HomeMy WebLinkAbout04100179 Building PlansARCHITECT:
CSO
280 E. 96TH STREET, SUITE 200
INDIANAPOLIS, INDIANA 46240
(317) 848.7600 (377) 574.1869 FAX
CONTRACTOR:
�6i
Duke
REALTY CORPORATION
600 E. 96th STREET
SUITE 100
INDIANAPOLIS, IN 46240
PHONE: (317)808-6000
INDEX OF DRAWINGS
01
MILLWORK SHAM BE FABRICATED FROM FIELD MEASUREMENTS WITH
1 COVER
0
el
1.11
I A201
DEMOLITION CONSTRUCTION PLAN
ol
t i
I A202
REFLECTED CEILING PLAN
91
12.1
A601
ELEVATIONS DETAILS
•
A801
FINISH PLAN
•
1.12
E201
ELECTRICAL DATA PLAN
C APPROVED AS SUBMITTED El APPROVED AS NOTED 1:1 REJECTED
SIGNATURE DATE
COMPANY
2ND FLOOR
KEY PLAN
SCALE: NTS NORTH
HAMILTON CROSSING VI
SPECIFICATIONS AND GENERAL NOTES
MILLWORK SHAM BE FABRICATED FROM FIELD MEASUREMENTS WITH
9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR
0
CONTRACT CONDITIONS
1.11
PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL
PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY,
t i
CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION
0.1
THE GENERAL CONDITIONS SHAM BE AIA DOCUMENT A201 - 1987 EDITION,
12.1
EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE
ENTITLED 'GENERAL CONDITIONS OF THE CONTRACT FOR
PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
CONSTRUCTION'. THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF
1.12
PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION
THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE
NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND
SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD
RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED
FOLLOWING:
MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CAM FOR IN
INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND
AS FOLLOWS:
THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE
STRAIGHT WITH NO DISTORTIONS.
INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL
6.10
32 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND
1. FERROUS METAL
PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD.
.3 YORKTOWNI CABINETS
FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE
WIDTH NOT TO EXCEED 1/8 U.O.N.
A ACRYLIC SEMI -GLOSS ENAMEL FINISH:
PROCEEDING WITH CONSTRUCTION.
2
DEMOLITION
1. PRIMER I COAT 141702 METALCIAD ACRYLIC
SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE
MECHANICAL AND ELECTRICAL
OUTLETS.
RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS,
2.1
COORDINATE DEMOLITION WITH CONSTRUCTION PIANS TO DETERMINE
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES.
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE
MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND
7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY
BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW
GOVERNMENTAL FEES, LICENSES AND INSPECTIONS.
7
WORK.
2. NON-FERROUS METAL: "'"�
3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING
2.2
WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR
ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND
EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT,
7.1
WORKMANSHIP.
1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC
OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION
CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL
1�.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY
AND FIXTURES:
.1 DOW CORNING 786'; DOW CORNING CORP.
TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND
PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE
SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING
SEMI -GLOSS FINISH
CONTRACTOR'S RESPONSIBILITY.
INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
.2
.3 '863 #345 WHITE'; PECTORA CORP.
'PROGLAZE
3. FERROUS STRUCTURE
15/16.2
WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED
0.2
WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES,
A ACRYLIC DRY FOG FLAT FINISH:
TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR
DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND
RULES AND REGULATIONS.
.5 SONN®ORN BUILDING PRODUCTS
ADDITIONAL WORK RELATED TO SUCH ACTIVITIES.
0.3
ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD
2.3
WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED
REDUCIBLE ACRYLIC DRY FOG COATING
QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF
CERTIFIED ENGINEER.
MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL
ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING
THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION
15/16.3
BE INCLUDED,
IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED
2.4
REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE
DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS
PROJECT.
'AC -20"; PECORA CORP.
DRAWINGS.
0.4
WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE
2.5
ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE
8. WOOD:
SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND
AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL
ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED
.3
.4 'TREMCO ACRYLIC LATEX 834"; TREMCO, INC.
WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE
FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND
SPECIFIED CAPACITIES OF THE EQUIPMENT.
1. PRIMER: 1 COAT 151701 WONDER -PRIME LATEX
METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW
0.5
WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS
DOORS AND WINDOWS
FINISHES.
ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING
2.6
EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL
SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL
REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR
INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS
GOVERN THE WORK.
NOTED TO BE REPAIRED.
0.6
NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE
2.7
SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS.
DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS
SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN
2.8
REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS
DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT
REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK
PASTE WOOD FILLER (OPEN GRAIN WOODS).
CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY
OWNER'S AGENT.
IN SCOPE OF CONTRACT.
DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH
OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S
2.9
PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING
INTERPRETATION.
ALKYD STAIN.
DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS
0.7
INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048
ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS
MANUFACTURER'S RECOMMENDATIONS.
SHAM BE LARGE ENOUGH TO PREVENT THE HAUUNG/SPREADING OF DIRT
1
GENERAL REQUIREMENTS
EQUIPMENT.
THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS.
4. FINISH: 2 COATS 14600 WONDER WOODSTAIN
2.10
CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES
1.1
WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS
ALKYD SATIN VARNISH.
AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY
GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER.
WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR
SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE -
15/16.8
BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT.
9.1
OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED
1.2
THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS
INSTALLED BY OTHERS UNLf SS OTHERWISE NOTED. CONTRACTOR SHALL
CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO
INCLUDING BUT NOT UNTIED TO TELEPHONE/DATA, SECURITY, FURNITURE
DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS
AND 'FURNISHED AND/OR INSTALLED" ITEMS. CONTRACTOR SHALL
PRIMER -SEALER.
PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS.
TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE
COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING,
AT CEILING. USE PREFORMED OUTSIDE CORNERS.
CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A
'AS
AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE
RECORD SEPIA TO SERVE AS PART OF THE -BUILT' SET.
LATEX SATIN ENAMEL
WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR
2,11
PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT,
GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE 'X' TAPERED
REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS.
SETTLEMENT
SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE
1.3
CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING
A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS)
AND ADJACENT FACILITIES OR WORK TO REMAIN.
ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
5
METAL FABRICATIONS
WORKMANSHIP.
WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS.
1.4
SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE
51
PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED
FOLLOWING ITEMS:
15/i6.11
OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS
1 METAL FABRICATIONS.
TEXTURE COATING. =
REQUIRED TO COMPLETE WORK.
SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL
.2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS.
6
WOOD AND PLASTIC
DOORS, FRAMES AND HARDWARE.
MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA.-
SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL
IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL
"CONSTRUCTION
216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND
PANEL ).
61
CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE
.5 VCT FLOORING AND BASE (COLOR SAMPLES ).
WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13
GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE
CARPET {DYE LOT CUTTING AND SEAMING DIAGRAMS ).
CONTENT.
LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO
PAINT ( 6' X 6' ON ACTUAL SURFACE ).
P
6.2
PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE
' " _
ALLCOVERINGS (9" X 9" DYE LOT CUTTING ).
EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA
ACCEPTABLE,
SIGNAGE ( SAMPLE SIGN ).
C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32".
.2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6' FROM
10 EIGHT FIXTURES ( CATALOG CUTS ).
6.3
FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND
1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL (TENS
OUTSIDE CORNERS.
PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA
1.5
TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES,
C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH
GENERAL NOTES
TEMPORARY ENCLOSURES, ARE PROTECTION, HEAT AND POWER
REFLECTED CEILING PLAN SHALL GOVERN,
CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING
WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR
JURISDICTION.
THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING
6.4
FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI
LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS
CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S
STANDARDS.
1.6
AGENT.
THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND
BUILDING STANDARD, PROVIDE JL INDUSTRIES 'AMBASSADOR" SERIES,
.1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR
PROCEEDING WITH CONSTRUCTION.
OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR
TO FABRICATION OF MULTIPLE UNITS.
1'ri.2
SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS,
TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT
6.5
COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH
EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE.
NEMA LD 3 AND GP -50 (0.050' NOMINAL THICKNESS).
CASED OPENING UNLESS NOTED OTHERWISE
THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES
A TO FINISHED FACT OF GYPSUM BOARD,
ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT
1 EDGE TREATMENT SAME AS LAMINATE CLADDING ON HORIZONTAL
B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS.
ADDITIONAL CHARGE TO THE PARTY AFFECTED.
.1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET
SURFACES.
2 PROVIDE 2' DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE
1.7
THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS
MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH
CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS
D. TO BOTTOM OF FINISHED CEILINGS.
ELECTRICAL OR DATA OUTLET LOCATIONS.
CARPET.
TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS.
1.8
SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
6.6
CABINETS: COMFY 44-01 SECTION 400 AND ITS DIVISION 4006 FOR
SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION,
PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED,
RESILIENT FLOORING:
PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS.
SUBMIT THE FOLLOWING INFORMATION:
GNA
TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED
1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOP'-
.1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS
PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF
GP -50 (0.050' NOMINAL THICKNESS); VERTICAL SURFACES: GP -28
.�
PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES.
(0.028' NOMINAL THICKNESS); EDGES: GP -28 (0.028' NOMINAL
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION
PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED.
OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO
THICKNESS).
PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL
.2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28,
CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
.3 CABINET HARDWARE SCHEDULE:
.2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID
ACCOMMODATE THE SUBSTITUTION.
NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING
.4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL
1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES'
WITH CONSTRUCTION.
AFFECT THE CONTRACT SUM AND CONTRACT TIME.
ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS.
BY GRASS OR EQUAL
GN.6
CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT
.2 PULLS: WIRE PROJECTING TYPE, DRILLING 4' ON 4'' LATER,
1.9
STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME
FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT.
14483 OR EQUAL AS MANUFACTURED BY STANLEY.
USE AN APPROVED CEMENTTTIOUS FILLER TO PATCH CRACKS, SMALL
FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING.
.3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHEF WITH
1.10
THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHAM ARRANGE FOR
MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS
OBSERVATION.
HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE
SURFACE VARIATION OF 9" IN 10 FEET, NON -CUMULATIVE.
MANUFACTURED BY STANLEY.
GN.7
BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN
.4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES
REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS.
LIMTFD TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT
WITH POSITIVE STOP AND LOCKOUT POSITION, WITH
HEAVY-DUTY FULL EXTENSION; 11429 OR EQUAL AS
9.8
CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING
MANUFACTURED BY KNAPE Et VOGT.
CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED.
STANDARDS:
.5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF
GN.8
CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO
SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECT". 'i
CLOSE -IN OF WALLS.
MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED
FLAMMABILITY: ASTM 2859
GN.9
SHELVING STANDARDS AS PRODUCED BY KNAPE k 'OGT
SURFACE BURNING: ASTM E84
OR EQUAL
SUITE 200
P
CARMEL; INDIANA
6.7
MILLWORK SHAM BE FABRICATED FROM FIELD MEASUREMENTS WITH
9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR
12
FURNISHINGS
PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS.
PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY,
t i
6.8
DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING,
REINSTALL SUCH ITEMS.
12.1
CASEWORK:
WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED
WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY
.1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT
11 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE
OPERATING FOR TEN DAYS.
SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD
FOLLOWING:
6.9
INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND
FOR THE VARIOUS SUBSTRATES, AS INDICATED.
.1 IMPERIAL CABINET CO., INC.
STRAIGHT WITH NO DISTORTIONS.
_ _ .2 MERILLAT INDUSTRIES, INC.
6.10
JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM
1. FERROUS METAL
._
.3 YORKTOWNI CABINETS
WIDTH NOT TO EXCEED 1/8 U.O.N.
A ACRYLIC SEMI -GLOSS ENAMEL FINISH:
6.11
GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL
1. PRIMER I COAT 141702 METALCIAD ACRYLIC
15/16 ".,
MECHANICAL AND ELECTRICAL
OUTLETS.
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
15/16.1
MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND
SEMI -GLOSS ENAMEL
ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE
7
JOINT SEALERS
2. NON-FERROUS METAL: "'"�
; `
RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS
A ACRYLIC SEM( -GLOSS ENAMEL FINISH:
ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC
7.1
ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS
1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC
�:
CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL
AND FIXTURES:
.1 DOW CORNING 786'; DOW CORNING CORP.
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC
BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE,
"SCS 1702 SANITARY'; GENERAL ELECTRIC CO.
SEMI -GLOSS FINISH
INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND
.2
.3 '863 #345 WHITE'; PECTORA CORP.
'PROGLAZE
3. FERROUS STRUCTURE
15/16.2
ELECTRICAL SYSTEMS.
GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF
.4 WHITE'; TREMCO CORP.
'OMNIPLUS';
A ACRYLIC DRY FOG FLAT FINISH:
DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND
.5 SONN®ORN BUILDING PRODUCTS
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A
REDUCIBLE ACRYLIC DRY FOG COATING
CERTIFIED ENGINEER.
7.2
ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING
4. NON-FERROUS STRUCTURE:
15/16.3
IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S
SURFACES:
.1 'CHEM -CALK 600% BOS11K CONSTRUCTION PRODUCTS DIV.
A ACRYLIC DRY FOG FLAT FINISH:
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS
'AC -20"; PECORA CORP.
REDUCIBLE ACRYLIC DRY FOG COATING.
DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN)
.2
SONOLAC ; SONNEBORN BUILDING PRODUCTS
8. WOOD:
AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL
.3
.4 'TREMCO ACRYLIC LATEX 834"; TREMCO, INC.
A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH:
DRAWINGS SHALL GOVERN, NOTIFY ARCHITECT OF DISCREPANCIES AND
OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK.
1. PRIMER: 1 COAT 151701 WONDER -PRIME LATEX
15/16.4
SUBMIT ARE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE
8
DOORS AND WINDOWS
PRIMER -SEALER.
OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL
8.1
INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS
SEMI -GLOSS ENAMEL
COORDINATE WITH OTHER CEILING COMPONENTS.
NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER.
B. STAIN -VARNISH RUBBED FINISH:
15/16.5
DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS
8.2
INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED
1. FILLER: 1 COAT #4800 WONDER WOODSTAIN
SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR
OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH.
PASTE WOOD FILLER (OPEN GRAIN WOODS).
OWNER'S AGENT.
8.3
DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH
2. STAIN: 1 COAT #96XX WONDER WOODSTAIN
15/16.6
OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED
AND LOCKSETS.
ALKYD STAIN.
WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED.
8.4
GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048
3. SEALER: 1 COAT 1490D WONDER WOODSEALER
VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED
REQUIREMENTS FOR HEAT -STRENGTHENED GLASS,
QUICK DRY SEALER.
EQUIPMENT.
4. FINISH: 2 COATS 14600 WONDER WOODSTAIN
15/16.7
SWITCHES SHALL BE GANGED UNDER ONE PLATE, DIMMERS SHALL BE
9
FINISHES
ALKYD SATIN VARNISH.
GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER.
10. GYPSUM WALLBOARD:
15/16.8
DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND
9.1
GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645.
A. ACRYLIC LATEX SATIN ENAMEL FINISH:
INSTALLED BY OTHERS UNLf SS OTHERWISE NOTED. CONTRACTOR SHALL
1. PRIMER: 1 COAT 150801 WONDER TONES LATEX
COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND
.1 INSTALL 'EUMINATOR' TYPE HEAD TRACK AT WALLS TERMINATING
PRIMER -SEALER.
TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE
AT CEILING. USE PREFORMED OUTSIDE CORNERS.
2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC
INSTALLATION SHALL OCCUR.
LATEX SATIN ENAMEL
15/16.9
DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF
9.2
GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE 'X' TAPERED
13, PRECAST CONCRETE:
OUTLETS, UNLESS OTHERWISE NOTED.
EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND
A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS)
15/16.10
ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD
JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE
1. PRIMER: 1 COAT 11502 WONDER -SHIELD ACRYLIC
COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE
WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS.
LATEX HOUSE PAINT PRIMER.
IVORY.
2. FINISH: 1 COAT 144101 DEV-VO-TEX LATEX
15/i6.11
WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY
.1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED
TEXTURE COATING. =
SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL
INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH
PROVIDING PROPER ACCESS TO RECEPTACLES.
MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA.-
15/16.12
IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL
216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND
9,11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND
FOR SPECIFIC LOCATION,
FINISHING OF GYPSUM BOARD.
WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13
CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET
LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO
9.4
COUNGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM
.1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT
' " _
OBSERVE PRIOR TO ANY COMMENCEMENT OF "ROUGH -IN"
DAMAGED OR SOILED TILES.
ACCEPTABLE,
C110N.
.2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6' FROM
1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL (TENS
OUTSIDE CORNERS.
IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL
GN
GENERAL NOTES
REFLECTED CEILING PLAN SHALL GOVERN,
10 SPECIALTIES
.2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN
GN.1
CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND
LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS
10.1 FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO
REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO
UNLESS NOTED OTHERWISE.
BUILDING STANDARD, PROVIDE JL INDUSTRIES 'AMBASSADOR" SERIES,
PROCEEDING WITH CONSTRUCTION.
SEMI RECESSED, DUO -PANEL, FIELD PAINTED.
1'ri.2
DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED:
9.5
INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR
CASED OPENING UNLESS NOTED OTHERWISE
A TO FINISHED FACT OF GYPSUM BOARD,
B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS.
.1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET
C. TO TOP OF FINISHED FLOORS.
MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH
D. TO BOTTOM OF FINISHED CEILINGS.
CARPET.
GN.3
SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION,
9.6
RESILIENT FLOORING:
EXISTING CONSTRUCTION AND WALL TYPES.
GNA
TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED
.1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS
OTHERWISE
ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT
GN.5
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION
OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO
LOCATIONS DIMENSIONS AND TYPES DOOR AND WINDOW LOCATIONS
AVOID USE OF CUT WIDTHS LESS THAN 3' AT ROOM PERIMETER.
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
.2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID
NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING
BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING
WITH CONSTRUCTION.
ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS.
GN.6
CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT
FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT.
9.7
USE AN APPROVED CEMENTTTIOUS FILLER TO PATCH CRACKS, SMALL
DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS
HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM
OBSERVATION.
SURFACE VARIATION OF 9" IN 10 FEET, NON -CUMULATIVE.
GN.7
FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT
LIMTFD TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT
FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4' IN 20'-0' NON -
9.8
CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING
CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED.
STANDARDS:
GN.8
CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO
CLOSE -IN OF WALLS.
FLAMMABILITY: ASTM 2859
GN.9
SOUND INSULATED AND ARE RATED PARTITIONING SHALL BE CAULKED AT
SURFACE BURNING: ASTM E84
PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE.
SMOKE DENSITY: ASTM E662
PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE.
SOUND ABSORPTION: ASTM C423
PROVIDE WITH SOUND ATTENUA iivG INSULATION SECURELY FASTENED
FADE RESISTANCE: AATCC 16E
TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL
STATIC RESISTANCE: AATCC 134
JUNCTION BOXES ARE NOT PERMTTED.
WARRANTY: 10 YEARS
GN. O
ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY
CONTRACTOR.
.1 INSTALL BROADLOOM CARPET BY DIRECT GLUE.
F
tiFSE� N
S3, E
u .
1,71
O tis y
Oz7;r6'�',%'�;���� LCl
F O�
C.
0� < �U
Zd .per �
'� x'41'+ -,,,T, t .�, ,,,� ►�' � *:•, � � i.,-..� � �11n�,'��/� �� �^
ti=Ncuvnn03U
»�'v1 j ~`fit, �f1�7'fi
'-101 SNV'ld3S3Hu!
CITY OF CARMEL/CLAY TOWNSHIP
Dept. of Community Services -- Building & Code Enforcement
One Civic Square I" Floor; Carmel, IN 46032
PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT
rAs the authorized agent responsible for obtaining a permit or permits', I certify that these plans
are IDENTICAL to those released for construction by the Indiana Depart. of Fire & Building
Services. I also understand that if it is determined that these plans are not identical, a STOP
WORK OR ER will be served, as required under the Ordinances referenced below.
Authorized Signature Printed Name
'Required wider Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2
and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning Ordinance, Section
31.1 entitled "Violations and Penalties". u
S:Permits/Forms/AuthentStickerll-Ill �.{-� '/ ca -
[1
091Df� J
STATf.o
'9 !N 'ANO` .r
9/23/04
CSO #24198
a-
t i
;-
7
h
4wl
'� x'41'+ -,,,T, t .�, ,,,� ►�' � *:•, � � i.,-..� � �11n�,'��/� �� �^
ti=Ncuvnn03U
»�'v1 j ~`fit, �f1�7'fi
'-101 SNV'ld3S3Hu!
CITY OF CARMEL/CLAY TOWNSHIP
Dept. of Community Services -- Building & Code Enforcement
One Civic Square I" Floor; Carmel, IN 46032
PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT
rAs the authorized agent responsible for obtaining a permit or permits', I certify that these plans
are IDENTICAL to those released for construction by the Indiana Depart. of Fire & Building
Services. I also understand that if it is determined that these plans are not identical, a STOP
WORK OR ER will be served, as required under the Ordinances referenced below.
Authorized Signature Printed Name
'Required wider Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2
and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning Ordinance, Section
31.1 entitled "Violations and Penalties". u
S:Permits/Forms/AuthentStickerll-Ill �.{-� '/ ca -
[1
091Df� J
STATf.o
'9 !N 'ANO` .r
9/23/04
CSO #24198
GENERAL DEMOLITION NOTES:
A. DEMOLISH EXISTING WALLS THAT ARE SHOWN DASHED, BACK TO A POINT
WHEREAS A SMOOTH SURFACE REMAINS FOR INSTALLATION OF NEW FINISHES.
B. REMOVE DOORS AND DOOR FRAMES AS SHOWN DASHED. RESERVE DOORS
AND DOOR FRAMES FOR RE—USE IN NEW PROJECT SCOPE.
C. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED.
REFERENCE FINISH SHEET, A801, TO COORDINATE LOCATIONS OF NEW FINISHES
D. SAVE ALL ITEMS REMOVED FROM THE SPACE PER OWNERS DIRECTION UNLESS
OTHERWISE NOTED.
2ND FLOOR
DEMOLITION/CONSTRUCTION PLAN
.()
SCALE: ,/s° = r -o° rpt►,
DEMOLITION PLAN NOTES:
D� REMOVE SECTION OF WALL AND PREP FOR NEW DOOR LOCATION.
Ds REMOVE EXISTING TEMPORARY POWER OUTLETS.
D3 REMOVE EXISTING WALL AND DOOR AND PREP FOR NEW HALLWAY.
SAVE DOOR FOR RELOCATION AT NEW VACANCY, SEE CONSTRUCTION PLAN NOTE FP18.
D4 REMOVE EXISTING DOOR AND FRAME.
GENERAL CONSTRUCTION NOTES:
A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS
NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE
TO BE VERIFIED BY DESIGNER— DO NOT SCALE DRAWINGS.
B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS.
C. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN
ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A).
D. REFER TO CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES.
E REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH
WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE.
F. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL
G. APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, AND AT ALL
COUNTERTOPS AND BACKSPLASH JUNCTURES.
H. ALL WALLS SHALL BE CHAULKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION
1. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE
OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS
J. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL
BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARTION FOR NEW FINISHES.
K. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR
FINISHES AS SCHEDULED.
L G.C. TO PROVIDE BUILDING STANDARD MINIBLINDS AT ALL PERIMETER WINDOWS.
M. ALL NEW FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING TO CODE. UFESAFETY
CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE
SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED A PLAN MUST BE
SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY.
N. EXISTING DOORS AND DOOR FRAMES TO BE REUSED DURING CONSTRUCTION
DOORS THAT ARE QUESTIONABLE FOR REUSE, PLEASE CALL FOR DESIGNERS
REVIEW AND APPROVAL OF REUSE BEFORE INSTALLATION.
0. ALL NEW WORKSURFACES TO RECEIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS
TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT T NEW ELECTRICAL LAYOUT
ALTERNATES:
1. PRICE MOVEABLE PARTITION TO BE; XXX. INCLUDE STRUCTURAL
SUPPORT AND DRYWALL ENCLOSURE AS REQUIRED.
CONSTRUCTION PLAN NOTES:
ALIGN FINISHED FACES.
�rz CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS
USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION
FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT
BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/A601.
�s CENTER WALL BETWEEN WINDOWS.
�4 PROVIDE BLOCKING FOR OWNER SUPPLIED WHITEBOARD, VERIFY EXACT LCOATION WITH TENANT.
PROVIDE BUILDING STANDARD COULMN WRAP.
O EXISTING RECEPTION DESK, RELOCATED FROM TENANTS OLD SPACE.
& COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE
FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL.
�$ PROVIDE COAT ROD AND SHELF; REFERENCE DETAIL 3/A601.
O PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE
MAKER/REFRIGERATOR AND COFFEEMAKER. VERIFY EXACT LOCATION OF ALL
APPLIANCES, REQUIRING A WATER SOURCE WITH TENANT.
E3 G.C. TO INSTALL TENANT PROVIDED DISHWASHER. G.C. TO CONFIRM UNIT IS IN
WORKING ORDER AND IS NOT LEAKING BEFORE TURNING UNIT OVER TO TENANT.
E, REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER
SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER
19 VENDING MACHINES PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE
POWER SOURCE FOR VENDING MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH
MFG. MANUAL.
E) PROVIDE 3(4" x 4' x 8' FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD.
PAINTED WTH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH
E) NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION
WITH TOP OF CABINET AT 54" AFF.
E) PROVIDE MOVEABLE PARTITION TO BE: XXX INCLUDE STRUCTURAL
SUPPORT AND DRYWALL ENCLOSURE AS REQUIRED. PRICE AS ALTERNATE.
VERIFY EXISTING WALLS. ADD TO EXISTING WALLS AS REQUIRED TO MAKE
A W4 WALL TYPE.
E) PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED
WATER COOLER. VERIFY EXACT LOCATION WITH TENANT.
6 RELOCATE DOOR, SEE DEMOLITION PLAN NOTE D3.
WALL LEGEND:
NOTES: ALL NEW WALLS TO BE W1 UNLESS NOTED OTHERWISE.
_ _ = EXISTING CONSTRUCTION TO BE REMOVED
EXISTING PARTITION TO REMAIN
NEW WALL PARTITION
W1 2-1/2" 25 GAUGE METAL STUDS ®24"O.C.
WITH 5/8 GYPSUM WALL BOARD EACH SIDE.
WALLS TO EXTEND TO UNDERSIDE OF CEILING.
W2 2-1/2" 25 GAUGE METAL STUDS 024"O.C.
WITH 5/8" GYPSUM WALL BOARD EACH M
SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE
2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE
CEILING AND INSIDE WALL INSULATION TO EXTEND 2'-0" IN
BOTH DIRECTIONS FROM CENTER LINE OF WALL
W3 2-1/2" 25 GAUGE METAL STUDS 024" O.C. co
WITH 5/8" GYPSUM WALL BOARD ONE SIDE
WALLS TO EXTEND TO UNDERSIDE OF CEILING.
W4 2-1/2" 25 GAUGE METAL STUDS @16"O.C. 2
WITH TYPE "X" 5/8" GYPSUM WALL BOARD EACH
SIDE WALLS TO EXTEND TO STRUCTURAL DECK 1—HR RATED
ABOVE WALLS TO HAVE 1—HOUR RATING. UL DES. U465
W5 NEW WALL CONSTRUCTION TO MATCH ADJACENT
PARTITION CONSTRUCTION.
W6 NEW WALL CONSTRUCTION TO MATCH BUILDING STANDARD
DEMISING WALL CONSTRUCTION.
DENOTES AREA NOT IN CONTRACT
DENOTES NEW MILLWORK
FghNEW DOOR AND FRAME. REFER TO DOOR SCHEDULE
Il
REALTY ooRPORAnoN
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone:317 808-6000
Fax: 317) 808-6797
D
u' keFWL
n co�orunoN
East 96th Street
100
napolis, IN 46240
e: 317808-6000
317 808-6797
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ocoffight 20DI
in
c
0
v
�
a
�
�
Co >� V
m W
o
W
cn�
o
o
v
Z
Q
J
>-
a
ZZ
�
Z
a
oCOQ
V)0
J
N006 Z
W
W U
U
w
0
SOW
W
�Q
H
=
W
J
LL.
W
Ce _ TV.
iQ..
_ alb .... NA:. ,C . `•`
Drawing Number:
A202
Of Sheets
Duke Job Number:
0000
A/E Job Number:
24198
CD
I
(V
TYPICAL WALL TYPE
TYPICAL AT ALL EXTERIOR
WALLS— 5/8" TYPE X G.W.B.
FINISH BELOW EXISTING
WINDOW SILL COVER
METAL
STUD
PREFINISHED ALUMINUM RECEIVER TRIM
"GB350". FASTEN AT WINDOW SILL &
SET IN A CONTINUOUS BEAD OF
ACOUSTICAL SEALANT. TRIM COLOR TO
MATCH BLDG. WINDOW MULLIONS.
LINE OF EXISTING WINDOW SILL
COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
WINDOW
1 MULLION DETAIL
A601 SCALE: NTS
ADA SINK
4 BASE SECTION
A601 SCALE: 1/2"=1'-O"
BLOCKING AS REQUIRED
SINK AND HARDWARE ABOVE
RETRACTABLE HAEFLEE
HARDWARE
INDICATES DOOR IN RETRACTED
POSITION
ADJACENT CABINET
RECESSED BASE LINE BELOW
ARROW INDICATES DIRECTION
DF MOVEMENT BY RECTACTABLE
CABINET
4STRAGAL ON CABINET DOOR
TOUCH LATCH HARDWARE ON
NOTE: CABINET FRONTS
SINK PIPES BELOW ARE TO BE
WRAPPED FOR COMPLIANCE WITH
ADA GUIDELINES.
BREAKROOM 215
7 ELEVATION
A601 SCALE: 1/2 -4 -0 -
PLUMBING
ISOMETRIC
SCALE-- NTS
TOP OF 1 1/2" LAMINATE
BE AT BOTTOM EDGE OF
10'-1Y"
1 /2"HW,
1 /2"CW,
&
1-1/4"V
CONNECT TO
BUILDING MAINS
2"W
TO BUILDING DRAIN
CONFERENCE 205"
10 ELEVATION
A601 SCALE: 1/2"=1'-0'
BUILDING STANDARD
I i
(TIMBERLAKE FAIRFIELD OAK
DOOR
TOFFEE) UPPER CABINETS
/ \
W/(2) ADJUSTABLE SHELV
\
j/
—
Q
<
W
Q
�
OUTNER TO
N
1:73W �t-20tH
Y2(nCnnC��N�
UONO
��ado���o
11 11 11 It II II II II
CL c) m c��� n
J Vl � U0�21in
\ /
PLASTIC LAMIN�E COUNTER 0
WINDOW SILL
36" A.F.F. WITO 1 1/20 EDGE
RECEPTION
& 4" BACKSPKH. I PL2
8'-0"
REFRIGERATOR i i REFRIGERATOR i rWATER
WD/GL
PROVIDED i PROVIDED i i COOLER I
WOOD
I BY TENANT. } I BY TENANT.
i I i I I PROVIDED I
P/P,FL,DB,CL,S
BY TENANT.1
203
BUILDING STANDARD
3'-0"
(TIMBERLAKE tAIIIFIELD OAK 1
L�__,jj
4 TOFFEE) LO R �ABINETS
J��
W/(1) ADJUiABLE SHELVES I
AND 4" WIREIPULLS. I
PROVIDED
i I I I i I
i I i I I I
BY TENANT.
U.
L -------------J L -------------J I I
2'-9"
2'-9'
8'-0"
CONFERENCE 205"
10 ELEVATION
A601 SCALE: 1/2"=1'-0'
BUILDING STANDARD
I i
(TIMBERLAKE FAIRFIELD OAK
DOOR
TOFFEE) UPPER CABINETS
/ \
W/(2) ADJUSTABLE SHELV
\
AND 4" WIRE PULLS.
—
Q
<
W
Q
�
\ /
N
1:73W �t-20tH
Y2(nCnnC��N�
UONO
��ado���o
11 11 11 It II II II II
CL c) m c��� n
J Vl � U0�21in
\ /
PLASTIC LAMIN�E COUNTER 0
Y
U
h—
36" A.F.F. WITO 1 1/20 EDGE
RECEPTION
& 4" BACKSPKH. I PL2
8'-0"
REFRIGERATOR i i REFRIGERATOR i rWATER
WD/GL
PROVIDED i PROVIDED i i COOLER I
WOOD
I BY TENANT. } I BY TENANT.
i I i I I PROVIDED I
P/P,FL,DB,CL,S
BY TENANT.1
203
BUILDING STANDARD
3'-0"
(TIMBERLAKE tAIIIFIELD OAK 1
`
4 TOFFEE) LO R �ABINETS
DISHWASHER
W/(1) ADJUiABLE SHELVES I
AND 4" WIREIPULLS. I
PROVIDED
i I I I i I
i I i I I I
BY TENANT.
U.
L -------------J L -------------J I I
FILE ROOM
BUILDING STANDARD
(TIMBERLAKE FAIRFIELD OAK
TOFFEE) UPPER CABINETS
W/(2) ADJUSTABLE SHELVES --
AND 4" WIRE PULLS.
I
N
PLASTIC LAMINATE COUNTER 0
36" A.F.F. WITH 1 1/2" EDGE
& 4" BACKSPLASH. PL1
BUILDING STANDARD
(TIMBERLAKE FAIRFIELD OAK
TOFFEE) LOWER CABINETS
W/(1) ADJUSTABLE SHELVES
AND 4" WIRE PULLS.
COFFEE AREA 201
g ELEVATION
A601 J SCALE: 1/2"=1'-0"
STAINLESS STEEL SINGLE
BOWL SINK W/ GOOSENECK
FAUCET AND PADDLE LEVERS.
L:a 7C— t —� = 7—L r,---------
REFRIGERATOR
STAINLESS STEEL SINGLE PROVIDED
BOWL SINK W/ GOOSENECK BY TENANT.
FAUCET AND PADDLE LEVERS
C�
Z m
O Z
WMi
Z
O
DOOR
FRAME
HARDWARE
�-
-_
J
Q
�
Q
M
i
L:a 7C— t —� = 7—L r,---------
REFRIGERATOR
STAINLESS STEEL SINGLE PROVIDED
BOWL SINK W/ GOOSENECK BY TENANT.
FAUCET AND PADDLE LEVERS
COAT ROD &
3 SHELF DETAIL
A601 SCALE: '1/2"=1'-0"
E
(TIMBERU
TOFFEE
W/(2) AD
A�
PLASTIC LAMINATE
36" A.F.F. WITH 1
& 4" BACKSPLASH.
BUILDING STANDARD
(TIMBERLAKE FAIRFIELD O
TOFFEE) LOWER CABINET
W/0) ADJUSTABLE SHED
AND 4" WIRE PULLS.
3/4" WHITE MELAMINE SHELF
3/4" WHITE MELAMINE TRIM
3/4"D WHITE MELAMINE END
SUUPPORTS (TYP. EACH END)
1-1/4" dia. CHROME ROD
NOTE:
WHERE SPAN EXCEEDS
4'-0" A CENTER SUPPORT
BRACKET IS TO BE USED
OFFICE 243
5 ELEVATION
A601 SCALE: 1/2"=1'-0"
DOOR SCHEDULE
C�
Z m
O Z
WMi
Z
O
DOOR
FRAME
HARDWARE
�-
-_
COAT ROD &
3 SHELF DETAIL
A601 SCALE: '1/2"=1'-0"
E
(TIMBERU
TOFFEE
W/(2) AD
A�
PLASTIC LAMINATE
36" A.F.F. WITH 1
& 4" BACKSPLASH.
BUILDING STANDARD
(TIMBERLAKE FAIRFIELD O
TOFFEE) LOWER CABINET
W/0) ADJUSTABLE SHED
AND 4" WIRE PULLS.
3/4" WHITE MELAMINE SHELF
3/4" WHITE MELAMINE TRIM
3/4"D WHITE MELAMINE END
SUUPPORTS (TYP. EACH END)
1-1/4" dia. CHROME ROD
NOTE:
WHERE SPAN EXCEEDS
4'-0" A CENTER SUPPORT
BRACKET IS TO BE USED
OFFICE 243
5 ELEVATION
A601 SCALE: 1/2"=1'-0"
DOOR SCHEDULE
C�
Z m
O Z
WMi
Z
O
DOOR
FRAME
HARDWARE
�-
\
-_
iIL
COAT ROD &
3 SHELF DETAIL
A601 SCALE: '1/2"=1'-0"
E
(TIMBERU
TOFFEE
W/(2) AD
A�
PLASTIC LAMINATE
36" A.F.F. WITH 1
& 4" BACKSPLASH.
BUILDING STANDARD
(TIMBERLAKE FAIRFIELD O
TOFFEE) LOWER CABINET
W/0) ADJUSTABLE SHED
AND 4" WIRE PULLS.
3/4" WHITE MELAMINE SHELF
3/4" WHITE MELAMINE TRIM
3/4"D WHITE MELAMINE END
SUUPPORTS (TYP. EACH END)
1-1/4" dia. CHROME ROD
NOTE:
WHERE SPAN EXCEEDS
4'-0" A CENTER SUPPORT
BRACKET IS TO BE USED
OFFICE 243
5 ELEVATION
A601 SCALE: 1/2"=1'-0"
DOOR SCHEDULE
C�
Z m
O Z
WMi
Z
O
DOOR
FRAME
HARDWARE
REMARKS
SIZE
J
Q
�
Q
M
O
Q
W
Q
<
W
Q
�
O
Q
W
N
1:73W �t-20tH
Y2(nCnnC��N�
UONO
��ado���o
11 11 11 It II II II II
CL c) m c��� n
J Vl � U0�21in
_
=
W
2
Y
U
h—
200
RECEPTION
203'-0
8'-0"
1 3/4'
WD/GL
D1
WOOD
D1
P/P,FL,DB,CL,S
SEE NOTE 5.
203
MAIL ROOM
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,S
—
204
FILE ROOM
3'-0'
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,CL,S
45 MIN. RATED
205
CONFERENCE
3'-0'
1 8'-0"
1 3/4"1
WOOD
D2
I HM
D2
PS,S
J
206
CONFERENCE
3'-0"
8'-0"
1 3/4'
WOOD
D2
HM
D2
PS,S
Of Sheets
208
COATS
203'-0
8'-0"
1 3/4'
WOOD
D3
HM
D3
DM,MG,S
209
OFFICE
3'-0'
8'-0"
1 3/4"
WOOD
D2
HM
D2
L'S
210
OFFICE
3'-0"
8'-0'
1 3/4"
WOOD
D2
HM
D2
L'S
213
OFFICE
S-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L'S
215A
BREAK ROOM
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,S,CL
2156
BREAK ROOM
S-0"
8'-0"
1 3/4*1
WOOD
D2
HM
D2
L,S,CL
216
OFFICE
3'-0"
8'-0"
1 3/4
WOOD
D2
HM
D2
PS,S
217
SERVER ROOM
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,CL,S
219
STORAGE
3'-0'
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,S
220
OFFICE
S-0"
8'-0"
1 3/4*1
WOOD
D2
HM
D2
L,S
221
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,S
222
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
LIS
223
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,S
224
OFFICE
S-0"
8'-0"
1 3/4*1
WOOD
D2
HM
D2
PS,S
225
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,S
226
OFFICE
3'-0'
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,S
227
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,S
229
OFFICE
3'-0"
8'-0"
1 3/4"1
WOOD
D2
HM
D2
PS,S
230
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,S
231
OFFICE
S-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,S
232
OFFICE
3'-0"
8'-0"
1 3/4
WOOD
D2
HM
D2
PS,S
233
OFFICE
S-0"
8'-0"
1 3/4!1
WOOD
D2
HM
PS,S
234
OFFICE
3'-0"
g'-0"
1 3/4"
WOOD
D2
HM
flD2
PS,S
235
STORAGE
3'-0"
8'-O"
1 3/4"
WOOD
D2
HM
PS,S
236
KITCHENETTE
3'-0'
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,CL,S
237
OPEN OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
I CL,S
238
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,S
239
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,S
240
OFFICE
S-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,S
241
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,S
242
OFFICE
3'-0"
g'-0"
1 3/4"
WOOD
D2
HM
D2
L'S
243A
OFFICE
S -O"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,S
2436
OFFICE
3'-0'
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,S
244
CONFERENCE
S-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,S
245
OPEN OFFICE
3'-0"
8'-0"
1 3/4"1
WOOD
D2
HM
D2
L,CL,S
246
OFFICE
S-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
PS,S
248
IT ROOM
3'-0"
8'-0"
1 3/4"
WOOD
D2
HM
D2
L,CL,S
2" WOOD CAP
TO MATCH DOOR
STAIN.
OFFICE 216
SOUTH WALL ELEVATION
A601 % SCALE 1/2a=1' -o'
P2
Architecture
Engineering
D
I
r
W4
Land Surveying
Corporate Office
(TIMBER
P2
OFFICE 216
SOUTH WALL ELEVATION
A601 % SCALE 1/2a=1' -o'
BUILDING STANDARD BY TENANT.
(TIMBERLAKE FAIRFIELD OM i I
TOFFEE) LOWER CABINETS 41 I
W/(1) ADJUSTABLE SHELVES I
AND 4" WIRE PULLS. I
3'-6" L 2'-6" L 3'-0" n L S-0-
-4
KITCHENETTE 236
6 ELEVATION
A601 SCALE- 1 /2"=1'-0"
D1
= FRAME
c�
w
x
ti z
�o
U
=3 LEVER
i HARDWARE
00
Q
DOOR/FRAME
ELEVATIONS
SCALE. 1/4'=1'-0'
TEMPERED
INSET
?E
STD.
E
ARE
DOOR SCHEDULE NOTES
1. ALL NEW DOORS ARE TO BE BUILDING STANDARD.
2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD
WHERE NEEDED.
3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION.
4. COORDINATE KEYING LOCKSETS WITH TENANT.
5. ENTRY DOORS #200 ARE TO BE STAINED TO MATCH EXISTING DOORS.
WOOD CHALK
RAIL TO MATCH
DOOR STAIN.
uke
NULTY CORPORA7toli
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: 317 808-6000
Fax: 317 808-6797
ILDING STANDARD
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
(TIMBER
KE FAIRFIELD OAK
C
0
a�
O
�
TOFFEE
UPPER CABINETS
C
.0
m
IY
\
/
\
W/(2) AD
USTABLE SHELVE
U
W
J
—
0
4" WIRE PULLS.
V
ca
—
—
— —
�Q o
_Z Z
\
a Z
a CM
0a
W U_
ca
C Z LcGd
PLASTIC LAMINATE
CONTER 0 -------- i
Q W
0
2
I
Z
r/
36 A.F.F. WITH 1
1 EDGE i
W
J
W
Cert `
1 Af>.,,�.�'Ll�
AR
& 4" BACKSPLAS
pL2 ;
Drawing Number:
A601
Of Sheets
Duke Job Number:
0000
A/E Job Number:
.
STAINLESS STEEL SINGLE
REFRIGERATOR i
BOWL SINK W/
FAUCET AND
GOOSENE
PADDLE LB
PROVIDED
BUILDING STANDARD BY TENANT.
(TIMBERLAKE FAIRFIELD OM i I
TOFFEE) LOWER CABINETS 41 I
W/(1) ADJUSTABLE SHELVES I
AND 4" WIRE PULLS. I
3'-6" L 2'-6" L 3'-0" n L S-0-
-4
KITCHENETTE 236
6 ELEVATION
A601 SCALE- 1 /2"=1'-0"
D1
= FRAME
c�
w
x
ti z
�o
U
=3 LEVER
i HARDWARE
00
Q
DOOR/FRAME
ELEVATIONS
SCALE. 1/4'=1'-0'
TEMPERED
INSET
?E
STD.
E
ARE
DOOR SCHEDULE NOTES
1. ALL NEW DOORS ARE TO BE BUILDING STANDARD.
2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD
WHERE NEEDED.
3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION.
4. COORDINATE KEYING LOCKSETS WITH TENANT.
5. ENTRY DOORS #200 ARE TO BE STAINED TO MATCH EXISTING DOORS.
WOOD CHALK
RAIL TO MATCH
DOOR STAIN.
uke
NULTY CORPORA7toli
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: 317 808-6000
Fax: 317 808-6797
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 2o0
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 OcovAht 2001
C
0
a�
O
�
TM
C
.0
m
IY
r
o
o
0
s
cn
U
W
J
M
0
W
V
ca
Cc
O
O
�Q o
_Z Z
0 V)
a Z
a CM
0a
W U_
ca
C Z LcGd
- 12f 4
JU �
Q W
0
2
Cw
Z
Q
Q
W
J
W
Cert `
1 Af>.,,�.�'Ll�
AR
Drawing Number:
A601
Of Sheets
Duke Job Number:
0000
A/E Job Number:
24198
2ND FLOOR
FINISH PLAN
SCALE: 1/80 = 1'-0"
GENERAL FINISH NOTES:
A. ALL DOORS TO BE FINISHED TO MATCH EXISTING DOORS.
B. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD.
C. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPORVAL OF ARCHITECT.
SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW.
D. CARPET TO CARPET ANDLOR CARPET TO HARDSURFACE FLOORING TRANSITIONS
TO BE FEATHERED AS RttQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE
A SMOOTH TRANSITION FROM FINISH TO FINISH
E. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE,
FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING
IN';TALLATION.
F. G.U. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND
VpNYL TILE TRANSITIONS TAKE PLACE.
G. W(RIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS.
IFI NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD.
H. PAINT NEW OR EXISTING PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT,
COLOR TO MATCH ADJACENT WALL FINISH.
1. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH
INFORMATION.
J. PAINT ALL EXPOSED MUAL SURFACES (ie. GRILLS HEATERS, AND FIRE
EXTINGUISHER CABINETS) TO MATCH ADJACENT SUhFACE.
K. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO
AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION.
FINISH PLAN NOTES:
Ft VCT TO BE INSTALLED IN RANDOM PATTERN, 33% VCT1, 33% VCT2, 337.VCT3.
F2 NEW FINISHES TO MATCH EXISTING CORRIDOR FINISHES.
F3 OPERABLE WALL VINYL TO BE SUBMITTED TO DESIGNER FOR SELECTION AND APPROVAL.
FINISH LEGEND:
FLOORCOVERINGS
�� CARPET – DIRECT GLUE
MFG: J & J INVISION
PATTERN: FLOORED (9143)
COLOR: 906, BOWLED OVER
c2 CARPET – DIRECT GLUE
MFG: J & J COMMERCIAL
PATTERN: LINK (2665)
COLOR: 1641, INTERNET
c3 CARPET – DIRECT GLUE
MFG: J & J COMMERCIAL
PATTERN: TEXTURES 36 (4655)
COLOR: NOON (1404)
vcTt VINYL COMPOSITION TILE
MFG: ARMSTRONG
PATTERN: STONTEX EXCELON
COLOR: 52149, COCOA BROWN
E2 VINYL COMPOSITION TILE
MFG: ARMSTRONG
PATTERN: STONTEX EXCELON
COLOR: 52139, LIMESTONE BEIGE
vCT3 VINYL COMPOSITION TILE
E�
MFG: ARMSTRONG
PATTERN: STONTEX EXCELON
COLOR: 52143, SANDSTONE TAN
BASE
gt VINYL BASE –4" COVE BASE
MANUFACTURER: JOHNSONITE
COLOR: 09, CLAY
WALLCOVERING
W1 MFG:LEN–TEX, MDC
PATTERN: MANHATTAN
COLOR: DELANCEY (4613–MN)
TYPE II
QUOTE #: 40094511
W2 MFG: VERSA, DL COUCH
PATTERN: CARIBE
COLOR: A47-187, FLAX
TYPE I
QUOTE #: DUKE2003
W3 MFG: VYCON, MDC
PATTERN: CONNECT
COLOR: SABLE BLANC, Y44815CT
TYPE 11
QUOTE #: 40094511
W4 MFG: MDC MEMERASE
PATTERN: WHITEWALL
COLOR: WHITE MWW-5401
PAINT QUOTE #: 40094511
P1 MFG: ICI
COLOR: 709, MANUSCRIPT
FINISH: EGGSHELL
P2 MFG: ICI
COLOR: 634, LA MESA
FINISH: EGGSHELL
P3 MFG: ICI
COLOR: 530, CAMELCOAT
FINISH: EGGSHELL
PLASTIC LAMINATE
F-P—L71 MANUFACTURER: NEVAMAR
COLOR: PAINTED WOODLANDS,PDG002T
FINISH: TEXTURED
PL2 MANUFACTURER: WILSONART
COLOR: SUNSTONE, 4781-60
Duke
Ii &W CONIMTioN
600 East 96th Street
Suite 100
Indianapolis IN 46240
Phone: 317 808-6000
Fax: 317 808-6797
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 OCOW qht 2001
c
0
.T
a�
D'
m
m'
-o
W
CO
\
Co
c
30
Y
cn
o
o
v
ozz Z
Q
aoV)0�
N 0 z d.
���Js
C0'O:
Z
� JQ
U U.
2
Cer ' 4VT�+rli
tMIM I 4
;STATS OF r
Drawing Number:
A801
Of Sheets
Duke Job Number:
0000
A/E Job Number:
24198
2!D FLOOR
ELECTRICAL/DATA PLAN
GENERAL ELECTRICAL NOTES:
E.
ROVIDE JUNCTION BOXES H
AS INDICATED ON PLANS.
PROVIDED BY THE TENANT
CONDUCTORS SHALL. BE INSTALLED IN CONDUIT.
CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL
TS TO BE COMPATIBLE WITH TENANT EQUIPMENT.
SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO
ELECTRICAL LOCATIONS AND CIRCUITING REQUIREMENTS WITH TENANT AND/OR
)EALERSHIP FOR SYSTEMS BASE FEED AND OR POWER POLES.
CONTRACTOR TO HARDWIRE FURNITURE TEM TO BUILDING POWER SOURCE.
AUJ RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS
ANDSHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH.
F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED ® 18" A.F.F. O NEW VOICE/DATA SUPPLY FOR SYSTEM FURNITURE.
UNLESS OTHERWISE NOTED. 0 NEW CORE DRILL OUTLET. VERIFY EXACT LOCATION WITH TENANT.
ELECTRICAL PLAN NOTES -
E1 PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY POWER
REQUIREMENTS WITH TENANT EQUIPMENT.
O NOT USED.
O NOT USED.
E4 PROVIDE POWER FOR TENANT SUPPLIED DISHWASHER.
O VERIFY EXACT LOCATION OF CORE DRILLS WITH TENANT AND/OR FURNITURE VENDOR.
ELECTRICAL LEGEND:
NEW DUPLEX WALL OUTLET
NEW QUADRAPLEX WALL OUTLET
(5D NEW DEDICATED CIRCUIT OUTLET
NEW DEDICATED 30 AMP 125 VOLT OUTLET.
dGFI NEW GROUND FAULT INTERRUPT CIRCUIT OUTLET
0 NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING)
O NEW JUNCTION BOX
!
NEW POWER SUPPLY FOR SYSTEM FURNITURE.
NEW CORE DRILL DATA OUTLET. VERIFY EXACT LOCATION WITH TENANT.
AWA
Duke
REALTY CORPORAnoN
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: 317 808-6000
Fax: 317 808-6797
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 eM 2001
0
Of
0
�
m
ili p
co
3
YW
v
U
N
d
0
C
L
U
z
Q
J
a
Zz Q
CIO
0 NoZo
Ix-
WU J J
C/) P. z w Q
V
Q ~
2 V
W
mi
W
Ce-:.' !�
�R0091DQ3&� �=
` WTAl E OF .��
G,```
Drawing Number:
E201
Of Sheets
Duke Job Number:
0000
A/E Job Number:
24198