Loading...
HomeMy WebLinkAboutGN001LOT SPECIFIED PLAN INFORMATION Customer Name {\C256;* Market Home *, 5581-02300} Address{\C256;4423 VOYAGEUR WAY}{\Fsimplex|c0;\C256;CARMEL}{\C256;IN}{\C256;46074} Community{\Fsimplex|c0;\C256;5581}{\C256;BEAR CREEK ESTATES}{\C256;5581-02300}{\C256;LOTNUM 123} Plan Features{\C256;Elevation HR3S} MUNICIPALITY STRUCTURAL ENGINEER APPLICABLE CODES MECHANICAL ENGINEER BUILDING CODE ANALYSIS DESIGN LOADS and CRITERIA AREA CALCULATION (SQ. FT.) \pxt12;{\H0.92593x;BUILDING CODE:\PPLUMBING CODE: \P\pql;MECHANICAL CODE:\PFUEL AND GAS CODE:\P\pq*;ENERGY CODE:\PELECTRICAL CODE:\P\pql;FIRE CODE:\P\pt14;\P\pq*,tz;}1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE REQUIRED DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. VERIFY WITH THE LOCAL BUILDING AGENCIES THE WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. THE ARCHITECT SHALL BE NOTIFIED IN WRITING OF ALL DISCREPANCIES.\P\pa0.25;2. THERE SHALL BE NO STRUCTURAL CHANGES WITHOUT WRITTEN CONSENT OF THE ENGINEER OF RECORD.{\H0.92593x; } ZONING ORDINANCE: .\PUSE GROUP: .\PCONSTRUCTION CLASS: .\PHEIGHT & AREA: .\POTHER REQUIREMENTS: .\pxt20,28;LIVE LOADS:\P\pt2,r28; Sleeping ___ PSF\P Non-Sleeping ___ PSF\P Ext. Decks & Stairs ___ PSF\P\ptr28;DEAD LOAD: ___ PSF\P\pt2,r27; Guard Rail & Handrail ___ LB \P\pt2,r28; Guard Infill Components ___ PSF\P\ptr28;WIND SPEED: ___ MPH\PROOF LIVE LOAD: ___ PSF\PSNOW LOAD: ___ PSF\PLATERAL LOAD: ___ PCF \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} SHEET LIST TABLE SHT DESCRIPTION CC.01 Cover Sheet CC.02 Notes - Schedules and Legends A0.01 Foundation - Basement A1.11 1st Floor Plan A1.21 2nd Floor Plan A2.01 Building Section A2.02 Building Section A2.03 Building Section A3.01 Front Elevation A3.02 Left Elevation A3.03 Right Elevation A3.04 Rear Elevation A4.01 Roof Plan U0.01 Basement Utility Plan U1.11 1st Floor Utility Plan U1.21 2nd Floor Utility Plan Structural Plan - Foundation Basement (IN Code) Structural Plan - 1st Floor (IN Code) Structural Plan - 2nd Floor (IN Code)LOT SPECIFIC OPTION SELECTIONSOpt Boot Bench at Owner's EntryBuilt in Kitchen OptionElevation HR3SDen OptionBasement FoundationTraditional Fireplace at Gathering Room3 Car Side Load GarageOwner's Bath 4IndianaOpt SunroomOpt Basement Window Well - Location 1 SQUARE FOOTAGE TOTAL:CONDITIONED - LIVABLE SF 1st Floor 1st Floor - Sunroom 2nd Floor 1746 SF 168 SF 1777 SF 3691 SF TOTAL:CONDITIONED - NON-LIVABLE SF Basement - Unfinished Basement - Unfinished - Sunroom 1645 SF 156 SF 1801 SF TOTAL:UNCONDITIONED SF 3 Car Garage Side Front Porch 676 SF 145 SF 821 SF 6313 SF COVER SHEETMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPESingle Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Deer Valley 2107.300Home for * Market Home *, 5581-023004423 Voyageur Way, Carmel, IN 46074CC.01 04/18/18 William Hohlt