Loading...
HomeMy WebLinkAbout04100011 Building PlansAEN ons robvi DEMOLITION PLAN LEGEND _----- EXISTING WALL TO REMAIN. EXISTING DOOR & FRAME TO REMAIN EXISTING WALL TO BE DEMOLISHED. / EXISTING DOOR AND FRAME TO BE _ DEMOLISHED DEMOLITION PLAN KEYNOTES NONE SECOND FLOOR LAN - DEMOLITION 0' 4' 8' 16' 24' SCALE: 1 /8" = 1 ' -0" dlHSNMO.t JlbIj VINVIO31 S3 CJ�� S NIVO JO A A3 AllN!?mrgoo d0 .Ld3C1 s=10 nfa Poo 1�l pL1 " sigiS 10 I a IIij 4111 aoueIldwoo of loatgn N011OrldiSN00 80.1 Q s'vajau, DEMOLITION PLAN GENERAL NOTES D1. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES. LIGHT -WEIGHT, SOLID LINES INDICATED EXISTING CONSTRUCTION TO REMAIN. SALVAGE REUSABLE ITEMS. NOTE THAT MANY ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION. D2. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. D3. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED. SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION. D4. DO NOT REMOVE EXISTING CEILING GRID AND TILE. REPAIR OR REPLACE EXISTING GRID AND TILES AS REQUIRED AT AREAS OF DEMOLITION AND FOR NEW CONSTRUCTION. D5. BE CAREFUL ABOUT DEMOLITION; EXISTING CEILING, H.V.A.C., FIRE PROTECTION, AND ELECTRICAL ITEMS CAN BE RE -USED IF IN GOOD CONDITION. D6. REMOVE AND SALVAGE ELECTRICAL LIGHTING FIXTURES AS REQUIRED FOR NEW CONSTRUCTION. REUSE EXISTING ELECTRICAL LIGHTING FIXTURES IF POSSIBLE. D7. REMOVE ALL ABANDONED DATA CABLE ABOVE CEILING AND IN WALLS AS APPLICABLE. CONSULT WITH LANDLORD ON EXTENT OF WORK. NO SCALE SECOND FLOOR MERIDIAN TOWER 201 W. 103RD ST. CARMEL, IN N AREA LOCATION MAP -INDIANAPOLIS, IN.- 01% IAN DRAWING SCHEDULE t ry t a, D111 PLAN - DEMOLITION A111 PLAN - ARCHITECTURAL FLOOR A121 PLAN - ARCHITECTURAL FINISHES A131 PLAN - REFLECTED CEILING, FIRE -PROTECTION, 9 _'Pete Dial.PIS s 31 HVAC, ELECTRICAL LIGHTING A211 SCHEDULE - DOOR, ARCHITECTURAL DETAILS E111 PLAN - ELECTRICAL POWER t...-.-l�'"., 5prin-9 Hollow E9 rtil W 93rd St W92nd St NO SCALE SECOND FLOOR MERIDIAN TOWER 201 W. 103RD ST. CARMEL, IN N AREA LOCATION MAP -INDIANAPOLIS, IN.- 01% IAN uLa co 3 M �?-L�2 �- I, 11 i th Sr t ry t a, 14 ?Q i i x Env _..: ix '64C Hod tt1 _ —J _ 1 i f '-- 9'% { s Qi4 /., q LLX V r 71: E 145 LFA. TM: On 4'� 9 _'Pete Dial.PIS s 31 9Gth:S13� Hamilton E i-€ title a regi' 9btt St , .4 t...-.-l�'"., 5prin-9 Hollow E9 rtil W 93rd St W92nd St * • . 'w 91st St i E 9 1St -. In,; 4 NAYTE0... NO SCALE SECOND FLOOR MERIDIAN TOWER 201 W. 103RD ST. CARMEL, IN N SGV IJIVI IJ. G%ST ''. =" 910039 STATE OF IL D3.0 x 0000 Illilll Issue: STATE SUBMITTAL ISSUE Date: 09.10.2004 Sheet: D 111 A w W O SGV IJIVI IJ. G%ST ''. =" 910039 STATE OF IL D3.0 x 0000 Illilll Issue: STATE SUBMITTAL ISSUE Date: 09.10.2004 Sheet: D 111 A Sia r TM: Sia CEILING SOUND INSULAT' BASE AS SCHEDUI 35/8" METAL STUDS AT 16" O.C. ONE LAYER OF %" TYPE "X" GYPSUM BOARD EACH SIDE. EXTEND WALL TO DECK. FIBERGLASS BATT SOUND INSULATION INSIDE WALL. MATCH EXISTING STUD THICKNESS AT DOOR INFILLS. WALL TYPE "1P3" was ago CEILING SOUND INSULAT BASE AS SCHEDUI 35/8" METAL STUDS AT 16" O.C. ONE LAYER OF 5/8" TYPE "X" GYPSUM BOARD EACH SIDE. ARCHITECTURAL EXTEND WALL TO UNDERSIDE OF CEILING. FIBERGLASS BATT SOUND INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL MATCH EXISTING STUD THICKNESS AT DOOR INFILLS. EXISTING WALLS. WALL TYPE "W2" m SCALE: 3/8" = 1'-0" CEILING BASE AS SCHEDUI 35/8" METAL STUDS AT 16" O.C. ONE LAYER OF 5/8" TYPE "X" GYPSUM BOARD EACH SIDE. EXTEND WALL TO UNDERSIDE OF CEILING. MATCH EXISTING STUD THICKNESS AT DOOR INFILLS. WALL TYPE "W1" NOTE: ALL NEW WALLS ARE WALL TYPE: W, UNLESS NOTED OTHERWISE ALL PLAN DIMENSIONS ARE FROM, FACE OF EXISTING FINISH TO FACE OF NEW STUD OR FACE TO FACE OF NEW STUD UNLESS OTHERWISE NOTED. f SECOND FLOOR — ARCHITECTURAL 0' 4' 8' 16' 24' SCALE: 1/8" = 1'-0" ARCHITECTURAL GENERAL NOTES Al. PROVIDE FIRE—TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALLSTOPS, CABINETRY, ETC. A2. CONTRACTOR IS TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. A3. FIELD CHECK ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF JOB CONDIT1014S PREVENT OBTAINING DIMENSIONS OR RESULTS AS SHOWN OR SPECIFIED. A4. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY TO THE GENERAL CONTRACTOR WHO, IN TURN, MUST REPORT THE DISCREPANCY TO SCHOTT DESIGN, INC. A5. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. A6. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR FOR CHECKING, ORDERING, FABRICATION, OR DELIVERY OF MATERIALS AND EQUIPMENT. A7. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. A8. ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC. AND FINAL APPROVAL BY THE OWNER. A9. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE—BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. WALL LEGEND NEW WALL EXISTING WALL (SEE WALL TYPES TO REMAIN. yy, ON THIS SHEET) DOOR LEGEND DOOR AND FRAME ® WITHIN SCOPE OF DOOR AND FRAME 77OUTSIDE SCOPE OF ARCHITECTURAL WORK. PLAN KEYNOTES IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. ALIGN FINISHED WALL SURFACES. PROVIDE SAME Ao1 THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. ALIGN NEW WALL WITH CENTERLINE OF EXTERIOR A02 WINDOW MULLION. REFER TO REFERENCED DETAIL TTO V1 1/A211. A03 REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURED A7 REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. ALL CONDITIONS MAY NOT BE SHOWN ON DRAWING. DEMISING WALL TO BE BUILT WITH ADJACENT A04 TENANT NEW BUILD OUT. ALL PLAN DIMENSIONS ARE FROM, FACE OF EXISTING FINISH TO FACE OF NEW STUD OR FACE TO FACE OF NEW STUD UNLESS OTHERWISE NOTED. f SECOND FLOOR — ARCHITECTURAL 0' 4' 8' 16' 24' SCALE: 1/8" = 1'-0" ARCHITECTURAL GENERAL NOTES Al. PROVIDE FIRE—TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALLSTOPS, CABINETRY, ETC. A2. CONTRACTOR IS TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. A3. FIELD CHECK ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF JOB CONDIT1014S PREVENT OBTAINING DIMENSIONS OR RESULTS AS SHOWN OR SPECIFIED. A4. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY TO THE GENERAL CONTRACTOR WHO, IN TURN, MUST REPORT THE DISCREPANCY TO SCHOTT DESIGN, INC. A5. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. A6. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR FOR CHECKING, ORDERING, FABRICATION, OR DELIVERY OF MATERIALS AND EQUIPMENT. A7. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. A8. ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC. AND FINAL APPROVAL BY THE OWNER. A9. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE—BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. WALL LEGEND NEW WALL EXISTING WALL (SEE WALL TYPES TO REMAIN. yy, ON THIS SHEET) DOOR LEGEND DOOR AND FRAME ® WITHIN SCOPE OF DOOR AND FRAME 77OUTSIDE SCOPE OF WORK (SEE DOOR WORK. SCHEDULE). IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. KEY P NO SCALE SECOND FLOOR MERIDIAN TOWER 201 W. 103RD ST. CARMEL, IN N • w M d p U N d-�^ �ar00 z�00 en Q c7 M 0F5� zz�T cn CO Ln QJ =a • G CO Z x Now¢ n rnZ�w 0 0 TTO V1 Q P-11 ~ ; � po $4z H F, rAa cq Revisions: a H w H x x No. " 910039 5 STATE C F Issue: STATE SUBMITTAL ISSUE Date: 09.10.2004 Sheet A111 r I a I :E 7 ARCH. FINISHES LEGEND FLOOR COVERINGS LEGEND CARPET CPT1 MFG.: J & J INDUSTRIES F01 PATTERN: INTUITION 4160 MFG.: PITTSBURGH COLOR: GUT REACTION #8500 TYPE: LATEX APPLICATION: GLUE -DIRECT COLOR: ANTIQUE WHITE #516-2 SDI BUILDING STANDARD PROGRAM: FINISH: EGGSHELL $13.50 INSTALLED. MFG.: PITTSBURGH : FOR DOOR FRAMES VINYL COMPOSITE TILE (NOT USED). vCT1 MFG.: MANNINGTON COMMERICAL COLOR: CUSTOM COLOR TO MATCH SIZE: 12"02" EXISTING FRAMES IN SUITE PATTERN: ESSENTIALS FINISH: SEMI -GLOSS COLOR: SAND DRIFT #137 WALL BASE MFG.: RJF INTERNATIONAL, KOROSEAL/VICRTEX Sgt MFG.: JOHNSONITE TYPE: VINYL COVE, Y8" GUAGE PLASTIC SIZE: 4" PLt COLOR: #121 CEMENT F02 ARCH., FINISHES GENERAL NOTES FG1. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. FG2. ALL NEW PLATES AND SWITCHES ARE TO BE BUILDING STD. COLOR TO MATCH EXISTING. REMOVE ALL PLATES BEFORE PAINTING AND REATTACH AFTERWARDS. FG3. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. FG4. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS TO MATCH VINYL BASE COLOR. (WHERE VCT MEETS CARPET) FG5. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. FG6. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURED. ARCH. FINISHES ARCH. LEGEND 1KEY PAINT F01 PT1 MFG.: PITTSBURGH F02 TYPE: LATEX COLOR: ANTIQUE WHITE #516-2 FINISH: EGGSHELL PT2 MFG.: PITTSBURGH : FOR DOOR FRAMES TYPE: LATEX COLOR: CUSTOM COLOR TO MATCH EXISTING FRAMES IN SUITE FINISH: SEMI -GLOSS VINYL WALLCOVERING WC1 MFG.: RJF INTERNATIONAL, KOROSEAL/VICRTEX TYPE: BUILDING STANDARD, TYPE I COLOR: TITIAN #T815-20 PLASTIC LAMINATE (NOT USED) . PLt MFG: WILSONART COLOR: BRONZE LEGACY #4656-60 ARCH., FINISHES GENERAL NOTES FG1. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. FG2. ALL NEW PLATES AND SWITCHES ARE TO BE BUILDING STD. COLOR TO MATCH EXISTING. REMOVE ALL PLATES BEFORE PAINTING AND REATTACH AFTERWARDS. FG3. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. FG4. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS TO MATCH VINYL BASE COLOR. (WHERE VCT MEETS CARPET) FG5. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. FG6. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURED. = AREAS N.I.C. NO SCALE IN PLAN =- ARCUTTFC,TURAT, FTNTSHFS SECOND FLOOR N Revisions: `��`01 �``` ~'GIS,`` =" 910039 '0 STATE (F D104 'mt I I Issue: STATE SUBMITTAL ISSUE a a I m ARCH. FINISHES 1KEY NOTES F01 NOT USED F02 NEW COMMON CORRIDOR. LANDLORD WILL PROVIDE NEW BUILDING STANDARD FINISHES. = AREAS N.I.C. NO SCALE IN PLAN =- ARCUTTFC,TURAT, FTNTSHFS SECOND FLOOR N Revisions: `��`01 �``` ~'GIS,`` =" 910039 '0 STATE (F D104 'mt I I Issue: STATE SUBMITTAL ISSUE a a I m ELECTRIC LIGHTING F__NONE ELECTRIC LIGHTING LEGEND 5T,'F'' i G1No (� NEW LIGHT FIXTURE, EXIST. DIFFUSER, ®EXIST. SLOT 2'x4', PARABOLIC --y--- --r- 2'x4' FLUORESCENT, T8 0 LAMPS NIGHT LIGHT LOCATION NEW LIGHT FIXTURE, INCANDESCENT, CAN NEW OR RELOCATED LIGHT FIXTURE, 0 EMERGENCY Issue: ® NEW OR RELOCATED Ul LIGHT FIXTURE, EXIT $N NEW LIGHT SWITCH EXIST. LIGHT SWITCH $ND NEW DIMMER SWITCH Date: 09.10.2004 NEW LIGHT CIRCUIT EXIST. LIGHT CIRCUIT ELECTRIC LIGHTING GENERAL NOTES ELI. ELECTRIC LIGHTING WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, FUNCTIONAL SYSTEM. EL2. COMPLY WITH THE INDIANA ELECTRICAL CODE AND ALL OTHER APPLICABLE CODES. EL3. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. EL4. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A. REQUIREMENTS. EL5. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. EL6. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE IF REQUIRED. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. EL7. PROVIDE EXIT SIGNS, HORNS, STROBES, SPEAKERS, OR OTHER LIFE -SAFETY DEVICES AS NECESSARY TO MEET ALL APPLICABLE CODES. EL8. IF REQUIRED AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING SPACES. H.V,A.C. GENERAL NOTES M1. H.V.A.C. WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A FUNCTIONAL, COMFORTABLE ENVIRONMENT AND A COMPLETE, WORKING SYSTEM. M2. COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. M3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. M4. REVISE ZONING IF REQUIRED. DO NOT DE31GN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE. M5. RELOCATE AIR -SUPPLY DIFFUSERS AND RETURN -AIR GRILLES AS REQUIRED. PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. M6. POSITION AND COORDINATE THERMOSTATS WITH TENANT'S FURNITURE AND WITH BUILDING OWNER. REFLECTED CEILING 0 ' 4' 8' 16' 24' SCALE: 1/8" = 1'-0" REFLECTED CEILING GENERAL NOTES RC1. REUSE EXISTING CEILING GRID AND TILE. EXISTING GRID IS 2'X4' AT f10' -O" A.F.F. TILES ARE 2'X4' FISSURED ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED CEILING TILES WITH NEW TO MATCH EXISTING. REFLECTED CEILING HS.A.C. LEGEND 5T,'F'' i G1No NEW OR RELOCATED ®� DIFFUSER, LAY -IN, SLOT NEW DIFFUSER, LAY -IN, 2'x2' EXIST. DIFFUSER, ®EXIST. SLOT IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW EQUIPMENT. --y--- --r- 2'x4' H.V,A.C. GENERAL NOTES M1. H.V.A.C. WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A FUNCTIONAL, COMFORTABLE ENVIRONMENT AND A COMPLETE, WORKING SYSTEM. M2. COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. M3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. M4. REVISE ZONING IF REQUIRED. DO NOT DE31GN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE. M5. RELOCATE AIR -SUPPLY DIFFUSERS AND RETURN -AIR GRILLES AS REQUIRED. PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. M6. POSITION AND COORDINATE THERMOSTATS WITH TENANT'S FURNITURE AND WITH BUILDING OWNER. REFLECTED CEILING 0 ' 4' 8' 16' 24' SCALE: 1/8" = 1'-0" REFLECTED CEILING GENERAL NOTES RC1. REUSE EXISTING CEILING GRID AND TILE. EXISTING GRID IS 2'X4' AT f10' -O" A.F.F. TILES ARE 2'X4' FISSURED ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED CEILING TILES WITH NEW TO MATCH EXISTING. REFLECTED CEILING LEGEND 5T,'F'' i G1No -----� - EXIST. CEILING GRID, SUSPENDED, --y--- --r- 2'x4' FIRE PROTECTION GENERAL NOTES FP1. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. FP2. COMPLY WITH THE INDIANA BUILDING CODE AND ALL OTHER APPLICABLE CODES FOR FIRE PROTCTION. FP3. FILE APPROPRIATE DRAWINGS WITH STATE AND CITY OFFICIALS. FP4. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. FP5. PROVIDE MISSING COVER PLATES FOR SPRINKLER HEADS WITHOUT PLATES. FIELD VERIFY EXISTING CONDITIONS. W M O p HQ^ti zoom w<mm UF5� z�z - M M QJ I'm a GOQX C,a< ? U. Revisions: rE­4 V W T� 1� x w� �a w �y V a� �w 110.4 aw 44 V z ;Ia 5T,'F'' i G1No 910039 0 STATE CF Dam %tII 0 Issue: KEY PLAN Ul 0 NO SCALE Date: 09.10.2004 SECOND FLOOR N Sheet: MERIDIAN TOWER DoE 201 W. 103RD ST. XZVT T rl A DAT A 1 31 P-04 5 s� w U 0.4 N E -4a C 0 Q) 0 Revisions: rE­4 V W T� 1� x w� �a w �y V a� �w 110.4 aw 44 V z ;Ia m 0 a w 0 0 0 5T,'F'' i G1No 910039 ' STATE CF Dam %tII Issue: KEY PLAN STATE SUBMITTAL ISSUE NO SCALE Date: 09.10.2004 SECOND FLOOR N Sheet: MERIDIAN TOWER 201 W. 103RD ST. XZVT T rl A DAT A 1 31 m 0 a w 0 0 0 4j" TYPICAL WALL TYPE i METAL STUD TYPICAL AT ALL EXTERIOR WALLS — 5/8" TYPE "X" GYPSUM BOARD FINISH BELOW EXISTING WINDOW \ i SILL COVER EXISTING WINDOW MULLION Ll UAL DETAIL — t11 SCALE: 1 -=l' -O" PREFINISHED ALUMINUM RECEIVER TRIM — FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF ACOUSTICAL SEALANT. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS UNE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT F1 SCALE: 1/4" = 1'-0" SEE SCHED. 1�1 0 LU 2 U N LU U.1 3'-4" 21�11 G i� " — H.M. KNOCK DOWN, PAINTED O i }11 / 4" TEMPERED GLASS D1 DOOR TYPESAf SCALE: 1/4" = 1'-0" No 910039 5'tAlE OF Issue: 0 W m O p U C,4 HQ ti n Z�co co<coc) mor tH M CO Q J CO QJX NpWQ rnz�-LL 0 DDDR SCHEDULE NO. DIMENSIONS DOORS FRAME HDWR. SET REMARKS TYPE MATERIAL FINISH TYPE MATERIAL FINISH 01 3' -0"x7' -0"x1-3/4" D1 50UD CORE WOOD VENEER STAINER BLONDE F2 KNOCK DOWN HOLLOW METAL PAINTED #3 03 3' -0"x7' -0"x1-3/4" D1 WppDDVENEER BLONDED F2 HOLLOW METAL STAINED #3, #6 00 04 3' -0'x7' -0"x1-3/4" D1 VY00QpVENEER BLONDE F2 HOLLOW DOWN �. PAINTED #3, #6 05 3' -0'x7' -0"x1-3/4" D1 ID CORE' WOOD VENEER SOLORE STAINED BLONDE F2 KNOCK DOWN HOLLOW METAL PAINTED #3, #6 06 3' -0"x7' -0"x1-3/4" D1 WpOpD�NEER TAINED BLONDE F2 WMETAL HOLLORE PAINTED #3, #6 07 3' -0"x7' -0"x1-3/4" D1 WOOD SOLID VCENEER TAI BLONDE F I HOLLOWMETAL PAINTED #3, #6 08 3'-0"x7'-0"xt-3/4° D1 W00DDVENEER STAINED F2 HOLKNOCK LOW METAL PAINTED #3, #6 09 3' -0"x7' -0"x1-3/4" Dl yyppp VCENEER STAINED F2 KNOCKDOWN OETAL FAINTED #3, #6 M� h+y 11 3' -0"x7' -0"x1-3/4" D1 SOLID CORE WOOD VENEER STAINED BLONDE F1 KNOCK DOWN HOLLOW METAL PAINTED #4 12 3' -0"x8' -10"x1-3/4" D1 SOLID CORE WOOD VENEER * F1 KNOCK DOWN HOLLOW METAL * PAINTED #1 *NOTE: STAIN INTERIOR SIDE BLONDE &PUBLIC CORRIDOR SIDE WALNUT &PAINT FRAME 2 SIDED TO MATCH ADJACENT FINISHES. SHED CHROME FINISH; MOUNT PR DUMMY KNOBS AT +66 A.F.F. 5. NOT USED. fi. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS FOR LOCKSETS. INSTALL LANDORD—FURNISHED CORES FOR LOCKSETS. HARDWARE SETS: DOOR AND FRAME NATES: HARDWARE SET 41 HARDWARE SET #2 HARDWARE SET #3 HARDWARE SET #4 1. REUSE DOORS FROM EXISTING BUILDING STOCK WHERE POSSIBLE (OBTAIN FROM -OTHER 3 BUTT HINGES 4 BUTT HINGES 3 BUTT HINGES 3 BUTT HINGES FLOORS -REFER TO LANDLORD). PROVIDE NEW INTERIOR GRADE WOOD DOORS AS REQUIRED. 1 ENTRY/EXIT LOCKSET 1 ENTRY/EXIT LOCKSET 1 PASSAGE LATCHSET 1 OFFICE LOCKSET MATCH BUILDING STANDARD SOLID CORE, WOOD VENEER DOORS STAINED BLONDE TO MATCH 1 WALL STOP 1 SET SILENCERS 1 WALL STOP 1 WALL STOP BUILDING STANDARD. ARE—MACHINE NEW DOORS FOR BORED LOCKSETS. 1 SET SILENCERS 1 CLOSER ON ACTIVE LEAF 1 SET SILENCERS 1 SET SILENCER 1 CLOSER TOP &BOTTOM FLUSH BOLTS 2. PROVIDE NEW HARDWARE ON NEW DOORS. REUSE EXISTING HARDWARE ON EXISTING CARD READER BY TENANT 1 WOOD ASTRAGAL DOORS WHERE POSSIBLE. POLISHED CHROME FINISH, TO MATCH BUILDING STANDARD. 1 DUST PROOF STRIKE PLATE PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON LOCK AND LATCHSETS. CARD READER BY TENANT 3. PROVIDE NEW BUILDING STANDARD H.M. KNOCK DOWN FRAMES AS REQUIRED. REUSE EXISTING FROM BUILDING STOCK WHERE POSSIBLE. HARDWARE SET #5 HARDWARE SET #6 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS 1 TOP ROLLER LATCHES DOUBLE COAT &HAT HOOK OTHERWISE NOTED ON PLAN. fi BUTT HINGES POLI F1 SCALE: 1/4" = 1'-0" SEE SCHED. 1�1 0 LU 2 U N LU U.1 3'-4" 21�11 G i� " — H.M. KNOCK DOWN, PAINTED O i }11 / 4" TEMPERED GLASS D1 DOOR TYPESAf SCALE: 1/4" = 1'-0" No 910039 5'tAlE OF Issue: 0 W m O p U C,4 HQ ti n Z�co co<coc) mor tH M CO Q J CO QJX NpWQ rnz�-LL 0 0 0 �o C tw w V 00 0�� t� w !o k z Em MA 0-4 IN 04 M� h+y 0 c h'1 0 SHED CHROME FINISH; MOUNT PR DUMMY KNOBS AT +66 A.F.F. 5. NOT USED. fi. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS FOR LOCKSETS. INSTALL LANDORD—FURNISHED CORES FOR LOCKSETS. F1 SCALE: 1/4" = 1'-0" SEE SCHED. 1�1 0 LU 2 U N LU U.1 3'-4" 21�11 G i� " — H.M. KNOCK DOWN, PAINTED O i }11 / 4" TEMPERED GLASS D1 DOOR TYPESAf SCALE: 1/4" = 1'-0" No 910039 5'tAlE OF Issue: 0 W m O p U C,4 HQ ti n Z�co co<coc) mor tH M CO Q J CO QJX NpWQ rnz�-LL 0 0 0 �o C tw w V 00 0�� t� w !o k z Em MA 0-4 IN 04 M� h+y 0 c h'1 0 Revisions: U] z 0 F CO a W E aW WA z.4!4 W E AH WU x� �x 0 0 a STATE .SUBMITTAL ISSUE Date: 09.10.2004 Sheet: MWEA&I r I' I WO bv.t. mai F2072 PLAN — ELECTRIC POWER ELECTRICAL POWER GENERAL NOTES EP1. ELECTRIC POWER WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. EP2. COMPLY WITH THE INDIANA ELECTRICAL CODE AND ALL OTHER APPLICABLE CODES. EP3. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. EP4. PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED. EP5. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA AND LAN CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT FACE PI.ATE. EP6. PROVIDE ALMOND COLORED FACEPLATES FOR ELECTRICAL OUTLETS TO MATCH EXISTING. EP7. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED. SUCH REFERENCED ITEMS ARE USUALLY SHOWN WITH DASHED LINES ON THIS DRAWING. PROVIDE ELECTRIC POWER TO, BUT NOT THROUGH OFFICE PARTITIONS SYSTEMS. = AREAS N.I.C. KEY P NO SCALE N SECOND FLOOR N Revisions: �G1STEj�;.. cif �y No. : �►_ 910039 �o STATE CF DAM %ItIIvn -' Issue: STATE SUBMITTAL ISSUE r f I r r a r 0 I NEW OWER OUTLET, EXIST. POWER OUTLET, DUPLE DUPLEX EXIST. POWER OUTLET, QUADRUPLEX 10 NEW BOX, EXIST. BOX, (B)LANK FOR OWERJSUPPLYON COVER PLAT © EXIST. BOX, (B)LANK COVER PLATE D DENOTES DEDICATED D DENOTES DEDICATED CIRCUIT CIRCUIT DENOTES GROUND DENOTES GROUND GFCI FAULT CICUIT GFCI FAULT CICUIT INTERRUPT OUTLET INTERRUPT OUTLET DENOTES HEIGHT OF DENOTES HEIGHT OF +42" ELECTRICAL OR DATA +42" ELECTRICAL OR DATA DEVICE DEVICE NEW DATA/ COMMUN- ICATION OUTLET a EXISTING DATA/ (PROVIDE BOX AND A COMMUNICATION DEVICE. PULL STRING ONLY) NEW BOX, (J)UNCTION FOR DATA SUPPLY IF IN GOOD CONDITION, EXISTING ELECTRICAL DEVICES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW EQUIPMENT. = AREAS N.I.C. KEY P NO SCALE N SECOND FLOOR N Revisions: �G1STEj�;.. cif �y No. : �►_ 910039 �o STATE CF DAM %ItIIvn -' Issue: STATE SUBMITTAL ISSUE r f I r r a r 0 I