HomeMy WebLinkAboutA02243
4"
63
4"
41
8"
2X4 WD. BOTTOM PLATE
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
1'-4" 1'-4"
2X6 WD. BOTTOM PLATE
2X6 WD. STUDS 16" 0.C.
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
1'-4" 1'-4"
1'-4" 1'-4"
2X4 WD. BOTTOM PLATE
2X4 WD. DBL. TOP PLATE
2X4 WD. STUDS 16" 0.C.
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' ONE SIDE
63
16"
UL DESIGNATION: U344
1-HOUR FIRE PARTITION (IBC 708)
2X4 WD. BOTTOM PLATE
2X6 WD. STUDS 16" 0.C.
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
(1) LAYER 7/16" OSB ONE SIDE. SEE
STRUCTURAL SHEETS FOR LOCATION AND
NAILING PATTERN.
2X4 WD. DBL. TOP PLATE
SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS.
1
2" RESILIENT CHANNEL
2X4PLATE WD. DBL. TOP PLATE 2X6 WD. DBL. TOP
UNIT SIDE
UNIT SIDE
CORRIDOR SIDE
3" SA BATTS
*MIN STC 50
UNIT SIDE
91
4"
SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS.
2X4 WD. BOTTOM PLATE
2X4 WD. STUDS AT 16" O.C.
3 1/2" SOUND ATTENUATION BLANKETS
FRICTION-FITTED TO COMPLETELY FILL THE
STUD CAVITIES
(1) LAYER 7/16" OSB. SEE STRUCTURAL
SHEETS FOR LOCATION AND NAILING
PATTERN
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
2X4 WD. DBL. TOP PLATE
UL DESIGNATION: U341
1-HOUR FIRE PARTITION (IBC 708)
"FURRED" WALL
3" SA BATTS
UNITSIDE SIDE CORRIDOR SIDE UNIT SIDE UNIT
"W2A" - INDICATES 2X6 FRAMING
ACOUSTICAL SEALANT AT PERIMETER EACH SIDE
ACOUSTICALSIDE SEALANT AT ACOUSTICAL SEALANT AT PERIMETER EACH
PERIMETER EACH SIDE
RATED SEALANT AT PERIMETER
EACH SIDE
3/MAT4" GYP-CRETE OVER ACOUSTIC MAT 3/4" GYP-CRETE OVER ACOUSTIC
3/MAT4" GYP-CRETE OVER ACOUSTIC MAT 3/MAT4" GYP-CRETE OVER ACOUSTIC 3/4" GYP-CRETE OVER ACOUSTIC
6"
UL DESIGNATION: U301
2-HOUR FIRE BARRIER (IBC 707)
2X4 WD. BOTTOM PLATE
2X4 WD. DBL. TOP PLATE
2X4 WD. STUDS 16" 0.C.
FIRESTOPPED
(2) LAYERS 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
1'-4" 1'-4"
3/4" GYP-CRETE OVER ACOUSTIC MAT
FIRE RATINGS FOR CONCRETE MASONRY UNITS
(*) INDICATES FIRE RATING USING EQUIVALENT THICKNESS METHOD
UNIT
WIDTH
(NOM)
BLOCK TYPE
FACE
SHELL
%
SOLID
EQUIVALENT
THICKNESS
FIRE RATINGS - HOURS
NORMAL WEIGHT
CONCRETE
(Siliceous Gravel)
MEDIUM WEIGHT
(105-125 lb. per cubic
ft. blended)
LIGHT WEIGHT
(Under 105 lbs. per cubic ft.)
(Expanded clay, shale or slate)
4
4
6
6
6
8
8
8
8
8
10
12
12
3 CORE REGULAR
SOLID
2 CORE REGULAR
3 CORE 75% SOLID
SOLID
2 CORE REGULAR
2 CORE 58% SOLID
2 CORE 62% SOLID
3 CORE 75% SOLID
SOLID
2 CORE REGULAR
2 CORE REGULAR
2 CORE 56% SOLID
1.0"
SOLID
SOLID
SOLID
1.06"
2.0"
1.25"
1.5"
1.5"
2.25"
1.25"
1.5"
2.125"
76%
100%
56%
75%
100%
100%
53%
58%
62%
75%
51%
50%
50%
2.7
3.6
3.1
4.2
5.6
4.0
4.4
4.7
5.7
7.6
4.9
5.8
6.5
3/4 *
1-1/2*
1*
3*
1-1/2
1*
1-1/2*
1*
3-3/4*
2 - UL U905
2 - UL U905
1*
1-1/2*
1*
4*
2 - UL U905
2 - UL U905
3 - UL U904
4 - UL U901
4 - UL U901
3 - UL U904
15
8"
2'-0"
1" STEEL 'Z' FURRING STRIP
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' ONE SIDE
"FURRED" WALL
3/4" GYP-CRETE OVER ACOUSTIC MAT
W1 W2 W3
W7
W4 W5 W6
2 - UL U905
2 - UL U905
2 - UL U905
3 - UL U904 3 - UL U904
4 - UL U901 4 - UL U901
2 - UL U905 2 - UL U905
3 - UL U904 3 - UL U904 4 - UL U901
4 - UL U901 4U901 - UL U901 4 - UL
2 - UL U906 2 - UL U906 2 - UL U906
75
8"
NOMINAL 8" CMU WALL. SEE STRUCTURAL
DWGS FOR GROUT & REINFORCING.
SEE "FIRE RATING FOR CONCRETE MANSONRY
UNITS" TABLE FOR FIRE RATING INFO.
M1
"M1A" - 1 1/2 HR. FIRE RATED
"M1B" - 2 HR. FIRE RATED
"M1C" - 3 HR. FIRE RATED
"M1D" - 4 HR. FIRE RATED
1'-01
4"
UNIT SIDE
UNIT SIDE
SEE STRUCTURAL DWGS.
UL DESIGNATION: U336 CONFIGURATION B
2-HOUR AREA SEPARATION WALL (IBC 706)
2x4 WOOD STUDS AT 16" O.C.
3 1/2" SOUND ATTENUATION BLANKETS
FRICTION-FITTED TO COMPLETELY FILL THE
STUD CAVITIES
(1) LAYER 5/8" GYPSUM WALL BOARD TYPE
'X' EACH SIDE
2x4 WOOD STUDS
UNIT SIDE UNIT SIDE
RATED SEALANT AT PERIMETER EACH SIDE
RATED SEALANT AT PERIMETER EACH SIDE
SPECIFIED BASE
W8
2 CONTINUOUS LAYERS 1"x24" TYPE 'X'
GYPSUM PANELS WITH STEEL H STUDS.
PROVIDE ALUM. CLIPS BETWEEN H STUDS
AND WALL FRAMING
MIN.
3
4" AIR SPACE
USE: CMU / CIP WALL FURRING AT CORRIDOR
NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED
USE: FIRST FLOOR SERVICE ROOMS
"W2B" - OMIT INSULATION
USE: FURRED WALL AT ELEVATORS AND STAIRS
NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED
USE: TYPICAL INTERIOR UNIT WALL
"x" INDICATES 1 HR RATING
NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED
USE: TYPICAL INTERIOR UNIT WALL WITH PLUMBING
"x" INDICATES 1 HR RATING
NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED
USE: TYPICAL CORRIDOR WALL
"p" INDICATES WALL HAS PLUMBING "t" INDICATES "TALL" WALL
- CHANGE TO 2 X 6 FRAMING AND ALIGN INTERIOR SHEATHING
NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED
USE: UNIT DEMISING WALL
"p" INDICATES WALL HAS PLUMBING "t" INDICATES "TALL" WALL
- CHANGE TO 2 X 6 FRAMING AND ALIGN INTERIOR SHEATHING
"t" INDICATES TALL WALL. USE 2x6 STUDS. ALIGN EXTERIOR AND
INTERIOR WALL FINISHES.
NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED
USE: RATED SERVICE ROOM
NOTE: FIRST FLOOR TO BE FIRE-RETARDENT TREATED
USE: FIRE RATED AREA SEPARATION WALL
"p" INDICATES WALL HAS PLUMBING "t" INDICATES "TALL" WALL
- CHANGE TO 2 X 6 FRAMING AND ALIGN INTERIOR SHEATHING
"t" INDICATES TALL WALL. USE 2x6 STUDS. ALIGN EXTERIOR AND
INTERIOR WALL FINISHES.
NOTE: FIRST FLOOR TO BE FIRE-RETARDANT TREATED
1" RIGID INSULATION
SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTIONARCHITECT MANAGER
17104
DECEMBER 8, 2017
ISSUED FOR CONSTRUCTION
MIDTOWN WEST
CARMEL, IN
CLIENT
# DESCRIPTION DATE
BARRETT AND
STOKELY, INC
INDIANAPOLIS, IN
D I L L O N
CONSTRUCTION
G R O U P
A022
04/25/18
Nick Mishler