RELEASED FOR CONSTRUCTION
p SuhjecttDeamipIlianicewith all regulatiims
I
if State and Local Cudles
intro DATE: 04/13/18
Nick Mishler
SECOND FLOOR REFLECTED
1 CEILING PLAN
SCALE: 1/8" = 1'-0"
GENERAL CEILING PLAN NOTES
A. REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS.
B. ALL GRIDS ARE CENTERED IN ROOMS EACH DIRECTION UNLESS
NOTED OTHERWISE.
C. LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT BORDERS
CONTAIN NOT LESS THAN 1/2 TILE WIDTH, UNLESS OTHERWISE
INDICATED.
D. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN
INDIVIDUAL CEILING PANELS, SUCH AS SPRINKLER HEADS, DIFFUSERS,
LIGHT FIXTURES, ETC., UNLESS OTHERWISE INDICATED.
E. PAINT ALL EXPOSED GYPSUM WALLBOARD SURFACES UNLESS NOTED
OTHERWISE. REFER TO FINISH PLAN FOR COLORS.
F. ALL EXPOSED DUCTWORK, PIPING, CONDUITS ETC. SHALL BE PAINTED
COLOR TO MATCH CEILING OR EXPOSED STRUCTURE UNLESS
OTHERWISE NOTED.
G. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD CEILINGS AT 20'
MAXIMUM. VERIFY LOCATIONS WITH ARCHITECT PRIOR TO
INSTALLATION.
H. COORDINATE REFLECTED CEILING PLAN WITH MECHANICAL,
PLUMBING, ELECTRICAL, AND LIFE SAFETY PLANS. PROVIDE
COORDINATION DRAWINGS FOR REVIEW PRIOR TO CEILING
INSTALLATION.
LIGHT FIXTURES, SPRINKLER HEADS, HVACSUPPLY AND RETURN GRILLES
ARE SHOWN FOR LOCATION ONLY. REFER TO MEP DRAWINGS FOR
ADDITIONALINFO.
J. PROVIDE ACOUSTICAL CEILING HOLD-DOWN CLIPS IN VESTIBULES. IN
ROOMS WITH EXTERIOR ENTRANCE DOORS PROVIDE HOLD-DOWN
CLIPS FOR 10' IN ALLDIRECTION OF DOORWAY.
CEILING LEGEND
2 x 2 LAY -IN CEILING GRID
4 x 4 LAY -IN CEILING GRID
GYPSUM BOARD CEILING
OR GYPSUM BOARD BULKHEAD
EXPOSED STRUCTURE
CEILINGTAG CEILINGTYPE X
CEILING HEIGHT
CEILING TYPES
TYPE
DESCRIPTION
A
ACOUSTICAL CEILING. MATCH EXISTING.
N
B
GYPSUM WALLBOARD CEILING ON GRID SUSPENSION SYSTEM.
REFER TO FINISH PLAN FOR PAINTING.
co
C CUSTOM WOOD CEILING.
_
D NO CEILING IN THIS ROOM - PAINTED EXPOSED STRUCTURE.
E
GYPSUM WALLBOARD BULKHEAD ON 3-5/8" INTERIOR METAL
FRAMING.
RETURN FACE OF DRYWALL TO CEILING OR STRUCTURE ABOVE.
REFER TO FINISH PLANS FOR PAINTING.
REFLECTED CEILING NOTES
1 2x6 STAINED POPLAR. USE CONCEALED FASTENERS.
2 2x4 STAINED POPLAR.
3 1x6 STAINED POPLARSTRONGBACK.
4 THREADEDROD. USE UNISTRUT SYSTEM IF NEEDEDTO CONNECT TO JOISTS ABOVE. RUN
RODS THROUGH EXISTINGACOUSTICALTILETO STRUCTUREABOVE.
5 REMOVEEXISTINGLIGHTS ABOVENEWWOODCEILING. REPLACEWITHACOUSTICAL
CEILINGTILES.
6 REPAIR/REPLACETILES AS REQUIRED.
7 WOOD CEILING. SEE DETAIL 14/A603 FOR DIMENSIONS.
8 EXISTING CEILINGTO REMAIN. REPLACEDAMAGEDTILES AS REQUIRED.
9 RELOCATE EXISTING LIGHTINGAS REQUIRED.
10 CONTINUE FACE OF BULKHEADTO DECKABOVE.
61 8 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h. c o m
Scope Drawings
These drawings indicate the general scope of the project in
terms of architectural design concept, the dimensions of the
building, the major architectural elements and the type of
structural, mechanical and electrical systems. The drawings
do not necessarilyindicate or describe all work required for
full performance and completion of the requirements of the
contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items
required for the proper execution and completion of work.
DRAWN BY REG
CHECKED BY
DATE ISSUED 02/28/2018
REVISIONS:
# DESCRIPTION DATE
Owner:
Telamon Corporation
1000 E 116th St
Carmel, IN 46032
317 8 18-68 88
Construction Manager:
Capitol Construction
11051 Village Square Lane
Fishers, IN 46038
317 574-5488
Electrical Engineer:
Crew Corp
7768 Zionsville Rd # 150
Indianapolis, IN 46268
PH 317 713-7777
Mechanical Engineer:
Swift Air Mechanical, Inc.
4537 N Franklin Rd
Indianapolis, IN 46226
PH 3 17 547-5355
Plumbing Engineer:
Bell Plumbing Service
Suite 400
Greenwood, IN 46143
PH 317 886-7220
D R E �4jG�i
GISTER
�O <_ No.
z AR -19400087
�STATE OF
iy /ND ANP J
SECOND FLOOR
REFLECTED
CEILING PLAN
A402
PROJECT NUMBER: 1 6095
z
N
O
co
_
o
aNO
>
O
z-
zLU
O
L
E
uu
V
U.
�
U.
s
O
NO
z
r-
r—
Ow
::E
0
Q
O
�
O
W
D R E �4jG�i
GISTER
�O <_ No.
z AR -19400087
�STATE OF
iy /ND ANP J
SECOND FLOOR
REFLECTED
CEILING PLAN
A402
PROJECT NUMBER: 1 6095