HomeMy WebLinkAboutG002 - CODE REVIEW AND LIFE SAFETY PLAN (2)LIFE SAFETY PLAN LEGEND CODE SUMMARY APPLICABLE CODES INDICATES ONE-HOUR PLUMBING FIXTURE REQUIRED (PLUMBING OCCUPANT LOAD) Indiana General Administrative Rules RATED CONSTRUCTION Based on actuay occupant load: 50 Males 50 Females 2014 Indiana Building Code (2012 International Building Code with Indiana Ammendments) INDICATES TWO- HOUR 2014 Indiana Fire Code (2012 International Fire Code with Indiana RATED CONSTRUCTION Ammendments) 2012 Indiana Plumbing Code (2006 International Plumbing Code with Indiana Ammendments) -..... - INDICATES EGRESS PATH 2008 National Electrical Code (2008 NFPA 70) 2014 Indiana Mechanical Code (2012 International Mechanical Code with Indiana Ammendments) 2010 Indiana Energy Code (ASHRAE 90.1 2007) FEC INDICATES FIREF Americans with Disabilities Act Accessible Guidelines (ADAAG) for Buildings and EXTINGUISHER LOCATION Facilities erican nal Stan s Institut cessible Usable ' ings an cilities 6 1 8 East M a rke t Street OCCUPANT LOAD 1 Stan CAB I A11 - 09) Indianapolis, Indiana 46202 EGRESS CAPACITY TAG VARIANCE SCOPE OF PROJECT 24 A variance was filed (ID Number X 16139) for state approval for July Office renovation. phone 317264.8162 26 hearing to not require elements and spaces on the 2nd floor to a x i s a r C h . C o nl comply with accessibility requirements. OCCUPANCY CLASSIFICATION OCCUPANT CAPACITY B Occupancy (304.1) Scope Drawings CONSTRUCTION TYPE These drawings indicate the general scope of the project in Type VB- Permitted based upon allowable area and height for B occupancy terms oforchitectural design concept, the dimensions ofthe NUMBER OF OCCUPANTS OCCUPANCY TAG with area increases. See box to left. building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings SPACE FUNCTION FROMTABLE do not necessarilyindicateordescribe all work required for SPACE R B4-AREAOF full performance and completion of the requirements of the 1 004.1.1 contract. On the basis of the general scope indicated or B = Business/Office 240described, the trade contractors shall furnish all items S= Storage required for the proper execution and completion ofwork. M = Mechanical SPACE DRAWN BY Author A = Assembly (net or gross) CHECKED BY DATE ISSUED 02/28/201 8 RESIST EQUIR TS Fire resistive requirements based on Type VB construction are as follows: REVISIONS: # DESCRIPTION DATE 1 Building Elements Minimum Fire Resistance 116' 0" Beams 0 hour (Table 601) 1 ADDENDUM No. 1 3/30/18 Columns 0 hour (Table 601) Exterior bearing walls 0 hour (Table 601) Exterior non-bearing walls 0 hour > 10 ft. yard (Table 602) Interior bearing walls 0 hour (Table 601) Interior non-bearing walls Non-combustible (Table 601 and Sec. 602.2) Exterior parapet walls Not required (Sec. 704.11, Exception 1 and 6) • Exit access corridors 0 hour (Table 1018. 1) Floors 0 hour (Table 60 1) Exit stair enclosures Not Required (Sec. 1009.3, Exc. 1) • Note: Interior stair from basement to first floor • will be enclosed with 1 -hour fire barriers per i � • � section 1022. Shafts 1 hour (Sec. 707.4) Owner: / • Vertical openings: Telamon Corporation / b • • \ Protection of vertical Non-combustible items, including ducts, can 1000 E 116th St openings in non -rated penetrate two (2) floors with non -rated Carmel, IN 46032 / • floors assemblies and connect up to three (3) stories 317 818-6888 / without a shaft or damper. Annular space / • (between the floor and penetrating item) must / • be filled with non-combustible material to resist Construction Manager: / free passage of flame and products of Capitol Construction • 11051 Village Square Lane • combustion (Sec. 711. 4. 3. 1). Fishers, IN 46038 • Combustible items can penetrate only one (1) 317 574-5488 • non -rated floor assembly, and connect up to two • (2) stories without a shaft or damper. The annular Electrical Engineer: space between the floor penetrating item must be Crew Corp • filled with non-combustible materials to resist free 7768 Zionsville Rd # 150 • passage of flame and products of combustion Indianapolis, IN 46268 • (Sec. 711. 4. 3. 2). PH 317 713-7777 � Roof: • Roof deck fire resistance 0 hour (Table 601) / • Supporting members 0 hour (Table 601) Mechanical Engineer: / • Roof surfacing Class A, B, or C (Table 1505.1) Swift Air mechanical, Inc. Protection of openings: 4537 N Franklin Rd / • Exterior walls 0 hour (Table 704. 8) Indianapolis, IN 46226 • Vertical shafts 1 hour (Table 715. 4) PH 317 547-5355 • Incidental -use rooms Doors with closers (Sec. 508. 2. 2. 1) • Elevator and Equipment Room: The elevator shaft and machine room will be Plumbing Engineer: enclosed with 2 -hour construction in order to omit Bell Plumbing Service • sprinkler protection from these spaces. Suite 400 • (903.3.1.1.1) Greenwood, IN 46143 • PH 317 886-7220 • INCIDENTALUSE SEPARATIONS s Incidental use areas are required to be provided with smoke tight 4a sF • construction. Partitions shall extend from the floor to the underside of the STORAGE • floor, roof deck above, or tight ceiling. Doors shall be self-closing or 106 • automatic -closing upon detection of smoke. Air-transferopenings shall be • provided with smoke dampers. Duct work does not need to be dampered. =7�A(509.4.2) 25 ••••as I � FEC The following areas are considered incidental use areas: ( 270 • 25 (IBC Table 509). • Boiler and fuel equipment rooms over 400,000 BTUs/hour input. 120 Laundry rooms over 100 sq. ft. • U U U U • MENS ADA RESTROOMS- ESTROOM • OTHER SEPARATION 103 BREAK • z LOCKERS ROOM Electrical "Rooms" 1 KE 1 O • Electrical vaults > 600 volts 3 hour rating [IEC, Sec. 110. 31 (A)] N • 0 1170 Transformers O \ g • • • • • • • • • • • • • • • • Ai46o s a Dry type< 112-1/2 kVA Not required [IEC 450.21. (A)] CORRIDOR > 112-1/2 kVA 1 hour [IEC 4502. 1 (B)]; 10 \ • 101 See exception \ • WOMENS ° Vaults See section IEC 450.41 for exceptions O Z Switch gear -unenclosed In a vault following IEC 450.41 \ ADA RESTROOMS- RESTROOM Switch gear over 35,000 volts through 450.48; See IEC 230.212 \ z \ • W E • • • • • • • • • • • • • • • • • • • • • \ 0 ix L_ 25 0 • \ • 120 NUMBER OF EXITS W U S • • • • • • • • • • • • • • • • • • • • • • • • \• • • • • • • • • • • • 40 2 means of egress are required from rooms or areas with an occupant load '� V exceeding 50 or a common path of travel exceeding 100 feet. (1015.1) 25 # Exits U \ 270 Basement 1 U S \ CUSTODIAL First Floor 2 O } \ 105 Second Floor 2 10 198'-0" \ s OCCUPANT LOAD AND EGRESS CAPACITY z \ 48 SF See Occpancy Schedule this sheet for building occupant load \ � 0 LJ.J \ Total egress capacity provided exceed occupant load. Refer to plans this sheet. � 9 P YP P � O EGRESS CORRIDORS Egress corridors are not require to be fire rated based upon automatic sprinkler � O protection. (1018.1 ) U EGRESS TRAVEL DISTANCE Table 1016. 1, IBC limits the maximum travel distance in a sprinklered B occupancy to 300 feet. EXITING Doors serving an area required to have two (2) or more exits shall swing in the direction of egress travel (IBC, Sec. 1 008.1.2). DOOR SWING Doors serving an area required to have two (2) or more exits shall swing in the direction of egress travel (IBC, Sec. 1 008.1.2). PANIC HARDWARE ```GE���DfR��'i''''' Not required in a B occupancy. (1008. 1.10) a`11" �\STE _sQ AR -19490087 �g FIRE PROTECTIONS SYSTEMS =� TE s� STATE of *s Sprinklers Provide per NFPA 13 �� SND ANP Portable fire extinguishers Required per Carmel Indianal-ocal Code �i4�'YC I T C, � �n m Smoke detection Recommend interconnected smoke alarms in sleeping areas as a minimum Standpipes Are not required based upon the elevation of the 2nd floor level at less than 30 feet above grade CODE REVIEW 1) AND LIFE SAFETY Fire Alarm System Provided. See electrical dwgs for details. PLAN e D re re ' or utdo systems delivering in excess of 2000 CFM, and for elevator recall. (3003.2, 606.1 IMC) Exit signs Required (Sec. 1011. 1) RELEASED FOR CONSTRUCTION FIRST FLOOR LIFE SAFETY PLAN01 G002 Exit illumination Required (Sec. 1 006) d sae,ect DeamipIlianiaewithallregulatims SCALE: 3/32" = 1'-0" ti t Stag and (Local Cadies with emergency power PROJECT N UM BER: 1 6 0 9 5 mhro DATE: 04/13/18 Nick Mishler REQUIRED PROVIDED MALE FEMALE MALE FEMALE UNISEX WATER CLOSETS 2 2 5 3 2 URINALS 7 LAVATORIES 2 2 4 2 0 1 2 DRINKING FOUNTAIN SERVICE SINK 1 2