HomeMy WebLinkAboutA02191
4"
UNIT SIDE
UNIT SIDE
SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS.
UL DESIGNATION: U420
1-HOUR FIRE PARTITION (IBC 708)
47
8"
1'-4" 1'-4"
SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS.
81
4"
UL DESIGNATION: U419
1-HOUR FIRE PARTITION (IBC 708)
UNIT SIDE
CORRIDOR SIDE
71
4"
1'-4" 1'-4"
4
1
4"
1'-4" 1'-4"
"FURRED" WALL
UL DESIGNATION: U423
1-HOUR FIRE RATED DESIGN
3-5/8" MTL. STUD BOTTOM TRACK
3-5/8" MTL. STUDS AT 16" O.C.
3 1/2" SOUND ATTENUATION BLANKETS
FRICTION-FITTED TO COMPLETELY FILL THE
STUD CAVITIES
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
3-5/8" MTL. STUD TOP TRACK
UNIT SIDE UNIT SIDE
3-5/8" MTL. STUD BOTTOM TRACK
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
3-5/8" MTL. STUD TOP TRACK
6" MTL. STUD BOTTOM TRACK
3 5/8" MTL. STUDS 16" 0.C.
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
3 5/8" MTL. STUD TOP TRACK
1" RESILIENT CHANNEL
3" SA BATTS
UNIT50 SIDE CORRIDOR SIDE *MIN STC
6" MTL. STUD BOTTOM TRACK
6" MTL. STUDS 16" 0.C.
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
6" MTL. STUD TOP TRACK
3-5/8" MTL. STUD BOTTOM TRACK
3-5/8" MTL. STUD TOP TRACK
3-5/8" MTL. STUDS 16" 0.C.
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' ONE SIDE
3" SA BATTS AT RETAIL SPACE
3-5/8" MTL. STUD BOTTOM TRACK
3-5/8" MTL. STUD TOP TRACK
3-5/8" MTL. STUDS 16" 0.C.
FIRESTOPPED
(2) LAYERS 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
ACOUSTICAL SEALANT AT PERIMETER EACH SIDE
ACOUSTICAL SEALANT AT PERIMETER EACH SIDE
ACOUSTICAL SEALANT AT
PERIMETER EACH SIDE
ACOUSTICAL SEALANT AT PERIMETER EACH SIDE
NOTE: W14A INDICATES 6" FRAMING
SPECIFIED BASE
PRECAST TOPPING SLAB
SPECIFIED BASE
"S2A" - INDICATES 6" STEEL STUD
"S2B" - INDICATES
7
8" STEEL FURRING CHANNEL, OMIT INSULATION
"S2C" - INDICATES 1
1
2" STEEL FURRING CHANNEL, OMIT INSULATION
"S2D" - INDICATES 2
1
2: STEEL STUD
"S2E" - OMIT INSULATION
33
4"
1'-4" 1'-4"
(2) LAYES 5/8" GYPSUM WALL
BOARD TYPE 'X'
(1) LAYER 1" GYPSUM WALL
BOARD LINER PANEL
FIRE SEALANT
UL DESIGNATION: U415
2-HOUR FIRE PARTITION (IBC 708)
STC 38
FIRE SEALANT
2
1
2" STEEL 'J' RUNNER
2
1
2" STEEL 'J' RUNNER
CLOSED SIDE OPEN SIDE
CLOSED SIDE
OPEN SIDE
2
1
2" C-H STEEL STUD
S1 S2 S3 S4 S5 S6
"S7A" - INDICATES 4" C-H STEEL STUD S7
SERVICE ROOM FIRST LEVEL PODIUM
USE: FURRED WALL AT STAIR AND ELEVATOR SHAFTS FIRST
LEVEL PODIUM
USE: TYPICAL INTERIOR UNIT WALL FIRST LEVEL PODIUM USE: INTERIOR UNIT PLUMBING WALL 1ST. LEVEL PODIUM USE: CORRIDOR WALL 1ST. LEVEL PODIUM USE: UNIT DEMISING WALL FIRST LEVEL PODIUM
USE: VERTICAL SHAFTS
SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTION MANAGER ARCHITECT
17104
DECEMBER 8, 2017
ISSUED FOR CONSTRUCTION
MIDTOWN WEST
CARMEL, IN
CLIENT
# DESCRIPTION DATE
BARRETT AND
STOKELY, INC
INDIANAPOLIS, IN
D I L L O N
CONSTRUCTION
G R O U P
A021
INTERIOR WALL
TYPES
04/25/18
Nick Mishler