Loading...
HomeMy WebLinkAboutMEP COMcheckCOMcheck Software Version 4.0.8.0 Interior Lighting Compliance Certificate Project Title: 90.1 (2007) Standard Project Type: New Construction Construction Site: 1111 WEST MAIN STREET, SUIT 100 CARMEL, IN 46032 Owner/Agent: Paul Jordan Peterson Architecture 298 South 10th Street, Suite 500 Noblesville, IN 46060 317.770.9714 PJordan@petersonarchitecture.com Designer/Contractor: Earl Wade ("Bob") Boulware, PE, MBA Design-Aire Engineering 220 North College Avenue Indianapolis, IN 46202 317464-9090 dae@daengineering.com Project Information Energy Code: ROSIE'S PLACE Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Common Space Types:Dining Area - General 3800 0.90 3420 Total Allowed Watts = 3420 Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Common Space Types:Dining Area - General LED 1: Other: 1 6 48 288 LED 2: Other: 1 11 48 528 LED 3: Other: 1 3 24 72 LED 4: Other: 1 2 24 48 LED 5: Other: 1 2 24 48 Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.0.8.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES: Design 35% better than code Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 2 of 15 COMcheck Software Version 4.0.8.0 Exterior Lighting Compliance Certificate Project Title: 90.1 (2007) Standard Project Type: New Construction Construction Site: 1111 WEST MAIN STREET, SUIT 100 CARMEL, IN 46032 Owner/Agent: Paul Jordan Peterson Architecture 298 South 10th Street, Suite 500 Noblesville, IN 46060 317.770.9714 PJordan@petersonarchitecture.com Designer/Contractor: Earl Wade ("Bob") Boulware, PE, MBA Design-Aire Engineering 220 North College Avenue Indianapolis, IN 46202 317464-9090 dae@daengineering.com Project Information Energy Code: ROSIE'S PLACE Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Main entry/exit 1 ft of door 30 Yes 30 Other entry/exit 3 ft of door 20 Yes 60 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 90 90 4 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces. (b) A supplemental allowance equal to 5 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ COMcheck Software Version 4.0.8.0 Mechanical Compliance Certificate Project Title: 90.1 (2007) Standard Project Type: New Construction Location: Carmel, Indiana Climate Zone: 5a Construction Site: 1111 WEST MAIN STREET, SUIT 100 CARMEL, IN 46032 Owner/Agent: Paul Jordan Peterson Architecture 298 South 10th Street, Suite 500 Noblesville, IN 46060 317.770.9714 PJordan@petersonarchitecture.com Designer/Contractor: Earl Wade ("Bob") Boulware, PE, MBA Design-Aire Engineering 220 North College Avenue Indianapolis, IN 46202 317464-9090 dae@daengineering.com Project Information Energy Code: ROSIE'S PLACE Mechanical Systems List Quantity System Type & Description Heating: 1 each - Central Furnace, Electric, Capacity = 132 kBtu/h No minimum efficiency requirement applies Cooling: 1 each - Single Package DX Unit, Capacity = 60 kBtu/h, Air-Cooled Condenser Proposed Efficiency = 14.00 SEER, Required Efficiency: 13.00 SEER Fan System: None 1 HVAC System 1 (Single Zone): Heating: 1 each - Central Furnace, Electric, Capacity = 132 kBtu/h No minimum efficiency requirement applies Cooling: 1 each - Single Package DX Unit, Capacity = 59 kBtu/h, Air-Cooled Condenser Proposed Efficiency = 14.00 SEER, Required Efficiency: 13.00 SEER Fan System: None 1 HVAC System 2 (Single Zone): Heating: 1 each - Central Furnace, Electric, Capacity = 132 kBtu/h No minimum efficiency requirement applies Cooling: 1 each - Single Package DX Unit, Capacity = 59 kBtu/h, Air-Cooled Condenser Proposed Efficiency = 14.00 SEER, Required Efficiency: 13.00 SEER Fan System: None 1 HVAC System 3 (Single Zone): Heating: 1 each - Central Furnace, Electric, Capacity = 132 kBtu/h No minimum efficiency requirement applies Cooling: 1 each - Single Package DX Unit, Capacity = 56 kBtu/h, Air-Cooled Condenser Proposed Efficiency = 14.00 SEER, Required Efficiency: 13.00 SEER Fan System: None 1 HVAC System 4 (Single Zone): Heating: 1 each - Central Furnace, Electric, Capacity = 132 kBtu/h No minimum efficiency requirement applies Cooling: 1 each - Single Package DX Unit, Capacity = 55 kBtu/h, Air-Cooled Condenser Proposed Efficiency = 14.00 SEER, Required Efficiency: 13.00 SEER Fan System: None 1 HVAC System 5 (Single Zone): Quantity System Type & Description Electric Instantaneous Water Heater, Capacity: 0 gallons w/ Circulation Pump No minimum efficiency requirement applies Electric Instantaneous Water Heater, Capacity: 0 gallons w/ Circulation Pump No minimum efficiency requirement applies 1 Water Heater 2: Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.0.8.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 5 of 15 Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.0.8.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2007) Standard Section # & Req.ID Plan Review Complies? Comments/Assumptions 4.2.2, 6.4.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Complies Does Not Not Observable Not Applicable Requirement will be met. 4.2.2, 7.4.1 [PR3]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. Complies Does Not Not Observable Not Applicable Requirement will be met. 4.2.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Section # & Req.ID Footing / Foundation Inspection Complies? Comments/Assumptions 6.4.3.8 [FO9]3 Freeze protection and snow/ice melting system sensors for future connection to controls. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 7 of 15 Section # & Req.ID Plumbing Rough-In Inspection Complies? Comments/Assumptions 7.4.3 [PL1]2 Service hot-water piping systems insulated. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Requirement will be met. 7.4.3 [PL1]2 Service hot-water piping systems insulated. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Requirement will be met. 7.4.4.2 [PL3]1 Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. Complies Does Not Not Observable Not Applicable Requirement will be met. 7.4.4.2 [PL3]1 Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 8 of 15 Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 6.4.1.4, 6.4.1.5 [ME1]2 HVAC equipment efficiency verified. Non-NAECA HVAC equipment labeled as meeting 90.1. Efficiency:_____ Efficiency:_____ Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. 6.4.3.4.1 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.4.2, 6.4.3.4.3, 6.4.3.4.4 [ME4]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.4.5 [ME5]3 Ventilation fans >0.75 hp have automatic controls to shut off fan when not required. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.9 [ME6]1 Demand control ventilation Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.2.3 [ME19]3 Dehumidification controls provided to prevent reheating, recooling, mixing of hot and cold airstreams or concurrent heating and cooling of the same airstream. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.4.1 [ME25]3 HVAC pumping systems >10 hp designed for variable fluid flow. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.6.1 [ME30]1 Exhaust air energy recovery on systems >=5,000 cfm and 70% of design supply air. Complies Does Not Not Observable Not Applicable Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 6.5.9 [ME35]1 Hot gas bypass limited to: <=240 kBtu/h – 50% >240 kBtu/h – 25% Complies Does Not Not Observable Not Applicable Requirement will be met. 7.4.2 [ME36]2 Service water heating equipment meets efficiency requirements. Complies Does Not Not Observable Not Applicable 7.4.2 [ME36]2 Service water heating equipment meets efficiency requirements. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 11 of 15 Section # & Req.ID Rough-In Electrical Inspection Complies? Comments/Assumptions 9.4.1.1 [EL1]2 Automatic controls to shut off all building lighting installed in buildings >5,000 ft2. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.2 [EL2]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.3 [EL3]2 Automatic lighting controls for exterior lighting installed. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.2 [EL5]3 Ballasted one and three lamp fixtures with >30 W/lamp have two lamp tandem wired ballasts when >=2 fixtures in same space on same control. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.3 [EL6]1 Exit signs do not exceed 5 watts per face. Section # & Req.ID Final Inspection Complies? Comments/Assumptions 6.4.3.1.1 [FI2]2 Heating and cooling to each zone is controlled by a thermostat control. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.1.2, 6.4.3.2, 6.4.3.3, 6.4.3.3.1, 6.4.3.3.2 [FI3]2 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.7 [FI6]3 When humidification and dehumidification are provided to a zone, simultaneous operation is prohibited. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.1 [FI7]3 Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.2 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.3 [FI9]1 An air and/or hydronic system Section # & Req.ID Final Inspection Complies? Comments/Assumptions 8.7.2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.2.2.3 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. 9.4.5 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. 6.4.3.2 [FI20]1 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.3.1 [FI21]1 HVAC systems equipped with at least one automatic shutdown control. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.3.2 [FI22]1 Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 15 of 15 Setback controls allow automatic restart and temporary operation as required for maintenance. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 14 of 15 balancing report is provided for HVAC systems serving zones >5,000 ft2 of conditioned area. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.4 [FI10]1 HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Complies Does Not Not Observable Not Applicable Requirement will be met. 7.4.4.3 [FI11]3 Public lavatory faucet water temperature <=110°F. Complies Does Not Not Observable Not Applicable Requirement will be met. 7.4.4.3 [FI11]3 Public lavatory faucet water temperature <=110°F. Complies Does Not Not Observable Not Applicable Requirement will be met. 7.4.4.4 [FI12]3 Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank. Complies Does Not Not Observable Not Applicable Requirement will be met. 7.4.4.4 [FI12]3 Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank. Complies Does Not Not Observable Not Applicable Requirement will be met. 8.7.1 [FI16]3 Furnished as-built drawings for electric power systems within 30 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 13 of 15 Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.4 [EL7]1 Exterior grounds lighting over 100 W provides >60 lm/W unless on motion sensor or fixture is exempt from scope of code or from external LPD. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.6.2 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. 10.4.1 [EL9]2 Electric motors meet requirements where applicable. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 12 of 15 Requirement will be met. 6.5.7.1 [ME32]2 Kitchen hoods >5,000 cfm have make up air >=50% of exhaust air volume. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.7.2 [ME33]1 Fume hoods exhaust systems >=15,000 cfm have VAV hood exhaust and supply systems, direct make-up air or heat recovery. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.8.1 [ME34]3 Unenclosed spaces that are heated use only radiant heat. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.9 [ME35]1 Hot gas bypass limited to: <=240 kBtu/h – 50% >240 kBtu/h – 25% Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.9 [ME35]1 Hot gas bypass limited to: <=240 kBtu/h – 50% >240 kBtu/h – 25% Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.9 [ME35]1 Hot gas bypass limited to: <=240 kBtu/h – 50% >240 kBtu/h – 25% Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.9 [ME35]1 Hot gas bypass limited to: <=240 kBtu/h – 50% >240 kBtu/h – 25% Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 10 of 15 provided for spaces >500 ft2 and >40 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.1.1 [ME7]3 Insulation exposed to weather protected from damage. Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.1.2 [ME8]2 HVAC ducts and plenums insulated. R-_____ R-_____ Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.1.3 [ME9]2 HVAC piping insulation thickness. _____ in. _____ in. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.2.1 [ME10]2 Ducts and plenums sealed based on static pressure and location. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 9 of 15 Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.4 [PR5]1 Detailed instructions for HVAC systems commissioning included on the plans or specifications for projects >=50,000 ft2. Complies Does Not Not Observable Not Applicable Requirement will be met. 8.4.1.1, 8.4.1.2 [PR6]2 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 6 of 15 1 Water Heater 1: Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 4 of 15 Fixture C # of Fixtures Main entry/exit (1 ft of door width): Tradable Wattage LED 1: Other: 1 1 2 2 Other entry/exit (3 ft of door width): Tradable Wattage LED 2: Other: 1 3 2 4 Total Tradable Proposed Watts = 6 Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.0.8.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES: Design 94% better than code Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 3 of 15 LED 6: Other: 1 36 13 468 LED 7: Other: 1 10 13 130 LED 8: Other: 1 7 18 126 LED 9: Other: 1 15 15 225 LED 10: Other: 1 5 17 85 LED 11: Other: 1 6 12 72 LED 12: Other: 1 2 36 72 LED 13: Other: 1 7 9 63 Total Proposed Watts = 2225 Project Title: Data filename: ROSIE'S PLACE Z:\2017\17156-ROSIES CARMEL\COMcheck\COMcheck.cck Report date: 03/09/18 Page 1 of 15