Loading...
HomeMy WebLinkAboutA000.31900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone Office........................ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2018 JOEL HAMPSHIRE 03/01/2016 RIGHT MEADOWVIEW 2058.300.00.CPM LOT 200 01/30/2018 PLOTTED: March 1, 2018 / Rudolph Sanchez / 2058-MEADOWVIEW-IN-WCLY-EL-FE3G.DWG A3-FE3G 3SB.1French Eclectic3 Car GarageFront, Side and Rear Elevations,Roof Plan and Ventilation ScheduleSCALE:FRONT ELEVATION1/4" = 1'-0"- TOP OF FOUNDATION TOP OF FLOOR TOP OF PLATE WINDOW HEAD HGT. WINDOW HEAD HGT. TOP OF PLATE TOP OF FLOOR \A1;10'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" 1212 1212 12121212 ROOF SHINGLES, PER SPEC 6" FASCIA BOARD, PER SPEC4" CORNER BOARD, PER SPEC6" TRIM, PER SPECBRICK VENEER, PER SPEC 6" FASCIA BOARD, PER SPEC 4" STONE SILL, PER SPECSTONE VENEER, PER SPEC BRICK SOLDIER, PER SPEC BRICK VENEER, PER SPEC BRICK VENEER, PER SPEC ROOF SHINGLES, PER SPEC 3.5:1210:12 1212 \A1;2'-2{\H0.750000x;\S7#8;}"\A1;TYP. 8" TRIM, PRE SPEC 1212 1212 14" SHUTTER, PER SPEC 1241241212 126126 SCALE:REAR ELEVATION1/8" = 1'-0" TOP OF FOUNDATIONTOP OF FLOOR TOP OF PLATETOP OF FLOOR TOP OF PLATE TOP OF SLABTOP OF FOUNDATIONWINDOW HEAD HT.\A1;8'-6"\A1;3'-4"\A1;6'-7" ROOF SHINGLES,\PPER SPEC \A1;10'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" SCALE:LEFT ELEVATION1/8" = 1'-0" 124 10121012 123.5 1012 1012 1012126 SCALE:RIGHT ELEVATION1/8" = 1'-0" 10121012 124124 124 1012 126 SCALE:ROOF PLAN1/8" = 1'-0"- 6:126:12 12:1212:12 12:1212:12 10:12 12:1212:12 10:12 10:12 4:124:12 4:12 \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP.\A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. 12:1210:12 3.5:1210:12 ROOF AREASQ. FT."C"325 ROOF AREASQ. FT."A"3151 ROOF AREASQ. FT."B"302 \A1;4'-0" 4:1210:12 4:12 10:12 \A1;4'-0" 10:1210:12 10:12 10:12 10:1210:12 ELEVATION NC3G ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3151 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.20 5.25 6.35 60.40 15 0 AT EAVE 6.30 5.25 4.17 39.60 0 60.00 TOTAL (MIN)10.50 10.50 10.52 100.00 3 HIGH - RIDGE VENT 4.20 5.25 7.49 64.24 10 0 26.00 AT EAVE 6.30 5.25 4.17 35.76 0 60.00 TOTAL (MIN)10.50 10.50 11.65 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION NC3G ROOF AREA "B"SQ FTG 302 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.40 0.50 0.56 44.44 0 2 AT EAVE 0.60 0.50 0.69 55.56 0 10.00 TOTAL (MIN)1.01 1.01 1.25 100.00 3 HIGH - RIDGE VENT 0.40 0.50 0.50 41.86 0 0 4.00 AT EAVE 0.60 0.50 0.69 58.14 0 10.00 TOTAL (MIN)1.01 1.01 1.19 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION NC3G ROOF AREA "C"SQ FTG 332 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.44 0.55 0.56 40.00 0 2 AT EAVE 0.66 0.55 0.83 60.00 0 12.00 TOTAL (MIN)1.11 1.11 1.39 100.00 3 HIGH - RIDGE VENT 0.44 0.55 0.50 37.50 0 0 4.00 AT EAVE 0.66 0.55 0.83 62.50 0 12.00 TOTAL (MIN)1.11 1.11 1.33 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 04/17/18 Adam Schriner