HomeMy WebLinkAboutA031SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTION MANAGER ARCHITECT
17104
DECEMBER 8, 2017
ISSUED FOR CONSTRUCTION
MIDTOWN WEST
CARMEL, IN
CLIENT
# DESCRIPTION DATE
BARRETT AND
STOKELY, INC
INDIANAPOLIS, IN
D I L L O N
CONSTRUCTION
G R O U P
A031
EXTERIOR WALL
ASSEMBLIES
SCALE:
EXTERIOR WALL TYPE
EW1
SCALE: 1 1/2" = 1'-0"
EXTERIOR WALL TYPE
EW2
SCALE: 1 1/2" = 1'-0"
EXTERIOR WALL TYPE
EW4
SCALE: 1 1/2" = 1'-0"
EXTERIOR WALL TYPE
EW5
1 1/2" = 1'-0"
SCALE:
FLOOR ASSEMBLY
F1
SCALE: 1 1/2" = 1'-0"
FLOOR ASSEMBLY
F2
1 1/2" = 1'-0"
SCALE:
ROOF ASSEMBLY
R1
1 1/2" = 1'-0"
TYPICAL BRICK VENEER WALL
-WOOD CONSTRUCTION
TYPICAL CEMENT BOARD WALL
-BETWEEN WINDOWS AS SHOWN ON ELEVATIONS
-AS PANEL WITH JOINT TRIM AT 4TH & 5TH LEVELS AND AT
INTERIOR COURTYARDS
1'-01
7 8"
1
1'-1 8"
5
8"
TYPICAL BRICK VENEER WALL
-PROVIDE AT RETAIL AND LEASEING AREAS. BRICK VENEER
AT METAL STUD CONSTRUCTION: PODIUM LEVEL
1'-11
4"
TYPICAL BRICK VENEER WALL
-CMU CONSTRUCTION: SERVICE ROOMS
USE:
-PODIUM @ COURTYARD: 2ND FLOOR SLAB
AT GARAGE NOT OVER HOUSING
USE:
-TYPICAL FLOORS: 3, 4, & 5
ROOFING MEMBRANE ON
1/4" PROTECTION BOARD
R20 POLYISOCYANURATE ROOF
INSULATION IN 2 LAYERS W/
STAGGERED JOINTS
OPEN WEB ROOF TRUSSES
*VARIES* - SEE STRUCTURAL DWGS.
5
8" GWBX
ROOF SHEATHING
FINISH AS SCHEDULED
3/8" "Acousti-Mat" product ENKASONIC
or equal.
18" OPEN WEB JOISTS,
SEE STRUCTURAL DWGS.
1
2" RESILIENT CHANNEL
5
8" GWBX
3
4" T&G SHEATHING
1-1/8" CEMENTITIOUS UNDERLAYMENT
1'-97
8"
12" CAST-IN-PLACE PT SLAB
SCALE:
EXTERIOR WALL TYPE
EW3
1 1/2" = 1'-0"
TYPICAL CEMENT BOARD WALL BELOW PODIUM
-BETWEEN WINDOWS AS SHOWN ON ELEVATIONS
-SIDE AND BACK WALLS OF RECESSED BALCONIES
-AS PANEL WITH JOINT TRIM FIRST LEVEL
813
16"
5/8" GYPSUM WALL
BOARD TYPE X
R-21 HD BATT INSULATION
2X6 WOOD STUDS @ 16" O.C.
4" FACE BRICK
7/16" SHEATHING
BRICK TIE SIMILAR TO HOHMANN
& BARNARD X-SEAL ANCHOR
(ALLOWS FOR VERTICAL
DIFFERENTIAL MOVEMENT
BETWEEN STUDS AND MASONRY;
INSTALL @ 16" O.C. VERT. AND
32" O.C. HRZ.
5/8" GYPSUM WALL
BOARD TYPE X
R-21 HD BATT INSULATION
2X6 WOOD STUDS @ 16" O.C.
5/8" GYPSUM WALL
BOARD TYPE X
R-21 HD BATT INSULATION
6" STEEL STUDS
5/8" GYPSUM WALL
BOARD TYPE X
6", 18 GA. STEEL STUD
SEE STRUCTURAL DWGS
FOR ADDITIONAL INFO.
4" FACE BRICK
BRICK TIE SIMILAR TO HOHMANN
& BARNARD X-SEAL ANCHOR
(ALLOWS FOR VERTICAL
DIFFERENTIAL MOVEMENT
BETWEEN STUDS AND MASONRY;
INSTALL @ 16" O.C. VERT. AND
32" O.C. HRZ.
BRICK TIE SIMILAR TO HOHMANN
& BARNARD 165 LOX-ALL TRUSS
STYLE ADJUSTABLE JOINT
REINFORCEMENT @ 16" O.C.
4" FACE BRICK
8" MASONRY WALL.
SEE STRUCTURAL
DRAWINGS FOR
REINFORCING
FLUID APPLIED AIR
& VAPOR BARRIER
1" RIGID CAVITY
WALL INSULATION
SOUND ATTENUATION BATTS
SCALE:
ROOF ASSEMBLY
R2
1 1/2" = 1'-0"
ROOFING MEMBRANE ON
1/4" PROTECTION BOARD
3
4" T&G ROOFING
JOIST (REF. STRUCTURAL)
R-38 CELLULOSE ROOF INSULATION
12
6
5/8" GWBX
1
9
16
"
SCALE:
FLOOR ASSEMBLY
F3
1 1/2" = 1'-0"
USE:
-PODIUM @ HOUSING: 2ND FLOOR SLAB
12" CAST-IN-PLACE PT SLAB
LIGHTWEIGHT SLOPING TOPPING FROM
4" FEATHERED TO 0" AT DRAINS
SPECIFIED FINISH
5
8" EXTERIOR GRADE GWB
R-21 HD BATT INSULATION
SCALE:
EXTERIOR WALL TYPE
EW6
1 1/2" = 1'-0"
TYPICAL BRICK VENEER WALL
-WOOD CONSTRUCTION
-LOFT EXTERIOR WALLS
1'-17
8"
5/8" GYPSUM WALL
BOARD TYPE X
R-21 HD BATT INSULATION
2X8 WOOD STUDS @ 16" O.C.
4" FACE BRICK
BRICK TIE SIMILAR TO HOHMANN
& BARNARD X-SEAL ANCHOR
(ALLOWS FOR VERTICAL
DIFFERENTIAL MOVEMENT
BETWEEN STUDS AND MASONRY;
INSTALL @ 16" O.C. VERT. AND
32" O.C. HRZ.
SCALE:
EXTERIOR WALL TYPE
EW7
1 1/2" = 1'-0"
TYPICAL CEMENT BOARD WALL
-BETWEEN WINDOWS AS SHOWN ON ELEVATIONS
-AS PANEL WITH JOINT TRIM AT 4TH & 5TH LEVELS AND AT
INTERIOR COURTYARDS
-LOFT EXTERIOR WALLS
87
8"
5/8" GYPSUM WALL
BOARD TYPE X
R-21 HD BATT INSULATION
2X8 WOOD STUDS @ 16" O.C.
SCALE:
EXTERIOR WALL TYPE
EW8
1 1/2" = 1'-0"
AT ELECTRICAL METERS ENCLOSURE
5/8" GYPSUM WALL
BOARD TYPE X
R-21 HD BATT INSULATION
2X6 WOOD STUDS @ 16" O.C.
5/16" VERTICAL SIDING
71
8"
SCALE:
EXTERIOR WALL TYPE
EW9 - EW10
1 1/2" = 1'-0"
AT FIRE SEPARATION IN BALCONIES
SCALE:
EXTERIOR WALL TYPE
EW11
1 1/2" = 1'-0"
AT FIRE SEPARATION IN BALCONIES
UL DESIGNATION: U336 CONFIGURATION B
2-HOUR AREA SEPARATION WALL (IBC 706)
1'-07
8"
2x4 WOOD STUDS AT 16" O.C.
R-13 THERMAL BATT INSULATION
FRICTION-FITTED TO COMPLETELY FILL
THE STUD CAVITIES
(1) LAYER 5/8" GYPSUM WALL BOARD
TYPE 'X'
2 CONTINUOUS LAYERS 1"x24" TYPE 'X'
GYPSUM PANELS WITH STEEL H STUDS.
PROVIDE ALUM. CLIPS BETWEEN H
STUDS AND WALL FRAMING
MIN.
3
4" AIR SPACE
UNIT SIDE EXTERIOR
1'-55
8"
2x4 WOOD STUDS AT 16" O.C.
R-13 THERMAL BATT INSULATION
FRICTION-FITTED TO COMPLETELY FILL THE
STUD CAVITIES
(1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X'
UNIT SIDE EXTERIOR
2 CONTINUOUS LAYERS 1"x24" TYPE 'X'
GYPSUM PANELS WITH STEEL H STUDS.
PROVIDE ALUM. CLIPS BETWEEN H STUDS AND
WALL FRAMING
MIN.
3
4" AIR SPACE
UL DESIGNATION: U336 CONFIGURATION B
2-HOUR AREA SEPARATION WALL (IBC 706)
4" FACE BRICK
BRICK TIE SIMILAR TO HOHMANN & BARNARD
X-SEAL ANCHOR (ALLOWS FOR VERTICAL
DIFFERENTIAL MOVEMENT BETWEEN STUDS AND
MASONRY; INSTALL @ 16" O.C. VERT. AND
32" O.C. HRZ.
1
2" RESILIENT CHANNEL
"TYVEK" COMMERCIAL
BUILDING WRAP - OR "EQUAL"
7/16" SHEATHING
"TAMLYN" DRAINABLE
HOUSE WRAP OVER
"TYVEK" COMMERCIAL
WRAP - OR "EQUAL"
5
8" EXTERIOR GRADE GWB
1" RIGID CAVITY
WALL INSULATION
1" RIGID CAVITY
WALL INSULATION
7/16" SHEATHING
"TYVEK" COMMERCIAL
BUILDING WRAP - OR "EQUAL"
7/16" CEMENTITIOUS
PANEL SIDING SYSTEM
7/16" CEMENTITIOUS
PANEL SIDING SYSTEM
7/SHEATHING16" SHEATHING 7/16"
7/16" CEMENTITIOUS
PANEL SIDING SYSTEM
"TAMLYN" DRAINABLE
HOUSE WRAP OVER
"TYVEK" COMMERCIAL
WRAP - OR "EQUAL"
"TAMLYN" DRAINABLE
HOUSE WRAP OVER
"TYVEK" COMMERCIAL
WRAP - OR "EQUAL"
"TAMLYN" DRAINABLE
HOUSE WRAP OVER
"TYVEK" COMMERCIAL
WRAP - OR "EQUAL"
"TAMLYN" DRAINABLE
HOUSE WRAP OVER
"TYVEK" COMMERCIAL
WRAP - OR "EQUAL"
7/16" SHEATHING
7/16" SHEATHING
"TYVEK" COMMERCIAL
BUILDING WRAP - OR "EQUAL"
7/16" CEMENTITIOUS
PANEL SIDING SYSTEM
1 ASI-002 02.05.2018
1 1 1 1
1 1 1 1 1
04/25/18
Nick Mishler