HomeMy WebLinkAboutM003.32x4 Ledger
2x4 Ledger2x4 Ledger
2x4 Ledger2x4 LedgerPB1PBGBFB
P1(8)P(6)
G(3)F(4)1-09-042-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-03-092-00-009-112-00-002-00-002-00-002-00-00
2-00-00
2-00-00
2-00-00BG
CB
BB
DG
DB
AB2ABV1
V2
V3
V4
V5
V6
V7
V8
V9
V10
V11
V12HUS26
HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26HUS26C(2)B(3)D(3)A2(9) A1(2) A(3)2-00-002-00-001-05-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-00-001-05-082-00-00
2-00-00
1-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00 6-01-002-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
6-09-08Order #: 18030110
The Grove at Legacy - 3
7226 Broadcare Court
Carmel, Indiana 46033
Carter Lumber
2901 N. Morton St.
Franklin, Indiana 46131
(317) 346-1300
THIS IS A TRUSS PLACEMENT DIAGRAM ONLY.These trusses are designed as individual building components to be incorporated
into the building design at the specification of the buildingdesigner. Seeindividualdesignsheetsforeachtrussdesign identified onthe placement drawing. The building designer is responsiblefortemporaryandpermanentbracingoftheroofandfloorsystem andfor the overall structure. The design of the truss support structure including headers, beams, walls, and columns is the responsibility of
the building designer. For general guidance regarding bracing, consult "Bracing of Wood Trusses" available from the Truss PlateInstitute, 583 D'Onifrio Drive; Madison, WI 53179.
SHOP DRAWING APPROVALTHIS LAYOUT IS THE SOLE SOURCE FOR FABRICATION OF TRUSSES AND VOIDS ALL PREVIOUS ARCHITECTURAL OROTHER TRUSS LAYOUTS. REVIEW AND APPROVAL OF THIS LAYOUT MUST BE RECEIVED BEFORE ANY TRUSSES WILL
BE BUILT. VERIFY ALL CONDITIONS TO INSURE AGAINST CHANGES THAT WILL RESULT IN EXTRA CHARGES TO YOU.
REVIEWED BY:__________________________ APPROVED BY:______________________________ DATE:___________
Pyatt Builders
Scale: NTS Drawn By: K. BronnenbergDate: 3/26/18
Model
MurphyNotes:1) Valley trusses are designed to sit on sheathing.2) Installation of all temporary and permanent braces is essential.See truss drawings, BCSI-1 Building Component Safety informationand building designers requirements.3) Provide solid bearing for beams and girders. See Code and/orbuilding deigners requirements.4) Truss are NOT designed to be field modified unless notedotherwise. If any alterations are to be considered ALWAYS consultaqualifiedtrussdesignerorengineerBEFOREmakinganyalterations.5) Add/remove overhangs as needed.Multi-Ply Girder Truss:See drawing of multi-ply girders for fastening pattern to connect plysso they act as one. All plys must be fastened together before supportedtrusses or framing is attached to girders.Hangers:Install all hangers per manufacturers requirements.