HomeMy WebLinkAboutA000.31900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone Office........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2018
JOEL HAMPSHIRE 03/01/2016
RIGHT
MEADOWVIEW
2058.300.00.CPM
LOT 200
01/30/2018
PLOTTED: March 1, 2018 / Rudolph Sanchez / 2058-MEADOWVIEW-IN-WCLY-EL-FE3G.DWG
A3-FE3G
3SB.1French Eclectic3 Car GarageFront, Side and Rear Elevations,Roof Plan and Ventilation ScheduleSCALE:FRONT ELEVATION1/4" = 1'-0"-
TOP OF FOUNDATION
TOP OF FLOOR
TOP OF PLATE
WINDOW HEAD HGT.
WINDOW HEAD HGT.
TOP OF PLATE
TOP OF FLOOR
\A1;10'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
1212 1212 12121212 ROOF SHINGLES, PER SPEC
6" FASCIA BOARD, PER SPEC4" CORNER BOARD, PER SPEC6" TRIM, PER SPECBRICK VENEER, PER SPEC
6" FASCIA BOARD, PER SPEC
4" STONE SILL, PER SPECSTONE VENEER, PER SPEC
BRICK SOLDIER, PER SPEC
BRICK VENEER, PER SPEC
BRICK VENEER, PER SPEC
ROOF SHINGLES, PER SPEC
3.5:1210:12
1212
\A1;2'-2{\H0.750000x;\S7#8;}"\A1;TYP.
8" TRIM, PRE SPEC
1212
1212
14" SHUTTER, PER SPEC
1241241212
126126
SCALE:REAR ELEVATION1/8" = 1'-0"
TOP OF FOUNDATIONTOP OF FLOOR
TOP OF PLATETOP OF FLOOR
TOP OF PLATE
TOP OF SLABTOP OF FOUNDATIONWINDOW HEAD HT.\A1;8'-6"\A1;3'-4"\A1;6'-7"
ROOF SHINGLES,\PPER SPEC
\A1;10'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
SCALE:LEFT ELEVATION1/8" = 1'-0"
124
10121012
123.5
1012
1012
1012126
SCALE:RIGHT ELEVATION1/8" = 1'-0"
10121012
124124 124
1012
126
SCALE:ROOF PLAN1/8" = 1'-0"-
6:126:12
12:1212:12
12:1212:12
10:12
12:1212:12
10:12
10:12
4:124:12
4:12 \A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
12:1210:12
3.5:1210:12
ROOF AREASQ. FT."C"325
ROOF AREASQ. FT."A"3151
ROOF AREASQ. FT."B"302
\A1;4'-0"
4:1210:12
4:12
10:12
\A1;4'-0"
10:1210:12 10:12
10:12
10:1210:12
ELEVATION NC3G
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3151 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.20 5.25 6.35 60.40 15 0
AT EAVE 6.30 5.25 4.17 39.60 0 60.00
TOTAL (MIN)10.50 10.50 10.52 100.00
3
HIGH -
RIDGE VENT 4.20 5.25 7.49 64.24 10 0 26.00
AT EAVE 6.30 5.25 4.17 35.76 0 60.00
TOTAL (MIN)10.50 10.50 11.65 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ELEVATION NC3G
ROOF AREA "B"SQ FTG 302 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.40 0.50 0.56 44.44 0 2
AT EAVE 0.60 0.50 0.69 55.56 0 10.00
TOTAL (MIN)1.01 1.01 1.25 100.00
3
HIGH -
RIDGE VENT 0.40 0.50 0.50 41.86 0 0 4.00
AT EAVE 0.60 0.50 0.69 58.14 0 10.00
TOTAL (MIN)1.01 1.01 1.19 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ELEVATION NC3G
ROOF AREA "C"SQ FTG 332 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.44 0.55 0.56 40.00 0 2
AT EAVE 0.66 0.55 0.83 60.00 0 12.00
TOTAL (MIN)1.11 1.11 1.39 100.00
3
HIGH -
RIDGE VENT 0.44 0.55 0.50 37.50 0 0 4.00
AT EAVE 0.66 0.55 0.83 62.50 0 12.00
TOTAL (MIN)1.11 1.11 1.33 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
04/17/18
Adam Schriner