Loading...
HomeMy WebLinkAboutA385SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTION MANAGER ARCHITECT 17104 DECEMBER 8, 2017 ISSUED FOR CONSTRUCTION MIDTOWN WEST CARMEL, IN CLIENT # DESCRIPTION DATE BARRETT AND STOKELY, INC INDIANAPOLIS, IN D I L L O N CONSTRUCTION G R O U P SCALE: 01 BRICK DETAIL 3" = 1'-0" SCALE: 02 DETAIL TRANSITION BRICK - SIDING 3" = 1'-0" SCALE: 03 BALCONY DRAIN DETAIL 3" = 1'-0" SCALE: 04 BALCONY DETAIL 3" = 1'-0" SCALE: 05 NOT USED 3" = 1'-0" SCALE: 06 BALCONY DRAIN DETAIL 3" = 1'-0" SCALE: 07 BALCONY DETAIL 3" = 1'-0" SCALE: 08 SILL AT BAY WINDOW 3" = 1'-0" SCALE: 09 HEAD AT BAY WINDOW SCALE: 3" = 1'-0" 10 SILL AT BAY WINDOW 3" = 1'-0" SCALE: 11 ROOF / HEAD AT BAY WINDOW 3" = 1'-0" 91 4" 6" 1" 1 2" 1 2" CELL VENTS / WEEPS @ 24" O.C. HRZ. THRU-WALL FLASHING WITH METAL DRIP EDGE. EXTEND UP FACE OF SHEATHING 12 INCHES MIN. STEEL SHELF ANGLE ATTACHED TO BUILDING STRUCTURE; EXTEND BETWEEN PILASTERS MORTAR NET 5FRAMING 2x WOOD 1 8" EXTEND ROOFING MEMBRANE UNDER SHELF ANGLE AND UP FACE OF SHEATHING MIN. 12 INCHES 3 4" PLYWOOD SHEATHING ROOFING MEMBRANE ON MIN. 2" RIGID INS. 3 4" PLYWOOD DECK ON 2x4 WD. FRAMING @ 16" O.C. REF. STRUCTURAL DWGS. FOR BEAM INFO. 1'-61 2" MIN. R-25 BATT INSULATION 5 8" TYPE 'X' GWB CEILING RIM BOARD - SEE STRUCTURAL DWGS. 71 4" CONT. SEALANT AND BACKER ROD WINDOW ASSEMBLY SYSTEM 4/4x_ FIBER CEMENT TRIM BOARD ON 3 8" FIBER CEMENT BACKER BOARD SEALANT AND BACKER BOARD MTL. KICK-OUT FLASHING, VERT. LEG TO EXTEND MIN. 6" BEHIND HARDIE PANEL PREFINISHED MTL. GRAVEL STOP FIBER CEMENT REVEAL ON 7 16" SHEATHING ROOFING MEMBRANE FLASHING ON GRAVEL STOP 3 4" PLYWOOD ON 2x6 WOOD FRAMING @ 16" O.C. 2'-73 4" STEEL SHELF ANGLE ATTACHED TO BUILDING STRUCTURE 7" 1 2" 1 2" CELL VENTS / WEEPS @ 24" O.C. HRZ. THRU-WALL FLASHING WITH METAL DRIP EDGE. EXTEND UP FACE OF SHEATHING 12 INCHES MIN. MORTAR NET RIM BOARD - SEE STRUCTURAL DWGS. (2) SOLDIER COURSES FIBER CEMENT PANEL SYSTEM ON 7 16" SHEATHING- PROVIDE 'J' MTL. END TRIMS AT SIDING ALIGN TOP OF SOLDIER COURSE WITH FINISH FLOOR 7" 1 2" 1 2" ALIGN TOP OF SOLDIER COURSE WITH FINISH FLOOR (2) SOLDIER COURSES 1" 71 4" CELL VENTS @ 48" O.C. HRZ. REF. STRUCTURAL DWGS. FOR SLAB @ BALCONY 3" STEEL LINTEL ANGLE, SEE STRUCTURAL CELL VENTS / WEEPS @ 24" O.C. HRZ. THRU-WALL FLASHING WITH METAL DRIP EDGE. EXTEND UP FACE OF SHEATHING 12 INCHES MIN. MORTAR NET CONT. SEALANT AND BACKER ROD HARDIE PANEL SOFFIT KICK-OUT MTL. FLASHING HARDIE VERT. SIDING ON ZIP SYSTEM ON 2x6 WOOD FRAME REF. STRUCTURAL DWGS. FOR HEADER INFO (1) SOLDIER COURSE, CUT BRICK AS NECESSARY TO ALLOW FOR CONCRETE ON BALCONY 1" FINISH FLOOR SEE WALL SECTIONS 71 4" 71 4" STL. LINTEL ANGLE CELL VENTS @ 24" O.C. MAX HRZ. SCUPPER BOX LIP MIN. 1 INCH BRICK VENEER ON 7 16" ZIP SYSTEM HARDIE REVEAL ON ZIP SYSTEM ON 2x6 WOOD FRAME ROOFING MEMBRANE FLASHING OVER SCUPPER BOX 23 8" 2" 1" ROOFING MEMBRANE ON RIGID INSULATION; EXTEND UP FACE OF SHEATHING MIN. 18 INCHES 1 2" KICK-OUT METAL FLASHING AND STARTING PANEL TRIM. MTL. KICK-OUT FLASHING WINDOW ASSEMBLY SYSTEM 4/4x_ FIBER CEMENT TRIM BOARD ON 3 8" FIBER CEMENT BACKER BOARD CONT. SEALANT AND BACKER ROD RETURN 5 8" GWB AT HEAD REF. STRUCTURAL DWGS. FOR HEADER INFO 5/4x_ FIBER CEMENT TRIM BOARD ON 3 8" FIBER CEMENT BACKER BOARD CONT. SEALANT AND BACKER ROD WINDOW ASSEMBLY SYSTEM 1x PAINTED WOOD STOOL CONT. SEALANT CONT. SEALANT 'J' MOULDING AT HARDIE PANEL ENDS 5/4x_ FIBER CEMENT TRIM BOARD ON 3 8" FIBER CEMENT BACKER BOARD CONT. SEALANT AND BACKER ROD WINDOW ASSEMBLY SYSTEM 1x PAINTED WOOD SILL CONT. SEALANT CONT. SEALANT 'J' MOULDING AT FIBER CEMENT PANEL ENDS MTL. KICK-OUT FLASHING, VERT. LEG TO EXTEND MIN. 6" BEHIND HARDIE BACKER BOARD FIBER CEMENT PANEL SYSTEM ON 7 16" SHEATHING 2" MIN. RIGID INSULATION 2x4 WOOD BLOCKING 1'-37 8" VENTED HARDIE SOFFIT PANEL, PROVIDE INSECT SCREENS AT VENTS 2X4 WOOD BLOCKING CELL VENTS @ 48" O.C. HRZ. A385 ENLARGED DETAILS 8" 6" 1" 1 2" 1 2" ALIGN TOP OF BRICK ACCENT WITH FINISH FLOOR (1) SOLDIER COURSE SCALE: 12 BRICK ACCENT DETAIL 3" = 1'-0" THRU-WALL FLASHING W/METAL DRIP EDGE REMOVE TOP SOLDIER COURSE AS NECESSARY TO INSTALL SCUPPER CELL VENTS @ 48" O.C. MAX HRZ. MORTAR NET KICK OUT FLASHING (1) SOLDIER COURSE 1" CONT. SEALANT AND BACKER ROD 1 2" 1 2" 1 ASI-001 01.10.2018 1 11 4 2" 1 8" 42" MIN. 1 COURSE BRICK RETURN BEYOND 1 2 ASI-002 02.05.2018 2 2 2 2 1 2 04/25/18 Nick Mishler