Loading...
HomeMy WebLinkAboutA1.1 Architectural7'-5" 7'-6" 3 1 2 2 2 4 4 4 5 5 5 5 4'-0" 101 100 TENANT SPACE 100 RESTROOM 101 A1 A1 EXG EXG EXG EXG EXG 6 7 A1 8 PT-1 P-1 B-1 7 A8.1 7 A8.1 8 WP-1 1 A1.2 C-1 C-1 1 TENANT SPACE 100 RESTROOM 101 4 9'-0" 11'-6" A1.1 ARCHITECTURAL FLOOR AND FINISH PLAN 1/4" = 1'-0" 1 ARCHITECTURAL FLOOR PLAN AND REFLECTED CEILING PLAN SYMBOL DIAGRAM DESCRIPTION DETAIL RATING EXISTING WALL/PARTITION TO REMAIN NEW WALL/PARTITION FLOOR PLAN CODED NOTE (SEE SCHEDULE ON THIS SHEET) X WALL TYPE TAG (SEE SCHEDULE ON THIS SHEET) XX A. ALL UNMARKED WALLS SHALL BE THE SAME AS THE CLOSEST MARKED WALL TYPE. SEE THIS SHEET FOR WALL/PARTITION SCHEDULE. B. GENERAL CONTRACTOR TO PROVIDE ALL NEW WALLS INDICATED ON FLOOR PLAN. SEE WALL/PARTITION SCHEDULE FOR ALL WALL TYPES. C. ALL EXISTING WALLS AFFECTED BY DEMO WORK TO BE PATCHED AND REPAIRED. PROVIDE ASTM C840 LEVEL 4 FINISH UNLESS NOTED OTHERWISE. D. REFER TO MEP DRAWINGS FOR ADDITIONAL SCOPE OF WORK. GENERAL FLOOR PLAN NOTES ARCHITECTRUAL FLOOR PLN CODED NOTES WALL PARTITION SCHEDULE SYMBOL LEGEND WALL LEGEND X 1. EXISTING STRUCTURAL COLUMN TO REMAIN 2. EXISTING DEMISING WALL. TAPE, SPACKLE, AND SAND AS REQUIRED TO PROVIDE LEVEL 4 FINISH READY TO RECEIVE TENANT SELECTED FINISHES 3. EXISTING ELECTRICAL PANELS AND TRANSFORMER. REFER TO MEP DRAWINGS. 4. ADJACENT SPACE. N.I.C. 5. LEASE LINE 6. EXISTING EXTERIOR SIDEWALK 7. EXISTING STOREFRONT. 8. REMOVE EXTERIOR CERAMIC GLAZED TILE UNER STOREFRONT TO EXTERIOR SHEATHING. INSTALL NEW MASONRY VENEER PER MANUFACTURER'S INSTRUCTIONS. NOTES: 1. FIELD VERIFY ALL DIMENSIONS. DIMENSIONS ARE TO THE FACE SHEATHING UNLESS NOTED OTHERWISE. 2. PROVIDE VERTICAL CONTROL JOINTS AT 30'-0" O.C. MAX. SEE DETAILS 4/A1.2 AND 5/A1.2. 3. ALL PARTITIONS THAT ARE TO BE BUILT TO DECK SHALL INCLUDE ANY STRUCTURE (JOISTS, BEAMS, ETC.) THAT MAY NEED TO BE FRAMED OUT IN ORDER TO PROVIDE DRYWALL TO DECK. ALL PENETRATIONS AND FLUTES IN DECK SHALL BE SEALED AS REQUIRED. 4. PROVIDE A GALVANIZED STEEL SHEET DEEP LEG DEFLECTION TRACK (20 GA.), 'SLP-TRK' BY SLIPTRACK SYSTEMS, INC. AT ALL FRAMING THAT EXTENDS FROM THE SLAB TO THE UNDERSIDE OF THE STRUCTURE ABOVE. SECURE DEFLECTION TRACK TO STRUCTURE WITH FASTENERS AT 2'-0" O.C. MAXIMUM. DO NOT SECURE TRACK TO VERTICAL STUDS. PROVIDE MINIMUM OF 5/8" TO TOP OF METAL STUD. 5. ALL BOTTOM TRACK RUNNERS ARE TO BE HELD IN PLACE WITH FASTENERS AT 2'-0" O.C. MAX WITH HILTI POWER DRIVER ANCHOR ICBO #2388, .0145" DIAMETER SHANK WITH 1 1/8" MINIMUM PENETRATION. SEE DETAILS 4/A1.2 6. PROVIDE HORIZONTAL BRIDGING IN ALL PARTITION FRAMING AT A MINIMUM OF 6'-0" O.C. VERTICALLY. GENERAL CONTRACTOR TO COORDINATE WITH METAL STUD MANUFACTURER TO DETERMINE IF HORIZONTAL BRIDGING IS REQUIRED FOR METAL STUD PARTITION WALLS THAT HAVE GYPSUM BOARD ON BOTH SIDES THAT EXTEND FROM FINISHED FLOOR TO UNDERSIDE OF STRUCTURE ABOVE. 7. METAL STUD NON-STRUCTURAL WALL SYSTEMS ARE TO FOLLOW ASTM C754 & ASTM C645. 8. ALL GYPSUM BOARD IS TO BE 5/8" THICK UNLESS NOTED OTHERWISE. PROVIDE TYPE 'X' GYPSUM BOARD AT ALL FIRE RATED PARTITIONS. 9. TAPE, MUD, AND SAND GYPSUM BOARD SMOOTH READY FOR TENANT FINISHES AT INTERIOR FACE OF ALL GYPSUM BOARD SURFACES. PROVIDE ASTM C840 LEVEL 4 FINISH UNLESS NOTED OTHERWISE. 10. ALL PLYWOOD BLOCKING IS TO BE FIRE RETARDANT TREATED. 11. PROVIDE FIRE SAFING AT ALL PARTITION/FURRING CAVITIES AT CEILING LEVELS OPEN TO CEILING PLENUMS. 12'-0" A.F.F. A1 5/8" GYPSUM BOARD TO 1/2" ABOVE FRAMING 3 5/8" (20 GA) METAL STUDS @ 24" O.C. CONTINUOUS SOUND BATTS 5/8" GYPSUM BOARD TO 1/2" ABOVE FRAMING 8/A8.1 --- DOOR TAG (SEE SCHEDULE ON SHEET 8.1) XXX 14390 CLAY TERRACE BLVD re d CARMEL, INDIANA 46032 WPG007 SPACE F30A - LANDLORD IMPROVEMENTS PROJECT NUMBER: SHEET: FOR WASHINGTON PRIME GROUP 180 EAST BROAD STREET, COLUMBUS, OH 43215 ISSUE DATE PERMIT FEB. 01, 2018 COPYRIGHT 2018. ALL DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE + PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. A1.1 2/1/2018 9:36 AM A1.1 REFLECTED CEILING PLAN 1/4" = 1'-0" 2 # 1. EXISTING STRUCTURAL COLUMN TO REMAIN. 2. LIGHT FIXTURE. REFER TO ELECTRICAL PLANS. 3. MECHANICAL DIFFUSER. REFER TO MECHANICAL PLANS FOR ADDITIONAL INFORMATION. 4. EXISTING SOFFIT. REFLECTED CEILING PLAN CODED NOTES GENERAL NOTES 1. REFER TO ELECTRICAL DRAWINGS FOR LIGHT DETAILS 2. ALL EMERGENCY FIXTURES, LIGHTS AND STROBES SHALL BE ALIGNED OR CENTERED ON WALLS SYMBOL LEGEND FLOOR PLAN CODED NOTE (SEE SCHEDULE ON THIS SHEET) X X'-X" FINISH HEIGHT TAG NOTE- SEE MECHANICAL AND ELECTRICAL SHEETS FOR ALL FIXTURE SPECIFICATIONS, WIRING, AND POWER REQUIREMENTS. 24" x 24" SUPPLY AIR DIFFUSER (SEE MECHANICAL SHEETS) 24" x 24" RETURN AIR GRILLE (SEE MECHANICAL SHEETS) REFLECTED CEILING PLAN LEGEND ALL MODIFICATIONS TO SPRINKLER SYSTEM/ FIREALARM SYSTEM SHALL BE PERFORMED BY A LICENSED SPRINKLER/ FIRE ALARM CONTRACTOR UNDER A SEPARATE PERMIT AT DISCRETION OF CONTRACTOR 24" X 24" RECESSED TROUGH LIGHT REFER TO ELECTRICAL DRAWINGS 24" X 48" ACOUSTICAL CEILING TILE - ARMSTRONG 1851 DUNE OR APPROVED EQUAL. MARK MANUFACTURER DESCRIPTION NOTES WALL BASE RUBBER FINISH SCHEDULE TBD 4" COVE COLOR: TBD BY TENANT WALLS PT-1 SHERMANPAINT WILLIAMS COLOR: TBD BY TENANT B-1 WP-1 TBD FRP PANEL COLOR: TBD BY TENANT ARMSTRONG CEILING TILE COLOR: DUNE 1851 CEILING C-1 04/25/18 Nick Mishler