Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A355
SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTION MANAGER ARCHITECT 17104 DECEMBER 8, 2017 ISSUED FOR CONSTRUCTION MIDTOWN WEST CARMEL, IN CLIENT # DESCRIPTION DATE BARRETT AND STOKELY, INC INDIANAPOLIS, IN D I L L O N CONSTRUCTION G R O U P A355 SECTION DETAILS 2'-0" 3 EQ. RISERS IN 1'-9" 1 2" MAX. ISOLATION JOINT 1 1 2" O.D. PAINTED MTL. HANDRAIL 2'-10" 2'-10" 1 2" MAX. ISOLATION JOINT SEALANT REF. STRUCTURAL DWGS. FOR POUR IN PLACE CONCRETE STAIRS SCALE: 01 SECTION DETAIL 3/4" = 1'-0" 14 A381 MAINTAIN MFR'S RECOMMENDED DISTANCE BETWEEN F.F. / GRADE AND B.O. FIBER CEMENT PANEL STARTER PANEL TRIM AT BOTTOM SCALE: 02 SECTION DETAIL 3/4" = 1'-0" SCALE: 03 SECTION DETAIL 3/4" = 1'-0" SCALE: 04 SECTION DETAIL 3/4" = 1'-0" SCALE: 05 SECTION DETAIL 3/4" = 1'-0" SCALE: 06 SECTION DETAIL 3/4" = 1'-0" SCALE: 07 SECTION DETAIL 3/4" = 1'-0" SCALE: 08 SECTION DETAIL 3/4" = 1'-0" SCALE: 09 SECTION DETAIL 3/4" = 1'-0" 10 A382 03 A383 03 A383 SIM. 04 A383 EXPOSED FACE OF BRICK VENEER TO BE SET BACK 1 4" FROM THE VERT. FACE OF STONE WINDOW SILL 01 A385 14 A381 GRADE - SEE CIVIL DWGS. MAINTAIN MFR'S REQUIRED DISTANCE BETWEEN GRADE AND FIBER CEMENT PANELS STARTING FLASHING AND TRIM PER MFR'S RECOMMENDATIONS 42" MIN. 03 14 A385 A381 14 A381 07 A381 03 A383 10 A382 04 A383 03 A383 SIM. EXPOSED FACE OF BRICK VENEER TO BE SET BACK 1 4" FROM THE VERT. FACE OF STONE WINDOW SILL 02 A385 07 A381 MAINTAIN MFR'S REQUIRED DISTANCE BETWEEN SLAB AND HARDIE PANELS STARTING FLASHING AND TRIM PER MFR'S RECOMMENDATIONS ISOLATION JOINT MATERIAL CONT. SEALANT REF. STRUCTURAL DWGS FOR SLAB INFO SLOPE 03 A385 11 A383 SIM. 1'-41 4" 06 A385 10 A383 43 4" 2'-4" 42" 61 4" VARIES 04 A385 SIM 42" 14 A381 PEDESTRIAN TRAFFIC GRADE TOP COAT 07 A381 14 A381 07 A381 FIBER CEMENT BOARD SOFFIT PANEL WITH SOFFIT VENTS AND INSECT SCREENS IN VENTS BALCONY STRUCTURE PER STRUCTURAL DWGS. 05 A385 08 A385 03 A383 11 A385 09 A385 10 A385 07 A385 FIBER CEMENT BOARD SOFFIT PANEL WITH SOFFIT VENTS AND INSECT SCREENS IN VENTS 10 A383 PEDESTRIAN TRAFFIC GRADE TOP COAT SLOPE SCALE: 10 SECTION DETAIL 3/4" = 1'-0" SCALE: 11 SECTION DETAIL 3/4" = 1'-0" SCALE: 12 SECTION DETAIL 3/4" = 1'-0" SCALE: 13 SECTION DETAIL 3/4" = 1'-0" 2'-4" 2'-4" 2'-4" 2'-4" 2'-4" 2'-4" 2'-4" 2'-4" 2'-4" 2'-4" 4" 04 A383 03 A383 SCALE: 14 SECTION DETAIL 3/4" = 1'-0" 2'-4" 12 A383 SCALE: 15 SECTION DETAIL 3/4" = 1'-0" SCALE: 16 SECTION DETAIL 3/4" = 1'-0" SCALE: 17 SECTION DETAIL 3/4" = 1'-0" SCALE: 18 SECTION DETAIL 3/4" = 1'-0" 04 A383 2'-0" 10 A382 11 A382 MAINTAIN MFR'S REQUIRED DISTANCE BETWEEN SLAB AND HARDIE PANELS STARTING FLASHING AND TRIM PER MFR'S RECOMMENDATIONS ISOLATION JOINT MATERIAL CONT. SEALANT REF. STRUCTURAL DWGS FOR SLAB INFO 2'-0" 12 A382 01 A384 02 A384 04 A384 03 A384 05 A384 SEE STRUCTURAL DWGS. FOR TRUSS INFO FIBER CEMENT BOARD SOFFIT PANEL WITH SOFFIT VENTS AND INSECT SCREENS IN VENTS; INSTALL ON 2x4 WOOD FRAMING @ 24" O.C. 1'-71 2" 1'-71 2" SLOPE SLOPE 42" MIN. PAINTED MTL. RAIL AND PICKETS RAILING SYSTEM PAINTED MTL. RAIL AND PICKETS RAILING SYSTEM PAINTED MTL. RAIL AND PICKETS RAILING SYSTEM PAINTED MTL. RAIL AND PICKET RAILING SYSTEM WATERPROOF MEMBRANE ON WALLS AND BOTTOM OF PLANTER ROOFING MEMBRANE ON 4" OF RIGID INSULATION ON 3 4" PLWD. DECK ON WOOD JOISTS, REF. STRUCTURAL DWGS FOR JOIST INFO. SCALE: 19 SECTION DETAIL 3/4" = 1'-0" SCALE: 20 SECTION DETAIL 3/4" = 1'-0" SCALE: 21 SECTION DETAIL 3/4" = 1'-0" 10 A382 06 A384 03 A384 08 A384 05 A384 12 A382 07 A384 12 9 63 (4) @ 12" O.C. 4" 4" 4" DOUBLE SOLDIER COURSE, ALIGN TOP WITH FINISH FLOOR 1 2" 4" 4" 4" 5" 4" 5" 1 ASI-001 01.10.2018 1 1 1 2 ASI-002 02.05.2018 2 2 2 2 2 04/25/18 Nick Mishler