HomeMy WebLinkAboutA385SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTION MANAGER ARCHITECT
17104
DECEMBER 8, 2017
ISSUED FOR CONSTRUCTION
MIDTOWN WEST
CARMEL, IN
CLIENT
# DESCRIPTION DATE
BARRETT AND
STOKELY, INC
INDIANAPOLIS, IN
D I L L O N
CONSTRUCTION
G R O U P
SCALE:
01 BRICK DETAIL
3" = 1'-0"
SCALE:
02 DETAIL TRANSITION
BRICK - SIDING
3" = 1'-0"
SCALE:
03 BALCONY DRAIN DETAIL
3" = 1'-0"
SCALE:
04 BALCONY DETAIL
3" = 1'-0"
SCALE:
05 NOT USED
3" = 1'-0"
SCALE:
06 BALCONY DRAIN DETAIL
3" = 1'-0"
SCALE:
07 BALCONY DETAIL
3" = 1'-0"
SCALE:
08 SILL AT BAY WINDOW
3" = 1'-0"
SCALE:
09 HEAD AT BAY WINDOW
SCALE: 3" = 1'-0"
10 SILL AT BAY WINDOW
3" = 1'-0"
SCALE:
11 ROOF / HEAD AT BAY WINDOW
3" = 1'-0"
91
4"
6"
1"
1
2"
1
2" CELL VENTS / WEEPS @ 24" O.C. HRZ.
THRU-WALL FLASHING WITH METAL DRIP
EDGE. EXTEND UP FACE OF SHEATHING
12 INCHES MIN.
STEEL SHELF ANGLE ATTACHED TO
BUILDING STRUCTURE; EXTEND BETWEEN
PILASTERS
MORTAR NET
5FRAMING 2x WOOD
1
8"
EXTEND ROOFING MEMBRANE UNDER
SHELF ANGLE AND UP FACE OF
SHEATHING MIN. 12 INCHES
3
4" PLYWOOD SHEATHING
ROOFING MEMBRANE
ON MIN. 2" RIGID INS.
3
4" PLYWOOD DECK ON 2x4 WD.
FRAMING @ 16" O.C.
REF. STRUCTURAL DWGS. FOR BEAM INFO.
1'-61
2"
MIN. R-25 BATT INSULATION
5
8" TYPE 'X' GWB CEILING
RIM BOARD - SEE STRUCTURAL DWGS.
71
4"
CONT. SEALANT AND BACKER ROD
WINDOW ASSEMBLY SYSTEM
4/4x_ FIBER CEMENT TRIM BOARD
ON
3
8" FIBER CEMENT BACKER
BOARD
SEALANT AND BACKER BOARD
MTL. KICK-OUT FLASHING, VERT.
LEG TO EXTEND MIN. 6" BEHIND
HARDIE PANEL
PREFINISHED MTL. GRAVEL STOP
FIBER CEMENT REVEAL ON
7
16"
SHEATHING
ROOFING MEMBRANE FLASHING ON
GRAVEL STOP
3
4" PLYWOOD ON 2x6 WOOD
FRAMING @ 16" O.C.
2'-73
4"
STEEL SHELF ANGLE ATTACHED TO
BUILDING STRUCTURE
7"
1
2"
1
2"
CELL VENTS / WEEPS @ 24" O.C. HRZ.
THRU-WALL FLASHING WITH METAL DRIP
EDGE. EXTEND UP FACE OF SHEATHING
12 INCHES MIN.
MORTAR NET
RIM BOARD - SEE STRUCTURAL DWGS.
(2) SOLDIER COURSES
FIBER CEMENT PANEL SYSTEM ON
7
16"
SHEATHING- PROVIDE 'J' MTL. END
TRIMS AT SIDING
ALIGN TOP OF SOLDIER COURSE WITH
FINISH FLOOR
7"
1
2"
1
2"
ALIGN TOP OF SOLDIER COURSE WITH
FINISH FLOOR
(2) SOLDIER COURSES
1"
71
4"
CELL VENTS @ 48" O.C. HRZ.
REF. STRUCTURAL DWGS. FOR SLAB @
BALCONY
3"
STEEL LINTEL ANGLE, SEE STRUCTURAL
CELL VENTS / WEEPS @ 24" O.C. HRZ.
THRU-WALL FLASHING WITH METAL DRIP
EDGE. EXTEND UP FACE OF SHEATHING
12 INCHES MIN.
MORTAR NET
CONT. SEALANT AND BACKER ROD
HARDIE PANEL SOFFIT
KICK-OUT MTL. FLASHING
HARDIE VERT. SIDING
ON ZIP SYSTEM ON 2x6
WOOD FRAME
REF. STRUCTURAL
DWGS. FOR HEADER
INFO
(1) SOLDIER COURSE, CUT BRICK AS
NECESSARY TO ALLOW FOR CONCRETE
ON BALCONY
1"
FINISH FLOOR
SEE WALL SECTIONS
71
4"
71
4"
STL. LINTEL
ANGLE
CELL VENTS @ 24" O.C.
MAX HRZ.
SCUPPER BOX
LIP MIN. 1 INCH
BRICK VENEER ON
7
16"
ZIP SYSTEM
HARDIE REVEAL ON ZIP
SYSTEM ON 2x6 WOOD
FRAME
ROOFING MEMBRANE
FLASHING OVER
SCUPPER BOX
23
8"
2"
1"
ROOFING MEMBRANE ON
RIGID INSULATION;
EXTEND UP FACE OF
SHEATHING MIN. 18
INCHES
1
2"
KICK-OUT METAL
FLASHING AND STARTING
PANEL TRIM.
MTL. KICK-OUT FLASHING
WINDOW ASSEMBLY
SYSTEM
4/4x_ FIBER CEMENT
TRIM BOARD ON
3
8"
FIBER CEMENT BACKER
BOARD
CONT. SEALANT AND
BACKER ROD
RETURN
5
8" GWB AT
HEAD
REF. STRUCTURAL DWGS.
FOR HEADER INFO
5/4x_ FIBER CEMENT
TRIM BOARD ON
3
8"
FIBER CEMENT BACKER
BOARD
CONT. SEALANT AND
BACKER ROD
WINDOW ASSEMBLY
SYSTEM
1x PAINTED
WOOD STOOL
CONT. SEALANT
CONT. SEALANT
'J' MOULDING AT HARDIE
PANEL ENDS
5/4x_ FIBER CEMENT TRIM
BOARD ON
3
8" FIBER CEMENT
BACKER BOARD
CONT. SEALANT AND BACKER
ROD
WINDOW ASSEMBLY SYSTEM
1x PAINTED WOOD SILL
CONT. SEALANT
CONT. SEALANT
'J' MOULDING AT FIBER
CEMENT PANEL ENDS
MTL. KICK-OUT FLASHING, VERT.
LEG TO EXTEND MIN. 6" BEHIND
HARDIE BACKER BOARD
FIBER CEMENT PANEL
SYSTEM ON
7
16"
SHEATHING
2" MIN. RIGID INSULATION
2x4 WOOD BLOCKING
1'-37
8"
VENTED HARDIE SOFFIT PANEL,
PROVIDE INSECT SCREENS AT
VENTS
2X4 WOOD BLOCKING
CELL VENTS @ 48" O.C. HRZ.
A385
ENLARGED
DETAILS
8"
6"
1"
1
2"
1
2"
ALIGN TOP OF BRICK ACCENT
WITH FINISH FLOOR
(1) SOLDIER COURSE
SCALE:
12 BRICK ACCENT DETAIL
3" = 1'-0"
THRU-WALL FLASHING
W/METAL DRIP EDGE
REMOVE TOP SOLDIER
COURSE AS NECESSARY
TO INSTALL SCUPPER
CELL VENTS @ 48" O.C.
MAX HRZ.
MORTAR NET
KICK OUT FLASHING
(1) SOLDIER COURSE
1"
CONT. SEALANT AND BACKER ROD
1
2"
1
2"
1 ASI-001 01.10.2018
1
11
4 2"
1
8"
42" MIN.
1 COURSE BRICK RETURN BEYOND
1
2 ASI-002 02.05.2018
2 2
2
2
1
2
04/25/18
Nick Mishler