HomeMy WebLinkAboutA02243 4" 63 4" 41 8" 2X4 WD. BOTTOM PLATE (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 1'-4" 1'-4" 2X6 WD. BOTTOM PLATE 2X6 WD. STUDS 16" 0.C. (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 1'-4" 1'-4" 1'-4" 1'-4" 2X4 WD. BOTTOM PLATE 2X4 WD. DBL. TOP PLATE 2X4 WD. STUDS 16" 0.C. (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' ONE SIDE 63 16" UL DESIGNATION: U344 1-HOUR FIRE PARTITION (IBC 708) 2X4 WD. BOTTOM PLATE 2X6 WD. STUDS 16" 0.C. (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE (1) LAYER 7/16" OSB ONE SIDE. SEE STRUCTURAL SHEETS FOR LOCATION AND NAILING PATTERN. 2X4 WD. DBL. TOP PLATE SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS. 1 2" RESILIENT CHANNEL 2X4PLATE WD. DBL. TOP PLATE 2X6 WD. DBL. TOP UNIT SIDE UNIT SIDE CORRIDOR SIDE 3" SA BATTS *MIN STC 50 UNIT SIDE 91 4" SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS. 2X4 WD. BOTTOM PLATE 2X4 WD. STUDS AT 16" O.C. 3 1/2" SOUND ATTENUATION BLANKETS FRICTION-FITTED TO COMPLETELY FILL THE STUD CAVITIES (1) LAYER 7/16" OSB. SEE STRUCTURAL SHEETS FOR LOCATION AND NAILING PATTERN (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 2X4 WD. DBL. TOP PLATE UL DESIGNATION: U341 1-HOUR FIRE PARTITION (IBC 708) "FURRED" WALL 3" SA BATTS UNITSIDE SIDE CORRIDOR SIDE UNIT SIDE UNIT "W2A" - INDICATES 2X6 FRAMING ACOUSTICAL SEALANT AT PERIMETER EACH SIDE ACOUSTICALSIDE SEALANT AT ACOUSTICAL SEALANT AT PERIMETER EACH PERIMETER EACH SIDE RATED SEALANT AT PERIMETER EACH SIDE 3/MAT4" GYP-CRETE OVER ACOUSTIC MAT 3/4" GYP-CRETE OVER ACOUSTIC 3/MAT4" GYP-CRETE OVER ACOUSTIC MAT 3/MAT4" GYP-CRETE OVER ACOUSTIC 3/4" GYP-CRETE OVER ACOUSTIC 6" UL DESIGNATION: U301 2-HOUR FIRE BARRIER (IBC 707) 2X4 WD. BOTTOM PLATE 2X4 WD. DBL. TOP PLATE 2X4 WD. STUDS 16" 0.C. FIRESTOPPED (2) LAYERS 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 1'-4" 1'-4" 3/4" GYP-CRETE OVER ACOUSTIC MAT FIRE RATINGS FOR CONCRETE MASONRY UNITS (*) INDICATES FIRE RATING USING EQUIVALENT THICKNESS METHOD UNIT WIDTH (NOM) BLOCK TYPE FACE SHELL % SOLID EQUIVALENT THICKNESS FIRE RATINGS - HOURS NORMAL WEIGHT CONCRETE (Siliceous Gravel) MEDIUM WEIGHT (105-125 lb. per cubic ft. blended) LIGHT WEIGHT (Under 105 lbs. per cubic ft.) (Expanded clay, shale or slate) 4 4 6 6 6 8 8 8 8 8 10 12 12 3 CORE REGULAR SOLID 2 CORE REGULAR 3 CORE 75% SOLID SOLID 2 CORE REGULAR 2 CORE 58% SOLID 2 CORE 62% SOLID 3 CORE 75% SOLID SOLID 2 CORE REGULAR 2 CORE REGULAR 2 CORE 56% SOLID 1.0" SOLID SOLID SOLID 1.06" 2.0" 1.25" 1.5" 1.5" 2.25" 1.25" 1.5" 2.125" 76% 100% 56% 75% 100% 100% 53% 58% 62% 75% 51% 50% 50% 2.7 3.6 3.1 4.2 5.6 4.0 4.4 4.7 5.7 7.6 4.9 5.8 6.5 3/4 * 1-1/2* 1* 3* 1-1/2 1* 1-1/2* 1* 3-3/4* 2 - UL U905 2 - UL U905 1* 1-1/2* 1* 4* 2 - UL U905 2 - UL U905 3 - UL U904 4 - UL U901 4 - UL U901 3 - UL U904 15 8" 2'-0" 1" STEEL 'Z' FURRING STRIP (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' ONE SIDE "FURRED" WALL 3/4" GYP-CRETE OVER ACOUSTIC MAT W1 W2 W3 W7 W4 W5 W6 2 - UL U905 2 - UL U905 2 - UL U905 3 - UL U904 3 - UL U904 4 - UL U901 4 - UL U901 2 - UL U905 2 - UL U905 3 - UL U904 3 - UL U904 4 - UL U901 4 - UL U901 4U901 - UL U901 4 - UL 2 - UL U906 2 - UL U906 2 - UL U906 75 8" NOMINAL 8" CMU WALL. SEE STRUCTURAL DWGS FOR GROUT & REINFORCING. SEE "FIRE RATING FOR CONCRETE MANSONRY UNITS" TABLE FOR FIRE RATING INFO. M1 "M1A" - 1 1/2 HR. FIRE RATED "M1B" - 2 HR. FIRE RATED "M1C" - 3 HR. FIRE RATED "M1D" - 4 HR. FIRE RATED 1'-01 4" UNIT SIDE UNIT SIDE SEE STRUCTURAL DWGS. UL DESIGNATION: U336 CONFIGURATION B 2-HOUR AREA SEPARATION WALL (IBC 706) 2x4 WOOD STUDS AT 16" O.C. 3 1/2" SOUND ATTENUATION BLANKETS FRICTION-FITTED TO COMPLETELY FILL THE STUD CAVITIES (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 2x4 WOOD STUDS UNIT SIDE UNIT SIDE RATED SEALANT AT PERIMETER EACH SIDE RATED SEALANT AT PERIMETER EACH SIDE SPECIFIED BASE W8 2 CONTINUOUS LAYERS 1"x24" TYPE 'X' GYPSUM PANELS WITH STEEL H STUDS. PROVIDE ALUM. CLIPS BETWEEN H STUDS AND WALL FRAMING MIN. 3 4" AIR SPACE USE: CMU / CIP WALL FURRING AT CORRIDOR NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED USE: FIRST FLOOR SERVICE ROOMS "W2B" - OMIT INSULATION USE: FURRED WALL AT ELEVATORS AND STAIRS NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED USE: TYPICAL INTERIOR UNIT WALL "x" INDICATES 1 HR RATING NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED USE: TYPICAL INTERIOR UNIT WALL WITH PLUMBING "x" INDICATES 1 HR RATING NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED USE: TYPICAL CORRIDOR WALL "p" INDICATES WALL HAS PLUMBING "t" INDICATES "TALL" WALL - CHANGE TO 2 X 6 FRAMING AND ALIGN INTERIOR SHEATHING NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED USE: UNIT DEMISING WALL "p" INDICATES WALL HAS PLUMBING "t" INDICATES "TALL" WALL - CHANGE TO 2 X 6 FRAMING AND ALIGN INTERIOR SHEATHING "t" INDICATES TALL WALL. USE 2x6 STUDS. ALIGN EXTERIOR AND INTERIOR WALL FINISHES. NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED USE: RATED SERVICE ROOM NOTE: FIRST FLOOR TO BE FIRE-RETARDENT TREATED USE: FIRE RATED AREA SEPARATION WALL "p" INDICATES WALL HAS PLUMBING "t" INDICATES "TALL" WALL - CHANGE TO 2 X 6 FRAMING AND ALIGN INTERIOR SHEATHING "t" INDICATES TALL WALL. USE 2x6 STUDS. ALIGN EXTERIOR AND INTERIOR WALL FINISHES. NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED 1" RIGID INSULATION SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTIONARCHITECT MANAGER 17104 DECEMBER 8, 2017 ISSUED FOR CONSTRUCTION MIDTOWN WEST CARMEL, IN CLIENT # DESCRIPTION DATE BARRETT AND STOKELY, INC INDIANAPOLIS, IN D I L L O N CONSTRUCTION G R O U P A022 04/25/18 Nick Mishler