Loading...
HomeMy WebLinkAboutA031SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTION MANAGER ARCHITECT 17104 DECEMBER 8, 2017 ISSUED FOR CONSTRUCTION MIDTOWN WEST CARMEL, IN CLIENT # DESCRIPTION DATE BARRETT AND STOKELY, INC INDIANAPOLIS, IN D I L L O N CONSTRUCTION G R O U P A031 EXTERIOR WALL ASSEMBLIES SCALE: EXTERIOR WALL TYPE EW1 SCALE: 1 1/2" = 1'-0" EXTERIOR WALL TYPE EW2 SCALE: 1 1/2" = 1'-0" EXTERIOR WALL TYPE EW4 SCALE: 1 1/2" = 1'-0" EXTERIOR WALL TYPE EW5 1 1/2" = 1'-0" SCALE: FLOOR ASSEMBLY F1 SCALE: 1 1/2" = 1'-0" FLOOR ASSEMBLY F2 1 1/2" = 1'-0" SCALE: ROOF ASSEMBLY R1 1 1/2" = 1'-0" TYPICAL BRICK VENEER WALL -WOOD CONSTRUCTION TYPICAL CEMENT BOARD WALL -BETWEEN WINDOWS AS SHOWN ON ELEVATIONS -AS PANEL WITH JOINT TRIM AT 4TH & 5TH LEVELS AND AT INTERIOR COURTYARDS 1'-01 7 8" 1 1'-1 8" 5 8" TYPICAL BRICK VENEER WALL -PROVIDE AT RETAIL AND LEASEING AREAS. BRICK VENEER AT METAL STUD CONSTRUCTION: PODIUM LEVEL 1'-11 4" TYPICAL BRICK VENEER WALL -CMU CONSTRUCTION: SERVICE ROOMS USE: -PODIUM @ COURTYARD: 2ND FLOOR SLAB AT GARAGE NOT OVER HOUSING USE: -TYPICAL FLOORS: 3, 4, & 5 ROOFING MEMBRANE ON 1/4" PROTECTION BOARD R20 POLYISOCYANURATE ROOF INSULATION IN 2 LAYERS W/ STAGGERED JOINTS OPEN WEB ROOF TRUSSES *VARIES* - SEE STRUCTURAL DWGS. 5 8" GWBX ROOF SHEATHING FINISH AS SCHEDULED 3/8" "Acousti-Mat" product ENKASONIC or equal. 18" OPEN WEB JOISTS, SEE STRUCTURAL DWGS. 1 2" RESILIENT CHANNEL 5 8" GWBX 3 4" T&G SHEATHING 1-1/8" CEMENTITIOUS UNDERLAYMENT 1'-97 8" 12" CAST-IN-PLACE PT SLAB SCALE: EXTERIOR WALL TYPE EW3 1 1/2" = 1'-0" TYPICAL CEMENT BOARD WALL BELOW PODIUM -BETWEEN WINDOWS AS SHOWN ON ELEVATIONS -SIDE AND BACK WALLS OF RECESSED BALCONIES -AS PANEL WITH JOINT TRIM FIRST LEVEL 813 16" 5/8" GYPSUM WALL BOARD TYPE X R-21 HD BATT INSULATION 2X6 WOOD STUDS @ 16" O.C. 4" FACE BRICK 7/16" SHEATHING BRICK TIE SIMILAR TO HOHMANN & BARNARD X-SEAL ANCHOR (ALLOWS FOR VERTICAL DIFFERENTIAL MOVEMENT BETWEEN STUDS AND MASONRY; INSTALL @ 16" O.C. VERT. AND 32" O.C. HRZ. 5/8" GYPSUM WALL BOARD TYPE X R-21 HD BATT INSULATION 2X6 WOOD STUDS @ 16" O.C. 5/8" GYPSUM WALL BOARD TYPE X R-21 HD BATT INSULATION 6" STEEL STUDS 5/8" GYPSUM WALL BOARD TYPE X 6", 18 GA. STEEL STUD SEE STRUCTURAL DWGS FOR ADDITIONAL INFO. 4" FACE BRICK BRICK TIE SIMILAR TO HOHMANN & BARNARD X-SEAL ANCHOR (ALLOWS FOR VERTICAL DIFFERENTIAL MOVEMENT BETWEEN STUDS AND MASONRY; INSTALL @ 16" O.C. VERT. AND 32" O.C. HRZ. BRICK TIE SIMILAR TO HOHMANN & BARNARD 165 LOX-ALL TRUSS STYLE ADJUSTABLE JOINT REINFORCEMENT @ 16" O.C. 4" FACE BRICK 8" MASONRY WALL. SEE STRUCTURAL DRAWINGS FOR REINFORCING FLUID APPLIED AIR & VAPOR BARRIER 1" RIGID CAVITY WALL INSULATION SOUND ATTENUATION BATTS SCALE: ROOF ASSEMBLY R2 1 1/2" = 1'-0" ROOFING MEMBRANE ON 1/4" PROTECTION BOARD 3 4" T&G ROOFING JOIST (REF. STRUCTURAL) R-38 CELLULOSE ROOF INSULATION 12 6 5/8" GWBX 1 9 16 " SCALE: FLOOR ASSEMBLY F3 1 1/2" = 1'-0" USE: -PODIUM @ HOUSING: 2ND FLOOR SLAB 12" CAST-IN-PLACE PT SLAB LIGHTWEIGHT SLOPING TOPPING FROM 4" FEATHERED TO 0" AT DRAINS SPECIFIED FINISH 5 8" EXTERIOR GRADE GWB R-21 HD BATT INSULATION SCALE: EXTERIOR WALL TYPE EW6 1 1/2" = 1'-0" TYPICAL BRICK VENEER WALL -WOOD CONSTRUCTION -LOFT EXTERIOR WALLS 1'-17 8" 5/8" GYPSUM WALL BOARD TYPE X R-21 HD BATT INSULATION 2X8 WOOD STUDS @ 16" O.C. 4" FACE BRICK BRICK TIE SIMILAR TO HOHMANN & BARNARD X-SEAL ANCHOR (ALLOWS FOR VERTICAL DIFFERENTIAL MOVEMENT BETWEEN STUDS AND MASONRY; INSTALL @ 16" O.C. VERT. AND 32" O.C. HRZ. SCALE: EXTERIOR WALL TYPE EW7 1 1/2" = 1'-0" TYPICAL CEMENT BOARD WALL -BETWEEN WINDOWS AS SHOWN ON ELEVATIONS -AS PANEL WITH JOINT TRIM AT 4TH & 5TH LEVELS AND AT INTERIOR COURTYARDS -LOFT EXTERIOR WALLS 87 8" 5/8" GYPSUM WALL BOARD TYPE X R-21 HD BATT INSULATION 2X8 WOOD STUDS @ 16" O.C. SCALE: EXTERIOR WALL TYPE EW8 1 1/2" = 1'-0" AT ELECTRICAL METERS ENCLOSURE 5/8" GYPSUM WALL BOARD TYPE X R-21 HD BATT INSULATION 2X6 WOOD STUDS @ 16" O.C. 5/16" VERTICAL SIDING 71 8" SCALE: EXTERIOR WALL TYPE EW9 - EW10 1 1/2" = 1'-0" AT FIRE SEPARATION IN BALCONIES SCALE: EXTERIOR WALL TYPE EW11 1 1/2" = 1'-0" AT FIRE SEPARATION IN BALCONIES UL DESIGNATION: U336 CONFIGURATION B 2-HOUR AREA SEPARATION WALL (IBC 706) 1'-07 8" 2x4 WOOD STUDS AT 16" O.C. R-13 THERMAL BATT INSULATION FRICTION-FITTED TO COMPLETELY FILL THE STUD CAVITIES (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' 2 CONTINUOUS LAYERS 1"x24" TYPE 'X' GYPSUM PANELS WITH STEEL H STUDS. PROVIDE ALUM. CLIPS BETWEEN H STUDS AND WALL FRAMING MIN. 3 4" AIR SPACE UNIT SIDE EXTERIOR 1'-55 8" 2x4 WOOD STUDS AT 16" O.C. R-13 THERMAL BATT INSULATION FRICTION-FITTED TO COMPLETELY FILL THE STUD CAVITIES (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' UNIT SIDE EXTERIOR 2 CONTINUOUS LAYERS 1"x24" TYPE 'X' GYPSUM PANELS WITH STEEL H STUDS. PROVIDE ALUM. CLIPS BETWEEN H STUDS AND WALL FRAMING MIN. 3 4" AIR SPACE UL DESIGNATION: U336 CONFIGURATION B 2-HOUR AREA SEPARATION WALL (IBC 706) 4" FACE BRICK BRICK TIE SIMILAR TO HOHMANN & BARNARD X-SEAL ANCHOR (ALLOWS FOR VERTICAL DIFFERENTIAL MOVEMENT BETWEEN STUDS AND MASONRY; INSTALL @ 16" O.C. VERT. AND 32" O.C. HRZ. 1 2" RESILIENT CHANNEL "TYVEK" COMMERCIAL BUILDING WRAP - OR "EQUAL" 7/16" SHEATHING "TAMLYN" DRAINABLE HOUSE WRAP OVER "TYVEK" COMMERCIAL WRAP - OR "EQUAL" 5 8" EXTERIOR GRADE GWB 1" RIGID CAVITY WALL INSULATION 1" RIGID CAVITY WALL INSULATION 7/16" SHEATHING "TYVEK" COMMERCIAL BUILDING WRAP - OR "EQUAL" 7/16" CEMENTITIOUS PANEL SIDING SYSTEM 7/16" CEMENTITIOUS PANEL SIDING SYSTEM 7/SHEATHING16" SHEATHING 7/16" 7/16" CEMENTITIOUS PANEL SIDING SYSTEM "TAMLYN" DRAINABLE HOUSE WRAP OVER "TYVEK" COMMERCIAL WRAP - OR "EQUAL" "TAMLYN" DRAINABLE HOUSE WRAP OVER "TYVEK" COMMERCIAL WRAP - OR "EQUAL" "TAMLYN" DRAINABLE HOUSE WRAP OVER "TYVEK" COMMERCIAL WRAP - OR "EQUAL" "TAMLYN" DRAINABLE HOUSE WRAP OVER "TYVEK" COMMERCIAL WRAP - OR "EQUAL" 7/16" SHEATHING 7/16" SHEATHING "TYVEK" COMMERCIAL BUILDING WRAP - OR "EQUAL" 7/16" CEMENTITIOUS PANEL SIDING SYSTEM 1 ASI-002 02.05.2018 1 1 1 1 1 1 1 1 1 04/25/18 Nick Mishler