Loading...
HomeMy WebLinkAbout04100179 Building PlansARCHITECT: CSO 280 E. 96TH STREET, SUITE 200 INDIANAPOLIS, INDIANA 46240 (317) 848.7600 (377) 574.1869 FAX CONTRACTOR: �6i Duke REALTY CORPORATION 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317)808-6000 INDEX OF DRAWINGS 01 MILLWORK SHAM BE FABRICATED FROM FIELD MEASUREMENTS WITH 1 COVER 0 el 1.11 I A201 DEMOLITION CONSTRUCTION PLAN ol t i I A202 REFLECTED CEILING PLAN 91 12.1 A601 ELEVATIONS DETAILS • A801 FINISH PLAN • 1.12 E201 ELECTRICAL DATA PLAN C APPROVED AS SUBMITTED El APPROVED AS NOTED 1:1 REJECTED SIGNATURE DATE COMPANY 2ND FLOOR KEY PLAN SCALE: NTS NORTH HAMILTON CROSSING VI SPECIFICATIONS AND GENERAL NOTES MILLWORK SHAM BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 0 CONTRACT CONDITIONS 1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, t i CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION 0.1 THE GENERAL CONDITIONS SHAM BE AIA DOCUMENT A201 - 1987 EDITION, 12.1 EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE ENTITLED 'GENERAL CONDITIONS OF THE CONTRACT FOR PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. CONSTRUCTION'. THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF 1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED FOLLOWING: MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CAM FOR IN INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND AS FOLLOWS: THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE STRAIGHT WITH NO DISTORTIONS. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL 6.10 32 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND 1. FERROUS METAL PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. .3 YORKTOWNI CABINETS FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE WIDTH NOT TO EXCEED 1/8 U.O.N. A ACRYLIC SEMI -GLOSS ENAMEL FINISH: PROCEEDING WITH CONSTRUCTION. 2 DEMOLITION 1. PRIMER I COAT 141702 METALCIAD ACRYLIC SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE MECHANICAL AND ELECTRICAL OUTLETS. RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, 2.1 COORDINATE DEMOLITION WITH CONSTRUCTION PIANS TO DETERMINE METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND 7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 7 WORK. 2. NON-FERROUS METAL: "'"� 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING 2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, 7.1 WORKMANSHIP. 1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL 1�.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY AND FIXTURES: .1 DOW CORNING 786'; DOW CORNING CORP. TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING SEMI -GLOSS FINISH CONTRACTOR'S RESPONSIBILITY. INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND .2 .3 '863 #345 WHITE'; PECTORA CORP. 'PROGLAZE 3. FERROUS STRUCTURE 15/16.2 WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED 0.2 WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, A ACRYLIC DRY FOG FLAT FINISH: TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND RULES AND REGULATIONS. .5 SONN®ORN BUILDING PRODUCTS ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. 0.3 ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD 2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED REDUCIBLE ACRYLIC DRY FOG COATING QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF CERTIFIED ENGINEER. MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION 15/16.3 BE INCLUDED, IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED 2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS PROJECT. 'AC -20"; PECORA CORP. DRAWINGS. 0.4 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE 2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE 8. WOOD: SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED .3 .4 'TREMCO ACRYLIC LATEX 834"; TREMCO, INC. WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND SPECIFIED CAPACITIES OF THE EQUIPMENT. 1. PRIMER: 1 COAT 151701 WONDER -PRIME LATEX METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW 0.5 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS DOORS AND WINDOWS FINISHES. ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING 2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS GOVERN THE WORK. NOTED TO BE REPAIRED. 0.6 NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE 2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN 2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK PASTE WOOD FILLER (OPEN GRAIN WOODS). CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OWNER'S AGENT. IN SCOPE OF CONTRACT. DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S 2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING INTERPRETATION. ALKYD STAIN. DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS 0.7 INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS MANUFACTURER'S RECOMMENDATIONS. SHAM BE LARGE ENOUGH TO PREVENT THE HAUUNG/SPREADING OF DIRT 1 GENERAL REQUIREMENTS EQUIPMENT. THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. 4. FINISH: 2 COATS 14600 WONDER WOODSTAIN 2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES 1.1 WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS ALKYD SATIN VARNISH. AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE - 15/16.8 BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. 9.1 OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED 1.2 THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INSTALLED BY OTHERS UNLf SS OTHERWISE NOTED. CONTRACTOR SHALL CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO INCLUDING BUT NOT UNTIED TO TELEPHONE/DATA, SECURITY, FURNITURE DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS AND 'FURNISHED AND/OR INSTALLED" ITEMS. CONTRACTOR SHALL PRIMER -SEALER. PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AT CEILING. USE PREFORMED OUTSIDE CORNERS. CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A 'AS AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE RECORD SEPIA TO SERVE AS PART OF THE -BUILT' SET. LATEX SATIN ENAMEL WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR 2,11 PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE 'X' TAPERED REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. SETTLEMENT SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE 1.3 CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS) AND ADJACENT FACILITIES OR WORK TO REMAIN. ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND 5 METAL FABRICATIONS WORKMANSHIP. WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. 1.4 SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE 51 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED FOLLOWING ITEMS: 15/i6.11 OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS 1 METAL FABRICATIONS. TEXTURE COATING. = REQUIRED TO COMPLETE WORK. SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. 6 WOOD AND PLASTIC DOORS, FRAMES AND HARDWARE. MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA.- SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL "CONSTRUCTION 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND PANEL ). 61 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE .5 VCT FLOORING AND BASE (COLOR SAMPLES ). WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13 GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE CARPET {DYE LOT CUTTING AND SEAMING DIAGRAMS ). CONTENT. LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO PAINT ( 6' X 6' ON ACTUAL SURFACE ). P 6.2 PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE ' " _ ALLCOVERINGS (9" X 9" DYE LOT CUTTING ). EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA ACCEPTABLE, SIGNAGE ( SAMPLE SIGN ). C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32". .2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6' FROM 10 EIGHT FIXTURES ( CATALOG CUTS ). 6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND 1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL (TENS OUTSIDE CORNERS. PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA 1.5 TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH GENERAL NOTES TEMPORARY ENCLOSURES, ARE PROTECTION, HEAT AND POWER REFLECTED CEILING PLAN SHALL GOVERN, CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR JURISDICTION. THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING 6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S STANDARDS. 1.6 AGENT. THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND BUILDING STANDARD, PROVIDE JL INDUSTRIES 'AMBASSADOR" SERIES, .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR PROCEEDING WITH CONSTRUCTION. OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR TO FABRICATION OF MULTIPLE UNITS. 1'ri.2 SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT 6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. NEMA LD 3 AND GP -50 (0.050' NOMINAL THICKNESS). CASED OPENING UNLESS NOTED OTHERWISE THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES A TO FINISHED FACT OF GYPSUM BOARD, ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT 1 EDGE TREATMENT SAME AS LAMINATE CLADDING ON HORIZONTAL B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. ADDITIONAL CHARGE TO THE PARTY AFFECTED. .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET SURFACES. 2 PROVIDE 2' DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE 1.7 THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS D. TO BOTTOM OF FINISHED CEILINGS. ELECTRICAL OR DATA OUTLET LOCATIONS. CARPET. TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. 1.8 SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT 6.6 CABINETS: COMFY 44-01 SECTION 400 AND ITS DIVISION 4006 FOR SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, RESILIENT FLOORING: PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. SUBMIT THE FOLLOWING INFORMATION: GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED 1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOP'- .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF GP -50 (0.050' NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 .� PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. (0.028' NOMINAL THICKNESS); EDGES: GP -28 (0.028' NOMINAL DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO THICKNESS). PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28, CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, .3 CABINET HARDWARE SCHEDULE: .2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID ACCOMMODATE THE SUBSTITUTION. NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL 1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES' WITH CONSTRUCTION. AFFECT THE CONTRACT SUM AND CONTRACT TIME. ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. BY GRASS OR EQUAL GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4' ON 4'' LATER, 1.9 STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. 14483 OR EQUAL AS MANUFACTURED BY STANLEY. USE AN APPROVED CEMENTTTIOUS FILLER TO PATCH CRACKS, SMALL FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHEF WITH 1.10 THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHAM ARRANGE FOR MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS OBSERVATION. HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE SURFACE VARIATION OF 9" IN 10 FEET, NON -CUMULATIVE. MANUFACTURED BY STANLEY. GN.7 BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. LIMTFD TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; 11429 OR EQUAL AS 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING MANUFACTURED BY KNAPE Et VOGT. CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. STANDARDS: .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECT". 'i CLOSE -IN OF WALLS. MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED FLAMMABILITY: ASTM 2859 GN.9 SHELVING STANDARDS AS PRODUCED BY KNAPE k 'OGT SURFACE BURNING: ASTM E84 OR EQUAL SUITE 200 P CARMEL; INDIANA 6.7 MILLWORK SHAM BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 12 FURNISHINGS PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, t i 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, REINSTALL SUCH ITEMS. 12.1 CASEWORK: WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT 11 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE OPERATING FOR TEN DAYS. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOLLOWING: 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND FOR THE VARIOUS SUBSTRATES, AS INDICATED. .1 IMPERIAL CABINET CO., INC. STRAIGHT WITH NO DISTORTIONS. _ _ .2 MERILLAT INDUSTRIES, INC. 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM 1. FERROUS METAL ._ .3 YORKTOWNI CABINETS WIDTH NOT TO EXCEED 1/8 U.O.N. A ACRYLIC SEMI -GLOSS ENAMEL FINISH: 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL 1. PRIMER I COAT 141702 METALCIAD ACRYLIC 15/16 "., MECHANICAL AND ELECTRICAL OUTLETS. LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC 15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND SEMI -GLOSS ENAMEL ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE 7 JOINT SEALERS 2. NON-FERROUS METAL: "'"� ; ` RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS A ACRYLIC SEM( -GLOSS ENAMEL FINISH: ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS 1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC �: CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL AND FIXTURES: .1 DOW CORNING 786'; DOW CORNING CORP. LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, "SCS 1702 SANITARY'; GENERAL ELECTRIC CO. SEMI -GLOSS FINISH INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND .2 .3 '863 #345 WHITE'; PECTORA CORP. 'PROGLAZE 3. FERROUS STRUCTURE 15/16.2 ELECTRICAL SYSTEMS. GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF .4 WHITE'; TREMCO CORP. 'OMNIPLUS'; A ACRYLIC DRY FOG FLAT FINISH: DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND .5 SONN®ORN BUILDING PRODUCTS 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A REDUCIBLE ACRYLIC DRY FOG COATING CERTIFIED ENGINEER. 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING 4. NON-FERROUS STRUCTURE: 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S SURFACES: .1 'CHEM -CALK 600% BOS11K CONSTRUCTION PRODUCTS DIV. A ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS 'AC -20"; PECORA CORP. REDUCIBLE ACRYLIC DRY FOG COATING. DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) .2 SONOLAC ; SONNEBORN BUILDING PRODUCTS 8. WOOD: AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL .3 .4 'TREMCO ACRYLIC LATEX 834"; TREMCO, INC. A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: DRAWINGS SHALL GOVERN, NOTIFY ARCHITECT OF DISCREPANCIES AND OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 1. PRIMER: 1 COAT 151701 WONDER -PRIME LATEX 15/16.4 SUBMIT ARE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE 8 DOORS AND WINDOWS PRIMER -SEALER. OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS SEMI -GLOSS ENAMEL COORDINATE WITH OTHER CEILING COMPONENTS. NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. B. STAIN -VARNISH RUBBED FINISH: 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED 1. FILLER: 1 COAT #4800 WONDER WOODSTAIN SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. PASTE WOOD FILLER (OPEN GRAIN WOODS). OWNER'S AGENT. 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED AND LOCKSETS. ALKYD STAIN. WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 3. SEALER: 1 COAT 1490D WONDER WOODSEALER VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED REQUIREMENTS FOR HEAT -STRENGTHENED GLASS, QUICK DRY SEALER. EQUIPMENT. 4. FINISH: 2 COATS 14600 WONDER WOODSTAIN 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE, DIMMERS SHALL BE 9 FINISHES ALKYD SATIN VARNISH. GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. 10. GYPSUM WALLBOARD: 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. A. ACRYLIC LATEX SATIN ENAMEL FINISH: INSTALLED BY OTHERS UNLf SS OTHERWISE NOTED. CONTRACTOR SHALL 1. PRIMER: 1 COAT 150801 WONDER TONES LATEX COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND .1 INSTALL 'EUMINATOR' TYPE HEAD TRACK AT WALLS TERMINATING PRIMER -SEALER. TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE AT CEILING. USE PREFORMED OUTSIDE CORNERS. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC INSTALLATION SHALL OCCUR. LATEX SATIN ENAMEL 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF 9.2 GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE 'X' TAPERED 13, PRECAST CONCRETE: OUTLETS, UNLESS OTHERWISE NOTED. EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS) 15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE 1. PRIMER: 1 COAT 11502 WONDER -SHIELD ACRYLIC COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. LATEX HOUSE PAINT PRIMER. IVORY. 2. FINISH: 1 COAT 144101 DEV-VO-TEX LATEX 15/i6.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED TEXTURE COATING. = SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH PROVIDING PROPER ACCESS TO RECEPTACLES. MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA.- 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND 9,11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND FOR SPECIFIC LOCATION, FINISHING OF GYPSUM BOARD. WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO 9.4 COUNGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT ' " _ OBSERVE PRIOR TO ANY COMMENCEMENT OF "ROUGH -IN" DAMAGED OR SOILED TILES. ACCEPTABLE, C110N. .2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6' FROM 1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL (TENS OUTSIDE CORNERS. IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL GN GENERAL NOTES REFLECTED CEILING PLAN SHALL GOVERN, 10 SPECIALTIES .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS 10.1 FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO UNLESS NOTED OTHERWISE. BUILDING STANDARD, PROVIDE JL INDUSTRIES 'AMBASSADOR" SERIES, PROCEEDING WITH CONSTRUCTION. SEMI RECESSED, DUO -PANEL, FIELD PAINTED. 1'ri.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR CASED OPENING UNLESS NOTED OTHERWISE A TO FINISHED FACT OF GYPSUM BOARD, B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET C. TO TOP OF FINISHED FLOORS. MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH D. TO BOTTOM OF FINISHED CEILINGS. CARPET. GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, 9.6 RESILIENT FLOORING: EXISTING CONSTRUCTION AND WALL TYPES. GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS OTHERWISE ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO LOCATIONS DIMENSIONS AND TYPES DOOR AND WINDOW LOCATIONS AVOID USE OF CUT WIDTHS LESS THAN 3' AT ROOM PERIMETER. SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, .2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING WITH CONSTRUCTION. ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. 9.7 USE AN APPROVED CEMENTTTIOUS FILLER TO PATCH CRACKS, SMALL DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM OBSERVATION. SURFACE VARIATION OF 9" IN 10 FEET, NON -CUMULATIVE. GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMTFD TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4' IN 20'-0' NON - 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. STANDARDS: GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CLOSE -IN OF WALLS. FLAMMABILITY: ASTM 2859 GN.9 SOUND INSULATED AND ARE RATED PARTITIONING SHALL BE CAULKED AT SURFACE BURNING: ASTM E84 PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE. SMOKE DENSITY: ASTM E662 PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. SOUND ABSORPTION: ASTM C423 PROVIDE WITH SOUND ATTENUA iivG INSULATION SECURELY FASTENED FADE RESISTANCE: AATCC 16E TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL STATIC RESISTANCE: AATCC 134 JUNCTION BOXES ARE NOT PERMTTED. WARRANTY: 10 YEARS GN. O ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY CONTRACTOR. .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. F tiFSE� N S3, E u . 1,71 O tis y Oz7;r6'�',%'�;���� LCl F O� C. 0� < �U Zd .per � '� x'41'+ -,,,T, t .�, ,,,� ►�' � *:•, � � i.,-..� � �11n�,'��/� �� �^ ti=Ncuvnn03U »�'v1 j ~`fit, �f1�7'fi '-101 SNV'ld3S3Hu! CITY OF CARMEL/CLAY TOWNSHIP Dept. of Community Services -- Building & Code Enforcement One Civic Square I" Floor; Carmel, IN 46032 PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT rAs the authorized agent responsible for obtaining a permit or permits', I certify that these plans are IDENTICAL to those released for construction by the Indiana Depart. of Fire & Building Services. I also understand that if it is determined that these plans are not identical, a STOP WORK OR ER will be served, as required under the Ordinances referenced below. Authorized Signature Printed Name 'Required wider Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2 and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning Ordinance, Section 31.1 entitled "Violations and Penalties". u S:Permits/Forms/AuthentStickerll-Ill �.{-� '/ ca - [1 091Df� J STATf.o '9 !N 'ANO` .r 9/23/04 CSO #24198 a- t i ;- 7 h 4wl '� x'41'+ -,,,T, t .�, ,,,� ►�' � *:•, � � i.,-..� � �11n�,'��/� �� �^ ti=Ncuvnn03U »�'v1 j ~`fit, �f1�7'fi '-101 SNV'ld3S3Hu! CITY OF CARMEL/CLAY TOWNSHIP Dept. of Community Services -- Building & Code Enforcement One Civic Square I" Floor; Carmel, IN 46032 PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT rAs the authorized agent responsible for obtaining a permit or permits', I certify that these plans are IDENTICAL to those released for construction by the Indiana Depart. of Fire & Building Services. I also understand that if it is determined that these plans are not identical, a STOP WORK OR ER will be served, as required under the Ordinances referenced below. Authorized Signature Printed Name 'Required wider Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2 and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning Ordinance, Section 31.1 entitled "Violations and Penalties". u S:Permits/Forms/AuthentStickerll-Ill �.{-� '/ ca - [1 091Df� J STATf.o '9 !N 'ANO` .r 9/23/04 CSO #24198 GENERAL DEMOLITION NOTES: A. DEMOLISH EXISTING WALLS THAT ARE SHOWN DASHED, BACK TO A POINT WHEREAS A SMOOTH SURFACE REMAINS FOR INSTALLATION OF NEW FINISHES. B. REMOVE DOORS AND DOOR FRAMES AS SHOWN DASHED. RESERVE DOORS AND DOOR FRAMES FOR RE—USE IN NEW PROJECT SCOPE. C. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED. REFERENCE FINISH SHEET, A801, TO COORDINATE LOCATIONS OF NEW FINISHES D. SAVE ALL ITEMS REMOVED FROM THE SPACE PER OWNERS DIRECTION UNLESS OTHERWISE NOTED. 2ND FLOOR DEMOLITION/CONSTRUCTION PLAN .() SCALE: ,/s° = r -o° rpt►, DEMOLITION PLAN NOTES: D� REMOVE SECTION OF WALL AND PREP FOR NEW DOOR LOCATION. Ds REMOVE EXISTING TEMPORARY POWER OUTLETS. D3 REMOVE EXISTING WALL AND DOOR AND PREP FOR NEW HALLWAY. SAVE DOOR FOR RELOCATION AT NEW VACANCY, SEE CONSTRUCTION PLAN NOTE FP18. D4 REMOVE EXISTING DOOR AND FRAME. GENERAL CONSTRUCTION NOTES: A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER— DO NOT SCALE DRAWINGS. B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. C. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). D. REFER TO CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. E REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. F. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL G. APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. H. ALL WALLS SHALL BE CHAULKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION 1. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS J. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARTION FOR NEW FINISHES. K. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. L G.C. TO PROVIDE BUILDING STANDARD MINIBLINDS AT ALL PERIMETER WINDOWS. M. ALL NEW FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING TO CODE. UFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. N. EXISTING DOORS AND DOOR FRAMES TO BE REUSED DURING CONSTRUCTION DOORS THAT ARE QUESTIONABLE FOR REUSE, PLEASE CALL FOR DESIGNERS REVIEW AND APPROVAL OF REUSE BEFORE INSTALLATION. 0. ALL NEW WORKSURFACES TO RECEIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT T NEW ELECTRICAL LAYOUT ALTERNATES: 1. PRICE MOVEABLE PARTITION TO BE; XXX. INCLUDE STRUCTURAL SUPPORT AND DRYWALL ENCLOSURE AS REQUIRED. CONSTRUCTION PLAN NOTES: ALIGN FINISHED FACES. �rz CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/A601. �s CENTER WALL BETWEEN WINDOWS. �4 PROVIDE BLOCKING FOR OWNER SUPPLIED WHITEBOARD, VERIFY EXACT LCOATION WITH TENANT. PROVIDE BUILDING STANDARD COULMN WRAP. O EXISTING RECEPTION DESK, RELOCATED FROM TENANTS OLD SPACE. & COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL. �$ PROVIDE COAT ROD AND SHELF; REFERENCE DETAIL 3/A601. O PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER/REFRIGERATOR AND COFFEEMAKER. VERIFY EXACT LOCATION OF ALL APPLIANCES, REQUIRING A WATER SOURCE WITH TENANT. E3 G.C. TO INSTALL TENANT PROVIDED DISHWASHER. G.C. TO CONFIRM UNIT IS IN WORKING ORDER AND IS NOT LEAKING BEFORE TURNING UNIT OVER TO TENANT. E, REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER 19 VENDING MACHINES PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR VENDING MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL. E) PROVIDE 3(4" x 4' x 8' FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD. PAINTED WTH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH E) NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. E) PROVIDE MOVEABLE PARTITION TO BE: XXX INCLUDE STRUCTURAL SUPPORT AND DRYWALL ENCLOSURE AS REQUIRED. PRICE AS ALTERNATE. VERIFY EXISTING WALLS. ADD TO EXISTING WALLS AS REQUIRED TO MAKE A W4 WALL TYPE. E) PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED WATER COOLER. VERIFY EXACT LOCATION WITH TENANT. 6 RELOCATE DOOR, SEE DEMOLITION PLAN NOTE D3. WALL LEGEND: NOTES: ALL NEW WALLS TO BE W1 UNLESS NOTED OTHERWISE. _ _ = EXISTING CONSTRUCTION TO BE REMOVED EXISTING PARTITION TO REMAIN NEW WALL PARTITION W1 2-1/2" 25 GAUGE METAL STUDS ®24"O.C. WITH 5/8 GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. W2 2-1/2" 25 GAUGE METAL STUDS 024"O.C. WITH 5/8" GYPSUM WALL BOARD EACH M SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE 2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE CEILING AND INSIDE WALL INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL W3 2-1/2" 25 GAUGE METAL STUDS 024" O.C. co WITH 5/8" GYPSUM WALL BOARD ONE SIDE WALLS TO EXTEND TO UNDERSIDE OF CEILING. W4 2-1/2" 25 GAUGE METAL STUDS @16"O.C. 2 WITH TYPE "X" 5/8" GYPSUM WALL BOARD EACH SIDE WALLS TO EXTEND TO STRUCTURAL DECK 1—HR RATED ABOVE WALLS TO HAVE 1—HOUR RATING. UL DES. U465 W5 NEW WALL CONSTRUCTION TO MATCH ADJACENT PARTITION CONSTRUCTION. W6 NEW WALL CONSTRUCTION TO MATCH BUILDING STANDARD DEMISING WALL CONSTRUCTION. DENOTES AREA NOT IN CONTRACT DENOTES NEW MILLWORK FghNEW DOOR AND FRAME. REFER TO DOOR SCHEDULE Il REALTY ooRPORAnoN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone:317 808-6000 Fax: 317) 808-6797 D u' keFWL n co�orunoN East 96th Street 100 napolis, IN 46240 e: 317808-6000 317 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ocoffight 20DI in c 0 v � a � � Co >� V m W o W cn� o o v Z Q J >- a ZZ � Z a oCOQ V)0 J N006 Z W W U U w 0 SOW W �Q H = W J LL. W Ce _ TV. iQ.. _ alb .... NA:. ,C . `•` Drawing Number: A202 Of Sheets Duke Job Number: 0000 A/E Job Number: 24198 CD I (V TYPICAL WALL TYPE TYPICAL AT ALL EXTERIOR WALLS— 5/8" TYPE X G.W.B. FINISH BELOW EXISTING WINDOW SILL COVER METAL STUD PREFINISHED ALUMINUM RECEIVER TRIM "GB350". FASTEN AT WINDOW SILL & SET IN A CONTINUOUS BEAD OF ACOUSTICAL SEALANT. TRIM COLOR TO MATCH BLDG. WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT WINDOW 1 MULLION DETAIL A601 SCALE: NTS ADA SINK 4 BASE SECTION A601 SCALE: 1/2"=1'-O" BLOCKING AS REQUIRED SINK AND HARDWARE ABOVE RETRACTABLE HAEFLEE HARDWARE INDICATES DOOR IN RETRACTED POSITION ADJACENT CABINET RECESSED BASE LINE BELOW ARROW INDICATES DIRECTION DF MOVEMENT BY RECTACTABLE CABINET 4STRAGAL ON CABINET DOOR TOUCH LATCH HARDWARE ON NOTE: CABINET FRONTS SINK PIPES BELOW ARE TO BE WRAPPED FOR COMPLIANCE WITH ADA GUIDELINES. BREAKROOM 215 7 ELEVATION A601 SCALE: 1/2 -4 -0 - PLUMBING ISOMETRIC SCALE-- NTS TOP OF 1 1/2" LAMINATE BE AT BOTTOM EDGE OF 10'-1Y" 1 /2"HW, 1 /2"CW, & 1-1/4"V CONNECT TO BUILDING MAINS 2"W TO BUILDING DRAIN CONFERENCE 205" 10 ELEVATION A601 SCALE: 1/2"=1'-0' BUILDING STANDARD I i (TIMBERLAKE FAIRFIELD OAK DOOR TOFFEE) UPPER CABINETS / \ W/(2) ADJUSTABLE SHELV \ j/ — Q < W Q � OUTNER TO N 1:73W �t-20tH Y2(nCnnC��N� UONO ��ado���o 11 11 11 It II II II II CL c) m c��� n J Vl � U0�21in \ / PLASTIC LAMIN�E COUNTER 0 WINDOW SILL 36" A.F.F. WITO 1 1/20 EDGE RECEPTION & 4" BACKSPKH. I PL2 8'-0" REFRIGERATOR i i REFRIGERATOR i rWATER WD/GL PROVIDED i PROVIDED i i COOLER I WOOD I BY TENANT. } I BY TENANT. i I i I I PROVIDED I P/P,FL,DB,CL,S BY TENANT.1 203 BUILDING STANDARD 3'-0" (TIMBERLAKE tAIIIFIELD OAK 1 L�__,jj 4 TOFFEE) LO R �ABINETS J�� W/(1) ADJUiABLE SHELVES I AND 4" WIREIPULLS. I PROVIDED i I I I i I i I i I I I BY TENANT. U. L -------------J L -------------J I I 2'-9" 2'-9' 8'-0" CONFERENCE 205" 10 ELEVATION A601 SCALE: 1/2"=1'-0' BUILDING STANDARD I i (TIMBERLAKE FAIRFIELD OAK DOOR TOFFEE) UPPER CABINETS / \ W/(2) ADJUSTABLE SHELV \ AND 4" WIRE PULLS. — Q < W Q � \ / N 1:73W �t-20tH Y2(nCnnC��N� UONO ��ado���o 11 11 11 It II II II II CL c) m c��� n J Vl � U0�21in \ / PLASTIC LAMIN�E COUNTER 0 Y U h— 36" A.F.F. WITO 1 1/20 EDGE RECEPTION & 4" BACKSPKH. I PL2 8'-0" REFRIGERATOR i i REFRIGERATOR i rWATER WD/GL PROVIDED i PROVIDED i i COOLER I WOOD I BY TENANT. } I BY TENANT. i I i I I PROVIDED I P/P,FL,DB,CL,S BY TENANT.1 203 BUILDING STANDARD 3'-0" (TIMBERLAKE tAIIIFIELD OAK 1 ` 4 TOFFEE) LO R �ABINETS DISHWASHER W/(1) ADJUiABLE SHELVES I AND 4" WIREIPULLS. I PROVIDED i I I I i I i I i I I I BY TENANT. U. L -------------J L -------------J I I FILE ROOM BUILDING STANDARD (TIMBERLAKE FAIRFIELD OAK TOFFEE) UPPER CABINETS W/(2) ADJUSTABLE SHELVES -- AND 4" WIRE PULLS. I N PLASTIC LAMINATE COUNTER 0 36" A.F.F. WITH 1 1/2" EDGE & 4" BACKSPLASH. PL1 BUILDING STANDARD (TIMBERLAKE FAIRFIELD OAK TOFFEE) LOWER CABINETS W/(1) ADJUSTABLE SHELVES AND 4" WIRE PULLS. COFFEE AREA 201 g ELEVATION A601 J SCALE: 1/2"=1'-0" STAINLESS STEEL SINGLE BOWL SINK W/ GOOSENECK FAUCET AND PADDLE LEVERS. L:a 7C— t —� = 7—L r,--------- REFRIGERATOR STAINLESS STEEL SINGLE PROVIDED BOWL SINK W/ GOOSENECK BY TENANT. FAUCET AND PADDLE LEVERS C� Z m O Z WMi Z O DOOR FRAME HARDWARE �- -_ J Q � Q M i L:a 7C— t —� = 7—L r,--------- REFRIGERATOR STAINLESS STEEL SINGLE PROVIDED BOWL SINK W/ GOOSENECK BY TENANT. FAUCET AND PADDLE LEVERS COAT ROD & 3 SHELF DETAIL A601 SCALE: '1/2"=1'-0" E (TIMBERU TOFFEE W/(2) AD A� PLASTIC LAMINATE 36" A.F.F. WITH 1 & 4" BACKSPLASH. BUILDING STANDARD (TIMBERLAKE FAIRFIELD O TOFFEE) LOWER CABINET W/0) ADJUSTABLE SHED AND 4" WIRE PULLS. 3/4" WHITE MELAMINE SHELF 3/4" WHITE MELAMINE TRIM 3/4"D WHITE MELAMINE END SUUPPORTS (TYP. EACH END) 1-1/4" dia. CHROME ROD NOTE: WHERE SPAN EXCEEDS 4'-0" A CENTER SUPPORT BRACKET IS TO BE USED OFFICE 243 5 ELEVATION A601 SCALE: 1/2"=1'-0" DOOR SCHEDULE C� Z m O Z WMi Z O DOOR FRAME HARDWARE �- -_ COAT ROD & 3 SHELF DETAIL A601 SCALE: '1/2"=1'-0" E (TIMBERU TOFFEE W/(2) AD A� PLASTIC LAMINATE 36" A.F.F. WITH 1 & 4" BACKSPLASH. BUILDING STANDARD (TIMBERLAKE FAIRFIELD O TOFFEE) LOWER CABINET W/0) ADJUSTABLE SHED AND 4" WIRE PULLS. 3/4" WHITE MELAMINE SHELF 3/4" WHITE MELAMINE TRIM 3/4"D WHITE MELAMINE END SUUPPORTS (TYP. EACH END) 1-1/4" dia. CHROME ROD NOTE: WHERE SPAN EXCEEDS 4'-0" A CENTER SUPPORT BRACKET IS TO BE USED OFFICE 243 5 ELEVATION A601 SCALE: 1/2"=1'-0" DOOR SCHEDULE C� Z m O Z WMi Z O DOOR FRAME HARDWARE �- \ -_ iIL COAT ROD & 3 SHELF DETAIL A601 SCALE: '1/2"=1'-0" E (TIMBERU TOFFEE W/(2) AD A� PLASTIC LAMINATE 36" A.F.F. WITH 1 & 4" BACKSPLASH. BUILDING STANDARD (TIMBERLAKE FAIRFIELD O TOFFEE) LOWER CABINET W/0) ADJUSTABLE SHED AND 4" WIRE PULLS. 3/4" WHITE MELAMINE SHELF 3/4" WHITE MELAMINE TRIM 3/4"D WHITE MELAMINE END SUUPPORTS (TYP. EACH END) 1-1/4" dia. CHROME ROD NOTE: WHERE SPAN EXCEEDS 4'-0" A CENTER SUPPORT BRACKET IS TO BE USED OFFICE 243 5 ELEVATION A601 SCALE: 1/2"=1'-0" DOOR SCHEDULE C� Z m O Z WMi Z O DOOR FRAME HARDWARE REMARKS SIZE J Q � Q M O Q W Q < W Q � O Q W N 1:73W �t-20tH Y2(nCnnC��N� UONO ��ado���o 11 11 11 It II II II II CL c) m c��� n J Vl � U0�21in _ = W 2 Y U h— 200 RECEPTION 203'-0 8'-0" 1 3/4' WD/GL D1 WOOD D1 P/P,FL,DB,CL,S SEE NOTE 5. 203 MAIL ROOM 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 PS,S — 204 FILE ROOM 3'-0' 8'-0" 1 3/4" WOOD D2 HM D2 L,CL,S 45 MIN. RATED 205 CONFERENCE 3'-0' 1 8'-0" 1 3/4"1 WOOD D2 I HM D2 PS,S J 206 CONFERENCE 3'-0" 8'-0" 1 3/4' WOOD D2 HM D2 PS,S Of Sheets 208 COATS 203'-0 8'-0" 1 3/4' WOOD D3 HM D3 DM,MG,S 209 OFFICE 3'-0' 8'-0" 1 3/4" WOOD D2 HM D2 L'S 210 OFFICE 3'-0" 8'-0' 1 3/4" WOOD D2 HM D2 L'S 213 OFFICE S-0" 8'-0" 1 3/4" WOOD D2 HM D2 L'S 215A BREAK ROOM 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 PS,S,CL 2156 BREAK ROOM S-0" 8'-0" 1 3/4*1 WOOD D2 HM D2 L,S,CL 216 OFFICE 3'-0" 8'-0" 1 3/4 WOOD D2 HM D2 PS,S 217 SERVER ROOM 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 L,CL,S 219 STORAGE 3'-0' 8'-0" 1 3/4" WOOD D2 HM D2 L,S 220 OFFICE S-0" 8'-0" 1 3/4*1 WOOD D2 HM D2 L,S 221 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 L,S 222 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 LIS 223 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 PS,S 224 OFFICE S-0" 8'-0" 1 3/4*1 WOOD D2 HM D2 PS,S 225 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 PS,S 226 OFFICE 3'-0' 8'-0" 1 3/4" WOOD D2 HM D2 PS,S 227 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 L,S 229 OFFICE 3'-0" 8'-0" 1 3/4"1 WOOD D2 HM D2 PS,S 230 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 L,S 231 OFFICE S-0" 8'-0" 1 3/4" WOOD D2 HM D2 PS,S 232 OFFICE 3'-0" 8'-0" 1 3/4 WOOD D2 HM D2 PS,S 233 OFFICE S-0" 8'-0" 1 3/4!1 WOOD D2 HM PS,S 234 OFFICE 3'-0" g'-0" 1 3/4" WOOD D2 HM flD2 PS,S 235 STORAGE 3'-0" 8'-O" 1 3/4" WOOD D2 HM PS,S 236 KITCHENETTE 3'-0' 8'-0" 1 3/4" WOOD D2 HM D2 PS,CL,S 237 OPEN OFFICE 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 I CL,S 238 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 L,S 239 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 PS,S 240 OFFICE S-0" 8'-0" 1 3/4" WOOD D2 HM D2 L,S 241 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 PS,S 242 OFFICE 3'-0" g'-0" 1 3/4" WOOD D2 HM D2 L'S 243A OFFICE S -O" 8'-0" 1 3/4" WOOD D2 HM D2 L,S 2436 OFFICE 3'-0' 8'-0" 1 3/4" WOOD D2 HM D2 L,S 244 CONFERENCE S-0" 8'-0" 1 3/4" WOOD D2 HM D2 PS,S 245 OPEN OFFICE 3'-0" 8'-0" 1 3/4"1 WOOD D2 HM D2 L,CL,S 246 OFFICE S-0" 8'-0" 1 3/4" WOOD D2 HM D2 PS,S 248 IT ROOM 3'-0" 8'-0" 1 3/4" WOOD D2 HM D2 L,CL,S 2" WOOD CAP TO MATCH DOOR STAIN. OFFICE 216 SOUTH WALL ELEVATION A601 % SCALE 1/2a=1' -o' P2 Architecture Engineering D I r W4 Land Surveying Corporate Office (TIMBER P2 OFFICE 216 SOUTH WALL ELEVATION A601 % SCALE 1/2a=1' -o' BUILDING STANDARD BY TENANT. (TIMBERLAKE FAIRFIELD OM i I TOFFEE) LOWER CABINETS 41 I W/(1) ADJUSTABLE SHELVES I AND 4" WIRE PULLS. I 3'-6" L 2'-6" L 3'-0" n L S-0- -4 KITCHENETTE 236 6 ELEVATION A601 SCALE- 1 /2"=1'-0" D1 = FRAME c� w x ti z �o U =3 LEVER i HARDWARE 00 Q DOOR/FRAME ELEVATIONS SCALE. 1/4'=1'-0' TEMPERED INSET ?E STD. E ARE DOOR SCHEDULE NOTES 1. ALL NEW DOORS ARE TO BE BUILDING STANDARD. 2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD WHERE NEEDED. 3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4. COORDINATE KEYING LOCKSETS WITH TENANT. 5. ENTRY DOORS #200 ARE TO BE STAINED TO MATCH EXISTING DOORS. WOOD CHALK RAIL TO MATCH DOOR STAIN. uke NULTY CORPORA7toli 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 ILDING STANDARD Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office (TIMBER KE FAIRFIELD OAK C 0 a� O � TOFFEE UPPER CABINETS C .0 m IY \ / \ W/(2) AD USTABLE SHELVE U W J — 0 4" WIRE PULLS. V ca — — — — �Q o _Z Z \ a Z a CM 0a W U_ ca C Z LcGd PLASTIC LAMINATE CONTER 0 -------- i Q W 0 2 I Z r/ 36 A.F.F. WITH 1 1 EDGE i W J W Cert ` 1 Af>.,,�.�'Ll� AR & 4" BACKSPLAS pL2 ; Drawing Number: A601 Of Sheets Duke Job Number: 0000 A/E Job Number: . STAINLESS STEEL SINGLE REFRIGERATOR i BOWL SINK W/ FAUCET AND GOOSENE PADDLE LB PROVIDED BUILDING STANDARD BY TENANT. (TIMBERLAKE FAIRFIELD OM i I TOFFEE) LOWER CABINETS 41 I W/(1) ADJUSTABLE SHELVES I AND 4" WIRE PULLS. I 3'-6" L 2'-6" L 3'-0" n L S-0- -4 KITCHENETTE 236 6 ELEVATION A601 SCALE- 1 /2"=1'-0" D1 = FRAME c� w x ti z �o U =3 LEVER i HARDWARE 00 Q DOOR/FRAME ELEVATIONS SCALE. 1/4'=1'-0' TEMPERED INSET ?E STD. E ARE DOOR SCHEDULE NOTES 1. ALL NEW DOORS ARE TO BE BUILDING STANDARD. 2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD WHERE NEEDED. 3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4. COORDINATE KEYING LOCKSETS WITH TENANT. 5. ENTRY DOORS #200 ARE TO BE STAINED TO MATCH EXISTING DOORS. WOOD CHALK RAIL TO MATCH DOOR STAIN. uke NULTY CORPORA7toli 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 2o0 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 OcovAht 2001 C 0 a� O � TM C .0 m IY r o o 0 s cn U W J M 0 W V ca Cc O O �Q o _Z Z 0 V) a Z a CM 0a W U_ ca C Z LcGd - 12f 4 JU � Q W 0 2 Cw Z Q Q W J W Cert ` 1 Af>.,,�.�'Ll� AR Drawing Number: A601 Of Sheets Duke Job Number: 0000 A/E Job Number: 24198 2ND FLOOR FINISH PLAN SCALE: 1/80 = 1'-0" GENERAL FINISH NOTES: A. ALL DOORS TO BE FINISHED TO MATCH EXISTING DOORS. B. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD. C. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPORVAL OF ARCHITECT. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. D. CARPET TO CARPET ANDLOR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS RttQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH E. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE, FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING IN';TALLATION. F. G.U. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VpNYL TILE TRANSITIONS TAKE PLACE. G. W(RIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS. IFI NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. H. PAINT NEW OR EXISTING PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT, COLOR TO MATCH ADJACENT WALL FINISH. 1. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. J. PAINT ALL EXPOSED MUAL SURFACES (ie. GRILLS HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SUhFACE. K. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. FINISH PLAN NOTES: Ft VCT TO BE INSTALLED IN RANDOM PATTERN, 33% VCT1, 33% VCT2, 337.VCT3. F2 NEW FINISHES TO MATCH EXISTING CORRIDOR FINISHES. F3 OPERABLE WALL VINYL TO BE SUBMITTED TO DESIGNER FOR SELECTION AND APPROVAL. FINISH LEGEND: FLOORCOVERINGS �� CARPET – DIRECT GLUE MFG: J & J INVISION PATTERN: FLOORED (9143) COLOR: 906, BOWLED OVER c2 CARPET – DIRECT GLUE MFG: J & J COMMERCIAL PATTERN: LINK (2665) COLOR: 1641, INTERNET c3 CARPET – DIRECT GLUE MFG: J & J COMMERCIAL PATTERN: TEXTURES 36 (4655) COLOR: NOON (1404) vcTt VINYL COMPOSITION TILE MFG: ARMSTRONG PATTERN: STONTEX EXCELON COLOR: 52149, COCOA BROWN E2 VINYL COMPOSITION TILE MFG: ARMSTRONG PATTERN: STONTEX EXCELON COLOR: 52139, LIMESTONE BEIGE vCT3 VINYL COMPOSITION TILE E� MFG: ARMSTRONG PATTERN: STONTEX EXCELON COLOR: 52143, SANDSTONE TAN BASE gt VINYL BASE –4" COVE BASE MANUFACTURER: JOHNSONITE COLOR: 09, CLAY WALLCOVERING W1 MFG:LEN–TEX, MDC PATTERN: MANHATTAN COLOR: DELANCEY (4613–MN) TYPE II QUOTE #: 40094511 W2 MFG: VERSA, DL COUCH PATTERN: CARIBE COLOR: A47-187, FLAX TYPE I QUOTE #: DUKE2003 W3 MFG: VYCON, MDC PATTERN: CONNECT COLOR: SABLE BLANC, Y44815CT TYPE 11 QUOTE #: 40094511 W4 MFG: MDC MEMERASE PATTERN: WHITEWALL COLOR: WHITE MWW-5401 PAINT QUOTE #: 40094511 P1 MFG: ICI COLOR: 709, MANUSCRIPT FINISH: EGGSHELL P2 MFG: ICI COLOR: 634, LA MESA FINISH: EGGSHELL P3 MFG: ICI COLOR: 530, CAMELCOAT FINISH: EGGSHELL PLASTIC LAMINATE F-P—L71 MANUFACTURER: NEVAMAR COLOR: PAINTED WOODLANDS,PDG002T FINISH: TEXTURED PL2 MANUFACTURER: WILSONART COLOR: SUNSTONE, 4781-60 Duke Ii &W CONIMTioN 600 East 96th Street Suite 100 Indianapolis IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 OCOW qht 2001 c 0 .T a� D' m m' -o W CO \ Co c 30 Y cn o o v ozz Z Q aoV)0� N 0 z d. ���Js C0'O: Z � JQ U U. 2 Cer ' 4VT�+rli tMIM I 4 ;STATS OF r Drawing Number: A801 Of Sheets Duke Job Number: 0000 A/E Job Number: 24198 2!D FLOOR ELECTRICAL/DATA PLAN GENERAL ELECTRICAL NOTES: E. ROVIDE JUNCTION BOXES H AS INDICATED ON PLANS. PROVIDED BY THE TENANT CONDUCTORS SHALL. BE INSTALLED IN CONDUIT. CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL TS TO BE COMPATIBLE WITH TENANT EQUIPMENT. SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO ELECTRICAL LOCATIONS AND CIRCUITING REQUIREMENTS WITH TENANT AND/OR )EALERSHIP FOR SYSTEMS BASE FEED AND OR POWER POLES. CONTRACTOR TO HARDWIRE FURNITURE TEM TO BUILDING POWER SOURCE. AUJ RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS ANDSHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH. F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED ® 18" A.F.F. O NEW VOICE/DATA SUPPLY FOR SYSTEM FURNITURE. UNLESS OTHERWISE NOTED. 0 NEW CORE DRILL OUTLET. VERIFY EXACT LOCATION WITH TENANT. ELECTRICAL PLAN NOTES - E1 PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY POWER REQUIREMENTS WITH TENANT EQUIPMENT. O NOT USED. O NOT USED. E4 PROVIDE POWER FOR TENANT SUPPLIED DISHWASHER. O VERIFY EXACT LOCATION OF CORE DRILLS WITH TENANT AND/OR FURNITURE VENDOR. ELECTRICAL LEGEND: NEW DUPLEX WALL OUTLET NEW QUADRAPLEX WALL OUTLET (5D NEW DEDICATED CIRCUIT OUTLET NEW DEDICATED 30 AMP 125 VOLT OUTLET. dGFI NEW GROUND FAULT INTERRUPT CIRCUIT OUTLET 0 NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING) O NEW JUNCTION BOX ! NEW POWER SUPPLY FOR SYSTEM FURNITURE. NEW CORE DRILL DATA OUTLET. VERIFY EXACT LOCATION WITH TENANT. AWA Duke REALTY CORPORAnoN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 eM 2001 0 Of 0 � m ili p co 3 YW v U N d 0 C L U z Q J a Zz Q CIO 0 NoZo Ix- WU J J C/) P. z w Q V Q ~ 2 V W mi W Ce-:.' !� �R0091DQ3&� �= ` WTAl E OF .�� G,``` Drawing Number: E201 Of Sheets Duke Job Number: 0000 A/E Job Number: 24198