HomeMy WebLinkAboutTelamon Office Renovation_Architectural Drawings_Updated 13RELEASED FOR CONSTRUCTION
p SuhlecttDeampIlianicewith all regulatiims
I
if State and (Local Cudles
intro DATE: 04/13/18
Nick Mishler
01
FIRST FLOOR REFLECTED CEILING
PLAN
SCALE: 1/8" = 1'-0"
C,
C
GENERAL CEILING PLAN NOTES
A. REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS.
B. ALL GRIDS ARE CENTERED IN ROOMS EACH DIRECTION UNLESS
101-1 1/21, NOTED OTHERWISE.
C,
TYPICAL WOOD CLOUD -
nO) ENLARGED RCP
V ` SCALE: 1/2" = 1'-0"
TY P.
0 #1 WOOD CLOUD DETAIL
SCALE: 1" = 1'-0"
GYPSUMWALLBOARD
5/8" FURRING, MATCH STAIN TO WOOD
STAINED POPLAF
REFERTO RCP FOR HEIGHT
CEILING TRANSITION DETAIL -
0SOCIAL PORTAL 1
4SCALE: 1" = 1'-0"
GYPSUMWALLBOA
5/8" FURRI
REFERTO RCP FOR HEIG1 ,
GYP. CEILING
REFERTO RCP FOR HEIGHT
ALLBOARD
., „ —
Pi
CEILING TRANSITION DETAIL -
0SOCIAL PORTAL 2
5`% SCALE: 1" = 1'-0"
O
C. LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT BORDERS
CONTAIN NOT LESS THAN 1/2 TILE WIDTH, UNLESS OTHERWISE
INDICATED.
D. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN
INDIVIDUAL CEILING PANELS, SUCH AS SPRINKLER HEADS, DIFFUSERS,
LIGHT FIXTURES, ETC., UNLESS OTHERWISE INDICATED.
E. PAINT ALL EXPOSED GYPSUM WALLBOARD SURFACES UNLESS NOTED
OTHERWISE. REFER TO FINISH PLAN FOR COLORS.
F. ALL EXPOSED DUCTWORK, PIPING, CONDUITS ETC. SHALL BE PAINTED
COLOR TO MATCH CEILING OR EXPOSED STRUCTURE UNLESS
OTHERWISE NOTED.
G. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD CEILINGS AT 20'
MAXIMUM. VERIFY LOCATIONS WITH ARCHITECT PRIOR TO
INSTALLATION.
H. COORDINATE REFLECTED CEILING PLAN WITH MECHANICAL,
PLUMBING, ELECTRICAL, AND LIFE SAFETY PLANS. PROVIDE
COORDINATION DRAWINGS FOR REVIEW PRIOR TO CEILING
INSTALLATION.
LIGHT FIXTURES, SPRINKLER HEADS, HVAC SUPPLY AND RETURN GRILLES
ARE SHOWN FOR LOCATION ONLY. REFER TO MEP DRAWINGS FOR
ADDITIONALINFO.
J. PROVIDE ACOUSTICAL CEILING HOLD-DOWN CLIPS IN VESTIBULES. IN
ROOMS WITH EXTERIOR ENTRANCE DOORS PROVIDE HOLD-DOWN
CLIPS FOR 10' IN ALL DIRECTION OF DOORWAY.
CEILING LEGEND
2 x 2 LAY -IN CEILING GRID
4 x 4 LAY -IN CEILING GRID
GYPSUM BOARD CEILING
OR GYPSUM BOARD BULKHEAD
EXPOSED STRUCTURE
CEILING TAG CEILING TYPE—
CEILING
YPE CEILING HEIGHT
CEILING TYPES
TYPE
DESCRIPTION
A
ACOUSTICAL CEILING. MATCH EXISTING.
N
B
GYPSUM WALLBOARD CEILING ON GRID SUSPENSION SYSTEM.
REFER TO FINISH PLAN FOR PAINTING.
C CUSTOM WOOD CEILING.
D NO CEILING IN THIS ROOM - PAINTED EXPOSED STRUCTURE.
E
GYPSUM WALLBOARD BULKHEAD ON 3-5/8" INTERIOR METAL
FRAMING.
RETURN FACE OF DRYWALL TO CEILING OR STRUCTURE ABOVE.
REFER TO FINISH PLANS FOR PAINTING.
REFLECTED CEILING NOTES
1 2x6 STAINED POPLAR. USE CONCEALED FASTENERS.
2 2x4 STAINED POPLAR.
3 1x6 STAINED POPLARSTRONGBACK.
4 THREADEDROD. USE UNISTRUTSYSTEMIF NEEDEDTO CONNECTTOJOISTS ABOVE. RUN
RODSTHROUGH EXISTING ACOUSTICALTILETO STRUCTUREABOVE.
5 REMOVEEXISTINGLIGHTS ABOVE NEW WOOD CEILING. REPLACEWITHACOUSTICAL
CEILINGTILES.
6 REPAIR/REPLACETILESAS REQUIRED.
7 WOOD CEILING. SEE DETAIL 14/A603 FOR DIMENSIONS.
8 EXISTING CEILING TO REMAIN. REPLACEDAMAGEDTILESAS REQUIRED.
9 RELOCATEEXISTING LIGHTINGAS REQUIRED.
10 CONTINUE FACE OF BULKHEADTO DECKABOVE.
61 8 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h. c o m
Scope Drawings
These drawings indicate the general scope of the project in
terms of architectural design concept, the dimensions of the
building, the major architectural elements and the type of
structural, mechanical and electrical systems. The drawings
do not necessarilyindicate or describe all work required for
full performance and completion of the requirements of the
contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items
required for the proper execution and completion of work.
DRAWN BY REG
CHECKED BY
DATE ISSUED 02/28/201 8
REVISIONS:
# DESCRIPTION DATE
Owner:
Telamon Corporation
1000 E 116th St
Carmel, IN 46032
317 818-6888
Construction Manager:
Capitol Construction
1 1051 Village Square Lane
Fishers, IN 46038
317 574-5488
Electrical Engineer:
Crew Corp
7768 Zionsville Rd # 150
Indianapolis, IN 46268
PH 3 1 7 713-7777
Mechanical Engineer:
Swift Air Mechanical, Inc.
4537 N Franklin Rd
Indianapolis, IN 46226
PH 3 1 7 547-5355
Plumbing Engineer:
Bell Plumbing Service
Suite 400
Greenwood, IN 46143
PH 317 886-7220
D R E �4jG�i
GASTER
�O <_ No.
z AR -19400087
�STATE OF
iy /ND ANP J
FIRST FLOOR
REFLECTED
CEILING PLAN
A401
PROJECT NUM BER: 16095
Z
N
OM
Q
10
�
O
7
UJ
O
L
E
W
U
O
V
U.
V)
LCL
s
O
10
Z
OLU
::E
0
Q
O
�
O
W
D R E �4jG�i
GASTER
�O <_ No.
z AR -19400087
�STATE OF
iy /ND ANP J
FIRST FLOOR
REFLECTED
CEILING PLAN
A401
PROJECT NUM BER: 16095