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarilyindicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. DRAWN BY REG CHECKED BY DATE ISSUED 02/28/201 8 REVISIONS: # DESCRIPTION DATE Owner: Tela mon Corporation 1000 E 116th St Carmel, IN 46032 317 818-6888 Construction Manager: Capitol Construction 11051 Village Square Lane Fishers, IN 46038 317 574-5488 Electrical Engineer: Crew Corp 7768 Zionsville Rd # 150 Indianapolis, IN 46268 PH 317 713-7777 Mechanical Engineer: Swift Air Mechanical, Inc. 4537 N Franklin Rd Indianapolis, IN 46226 PH 317 547-5355 Plumbing Engineer: Bell Plumbing Service Suite 400 Greenwood, IN 46143 PH 317 886-7220 D R E �4jG�i GISTER �O <- No. �O ti 1 Q AR -19400087 � STATE of NDIANP 4 GENERAL NOTES, SYM BO LS, LEGENDS AND EXTERIOR WALLS A001 PROJECT NUM BER: 16095 Z N OM 0 Q O 7 L_ Z LU C O L LU U � s O 10 Z r__r— O LU O QO O W D R E �4jG�i GISTER �O <- No. �O ti 1 Q AR -19400087 � STATE of NDIANP 4 GENERAL NOTES, SYM BO LS, LEGENDS AND EXTERIOR WALLS A001 PROJECT NUM BER: 16095