HomeMy WebLinkAboutA382SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTION MANAGER ARCHITECT
17104
DECEMBER 8, 2017
ISSUED FOR CONSTRUCTION
MIDTOWN WEST
CARMEL, IN
CLIENT
# DESCRIPTION DATE
BARRETT AND
STOKELY, INC
INDIANAPOLIS, IN
D I L L O N
CONSTRUCTION
G R O U P
A382
DOOR, LOUVER
AND ENLARGED
DETAILS
SCALE:
01 LOUVER HEAD
DETAIL AT
3" = 1'-0"
SCALE:
02 DETAIL AT BALCONY
CONSTRUCTION
3" = 1'-0"
SCALE:
03 SLIDING DOOR SILL
DETAIL AT
3" = 1'-0"
SCALE:
04 SLIDING DOOR HEAD
DETAIL AT
3" = 1'-0"
SCALE:
05 SLIDING DOOR SILL
DETAIL AT
3" = 1'-0"
SCALE:
06 ROOF
DETAIL AT
3" = 1'-0"
SCALE:
07 LOUVER SILL
DETAIL AT
3" = 1'-0"
SCALE:
08 PANEL JOINT
DETAIL AT
3" = 1'-0"
SCALE:
09 PANEL JOINT
DETAIL AT
3" = 1'-0"
KICK-OUT FLASHING
ALIGN BOTTOM OF
PANEL WITH FLOOR LINE
ZIP SYSTEM FLASHING
OVER VERT. LEG OF
KICK-OUT FLASHING
1
2" MAX.
FLASHING TAPE W/
VENT STRIP OVER VERT.
LEG OF KICK-OUT
FLASHING
1
2" MAX.
KICK-OUT FLASHING
SEE STRUCTURAL DWGS.
FOR BEAM INFO
FIBER CEMENT PANEL
SYSTEM ON
7
16" SHEATHING
TERMINATE PANEL WITH 'J'
MOULDING
BRAKE METAL FLASHING -
FULL DEPTH OF WALL AND
MIN. 1" DOWN FACE OF
HARDIE PANEL BOTH
SIDES; MAT. AND FINISH TO
MATCH LOUVER
SEALANT AND BACKER
ROD BOTH SIDES
6"
SHIM BY LOUVER
INSTALLER
SLIDING DOOR ASSEMBLY
SHIM BY DOOR INSTALLER
SEALANT AND BACKER
ROD BOTH SIDES
FLASHING TAPE W/ VENT
STRIP OVER VERT. LEG
OF KICK-OUT FLASHING
'J' MOULDING AT PANEL
TOP EDGE
RETURN GWB AT DOOR
HEAD
CONT. SEALANT AND
BACKER ROD
ALIGN EXT. FACE OF
DOOR WITH EXT. FACE OF
SHEATHING
FIRE TREATED 2x8
WOOD BLOCKING, CUT
TO SIZE
SEE STRUCTURAL DWGS.
FOR HEAD INFO
CHAMFER ALL EDGES OF
CIP BALCONY
TRAFFIC TOP COAT TO
EXTEND DOWN FACE OF
CONCRETE AND TO DRIP
EDGE
3
8" FIBER CEMENT SOFFIT
ATTACHED TO Z-CHANNEL
2"
MTL. FLASHING TO EXTEND
UNDER DOOR THRESHOLD
SETSEALANT THRESHOLD ON A CONT.
FULL BED OF SEALANT
2"
PREFINISHED MTL. GRAVEL
STOP
EXTEND ROOFING
MEMBRANE DOWN FACE OF
ZIP BOARD MIN. 6 INCHES
CONT. ROOF FLASHING
MEMBRANE ON GRAVEL
STOP
5/4x6 FIBER CEMENT TRIM
BOARD ON
7
16" SHEATHING
'J' MOULDING AT PANEL
TOP EDGE
MTL. FLASHING TO EXTEND
UNDER DOOR THRESHOLD
SETSEALANT THRESHOLD ON A CONT.
FULL BED OF SEALANT
2"
2x6 BOARD AS
CEMENTITIOUS
UNDERLAYMENT STOP
CONT. SEALANT
ISOLATION JOINT
SCHEDULED DOOR
SCHEDULED DOOR
SCALE:
10 GRADE
DETAIL AT
3" = 1'-0"
SCALE:
11 WINDOW SILL
DETAIL AT
3" = 1'-0"
SCALE:
12 WINDOW HEAD
DETAIL AT
3" = 1'-0"
SCALE:
13 WATER TABLE
DETAIL AT
3" = 1'-0"
SCALE:
14 CAST STONE TRIM
DETAIL AT
3" = 1'-0"
GRADE, SEE CIVIL
DWGS.
GROUT SOLID BEHIND
BRICK / CMU
CONCRETE CORED 6"
CMU
THRU-WALL FLASHING
WITH METAL DRIP EDGE.
EXTEND UP FACE OF
FOUNDATION WALL MIN.
12 INCHES
CELL VENTS / WEEPS @
24" O.C. HRZ.
MORTAR NET
5/4x6 FIBER CEMENT
TRIM BOARD ON
3
8"
FIBER CEMENT BACKER
BOARD OVER
7
16"
SHEATHING
CONT. SEALANT AND
BACKER ROD
SHIM BY WINDOW
INSTALLER
WINDOW AS SCHEDULED
KICK-OUT FLASHING,
EXTEND VERT. LEG UP
FACE OF SHEATHING
MIN. 5 INCHES
TERMINATE PANEL WITH
'J' MOULDING
DOUBLE PLATE AT SILL
CONT. SEALANT
PAINTED 1x WOOD SILL
1"
CONT. SEALANT
FIBEREX WINDOW AS
SCHEDULED
SHIM BY WINDOW
INSTALLER
CONT. SEALANT AND
BACKER ROD
CONT. SEALANT
RETURN GWB AT HEAD
5/4x6 FIBER CEMENT
TRIM BOARD ON
3
8"
FIBER CEMENT BACKER
BOARD ON WRB
KICK-OUT FLASHING
3/4" PT PLYWOOD
WITH SHEET
MEMBRANE
WATERPROOFING
EXTEND SHEET
MEMBRANE
WATERPROOFING UP
FACE OF SHEATHING
AND UNDER THRESHOLD
BALCONY FRAMING,
SEE STRUCTURAL
1" 5
1
2"
1"
35
8"
1
2"
1
2"
25
8"
TERMINATE PANEL WITH
'J' MOULDING
CAST STONE TRIM WITH
INTEGRAL DRIP EDGE,
ALIGN WITH ADJACENT
WINDOW SILL
KICK OUT FLASHING
CELL VENT / WEEPS @
24" O.C. HRZ.
61
2"
1
2"
5"
1
2"
1
2"
4"
1
2"
1"
CAST STONE TRIM WITH
INTEGRAL DRIP EDGE,
ALIGN WITH ADJACENT
WINDOW SILL
SCALE:
15 PARAPET
DETAIL AT
3" = 1'-0"
SCALE:
16 DOOR SILL
DETAIL AT
3" = 1'-0"
SCALE:
17 DOOR HEAD
DETAIL AT
3" = 1'-0"
SCALE:
18 DOOR SILL
DETAIL AT
3" = 1'-0"
PREFINISHED MTL. COPING
EXTEND ROOFING
MEMBRANE FLASHING UNDER
MTL. COPING AND DOWN
FACE OF SHEATHING MIN. 6
INCHES
PAINTED 5/4x8 FIBER
CEMENT TRIM BOARD
41
8"
FIBER CEMENT PANEL
SYSTEM, TERMINATE WITH 'J'
MOULDING
5"
1
4 2"
1
2"
1" 5"
1
2"
LOW PROFILE
THRESHOLD, SET ON A
FULL BED OF SEALANT
CAST STONE SILL WITH
INTEGRAL DRIP EDGE
1"
CAST STONE TRIM WITH
INTEGRAL DRIP EDGE
CELL VENT
CELL VENT @ 48" O.C.
HRZ.
RAILING SUPPORT
SYSTEM ATTACHED TO
STRUCTURAL WALL.
SEAL ALL
PENETRATIONS
THROUGH VENEER
LOW PROFILE
THRESHOLD, SET ON A
FULL BED OF SEALANT
CONT. SEALANT AND
BACKER ROD
CAST STONE SILL WITH
INTEGRAL DRIP EDGE
CONT. SEALANT AND
BACKER ROD
2"
1
1 4"
3
4"
7"
13
8"
1
2"
RAILING SUPPORT
SYSTEM ATTACHED TO
STRUCTURAL WALL.
SEAL ALL
PENETRATIONS
THROUGH VENEER
CELL VENTS @ 48" O.C.
HRZ.
4"x4"x
1
4" STL. ANGLE
ATTACHED TO
STRUCTURAL WALL
ISOLATION JOINT
(1) SOLDIER COURSE AT
HEAD
MORTAR NET
CELL VENTS / WEEPS @
24" O.C. HRZ.
THRU-WALL FLASH WITH
METAL DRIP EDGE.
EXTEND UP FACE OF
SHEATHING MIN. 12
INCHES
STEEL LINTEL, SEE
STRUCTURAL DWGS.
SEALANT AND BACKER
ROD
CONT. SEALANT AND
BACKER ROD BOTH SIDES
SHIM BY LOUVER
INSTALLER
HARDIE PLANK
SCALE:
19 ROOF AND WALL
DETAIL AT
3" = 1'-0"
KICK-OUT FLASHING,
EXTEND VERT. LEG UP
FACE OF SHEATHING
MIN. 12 INCHES
MAINTAIN MFR'S RECOMMENDED
DISTANCE BETWEEN ROOF AND
BOTTOM OF PANEL
EXTEND ROOFING MEMBRANE UP
FACE OF SHEATHING MIN. 18
INCHES
FLASHING TAPE W/
VENT STRIP OVER VERT.
LEG OF KICK-OUT
FLASHING
FLASHING TAPE W/
VENT STRIP OVER VERT.
LEG OF KICK-OUT
FLASHING
KICK-OUT FLASHING
2" RIGID INSULATION B/T
Z-CHANNEL
METAL EDGE TRIM W/ DRIP EDGE
TAPER INSULATION AWAY FROM
BUILDING
1
1 ASI-002 02.05.2018
04/25/18
Nick Mishler