Loading...
HomeMy WebLinkAbout04100275 Building Plans 2ELECTRICAL PLAN 1-A4 mall _ 11.01 NORTH ucncnML CLLU i ni pflL RU I Ca3 NOT ALL MAY APPLY. REFER TO ELECTRICAL PLAN FOR ADDITIONAL NOTES AND ELECTRICAL INFO. 1. THIS DRAWING IS INTENDED TO PROVIDE INFORMATION RELATING TO THE LOCATION OF WIRING DEVICES AND OUTLETS ONLY. IT IS THE RESPONSIBILITY OF THE ELECTRICAL DESIGN/BUILD CONTRACTOR TO PROVIDE NECESSARY DOCUMENTS RELATING TO THE ACTUAL ELECTRICAL INSTALLATION AND TO INSTALL ALL WIRING DEVICES IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES. 2. ALL DIMENSIONS ARE FROM FINISHED WALL SURFACE OR COLUMN CENTERLINE TO CENTERLINE OF OUTLETS OR CENTERLINE OF PAIRS OF OUTLETS. 3. ALL WALL MOUNTED WIRING DEVICES AND RECEPTACLES SHOWN BACK TO BACK SHALL BE OFFSET A MINIMUM OF 8" AND ACOUSTICALLY SEALED. 4. WHERE DIRECT CONNECTION TO PREWIRED FURNITURE PANELS OCCURS, PROVIDE POWER AND TELECOMMUNICATION FEEDS TO INDICATED PANEL LOCATION FROM WALL, COLUMN OR FLOOR SOURCE DIRECTLY ADJACENT TO THIS LOCATION. 5. ALL EXISTING FLOOR MOUNTED ELECTRICAL/TELECOMMUNICATION DEVICES WHICH ARE NOT REUSED ARE TO BE REMOVED. REMOVE ALL ASSOCIATED CABLE, WIRE AND CONDUIT BACK TO SOURCE. PROPERLY PATCH AND REPAIR AFFECTED FLOOR AREA. g. UNLESS OTtiERWISE NOTED ALL DEVICE ELEVATIONS INDICATED ON ELECTRICAL PLAN REFER TO BOTTOM OF OUTLET. 7. REFER TO REFLECTED CEILING PLANS FOR LOCATIONS OF LIGHT SWITCHES. 8. USE GROUND FAULT INTERUPT (G.F.I.) OUTLETS IN THE VICINITY OF ANY WET AREAS (KITCHENS, BREAK ROOMS, RESTROOMS, JANITORIAL ROOMS WITH FLOOR SINKS, LAUNDRY ROOMS, STAND ALONE WALL MOUNTED SINKS, ELECTRIC WATER FOUNTAINS, ETC.). SEE ELECTRICAL LEGEND. 220 ELECTRICAL LEGEND REFER TO ELECTRICAL PLAN FOR ADDITIONAL NOTES AND ELECTRICAL INFO. BULDING STANDARD ELECTRICAL INDICATES NEW ITEM LOCATION JUUCTION BOX. N AS SHOWN. SEE NOTE BELOW. BULDING STANDARD WALL MOUNTED DUDLEX OUTLET. 220 OUTLET BUILDING STANDARD WALL MOUNTED FOUR-PLEX ELECTRICAL OUTLET. BLILDING STANDARD WALL MOUNTED DEDICATED DUPLEX OUTLET. BULDING STANDARD WALL MOUNTED DATA LINE OUTLET BUILDING STANDARD WALL MOUNTED TE-EPHONE OUTLET W MOUNTED TELEPHONE AND DATA LINE SHARED OUTLET. GFI INDICATES GROUND FAULT INTERRUPT OUTLET. SPECIAL MOUNTING HEIGHT INDICATION +42^ FOR WALL OUTLETS. TAKEN TO BOTTOM OF PLATE. NOTE: UNLESS NOTED WITH AN "R" OR AN "N", ALL ITEMS WILL BE EXISTING TO REMAIN. (R) n tl- tic CARSON DESIGN AS90CIA7'ES TEL 317.8435979 FAX 317.8435975 2325 POINTE PARKWAY SUrM 200 CARMEL INDIANA 46032 TEL 511977.0520 FAX 511977.0384 12301 RESEARCH BLVD. BUILDING IV, SUrrE 104 AUSTIN TEXAS 78759 THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO 9E USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP Z O Z a W m jZ.Sc.4^_7'�lf1�a.:.',� N Lu Lu LTJ ICY) O W F- ry- CARSON DESIGN AS90CIA7'ES TEL 317.8435979 FAX 317.8435975 2325 POINTE PARKWAY SUrM 200 CARMEL INDIANA 46032 TEL 511977.0520 FAX 511977.0384 12301 RESEARCH BLVD. BUILDING IV, SUrrE 104 AUSTIN TEXAS 78759 THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO 9E USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP Z O Z a W t/a Ca Z DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: ELECTRICAL PLAN JOB NO. 0420608 10/14/2004 SHEET NUMBER: A4 SHEET OF m F-- N Lu Lu LTJ ICY) O W F- ry- co d' u -i Q v z C -D = o Lu F- z z Lu -LL 2E cc ry- L0 CNJ Q N Q U U T t/a Ca Z DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: ELECTRICAL PLAN JOB NO. 0420608 10/14/2004 SHEET NUMBER: A4 SHEET OF WALL TYPE NOTES UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLANS ALL WALLS TO BE WALL TYPE #1. NOTE; REFER TO ROOM FINISH SCHEDULE FOR WALL BASE TYPES AS WELL AS CEILING TYPES AND CEILING HEIGHTS. NOTE; PROVIDE CONTROL JOINTS IN ALL METAL STUD/ GYP BOARD WALLS AT 30'-0" MAXIMUM SPACING. AT RATED WALLS STUFF CONTROL JOINT FULL WITH SOUND ATTENUATION FIRE BLANKET. COORDINATE LOCATIONS OF CONTROL JOINTS WITH ARCHITECT PRIOR TO PLACEMENT. REFER TO FLOOR PLANS FOR LOCATION OF EACH INDIVIDUAL WALL TYPE, WALL TYPE #5 ATTACH METAL STUDS TO UNDERSIDE OF STRUCTURE. PROVIDE CONTINUOUS DEEP LEG TRACK. SUSPENDED ACOUSTICAL CEILING TILE. RE: ROOM FIN. SCHED. FOR INFO. FILL WALL SOLID WITH SOUND ATTENUATION BATTS INSULATION IN THICKNESS TO MATCH REQUIRED METAL STUD SIZE. 6" METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. FLOOR LINE WALL TYPE #4 WALL TYPE #411 - NO CEILING SUSPENDED ACOUSTICAL TILE 2-1/2"METAL FURRING CHANNEL ® 16" O.C. EXISTING CONCRETE BLOCK WALL 5/8"THK. GYPSUM BOARD ATTACH METAL STUDS TO UNDERSIDE OF STRUCTURE. PROVIDE CONTINUOUS DEEP LEG TRACK. SUSPENDED ACOUSTICAL CEILING TILE. RE: ROOM FIN. SCHED. FOR INFO. FILL WALL SOLID WITH SOUND ATTENUATIOI` BATTS INSULATION IN THICKNESS TO MATCH REQUIRED METAL STUD SIZE. 3-5/8" METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. FLOOR LINE WALL TYPE #3 WALL TYPE #311 - NO CEILING ON ONE SIDE WALL TYPE #3C - NO CEILING ON EITHER SIDE, NO INSULATION SCOPENOTES APPLICABLE BUILDING CODES 2003 INDIANA BUILDING CODE (2000 INTERNATIONAL BUILDING CODE W/ AMMENDMENTS) 2003 INDIANA FIRE CODE (2000 INTERNATIONAL FIRE CODE W/ AMMENDMENTS) 1999 INDIANA PLUMBING CODE (1997 UNIFORM PLUMBING CODE W/ AMMENDMENTS) ADA ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES EXISTING BUILDING AREA MORE STRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY PROTECTED FROM DAMAGE OF ANY KIND. SHALL ARRANGE FOR USAGE OF THE FREIGHT PRINTF D MATTER TO THE OWNER AT THE EXISTING CONDITIONS CONTRACTORS NOTED, BUT REQUIRED FOR PROPER THE CONTRACTOR SHALL BE RESPONSIBLE ELEVATOR [OR SUCH ELEVATOR DESIGNATED]. IF DELIVERY OF BUILDING MATERIALS INVOLVES TIME SUBSTANTIAL COMPLETION. THE CONTRAA CTOR SHALL INSTRUCT THE CHANGE ORDERS RESPONSIBILITIES INSTALLATION SHALL BE FURNISHED AND FOR FIELD VERIFYING ALL EXISTING WORK THE USE OF FACILITIES OTHER THEN THE OWNER OR OWNER'S ALLOWABLE TRAVEL DISTANCE INSTALLED BY THE CONTRACTOR(S). WHICH IS TO REMAIN, AND DETERMINING WHETHER AVAILABLE ELEVATORS, THE CONTRACTOR REPRESENTATIVE IN THE PROPER PROPS R USE OF THE EQUIPMENT FURNISHED RE: ALL SHEETS ■ RE. ALL SHEETS ALL WORK SHALL BE WARRANTED OR NOT IT CAN BE REPAIRED AND/OR RECONDITIONED TO MATCH AND SHALL COORDINATE SUCH ACTIVITIES IN SUCH BY THEIR TRADE. 140.24" = f11'-6 1/4" PROVIDED EXITS SATISFACTORY, IN MATERIALS AND BLEND WITH NEW MATERIALS AND A MANNER WHICH POSES NO HAZARD TO PLASTIC LAMINATE EXISTING CONDITIONS SHOWN ON THESE SHOULD THERE BE ANY QUESTIONS WORKMANSHIP, FOR A MINIMUM PERIOD COMPONENTS. HE SHALL OBTAIN THE ANY PERSONNEL WITHIN OR AROUND THE GENERAL CONTRACTOR IS TO PROVIDE A DRAWINGS ARE BASED UPON BASE REGARDING THE CONTRACT DOCUMENTS, OF ONE (1) YEAR, OR FOR THE PERIOD OF OWNER'S APPROVAL OF THE SCOPE AND BUILDING OR BUILDING SITE. THOROUGH CONSTRUCTION CLEAN-UP AT BUILDING OR OTHER CONSTRUCTION EXISTING CONDITIONS, AND/OR DESIGN WARRANTY CUSTOMARY, OR STIPULATED FOR, LIMIT OF SAID WORK PRIOR TO STARTING QT CLOSE-OUT, INCLUDING VACUUMING AND DOCUMENTS MADE AVAILABLE TO THE INTENT, THE CONTRACTOR SHALL BE THE TRADE, CRAFT, OR PRODUCT, WHICHEVER CONSTRUCTION. NO CHANGE ORDERS SHALL ALL CONTRACTOR OR SUPPLIER REQUESTS FOR CLEANING ALL CARPETING. ARCHITECT BY THE BUILDING OWNER. RESPONSIBLE FOR OBTAINING A IS LONGER. THEREFORE ONLY COMPETENT BE ACCEPTED FOR COMPLETED WORK THAT SUBSTITUTIONS OF SPECIFIED ITEMS SHALL RETURN AIR UNLESS OTHERWISE NOTED, AS -BUILT CLARIFICATION FROM THE ARCHITECT PRIOR TO MECHANICS CAPABLE OF PRODUCING GOOD DOES NOT CONFORM TO THE STANDARDS BE SUBMITTED IN WRITING, ACCOMPANIED DESIGN ARCHITECTURAL CONDITIONS HAVE NOT BEEN BID SUBMITTAL AND PROCEEDING WITH WORKMANSHIP CUSTOMARY TO THE TRADE ESTABLISHED AT THE TIME OF BID BY THE ALTERNATIVE PRODUCT INFORMATION, TO THE ARCHITECT. ALL SUBSTITUTIONS COMPLIANCE REVIEW FIELD VERIFIED AND MAY VARY FROM THOSE ANY WORK, OR RELATED WORK, IN SHOULD BE USED. COMMENCING WORK ACCEPTANCE. REFR REFRIGERATOR SHOWN. QUESTION. BY A CONTRACTOR OR SUBCONTRACTOR CONTRACTOR SHALL BE RESPONSIVE SHALL BE SUBMITTED TO THE ARCHITECT, NOTHE LATER THAN (10) WORKING DAYS PRIOR TO RE: ALL SHEETS PRIORTOSUBMITTING THE THESE CONTRACT DOCUMENTS ARE ACCEPTANCE OF THE CONDITIONS AND SURFACE CONCERNED. IF FOR FAMILIARIZING HIMSELF WITH THE BID OPENING DATE. SUBSTITUTIONS SHALL ONLY ROUGH OPENING CONTRACTOR SHALLBECONSTITUTES RESPONSIBLE FOR FIELD VERIFYING ALL INTENDED TO DESCRIBE ONLY THE SCOPE ANY SUCH CONDITIONS ARE UNACCEPTABLE, PROJECT SCOPE OF WORK, BUILDING BE CONSIDERED ONLY IF THEY DO NOT THE CONTRACTOR SHALL SUBMIT SHOP EXISTING CONDITIONS AND ANY CRITICALSTANDARDS, AND APPEARANCE OF THE REAL PROPERTY THE GENERAL CONTRACTOR SHOULD BE SCHEDULE AND DEADLINE SACRIFICE QUALITY, APPEARANCE, AND DRAWINGS OF CUSTOM MILLWORK, CUSTOM DIMENSIONS ASSOCIATED C TED WITH THE IMPROVEMENTS, INCLUDING THETHE NOTIFIED AT ONCE AND NO WORK DONE CONTRACTOR SHALL FURTHER BE FUNCTION. UNDER NO CIRCUMSTANCES WILL FABRICATION OR MANUFACTURE, AND PROPOSED WORK. THE CONTRACTOR SHALL PERFORMANCE AND LEVEL OF QUALITY UNTIL CONDITIONS ARE ACCEPTABLE. RESPONSIBLE FOR ADVISING THE OWNER OF THE OWNER BE REQUIRED TO PROVE THAT A PHYSICAL SAMPLES OF ALL FINISH CONFIRM THAT ALL WORK OUTLINED WITHIN EXPECTED OF ITS COMPONENTS. IT IS LAM ALL LONG LEAD TIME ITEMS AFFECTING THE PRODUCT PROPOSED FOR SUBSTITUTION IS OR MATERIALS SPECIFIED TO THE ARCHITECT FOR THESE DOCUMENTS MAY BE ACCOMPLISHED INCUMBENT UPON THE CONTRACTOR TO THE CONTRACTOR SHALL COORDINATE WITH PROJECT SCHEDULE AND SHALL, UPON IS NOT OF EQUAL QUALITY TO THE PRODUCT REVIEW AND APPROVAL BY THE OWNER. AS SHOWN, PRIOR TO THE COMPLETION OF INSURE THAT ALL WORK COMPLETED AND THE OWNER, OR THEIR AUTHORIZED AGENT, REQUEST FROM THE OWNER, SUBMIT ORDER CONFIRMATIONS AND DELIVERY DATES FOR SPECIFIED. REVIEWED SHOP DRAWINGS AND THE BIDDING PROCESS, AND SHALL NOTIFY MATERIALS INSTALLED BE IN FULL COMPLIANCE, AS A MINIMUM STANDARD, TO DETERMINE ALL EXISTING MATERIALS TO BE SALVAGED AND RETAINED BY THE SUCH LONG LEAD TIME ITEMS TO THE UNDER NO CIRCUMSTANCES SHALL THE SCHEDULES PREPARED BY OTHERS SHALL NOT BOTH THE ARCHITECT AND THE BUILDING OWNER OF ANY CONDITIONS ENCOUNTERED WITH ALL APPLICABLE CODES, REGULATIONS OWNER. THE CONTRACTOR SHALL REMOVE OWNER. CONTRACTOR SCALE THE DRAWINGS TO BE CONSTRUED TO BE PART OF THE WHICH MAY EFFECT BUILDING CODEDETERMINE AND ORDINANCES HAVING JURISDICTION. SALVAGEABLE MATERIALS FROM THE SPACE THE CONTRACTOR SHALL COORDINATE WITHASSUMES THE DIMENSIONS. SEE FLOOR CONTRACT DOCUMENTS, AS THE ARCHITECT COMPLIANCE. LIFE SAFETY AND ISSUANCE THESE AND STORE IN A LOCATION AS DIRECTED BY THE BUILDING OWNER ACCESS TO THE PLAN FOR DIMENSION LOCATIONS. NO RESPONSIBILITY FOR DRAWINGS, SCHEDULES AND/OR OF A CERTIFICATE OF OCCUPANCY, THE CONTRACT DOCUMENTS NOT ATTEMPT TO INSTRUCT THE CONTRACTOR IN THE OWNER. ALL OTHER MATERIALS RUBBISH, AND DEBRIS, SHALL BE REMOVED SPACE AND THE ONGOING CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE SPECIFICATIONS FOR WORK ON THE PROJECT TIMELY COMPLETION FOR THE PROJECT OR ESTABLISHED BUDGET OF SUCH WORK.AND THE DETAILS OF HIS TRADE. THEY ARE PROMPTLY DISPOSED OF BY THE WORK. DISRUPTIVE OR POTENTIALLY HAZARDOUS CONSTRUCTION ACTIVITIES SHALL FOR THE INSTALLATION OF ALL SELECTED PREPARED OR ACCOMPLISHED BY OTHERS. EXIS PERFORMANCE SPECIFICATIONS IN THAT THEY CONTRACTOR AT AN OFFSITE LOCATION. THE BE COORDINATED TO OCCUR AFTER NORMAL MATERIALS WHICH SHALL BE COMPLETE IN THE ARCHITECT WILL REVIEW THE NO ADDITIONAL FUNDS WILL BE APPROVED DO REQUIRE THAT ALL MANUFACTURED CONTRACTOR SHALL TAKE ALL NECESSARY OFFICE HOURS, SO AS TO MINIMIZE ALL RESPECTS PRIOR TO THE FINAL DRAWINGS AND SAMPLES FOR CONFORMITY FOR WORK OMITTED FROM THE ITEMS, MATERIALS AND EQUIPMENT BE PRECAUTIONS TO ASSURE THAT ALL PROPERTY DISTURBANCE TO BUILDING OCCUPANTS. ACCEPTANCE, UNLESS OTHERWISE NOTED. WITH THE CONSTRUCTION BID DUE TO LACK OF INSTALLED IN STRICT ACCORDANCE WITH THE IMPROVEMENTS I.E. PARTITIONS DOORS NOT IN CONTRACT TYP INFORMATION CONTAINED IN THE CONSTRUCTION DOCUMENTS, AND RETURN VERIFICATION BY THE CONTRACTOR, EXCEPT MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT IN THE CASE FRAMES, CABINETS, CEILING GRID, CEILING THE CONTRACTOR SHALL COORDINATE WITH THE CONTRACTOR SHALL PRESERVE ALL PRINTED INSTRUCTIONS AND WARRANTIES THE SUBMITTALS TO THE CONTRACTOR WITHIN AS OTHERWISE APPROVED BY THE OWNER FOR WORK ASSOCIATED WITH "HIDDEN" WHERE THE CONTRACT DOCUMENTS ARE TILE, AND THE ELECTRICAL AND MECHANICAL DEVICES, ETC.] WHICH ARE TO REMAIN, ARE THE BUILDING OWNER FOR DELIVERY TO THE SPACE OF ALL BUILDING MATERIALS, AND THAT ARE PROVIDED WITH EQUIPMENT OR FIVE 5 WORKING DAYS OF RECEIPT, EXCEPT CONDITIONS NOT ACCESSIBLE PRIOR TO MATERIALS USED, AND DELIVER SAID ASMAY OTHERWISE BE PROVIDED CONSTRUCTION. FOR BY THE OWNER. CODE SUMMARY APPLICABLE BUILDING CODES 2003 INDIANA BUILDING CODE (2000 INTERNATIONAL BUILDING CODE W/ AMMENDMENTS) 2003 INDIANA FIRE CODE (2000 INTERNATIONAL FIRE CODE W/ AMMENDMENTS) 1999 INDIANA PLUMBING CODE (1997 UNIFORM PLUMBING CODE W/ AMMENDMENTS) ADA ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES EXISTING BUILDING AREA (1) STORY = 76,735 S.F. TENANT AREA(S) ASSEMBLY SPACE = 5,784 S.F. OUTSIDE DIAMETER OFFICE/ACCESSORY SPACE = 10,885 S.F. ACOUSTICAL CEILING TILE TOTAL TENANT AREA = 16,669 S.F. OCCUPANCY TENANT = A-3 OPENING EXISTING BUILDING = B CONSTRUCTION TYPE TYPE V—B OCCUPANCY AUTOMATIC FIRE YES (EXISTING) SUPPRESSION SYSTEM AWT ALLOWABLE TRAVEL DISTANCE 250'-0" OCCUPANT LOAD FACTOR ASSEMBLY SPACE: 7 S.F./OCCUPANT BASED ON FLOOR AREA OFFICE/ASSEMBLY SPACES: 100 S.F./OCCUPANT OCCUPANT LOAD ASSEMBLY SPACE = 826 FLOOR DRAIN OFFICE/ASSEMBLY SPACES = 108.9 TOTAL OCCUPANT LOAD = 934.9 REQUIRED EXIT WIDTH (DOOR WIDTH=.15 /OCCUP.) 140.24" = f11'-6 1/4" PROVIDED EXITS (6) DOORS © 3'-0" EACH = 18'-0" AND EGRESS TOTAL SUITE NOTE: THIS PROJECT DOES NOT INCLUDE THE CONSTRUCTION OF ADDITIONAL BUILDING AREA. EXISTING 8" CMU WALL (2 -HR RATED). ALL WALL JOINTS AND PENETRATIONS SHALL BE SEALED WITH APPROVED U.L. LISTED 'F' AND 'T' SYSTEMS. G.C. TO VERIFY EXISTING RATED WALL IS CONTINUOUS FROM EXISTING FLOOR TO EXISTING ROOF STRUCTURE. SUBMIT PRODUCT DATA AND INSTALLAATION INFORMATION PRIOR TO INSTALLATION FOR ARCHITECTS APPROVAL. c� z z Lu a. 0 c� ZD 0 0 0 0 Of 0 0 z U- C) ct: m m SAFETY PLAN NO SCALE EXIT m Marl -_ER TO FLOOR PLANS FOR WALL TYPES. AL STUD RUNNER BETWEEN VERT STUDS. II RECESSED FIRE EXTINGUISHER CABINET. ER TO FLOOR OR CODE PLANS FOR ATIONS. ANCHOR CABINET TO DOUBLE DS AT JAMBS. DD SHIMS AS REQ'D AT SILL & JAMBS. NOTE; COORDINATE MINIMUM REQUIRED WALL THICKNESS WITH FIRE a EXTING. CABINET MANU PRIOR TO PURCHASE. SIZE AND TYPE OF EXTINGUISHER MUST MEET ALL LOCAL AND STATE CODE REQUIREMENTS. SEMI -RECESSED F.E. CABINET 10 NO SCALE EXIT EXIT z z W SOUND BATT INSU. ABOVE CEIL. 2'-0" EA. SIDE OF WALL CENTER. SUSPENDED ACOUSTICAL CEILING TILE. RE: ROOM FIN. SCHED. FOR INFO. CHICAGO METALLIC ELIMINATOR TRACK. BUILT IN TRIM EDGE W/ 3/4" PROTECTIVE TAPE. FLAT TAPE ONLY. SPACKLE AND SAND. FILL WALL SOLID WITH SOUND ATTENUATI( BATTS INSULATION IN THICKNESS TO MATCH REQUIRED METAL STUD SIZE. 3-5/8" METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. FLOOR LINE WALL TYPE #2 WALL TYPE #1 12254 HANCOCK ST CARMEL, IN 46032 122ND ST. / �I SITE MAP RTH NO SCALE .W DOOR FRAME. REFER TO DOOR IISH SCHEDULE FOR TYPE OR USE 11LDING OWNER STANDARDS. :W INTERIOR WALL CONSTRUCTION. FER TO FLOOR PLANS FOR TYPE. NEW DOOR FRAME. REFER TO DOOR FINISH SCHEDULE FOR TYPE OR USE BUILDING OWNER STANDARDS, NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. NOTE; UNLESS OTHERWISE NOTED OR DIMENSIONED ON PLANS PROVIDE 4" OF SPACE AT HINGE SIDE OF ALL DOOR FRAMES. TYPICAL DOOR JAMB REQUIREMENTS 1 C NO SCALE DDn IC'rT I Or'ATIMI SUSPENDED ACOUSTICAL CEILING TILE. RE: ROOM FIN. SCHED. FOR INFO. CHICAGO METALLIC ELIMINATOR TRACK. BUILT IN TRIM EDGE W/ 3/4 PROTECTIVE TAPE. FLAT TAPE ONLY. SPACKLE AND SAND. 3-5/8" METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE FLOOR LINE SHEET INDEX INDEX SHEET SHEET AO.B ABBREVIATIONS SHEET Al A.F.F. ABOVE FINISHED FLOOR FD FLOOR DRAIN OD OUTSIDE DIAMETER ACT ACOUSTICAL CEILING TILE FIN FINISH OPNG OPENING APP APPROXIMATE FLR FLOOR OPP OPPOSITE AWT ACOUSTICAL WALL TREATMENT FT FEET O.H. OPPOSITE HAND BLKG BLOCKING FD FLOOR DRAIN 0 TO 0 OUT TO OUT B.O. BOTTOM OF FE FIRE EXTINGUISHER PL LAM PLASTIC LAMINATE BOT BOTTOM FEC FIRE EXTINGUISHER CABINET PLWD PLYWOOD CAB CABINET GA GAUGE PS PROJECTION SCREEN CAR CARPET GB GRAB BAR QT QUARRY TILE CJ CONTROL JOINT GWB GYPSUM WALLBOARD R RISER CL CENTER LINE HDWR HARDWARE RA RETURN AIR CMU CONCRETE MASONRY UNIT H. HIGH/HEIGHT RB RESILIENT BASE COL COLUMN HM HOLLOW METAL REF REFERENCE CONIC CONCRETE HORIZ HORIZONTAL REFR REFRIGERATOR CONST CONSTRUCTION HVAC HEATING, VENTILATING, AIR COND. REQD REQUIRED CONT CONTINUOUS HW HOT WATER RO ROUGH OPENING CT CERAMIC TILE JST JOIST 1T1 CW COLD WATER JT JOINT SA SUPPLY AIR DP DEEP/DEPTH KIT KITCHEN SCHED SCHEDULE DET DETAIL SEC SECTION DF DRINKING FOUNTAIN LAM LAMINATE SIM SIMILAR DIM DIMENSION LAV LAVATORY SPECS SPECIFICATIONS DWG DRAWING LLH LONG LEG HORIZONTAL SF SQUARE FOOT DWC DRINKING WATER COOLER LLV LONG LEG VERTICAL SA SUPPLY AIR EA EACH MAS MASONRY SS STAINLESS STEEL EJ EXPANSION JOINT MAX MAXIMUM STD STANDARD EL ELEVATION MB MARKER BOARD STL STEEL EIFS EXTERIOR INSULATION FINISH SYSTEM MECH MECHANICAL SUSP SUSPENDED E.T.R. EXISTING TO REMAIN MEZZ MEZZANINE TB TACK BOARD EXIS EXISTING MFG MANUFACTURER TEL TELEPHONE EXP EXPANSION MIN MINIMUM T.O. TOP OF EXT EXTERIOR M.O. MASONRY OPENING TV TELEVISION N.I.C. NOT IN CONTRACT TYP TYPICAL 12254 HANCOCK ST CARMEL, IN 46032 122ND ST. / �I SITE MAP RTH NO SCALE .W DOOR FRAME. REFER TO DOOR IISH SCHEDULE FOR TYPE OR USE 11LDING OWNER STANDARDS. :W INTERIOR WALL CONSTRUCTION. FER TO FLOOR PLANS FOR TYPE. NEW DOOR FRAME. REFER TO DOOR FINISH SCHEDULE FOR TYPE OR USE BUILDING OWNER STANDARDS, NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. NOTE; UNLESS OTHERWISE NOTED OR DIMENSIONED ON PLANS PROVIDE 4" OF SPACE AT HINGE SIDE OF ALL DOOR FRAMES. TYPICAL DOOR JAMB REQUIREMENTS 1 C NO SCALE DDn IC'rT I Or'ATIMI SUSPENDED ACOUSTICAL CEILING TILE. RE: ROOM FIN. SCHED. FOR INFO. CHICAGO METALLIC ELIMINATOR TRACK. BUILT IN TRIM EDGE W/ 3/4 PROTECTIVE TAPE. FLAT TAPE ONLY. SPACKLE AND SAND. 3-5/8" METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE FLOOR LINE SHEET INDEX NEW PARTITIONS TO BE CONSTRUCTED DESIGNATES INTERIOR WALL CONST. X TY�,REFER TO FLOOR PLANS FOR LOCATIONS. REFER TO WALL TYPES ON THIS SHEET FOR ACTUAL WALL CONSTRUCTION. NOTE: ALL WALLS ARE W1 UNLESS OTHERWISE NOTED. INDEX SHEET SHEET AO.B CONSTRUCTION PHASING PLAN SHEET Al DEMOLITION PLAN SHEET A2 CONSTRUCTION PLAN SHEET A3 REFLECTED CEILING PLAN SHEET A4 ELECTRICAL PLAN SHEET A5 FINISH PLAN SHEET A8 DETAILS, ELEVATIONS & DOOR SCHEDULE U WALL LEGEND - EXISTING PARTITIONS TO X REMAIN. VERT EXISTING PARTITIONS TO BE O REMOVED. SEE DEMO DRAWING. NEW PARTITIONS TO BE CONSTRUCTED DESIGNATES INTERIOR WALL CONST. X TY�,REFER TO FLOOR PLANS FOR LOCATIONS. REFER TO WALL TYPES ON THIS SHEET FOR ACTUAL WALL CONSTRUCTION. NOTE: ALL WALLS ARE W1 UNLESS OTHERWISE NOTED. METROPOLITAN INDIANAPOLIS VICINITY MAP NORTH NO SCALE MATCH NEW WALL TYPE WITH EXISTING WALL CONSTRUCTION TO REMAIN. EXISTING COLUMN WITH WRAP. UNLESS OTHERWISE NOTE' ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE ADJACENT COLUMN WRAP TYPICAL WALL ALIGNMENT PLAN TYPICAL DETAILS NOT ALL MAY APPLY 1 NO SCALE ANY EXISTING CONSTRUCTION (WALL, COLUMN WRAP, ETC) TO REMAIN. UNLESS OTHERWISE NOTED OR DIMENSIONED ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE OF ADJACENT EXISTING CONSTRUCTION TO REMAIN. NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. ANY EXISTING CONSTRUCTION (WALL, COLUMN WRAP, ETC) TO REMAIN. UNLESS OTHERWISE NOTED OR DIMENSIONED ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE OF ADJACENT EXISTING CONSTRUCTION TO REMAIN. NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. 1B NO SCALE NORTH PROPERTY MANAGER DATE DATE CARSON DESIGN ASSOCIATES DATE UPON EXECUTION, THE CLIENT AND PROPERTY MANAGER APPROVE ALL ASPECTS OF THE SCOPE OF WORK SHOWN IN THESE DOCUMENTS, INCLUDING DESIGN CONTENT, SCOPE OF CONSTRUCTION AND FINISH SELECTION FOR THE FOLLOWING PHASE: ❑ SPACE PLANNING ❑ PRELIMINARY PRICING CONSTRUCTION DOCUMENTATION 1:1 ALL COSTS INCURRED DUE TO MISINTERPRETATION OF THESE DOCUMENTS OR ANY CHANGES TO THE PROJECT REQUESTED AFTER SIGN -OFF SHALL NOT BE THE RESPONSIBILITY OF CARSON DESIGN ASSOCIATES AND SHALL BE THE SOLE RESPONSIBILITY OF THE CLIENT. TYPICAL WALL @ MULLION DETAIL NEW OR EXISTING WINDOW MULLION BLACK NEOPRENE SEAL ADHERED TO FACE OF MULLION AND SILL CAP AT ALL EXPOSED SURFACES ADJACENT TO ALUMINUM CHANNEL. ALUMINUM BRAKE METAL CHANNEL W/EDGES RETURNED (COLOR TO MATCH WINDOW FRAMING SYSTEM). EDGE OF SILL BELOW, WALL CONSTRUCTION (REF. TO FLOOR PLAN) CENTER ON WINDOW MULLION )E TIGHT FIT WHERE WALL IS COPED ff WINDOW SILL CONSTRUCTION. 1A CARSON DESIGN ASSOCIATES TEL 317.843.5979 `AX 317.843.5975 2325 POINTE PARKWAY SUITE 200 CAtnMEL INDIANA 46032 TEL S 12.977.0520 FAX :;12.977.0384 12301 ESEARCH BLVD. BUILDI G N, SUITE 104 AUSTIN -EXAS 78759 www.cam ickWgn.com THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP w E SYMBOL LEGEND UON UNLESS OTHERWISE NOTED cn „ 4 z �z 3�; UR URINALO O 4 C KEYED NOTE N U nO U REFER TO DRAWING WHERE SHOWN, VCT VINYL COMPOSITION TILE X WALL TYPE. SEE PLANS FOR LOCATION VERT VERTICAL O O :> SEE THIS SHEET FOR CONSTRUCTION. VT VINYL TILE C E A U C- o y O WINDOW TYPE, SEE PLANS FOR LOCATION W. WIDE/WIDTH a REFER TO WINDOW SCHEDULE. W/ WITH W DOOR NUMBER. REFER TO WHO WITHOUT Cy) XXX o DOOR SCHEDULE WB WOOD BASE Q z WC WATER CLOSET OFFICE ROOM NAME, SIZE AND NUMBER. REFER WD WOOD C') U' TO ROOM FINISH SCHEDULE WH WP WATER HEATER WORKING POINT m =Cid m 2> tTl m ELEVATION NUMBER m> W p -n - co, E u n- -Cl a SHEET NUMBER "0 75 v ti SECTION NUMBER ;m I O N 1•+ V G z1 SHEET NUMBER U ` E C 1T1 c c d 6"�% m �C C, LARGED PLAN l V i d fes, OJ ` FINISH NOTE. REFER TO ROOM y < (� z 0 > i. FINISH LEGEND AND/OR FINISH PLAN. III5;11 p: ION oU ro rl z !> m �n N, -�- ELEVATION TARGET SEMI -RECESSED FIRE EXTINGUISHER/ FEC CABINET TO BE PROVIDED/INSTALLED BY G.C. plkill SEE DETAIL THIS SHEET. PAINT M U: CABINET TO MATCH DOOR FRAMES. (FE DENOTES FIRE EXTING. NO CABINET.) DOCUMENT APPROVAL METROPOLITAN INDIANAPOLIS VICINITY MAP NORTH NO SCALE MATCH NEW WALL TYPE WITH EXISTING WALL CONSTRUCTION TO REMAIN. EXISTING COLUMN WITH WRAP. UNLESS OTHERWISE NOTE' ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE ADJACENT COLUMN WRAP TYPICAL WALL ALIGNMENT PLAN TYPICAL DETAILS NOT ALL MAY APPLY 1 NO SCALE ANY EXISTING CONSTRUCTION (WALL, COLUMN WRAP, ETC) TO REMAIN. UNLESS OTHERWISE NOTED OR DIMENSIONED ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE OF ADJACENT EXISTING CONSTRUCTION TO REMAIN. NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. ANY EXISTING CONSTRUCTION (WALL, COLUMN WRAP, ETC) TO REMAIN. UNLESS OTHERWISE NOTED OR DIMENSIONED ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE OF ADJACENT EXISTING CONSTRUCTION TO REMAIN. NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. 1B NO SCALE NORTH PROPERTY MANAGER DATE DATE CARSON DESIGN ASSOCIATES DATE UPON EXECUTION, THE CLIENT AND PROPERTY MANAGER APPROVE ALL ASPECTS OF THE SCOPE OF WORK SHOWN IN THESE DOCUMENTS, INCLUDING DESIGN CONTENT, SCOPE OF CONSTRUCTION AND FINISH SELECTION FOR THE FOLLOWING PHASE: ❑ SPACE PLANNING ❑ PRELIMINARY PRICING CONSTRUCTION DOCUMENTATION 1:1 ALL COSTS INCURRED DUE TO MISINTERPRETATION OF THESE DOCUMENTS OR ANY CHANGES TO THE PROJECT REQUESTED AFTER SIGN -OFF SHALL NOT BE THE RESPONSIBILITY OF CARSON DESIGN ASSOCIATES AND SHALL BE THE SOLE RESPONSIBILITY OF THE CLIENT. TYPICAL WALL @ MULLION DETAIL NEW OR EXISTING WINDOW MULLION BLACK NEOPRENE SEAL ADHERED TO FACE OF MULLION AND SILL CAP AT ALL EXPOSED SURFACES ADJACENT TO ALUMINUM CHANNEL. ALUMINUM BRAKE METAL CHANNEL W/EDGES RETURNED (COLOR TO MATCH WINDOW FRAMING SYSTEM). EDGE OF SILL BELOW, WALL CONSTRUCTION (REF. TO FLOOR PLAN) CENTER ON WINDOW MULLION )E TIGHT FIT WHERE WALL IS COPED ff WINDOW SILL CONSTRUCTION. 1A CARSON DESIGN ASSOCIATES TEL 317.843.5979 `AX 317.843.5975 2325 POINTE PARKWAY SUITE 200 CAtnMEL INDIANA 46032 TEL S 12.977.0520 FAX :;12.977.0384 12301 ESEARCH BLVD. BUILDI G N, SUITE 104 AUSTIN -EXAS 78759 www.cam ickWgn.com THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP W N W m � C�fl CJS � � Z U Q z z Q = W Lo CV Q ,_ U DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: INDEX SHEET JOB NO. NO SCALE 0420608 10/14/2004 SHEET NUMBER: AO SHEET OF w E � W N y y cn „ 4 z �z 3�; < O 4 C N U nO U c zR' w ; = " - � r Q ii CT wy� oi C O O :> E i ,y ;; E o ° O C E A U C- o y E A a < c W Cy) w Q z 17 W U -5 3 U U' v � `° R L m> W aI E u U y c 75 v ti ;m O N 1•+ V G W N W m � C�fl CJS � � Z U Q z z Q = W Lo CV Q ,_ U DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: INDEX SHEET JOB NO. NO SCALE 0420608 10/14/2004 SHEET NUMBER: AO SHEET OF y y C � 7✓i N U nO N V a a =ti �v v o' oN 17 -5 3 U' `° R L m> z u 75 v ti ;m N 1•+ V G U ` E c c d m �C V i d fes, OJ y < (� v 8, Z oU ro �n N, plkill M U: W N W m � C�fl CJS � � Z U Q z z Q = W Lo CV Q ,_ U DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: INDEX SHEET JOB NO. NO SCALE 0420608 10/14/2004 SHEET NUMBER: AO SHEET OF CONSTRUCTION PHASING PLAN 1-AO.b 1/8' =114 NORTH CJS CARSON mwN ASSOCU4m TEL 317.843.5979 FAX 317.843.5975 2325 POINTE PARKWAY SUITE 200 CARMEL INDIANA 46032 TEL 512.977.0520 FAX 512.977.0384 12301 RESEARCH BLVD. BUILDING IV, SUITE 104 AUSTIN TEXAS 78759 www.cwsondeslgn c m THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP E3 Z DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING imE. CONSTRUCTION PHASING PLAN JOB NO. 0420608 10/14/2004 SHEET NUMBER: m F- N CC w w m CD Lu ry- Co Lu U Q U � F- z 1 = w Lu Q tV Q U U ,- CA E3 Z DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING imE. CONSTRUCTION PHASING PLAN JOB NO. 0420608 10/14/2004 SHEET NUMBER: NOTE: ALL CEILING INFO SHOWN IS TO BE REMOVED. REUSE LIGHTING FOR NEW CEILING LAYOUT. DEMOLITION CEILING PLAN DEMOLITION PLAN 2-A1 NTS NORTH 1-A1 1/8" =1'-0" NORTH DEMOLITION LEGEND REFER TO GENERAL DEMOLITION NOTES FOR ADDITIONAL INFORMATION. INDICATES EXISTING PARTITIONS TO BE REMOVED. SEE DEMO DRAWING. HIDDEN LINES INDICATE PORTION OF EXISTING PARTITION TO BE REMOVED FOR FUTURE CONSTRUCTION. SEE FLOOR PLAN FOR REQUIRED USAGE. INDICATES EXISTING DOOR AND FRAME TO BE REMOVED.(OR DOOR & SIDELIGHT IF INDICATED AS SUCH). NOTE: DOORS MAY BE RE -USED. COORDINATE WITH BUILDING OWNER POSSIBLE DOOR RE -USE. USE ONLY BEST CONDITION DOORS FOR THIS PURPOSE. REFER TO FLOOR PLANS FOR POSSIBLE NEW LOCATION. ----, INDICATES EXISTING LIGHT FIXTURE TO BE REMOVED. NOTE: FIXTURE MAY BE GENERAL DEMOLITION NOTES NOT ALL MAY APPLY. REFER TO DEMOLITION PLAN FOR ADDITIONAL NOTES AND DEMOLITION INFO. 1, DASHED LINES INDICATE EXISTING ITEMS TO BE REMOVED. UNLESS NOTED OTHERWISE CONTRACTOR SHALL BE ___ USE ONLY BEST CONDITION FIXTURES FOR THIS PURPOSE. FIXTURES MUST BE THOROUGHLY CLEANED AND INSPECTED PRIOR TO RE RESPONSIBLE FOR THE OFF-SITE DISPOSAL OF ALL DEMOLITION ITEMS. 2. RELOCATED ITEMS SHALL BE CLEANED AND PLACED IN STORAGE PER OWNER'S DIRECTIONS UNTIL ITEMS ARE READY }. -INSTALLATION. TO BE REINSTALLED. IF ITEM IS DAMAGED DURING DEMOLITION OR RELOCATION IT SHALL BE REPAIRED OR REPLACED WITH NEW ITEM AS APPROVED BY OWNER AT NO EXPENSE TO OWNER. 3. DEMOLITION SHALL BE DONE WITHOUT DAMAGE TO EXISTING CONSTRUCTION TO REMAIN. WHERE SUCH DAMAGE OCCURS PATCH, REPAIR, OR RESTORE WALLS, FLOORS, CEILINGS, ETC TO MATCH EXISTING. PROVIDE SHORING, BRACING, OR SUPPORT AS REQUIRED TO PREVENT MOVEMENT OR SETTLEMENT OF EXISTING CONSTRUCTION. CARSON 4. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF DEMOLITION ITEMS WITH THE OTHER TRADES PRIOR DESIGN INDICATES EXISTING 2X CEILING GRID TO BE REMOVED. TO THE START OF DEMO WORK. 5. REMOVE ALL EXISTING CONSTRUCTION, ITEMS AND FINISHES MADE OBSOLETE BY, OR IN CONFLICT WITH NEW ASS00A7IES CONSTRUCTION. VERIFY WITH ARCHITECT ANY ITEMS IN QUESTION. REMOVE WIRING BACK TO SOURCE AT ALL OUTLETS MADE OBSOLETE BY WALL REMOVAL OR ANY OTHER NEW CONSTRUCTION. TEL 317.843.5979 6. WHERE EXISTING WALLS, BULKHEADS, OR FINISHES ARE REMOVED OR PARTIALLY DEMOLISHED, EACH TRADE SHALL BE RESPONSIBLE FOR PATCHING OR REFINISHING OF EXISTING CONSTRUCTION REQUIRED BY THAT TRADE'S WORK ON FAX 317.843.5975 THIS PROJECT. THIS WORK MUST BE DONE IN A MANNER WHICH WILL ACCEPT NEW FINISHES. 2325 POINTE PARKWAY 7. ALL CONTRACTORS ARE RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILING GRID AND/OR TILES IN ANY AREA x WHERE ACCESS IS REQUIRED AND THE EXISTING CEILING IS TO REMAIN. UNLESS OTHERWISE NOTED, CONTRACTOR SUITE 200 SHALL REPLACE ANY CEILING TILES OR GRID DAMAGED IN THIS PROCESS. 8• AT THE OWNER'S REQUEST SALVAGED ITEMS SHALL BE TURNED OVER TO THE OWNER OR STORED IN AN AREA CARMEL INDIAPUI 46032 DESIGNATED BY THE OWNER. 9, ALL DIMENSIONS SHOWN FOR EXISTING CONSTRUCTION TO BE DEMOLISHED ARE APPROXIMATE AND ARE INTENDED TO TEL 512.977.0520 CV GIVE A GENERAL IDEA OF WORK TO BE REMOVED OR WORK TO BE TEMPORARILY REMOVED IN ORDER TO COMPLETE ■� NEW CONSTRUCTION. COORDINATE DEMOLITION WORK WITH DESIGN INTENT OF NEW CONSTRUCTION TO PROVIDE FAX 512.977.0384 Co ADEQUATE AREA FOR THIS WORK. 10. CONTRACTOR MUST FIELD VERIFY ALL AREAS AND/OR WORK TO BE DEMOLISHED PRIOR TO BEGINNING WORK. 12301 RESEARCH BLVD. C-0 CONTRACTOR MUST COORDINATE WITH ARCHITECT ANY DIFFERENCES BETWEEN FIELD VERIFIED CONDITIONS AND/OR � CONSTRUCTION, AND WHAT IS SHOWN ON DEMOLITION DRAWINGS. BUILDING IV, SUITE 104 11. PRIOR TO BEGINNING DEMOLITION, DUST CONTROL BARRIERS SHALL BE CONSTRUCTED TO PREVENT THE SPREAD OF AUSTIN TEXAS 78759 DUST INTO SURROUNDING AREAS. U 12. EXITING FROM STRUCTURE, IF REQUIRED TO PASS THROUGH DEMOLITION AREA(S), SHALL HAVE APPROVED BARRIERS www.cwsmdediprLcorn ETC, TO INSURE SAFETY OF PUBLIC. OU 13. WHEN APPLICABLE, REFER TO STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DEMO DRAWINGS FOR ADDITIONAL DEMOLITION REQUIREMENTS AND INFO. THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS 14. REMOVE AND REINSTALL ALL EQUIPMENT OR CONSTRUCTION ON WALLS REQUIRING NEW FINISHES. CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY DEMOLITION KEYNOTESLjLj OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED 15. REFINISH ENTIRE SURFACES AS NECESSARY TO PROVIDE AN EVEN FINISH. REFINISH ENTIRE ASSEMBLIES. CONTINUOUS OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN SURFACES WALL BE TAKEN TO THE NEAREST INTERSECTION. CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES 16. REMOVE ALL DIRT, DUST, AND DEBRIS DAILY. DO NOT ALLOW REFUSE TO BLOCK CORRIDORS, STAIRS, OR ANY OTHER TRAFFIC AREA. STAMP 17. IT IS ESSENTIAL THAT THE CLIENT BE ABLE TO FUNCTION AS NORMAL AS POSSIBLE IN AREAS ADJACENT TO RENOVATION OR NEW CONSTRUCTION. DEMOLITION LEGEND REFER TO GENERAL DEMOLITION NOTES FOR ADDITIONAL INFORMATION. INDICATES EXISTING PARTITIONS TO BE REMOVED. SEE DEMO DRAWING. HIDDEN LINES INDICATE PORTION OF EXISTING PARTITION TO BE REMOVED FOR FUTURE CONSTRUCTION. SEE FLOOR PLAN FOR REQUIRED USAGE. INDICATES EXISTING DOOR AND FRAME TO BE REMOVED.(OR DOOR & SIDELIGHT IF INDICATED AS SUCH). NOTE: DOORS MAY BE RE -USED. COORDINATE WITH BUILDING OWNER POSSIBLE DOOR RE -USE. USE ONLY BEST CONDITION DOORS FOR THIS PURPOSE. REFER TO FLOOR PLANS FOR POSSIBLE NEW LOCATION. ----, INDICATES EXISTING LIGHT FIXTURE TO BE REMOVED. NOTE: FIXTURE MAY BE RE -USED. REFER TO REFLECTED CEILING PLAN FOR POSSIBLE NEW LOCATION. ___ USE ONLY BEST CONDITION FIXTURES FOR THIS PURPOSE. FIXTURES MUST BE THOROUGHLY CLEANED AND INSPECTED PRIOR TO RE Z }. -INSTALLATION. O INDICATES EXISTING 2X CEILING GRID TO BE REMOVED. COD HATCHING INDICATES AREA NOT IN CONTRACT. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION.no x W Cy:) H CV ■� ry- W Co i W ~ cc C-0 � z � cf' U U Q U OU fm vUJI z DEMOLITION KEYNOTESLjLj J = W L Oj REMOVE EXISTING STAGE. � ¢ N U O REMOVE EXISTING RESTROOM PARTITIONS. t/� a V T 3O REMOVE EXISTING COUNTERTOP AND REPLACE WITH NEW. O4 REMOVE EXISTING TOILET AND SAVE FOR RE -USE. ca OREMOVE CABINETRY AND SAVE FOR REUSE, SEE CONSTRUCTION PLAN. (1) 43" BASE CABINET TO BE REUSED IN THE BREAKROOM AREA. THE OTHER (2) CABINETS TO BE REUSED IN THE CLASSROOM/137. OREMOVE (1) 33" BASE CABINET AND REUSE AT THE LARGE CLASSROOM/137. THE OTHER 33" BASE & 42" CABINETS TO BE REUSED IN THIS ROOM. THE WALL CABINETS TO BE REMOVED cc AND NOT REUSED. O 7 O REUSE EXISTING DOUBLE DOORS FOR NEW SANTUARY ENTRANCE. g O REMOVE EXISTING MILLWORK AND WORKSURFACE. gD EXISTING WINDOW TO BE RE -USED. SEE CONSTRUCTION PLAN. 10 RELOCATE EXISTING LADDER TO SOUTHSIDE OF PHONE ROOM. SEE CONSTRUCTION PLAN. 11 REMOVE AND RELOCATE EXISTING BOOKCASES AND COORDINATE NEW LOCATION WITH MORNING STAR. DATE / ISSUE / INITIALS: 12 EXISTING PHONE ROOM; ALL WIRING,ETC. TO BE REMOVED. 13 REMOVE PORTION OF EXTERIOR WINDOW FOR NEW ENTRY DOOR (DOUBLE DOOR ENTRY). 14 REMOVE PORTION OF EXTERIOR OF WALL AND OVERHEAD DOOR FOR NEW DOUBLE DOORS. 15 REMOVE EXISTING SHELVING. SQUARE FOOTAGE: DRAWING TITLE: JOB NO. 0420608 10/14/2004 SHEET NUMBER: I:�1 CONSTRUCTION PLAN 1-A2 1/8' =1'-0' NORTH cJ W ci W GENERAL FLOOR PLAN NOTES NOT ALL MAY APPLY. REFER TO PLANS FOR ADDITIONAL NOTES AND INFORMATION. 1. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS, JOB CONDITIONS, ETC. 2. ALL DIMENSIONS ON PLANS ARE TO FINISHED FACE OF MTL STUD WALL, CONCRETE MASONRY UNIT OR BRICK. 3. WHERE DISSIMILAR FLOOR MATERIALS MEET THEY SHALL DO SO UNDER THE CENTERLINE OF THE DOOR, UNLESS NOTED OTHERWISE, 4. PROVIDE DEEP LEG TRACKS AT ALL METAL STUD CONNECTIONS TO STRUCTURE ABOVE, UNLESS NOTED OTHERWISE. 5. HINGE SIDE OF DOOR JAMBS IN METAL STUD WALLS WILL TYPICALLY BE LOCATED 4" FROM ADJACENT WALL. UNLESS NOTED OTHERWISE. 6. PROVIDE METAL OR FIRE RETARDANT TREATED WOOD BLOCKING IN NEW METAL STUD WALLS AND EXISTING WALLS FOR ALL WALL SUPPORTED ITEMS. PATCH AND REPAIR WALL FINISH TO MATCH ADJACENT WALL SURFACE FOLLOWING INSTALLATION OF BLOCKING AS REQUIRED, 7. PROVIDE U.L. LISTED FIRE STOPPING AT PENETRATIONS OF ALL RATED WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR RATED WALL LOCATIONS. 8. SEE REFLECTED CEILING PLANS FOR BULKHEAD LOCATIONS AND ASSOCIATED DETAIL REFERENCES. 9. REFER TO DEMOLITION PLAN FOR ALL REQUIRED DEMOLITION WORK. 10. REFER TO ROOM FINISH SCHEDULE OR FINISH PLAN FOR ALL REQUIRED FINISH INFORMATION. 11. REFER TO DOOR SCHEDULE FOR ALL DOOR AND FRAME TYPES, HARDWARE INFORMATION AND ALL OTHER DOOR INFORMATION. 12. WHERE NEW WALL CONSTRUCTION IS SHOWN ABUTTING WINDOW MULLIONS, CENTER WALL CONSTRUCTION ON MULLION. REFER TO TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL CONSTRUCTION INFORMATION. 13. WHERE NEW WALL CONSTRUCTION IS REQUIRED ADJACENT TO OR ABUTTING EXISTING CONSTRUCTION, ALIGN FACE OF NEW CONST. WITH FACE OF EXISTING CONST. SEE TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL INFORMATION. 14. ALL FINISHES SHALL CONFORM TO CHAPTER 8 OF THE 2000 INTERNATIONAL BUILDING CODE AND THE 2003 INDIANA AMENDMENTS. 15. LEAVE 1'-6" OF UNOBSTRUCTED SPACE ON LATCH/PULL SIDE OF ALL DOORS AND 1'-0" OF UNOBSTRUCTED SPACE ON LATCH/PUSH SIDE OF DOORS FOR A.D.A. COMPLIANCE. 16. MATERIALS EXPOSED WITHIN PLENUM SPACES DESIGNED TO ALLOW AIR MOVEMENT AND FUNCTION AS PART OF THE AIR DISTRIBUTION SYSTEM ARE REQUIRED TO BE NONCOMBUSIBLE OR SHELL HAVE A FLAME SPREAD INDEX LESS THAN 25 AND A SMOKE DEVELOPED INDEX LESS THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84. ALL COMBUSTIBLE MATERIALS LOCATED WITHIN THESE PLENUM SPACES SHALL BE ENCLOSED IN NONCOMBUSTIBLE MATERIAL (5/8" GYPSUM BOARD) UNLESS OTHERWISE INDICATED. 17. UNLESS OTHERWISE NOTED, ALL INTERIOR WALLS SHALL BE TYPE #1. SEE WALL TYPES ON INDEX SHEET FOR ADDITIONAL INFO. 18. PROVIDE CONTROL JOINTS IN ALL RUNS OF METAL STUD/GYP BD WALLS OVER 30' IN LENGTH. COORDINATE LOCATIONS WITH CARSON DESIGN ASSOCIATES PRIOR TO INSTALLATION FOR COMPLIANCE WITH DESIGN INTENT. GENERAL KEYNOTES O CENTER NEW WALL CONSTRUCTION WITH WINDOW MULLION. SEE DETAIL 1A -A0. OALIGN NEW WALL CONSTRUCTION WITH COLUMN ENCLOSURE. SEE DETAIL 1B -AO. O NEW FOLDING ACCORDIAN DOOR TO BE INSTALLED. MFR: HUFCOR O4 24"DP. PLASTIC LAMINATE COUNTERTOP, SEE DETAIL 4/A8 FOR INFO. ONEW SIDELIGHT WITH TEMPERED GLASS, TO BE INSTALLED (7' HIGH). REFER TO DOOR SCHEDULE FOR INFO. O INSTALL RELOCATED PHONE ROOM LADDER TO THIS LOCATION. O NEW PLATFORM (33"+/-) TO BE BUILT (WOOD STUD CONSTRUCTION). G.C. TO COORDINATE EXACT CONSTRUCTION REQUIREMENTS WITH TENANT. (11" MIN. TREADS, 7" MAX. RISERS) O NEW 1/4" COPPER WATERLINE TO BE INSTALLED FOR TENANTS REFRIGERATOR/ICEMAKER. 5'-6" ENLARGED RESTROOM PLAN 2-A2 1/4' =1'-0' NOTE: SEE RESTROOM EQUIPMENT, FlXTURE CLEARANCES AND INSTALLATION HEIGHTS ON 5-A8. CEMENT BOARD FOR CONSTRUCTION AT TOILET ROOMS. ENLARGED RESTROOM KEYNOTES NOTE; DIMENSIONS ARE FROM FINISH FACE OF WALL TO CENTERLINE OF FIXTURE. UON. A SURFACE MOUNTED MULTI—ROLL TOILET TISSUE DISPENSER. MOUNT ® 28" AFF TO TOP. MOUNT HORIZONTALLY AT 36' FROM FACE OF BACK WALL TO FRONT EDGE OF PAPER ROLL. BOBRICK B-2888 'CLASSIC SERIES' OR EQUAL. OB NEW WALL MOUNTED URINAL TO BE INSTALLED. MFR: AMERICAN STANDARD, STYLE: LYNBROOK 1.0 (OR EQUAL). CO ADA COMPLIANT, FLOOR MOUNTED WATER CLOSET. DO EXISTING MIRROR TO REMAIN. OE 1 1/2" DIA S.S. GRAB BARS WITH SNAP FLANGES. BOBRICK B-68137. MOUNT SO CENTERLINE IS AT 36" AFF. (OR EQUAL) OF NEW SANITARY NAPKIN DISPOSAL TO BE INSTALLED. MFR: BOBRICK, STYLE: CLASSIC SERIES, B-354 (OR EQUAL). OG NEW TOILET/URINAL PARTITIONS TO BE INSTALLED. MFR: BOBRICK (OR EQUAL), STYLE: STANDARD SOLID PHENOLIC, COLOR: S-445 ALMOND CARSON DESIGN ASSOCIATES TEL 317.843.5979 FAX 317.843.5975 2325 POINTE PARKWAY SURE 200 CARMEL INDIANA 46032 TEL 511977.0520 FAX 511977.0384 12301 RESEARCH BLVD. BUILDING N, SUITE 104 AUSTIN TEXAS 78759 www.carsondes mcom THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP w O coow 4c no :04W M W N CC W M LLJ F- � C.0d' L -i C/) Q U V Q U ® COD F- Q z w = w !� Q N Q v T- v CID m Z O DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: CONSTRUCTION PLAN JOB NO. 0420608 10/1412004 SHEET NUMBER: r:r' PAINT EXISTING CEILING TO BE PAINTED BLACK NOTE: ALL 2'X 4' FLUORESCENT LIGHT FIXTURES TO RECEIVE ACRYLIC LENSES, REFLECTED CEILING PLAN 1-A3 NORTH REFLECTED CEILING PLAN GENERAL NOTES NOT ALL MAY APPLY, REFER TO REFL. CEILING PLAN FOR ADDITIONAL NOTES AND CEILING INFORMATION. 1. REFER TO INDEX SHEET FOR TYPICAL WALL TYPES (WALLS TO DECK, RATED WALLS, ETC) AND ADDITIONAL WALL -TO -CEILING DESIGN CONDITIONS AND CONSIDERATIONS. , 2. PROVIDE NIGHT LIGHT CIRCUITS AS REQUIRED. 3. REFER TO ROOM FINISH SCHEDULE FOR SPECIFIC CEILING TYPES, MATERIALS, ETC. -momwp- 4. THE ARCHITECTURAL REFLECTED CEILING PLANS SHALL GOVERN THE LAYOUT OF ALL CEILING ELEMENTS 3 PLATE COLOR TO MATCH EXISTING EXISTING TO REMAIN (U.O.N.) $ AND/OR PENETRATIONS. COORDINATE WITH ARCHITECT ANY FIELD VERIFIED OR AS -BUILT CONDITIONS CARSON THAT DIFFER FROM WHAT IS SHOWN ON THESE PLANS. 5. SIZES OF MECHANICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE DEMN ACTUAL SIZES WITH MECHANICAL ENGINEER.ASSOCIA FLUORESCENT LIGHT FIXTURE SWITCH.) TES 6. SIZES AND SHAPES OF LIGHTING AND OTHER MISC ELECTRICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN NEW FIXTURE (U.O.N.) FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH ELECTRICAL ENGINEER. TEL 317.843.5979 7. UNLESS OTHERWISE NOTED, INSTALL SUSPENDED CEILING GRID WITH EQUAL SIZE PANELS AT EACH SIDE FAX 317.843.5975 OR ENDS OF ROOMS. NO PANELS SHOULD BE LESS THAN 1'-O" WIDE. FLUORESCENT LIGHT FIXTURE SOLID DENOTES DIRECTION OF FACEPLATE. 8. IF POSSIBLE ANY CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING MECHANISMS, ETC) SHOULD BE 2325 PO KITE PARKWAY CENTERED IN CEILING PANELS. SUITE 200 9. WHERE EXISTING CEILING GRID IS REMODELED TO MEET NEW CONSTRUCTION THE CONTRACTOR SHALL: BUILDING STANDARD 2X2 4& EMERGENCY LIGHT FIXTURE W/ EMERGENCY A. REPLACE ALL DAMAGED OR UNREPAIRABLE PORTIONS OF EXISTING GRID WITH NEW GRID TO CARMEL INDIANA 46032 MATCH EXISTING BUILDING STANDARDS. B. REMOVE PORTIONS OF EXISTING GRID OR PROVIDE NEW GRID AS REQUIRED BY NEW CONSTRUCTION. TEL 512.977.0520 ALL NEW GRID MUST MATCH EXISTING TO REMAIN. FAX 512.977.0384 C. REPLACE ALL DAMAGED CEILING TILES WITH NEW TILES TO MATCH EXISTING TO REMAIN OR TO MATCH EXISTING BUILDING STANDARDS. 12301 RESEARCH BLVD. BUILDING IV, SURE 104 FLUORESCENT LIGHT FIXTURE AUSTIN TEXAS 78759 THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP REFLECTED CEILING LEGEND BUILDING STANDARD 2X4 $ WALL MOUNTED LIGHT SWITCH. COVER FLUORESCENT LIGHT FIXTURE 3 PLATE COLOR TO MATCH EXISTING EXISTING TO REMAIN (U.O.N.) $ ADJACENT COVER PLATES. ("3" DENOTES o N BUILDING STANDARD 2X4 $� 3 -WAY SWITCH.) ("D" DENOTES DIMMER FLUORESCENT LIGHT FIXTURE SWITCH.) NEW FIXTURE (U.O.N.) o R BUILDING STANDARD 2X4 BUILDING STANDARD ILLUMINATED EXIT LIGHT FLUORESCENT LIGHT FIXTURE SOLID DENOTES DIRECTION OF FACEPLATE. TO BE RELOCATED. BUILDING STANDARD 2X2 4& EMERGENCY LIGHT FIXTURE W/ EMERGENCY FLUORESCENT LIGHT FIXTURE EXIT LIGHTING PACK & BATTERY BACK UP. SEE TYP 2X4 NOTES ABOVE. NL BUILDING STANDARD 2X4 C PAINTED GYP. BOARD BULKHEAD FLUORESCENT LIGHT FIXTURE ON NIGHT LIGHT CIRCUIT (U.O.N.) RELOCATED INDUSTRIAL LIGHT FIXTURE TO EXISTING CEILING GRID TO REMAIN. BE INSTALLED (OLD SANCTUARY). CA INDICATES NEW CEILING GRID TO BE INSTALLED. NEW INCANDESCENT DOWNLIGHT (DIMMABLE) K2 MFR: PORTFOLIO, MODEL: H8600, LAMP: 15OW A21 (COLOR -BLACK) ON SUSPENDED CYLINDER. UNLESS NOTED WITH AN "N" OR AN "R" ALL co N REP: SPECIFIED LIGHTING CONTACT MELINDA ITEMS SHOWN WILL BE EXISTING TO REMAIN. (317)577-8100 CC W MDYKSTRA O vI.— UJI w c16— Lu Q REFER TO ROOM FINISH SCHEDULE FOR SPECIFIC CEILING TYPES AND HEIGHTS. U `� z U Q REFER TO FLOOR PLANS FOR SPECIFIC WALL CONSTRUCTION. = O C-5 Q C-) z ~ NOTE: HVAC CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE HEATING, COOLING AND HUMIDITY CONTROL (AS APPLICABLE) IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY —1 = L EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. REFER TO MECHANICAL DRAWINGS FOR ALL LOCATIONS OF HVAC EQUIPMENT, EITHER SHOWN HERE CwC CC OR NOT SHOWN HERE, AND COORDINATE WITH G G ARCHITECT OR ARCHITECT'S FIELD REPRESENTATIVE ANY CONFLICTS DISCOVERED BETWEEN ARCHITECT'S (\ AND MECHANICAL ENGINEER'S DRAWINGS.1 � U N Q r v NOTE: SPRINKLER CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE SPRINKLER LAYOUT IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. LAYOUT MUST MEET ALL APPLICABLE LOCAL AND STATE CODES. REFER TO SPRINKLER DRAWINGS FOR ALL LOCATIONS OF THAT EQUIPMENT, EITHER SHOWN OR NOT SHOWN HERE, AND cm COORDINATE WITH ARCHITECT OR ARCHITECT'S FIELD REPRESENTATIVE, AND MECHANICAL ENGINEER ANY CONFLICTS DISCOVERED BETWEEN SPRINKLER CONTRACTOR'S DRAWINGS AND ARCHITECT'S OR MECHANICAL ENGINEER'S DRAWINGS. NOTE; ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR THE REWIRING AND/OR RE-SWfTCHING OF ALL LIGHT FIXTURES AND/OR LIGHT SWITCHES AS REQUIRED BY NEW CONSTRUCTION. COORDINATE WITH ARCHITECT ANY ADDITIONAL REQUIRED WORK NOT SHOWN HERE. ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER OTHER TRADES' DRAWINGS WHEN CONFLICTS ARISE. BRING CONFLICTS OR INCONSISTENCIES BETWEEN ARCHITECTURAL DRAWINGS AND DRAWINGS OF OTHER DISCIPLINES O TO THE ATTENTION OF THE ARCHITECT. O O O O GENERAL KEYNOTES EXISTING LIGHTING TO REMAIN. COORDINATE WITH TENANT FOR ANY CHANGES. NEW PAINTED GYP. BOARD BULKHEAD, BOTTOM OF BULKHEAD AT 8'-0". NEW PAINTED GYP. BOARD ARCHED BULKHEAD, BOTTOM OF BULKHEAD AT 8'-0". NEW CEILING GRID AND TILE, CENTER GRID WITHIN ROOM AS SHOWN. CEILING HEIGHT TO BE AT 11'-0" A.F.F. DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: REFLECTED CEILING PLAN 0420608 10/14/2004 SHEET NUMBER: A3 SHEET OF ELECTRICAL PLAN 1-A4 1/8" =1'-0" NORTH GENERAL ELECTRICAL NOTES NOT ALL MAY APPLY. REFER TO ELECTRICAL PLAN FOR ADDITIONAL NOTES AND ELECTRICAL INFO. 1. THIS DRAWING IS INTENDED TO PROVIDE INFORMATION RELATING TO THE LOCATION OF WIRING DEVICES AND OUTLETS ONLY. IT IS THE RESPONSIBILITY OF THE ELECTRICAL DESIGN/BUILD CONTRACTOR TO PROVIDE NECESSARY DOCUMENTS RELATING TO THE ACTUAL ELECTRICAL INSTALLATION AND TO INSTALL ALL WIRING DEVICES IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES. 2. ALL DIMENSIONS ARE FROM FINISHED WALL SURFACE OR COLUMN CENTERLINE TO CENTERLINE OF OUTLETS OR CENTERLINE OF PAIRS OF OUTLETS. 3. ALL WALL MOUNTED WIRING DEVICES AND RECEPTACLES SHOWN BACK TO BACK SHALL BE OFFSET A MINIMUM OF 8" AND ACOUSTICALLY SEALED. 4. WHERE DIRECT CONNECTION TO PREWIRED FURNITURE PANELS OCCURS, PROVIDE POWER AND TELECOMMUNICATION FEEDS TO INDICATED PANEL LOCATION FROM WALL, COLUMN OR FLOOR SOURCE DIRECTLY ADJACENT TO THIS LOCATION. 5. ALL EXISTING FLOOR MOUNTED ELECTRICAL/TELECOMMUNICATION DEVICES WHICH ARE NOT REUSED ARE TO BE REMOVED. REMOVE ALL ASSOCIATED CABLE, WIRE AND CONDUIT BACK TO SOURCE. PROPERLY PATCH AND REPAIR AFFECTED FLOOR AREA. 6. UNLESS OTHERWISE NOTED ALL DEVICE ELEVATIONS INDICATED ON ELECTRICAL PLAN REFER TO BOTTOM OF OUTLET. 7. REFER TO REFLECTED CEILING PLANS FOR LOCATIONS OF LIGHT SWITCHES. 8. USE GROUND FAULT INTERUPT (G.F.I.) OUTLETS IN THE VICINITY OF ANY WET AREAS (KITCHENS, BREAK ROOMS, RESTROOMS, JANITORIAL ROOMS WITH FLOOR SINKS, LAUNDRY ROOMS, STAND ALONE WALL MOUNTED SINKS, ELECTRIC WATER FOUNTAINS, ETC.). SEE ELECTRICAL LEGEND. OO 220 ELECTRICAL LEGEND REFER TO ELECTRICAL PLAN FOR ADDITIONAL NOTES AND ELECTRICAL INFO. BUILDING STANDARD ELECTRICAL INDICATES NEW ITEM LOCATION JUNCTION BOX. N AS SHOWN. SEE NOTE BELOW. BUILDING STANDARD WALL MOUNTED DUPLEX OUTLET. 220 OUTLET BUILDING STANDARD WALL MOUNTED FOUR-PLEX ELECTRICAL OUTLET. BUILDING STANDARD WALL MOUNTED DEDICATED DUPLEX OUTLET. BUILDING STANDARD WALL MOUNTED DATA LINE OUTLET BUILDING STANDARD WALL MOUNTED TELEPHONE OUTLET WALL MOUNTED TELEPHONE AND DATA LINE SHARED OUTLET. GFI INDICATES GROUND FAULT INTERRUPT OUTLET. +42" SPECIAL MOUNTING HEIGHT INDICATION FOR WALL OUTLETS. TAKEN TO BOTTOM OF PLATE. NOTE: UNLESS NOTED WITH AN "R" OR AN "N", ALL ITEMS WILL BE EXISTING TO REMAIN. CARSON DESIGN ASSOCIATES TEL 317.843.5979 FAX 317.843.5975 2325 P01NTE PARKWAY SUITE 200 CARMEL INDIANA 46032 TEL S11977.0520 FAX S 12977.0384 12301 RESEARCH BLVD, BUILDING IV, SUITE 104 AUSTIN TEXAS 78759 www.cusoixksign.com THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: ELECTRICAL PLAN JOB NO. 0420608 10/14/2004 SHEET NUMBER: O ca 0 W m F- CV rr- W W M W ry W C/) Q U CU Q C-5 O C.D z J =W W C !� Q CV Q COD DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: ELECTRICAL PLAN JOB NO. 0420608 10/14/2004 SHEET NUMBER: FINISH PLAN 1-A5 1/8" =1'-0" ROOM FINISH LEGEND CODE TMATERIAL MANUFACTURER NUMBER / COLOR NORTH REMARKS CPT1 CARPET MASLAND RHYTHM 7816 18602 MEASURE T1 FLOOR TILE AMERICAN OLEAN EARTHSCAPES RAIN FORREST ES03 SEE ENLARGED PLAN FOR SIZES P1 PAINT TO MATCH EX I S T I N G M-1 I METAL CPN/CHURCH PLAZA METALLIC IMPALA M-6 F-1 FABRIC ABSECON FANDANGO SWEET PEA R09 VCT1 VINYL COMPOSITION TILE T O M A T C H E X I S T I N G B1 VINYL BASE TO MATCH EXISTING 62 TILE BASE AMERICAN OLEAN EARTHSCAPES S43C9 3" X 12" MATCH TRIM BASE PL1 PLASTIC LAMINATE TO BE DETERMINED CAB1 CABINETRY MERILLAT SUNDALE TOFFEE MAPLE WD1 WOOD FLOORING BY TENANT. GENERAL FINISH PLAN NOTES GENERAL 1. ALL DIMENSIONS ARE TAKEN TO FINISHED FACE OF WALL OR TO THE FACE OF THE EXISTING FINISH MATERIAL, UNLESS OTHERWISE NOTED. 2. VERIFY ALL CRITICAL DIMENSIONS WITHIN AND/OR RELATED TO THE EXISTING BUILDING. DIMENSIONS AND CONDITIONS INDICATED WERE DETERMINED BY VISUAL SURVEY AND/OR INFORMATION FROM EXISTING DRAWINGS. 3, +— DIMENSION IS EQUAL TO VERIFY IN FIELD. 4. REFER TO ROOM FINISH SCHEDULE AND LEGEND FOR ALL REQUIRED FINISH INFORMATION. 5. ALL EXISTING WALLS, FLOORS, AND CEILINGS SHALL BE FINISHED/REPAIRED SMOOTH TO BE SUITABLE TO RECEIVE NEW FINISHES AS DESCRIBED ON ROOM SCHEDULE/LEGEND. 6. E.T.R. MEANS EXISTING TO REMAIN. 7. N.I.C. MEANS NOT IN CONTRACT. 8. RALL EXISTING ECOMMENDED ND NEWTSURFACES TO BE PREPARED FOR FINISHES PER MANUFACTURERS 9.CONTRA OR CTOTO ORTO SUBMIT MATER APSES IN TRIPLICATE OF ALL FINISH MATERIALS TO CDA FOR APPROVAL 10. PLANS ARE NOT TO BE SCALED FOR FINISH INFORMATION. CONTRACTOR TO CONTACT CDA FOR ANY QUESTIONS OR CLARIFICATIONS ON PLAN DIMENSIONS. 12. ALL EXISTING EQUIPMENT OR FURNITURE SHOWN DASHED OR LIGHTER AND NOT IDENTIFIED ARE NOT PART OF THIS WORK AND ARE TO BE OWNER FURNISHED AND OWNER INSTALLED. FLOORING 14. WHERE S DISSIMILAR FLO RING MATERIALS MEET THEY SHALL DO SO UNDER CENTERLINE OF DOOR, 16. GROUT TO BE USED ON CT—__ IS LATICRETE IN COLOR 17, GROUT JOINTS ON FLOOR TILE TO BE 1/8" WIDTH, UNLESS OTHERWISE NOTED. GROUT JOINTS ON WALL TILE TO BE 1/8" WIDTH UNLESS OTHERWISE NOTED. IF MANUFACTURERS RECOMMENDED INSTALLATION INSTRUCTIONS DIFFER FROM THIS CONTRACTOR TO NOTIFY DESIGNER OF CONDITION. 18. FLOORING CONTRACTOR TO SUBMIT FLOOR SEAMING DIAGRAM TO CDA FOR REVIEW AND APPROVAL. PAINTINGI STAINING 19. ALL METAL DOORS TO BE PAINTED P-1 IN SEMI—GLOSS FINISH. 22. ALL WOOD DOORS TO BE STAINED TO MATCH EXISTING. 23. ALL WOOD DOORS TO BE PREFABRICATED/ FINISHED, TO MATCH EXISTING MORNING STAR CEIUNGS/WALLS 24. ALL VERTICAL FACES OF BULKHEADS TO MATCH ADJACENT WALL FINISH, UNLESS OTHERWISE NOTED. 25. ALL UNDER SIDE OF BULKHEADS TO BE PAINTED STANDARD CEILING WHITE, UNLESS OTHERWISE NOTED. 26. DRYWALL CEILINGS TO BE PAINTED STANDARD CEILING WHITE, UNLESS OTHERWISE NOTED. 27. EXISTING TYPICAL CEILING HEIGHT IS 8'-6". CONTRACTOR SHOULD VERIFY ALL CRITICAL DIMENSIONS WHEN DETERMINING WALL FINISH REQUIREMENTS. ENLARGED FLOOR PATTERN 6"x 6" 2-A5 1/2" =1'-0" CARSON DESIGN ASSOCIATES TEL 317.843.5979 FAX 317.843.5975 2325 POINTE PARKWAY SUITE 200 CARMEL INDIANA 46032 TEL 511977.0520 FAX 512.977.0384 12301 RESEARCH BLVD. BUILDING N, SUITE 104 AUSTIN TEXAS 78759 THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP CA a Q W wm Q H CA ca m I- CV CC Lu w m Lu I- cc C-0 L LJ U) Q U � z = O a z z Lu F_ Lu w :_5; L �C N Q DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: FINISH PLAN JOB NO. 0420608 10/14/2004 SHEET NUMBER: A5 SHEET OF CARSON DESIGN ASSOCIATES TEL 317.843.5979 FAX 317.843.5975 2325 POINTE PARKWAY SUITE 200 CARMEL INDIANA 46032 TEL 511977.0520 FAX 511977.0384 12301 RESEARCH BLVD. BUILDING IV, SUITE 104 AUSTIN TEXAS 78759 www.cwsondesi8n.00m THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: DETAILS, ELEVATIONS & DOOR SCHEDULE JOB NO. 0420608 10/14/2004 SHEET NUMBER: SHEET OF 0 ca w 14 a �1114W CY3 F- CV ■�■ i cr w w CY3 � w � z Lu cn U Y U Q _ CzLu 4 v F_cc Q z Lu = _; w 75 75 oc ry� Lo DIIIIIIIIII Q N Q C -D CO2 DATE / ISSUE / INITIALS: SQUARE FOOTAGE: DRAWING TITLE: DETAILS, ELEVATIONS & DOOR SCHEDULE JOB NO. 0420608 10/14/2004 SHEET NUMBER: SHEET OF