HomeMy WebLinkAboutA407SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTION MANAGER ARCHITECT
17104
DECEMBER 8, 2017
ISSUED FOR CONSTRUCTION
MIDTOWN WEST
CARMEL, IN
CLIENT
# DESCRIPTION DATE
BARRETT AND
STOKELY, INC
INDIANAPOLIS, IN
D I L L O N
CONSTRUCTION
G R O U P
A407
UNIT PLAN
UNIT A2a
SCALE:
FLOOR PLAN
UNIT A2a
1/4" = 1'-0"
UNIT A2a - DATA
UNIT SQUARE FOOTAGE
BALCONY
TOTAL SQUARE FOOTAGE
874 S.F.
87 S.F.
961 S.F.
LEGEND
INDICATES INTERIOR ELEVATION
INDICATES DOOR TYPE
INDICATES WINDOW TYPE
3
2
A
SYMBOL
TOTAL NUMBER OF UNITS 4
INDICATES LENGTH OF REINFORCING 48"
1. CONTRACTOR TO PROVIDE REQUIRED BLOCKING FOR CABINETS AND
BATH ACCESSORIES
2. ALL BEDROOM CLOSETS TO HAVE DOUBLE SHELF AND ROD
CONFIGURATION.
3. ALL COAT CLOSETS TO HAVE SINGLE SHELF AND ROD CONFIGURATION.
4. SEE MECHANICAL DRAWINGS FOR DRYER VENT INSTALLATION
LOCATION
5. SEE MECHANICAL DRAWINGS FOR IN-WALL WATER CONNECTIONS
6. CONTRACTOR TO VERIFY SIZE AND FRAMING DIMENSIONS OF HVAC
UNIT, BATHTUB DOORS AND WINDOWS.
7. PROVIDE 1x2 PTD WOOD TRIM @ INTERIOR OF ALL CLOSETS / UTILITY
CLOSETS WHERE STANDARD DOOR CASING WILL NOT FIT.
8. UNDERCUT ALL INTERIOR DOORS FOR RETURN AIR 1".
9. WRAP ALL EXPOSED PIPES WHEN ADAPTED FOR HANDICAP USE.
10. ALL DRYWALL WET AREAS TO BE "GREEN" BOARD.
11. BASE OF MIRROR INSTALLED 40" AFF MAXIMUM.
12. PROVIDE DOOR VIEWER AT UNIT ENTRY DOORS
13. PROVIDE ELECTRICAL OUTLET IN ISLAND SIDEWALL 6" BELOW
COUNTERTOP AT CENTERLINE OF WALL. SEE ELECTRICAL DRAWINGS
14. ALL CEILING HEIGHTS (CLG HT) ARE 9'-0" IN UNITS U.N.O.
15. ALL FLOORING TRANSITIONS ARE TO BE CENTERED UNDER THE DOOR
16. REFER TO OVERALL PLANS FOR DEMISING / CORRIDOR WALL
REQUIREMENTS. ALL WALLS / WALL SECTIONS BEHIND PLUMBING
FIXTURES TO BE 2X6 MINIMUM. - FINISH WALLS TO ALIGN.
17. INTERIOR ELEVATIONS ARE FOR SCHEMATIC CABINET LAYOUT ONLY.
CONTRACTOR TO VERIFY ALL DIMENSIONS, PROVIDE FILLERS AS
REQUIRED. REFER TO CABINET SHOP DRAWINGS AND OWNER
SPECIFICATIONS.
UNIT PLAN NOTES GENERAL NOTES
1. THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE
JOBSITE. NOTIFY ARCHITECT OF ANY DEVIATIONS FROM THOSE
CONDITIONS AS THEY ARE NOTED ON THE DRAWINGS.
2. 0'-0" CORRELATES TO 831'-6" ON CIVIL DRAWINGS (RETAIL FFEL)
3. THE GENERAL CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL
WORK WITH THE OWNER.
4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH
ALL STATE AND LOCAL BUILDING CODES AND GOVERNMENTAL
REGULATORY AGENCIES.
5. THE GENERAL CONTRACTOR IS TO SUBMIT SHOP DRAWINGS - PROJECT
DATA AND SAMPLES TO OWNER / ARCHITECT FOR APPROVAL PRIOR
TO FABRICATION OF ALL MILLWORK AND WALL FINISHES.
6. DO NOT SCALE ANY DRAWINGS. ANY DIMENSIONS ARE TO BE
OBTAINED FROM THE ARCHITECT IF NOT NOTED ON THE DRAWINGS.
REFER ALL QUESTIONS TO THE ARCHITECT OR E.O.R.
7. ALL WALL DIMENSION ARE TO C.L. OF FRAMING or FACE OF FRAMING
8. THE GENERAL CONTRACTOR SHALL KEEP ONE SET OF PLANS AT THE
JOBSITE FOR THE SPECIFIC PURPOSE OF RECORDING ACTUAL
CONSTRUCTION CONDITIONS. SUCH PROJECT RECORD-DOCUMENTS
SHALL BE PROVIDED TO THE OWNER UPON COMPLETION OF THE
PROJECT.
9. THE GENERAL CONTRACTOR SHALL VERIFY SIZE, LOCATION, AND
CHARACTERISTICS OF ALL WORK AND EQUIPMENT SUPPLIED BY THE
OWNER OR OTHERS WITH THE MANUFACTURER OR SUPPLIER PRIOR TO
THE START OF WORK.
10. THE GENERAL CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS
RECEIVE COMPLETE WORKING DRAWINGS AND ASSUME FULL
RESPONSIBILITY FOR COORDINATION OF WORK.
11. DOOR NUMBERS CORRESPOND TO ROOM NUMBERS.
12. REFER TO ELEVATIONS FOR WINDOW LOCATIONS. WINDOWS MAY VARY
IN LOCATION FROM INDIVIDUAL UNIT PLANS DUE TO CHANGING
ELEVATION CONDITIONS.
U1
U2
U3
U4
U5
U6
UNIT ACCESSORY NOTES
1. MOUNTING HEIGHTS NOTED ARE TO BE USED ONLY WHEN
MANUFACTURER'S STANDARD MOUNTING HEIGHTS ARE NOT PROVIDED.
ALL ACCESSORIES IN H.C. BATHROOM TO COMPLY WITH
MANUFACTURER'S RECOMMENDED BARRIER FREE MOUNTING HEIGHTS.
2. ALL UNIT ACCESSORIES TO BE MOUNTED INTO DRYWALL WITH
MANUFACTURER'S SPECIFIED ANCHORS.
ALL BATHROOM FIXTURES TO BE SATING NICKEL OR OIL RUBBED
BRONZE.
SHOWER ROD(CURTAINS BY OTHERS)
SURFACE MOUNTED TOILET TISSUE HOLDER
24" TOWEL BAR
ROBE HOOK - INTERIOR SIDE OF DOOR
FRAMED MIRROR - CENTER ON SINK
TOWEL RING
BATHROOM
C.T.
CLOSET
CARPET
LIVING RM
VINYL PLANK
BEDROOM
CARPET
UTILITIES
KITCHEN
VINYL PLANK
BALCONY
POWDER
ROOM
C.T.
U2
U1
48"
30"
U5
U3
U2
U5
U6
DRY
36"
11'-71
4"
13'-6" 4'-8"
30'-10"
6'-31
2" 5'-9
3
8" 2'-0
3
4" 3'-4
3
8" 5'-11
3
4" 5'-7
1
8"
3'-7"
32'-8"
5'-51
2"
1'-0"
4'-27
8" 2'-0
3
8" 8
3
4" 6'-1
1
2"
6'-3
1
2" 4'-9
1
2"
117
8"
3'-5
1
2" 3'-7
3
4" 23'-7
3
4"
30'-9"
10'-43
8" 22'-3
1
2"
32'-8"
W6x
W3x
W4x
W4
W3
W4
W4
FINISHED CABINET
BACK PANEL
W4
W3
W3
W4
UNIT SHELVING LEGEND
(1) WOOD SHELF AND (1) WOOD ROD
(5) WOOD SHELVES 10" DEEP
(1) WIRE SHELF 18" DEEP ABOVE WASHER AND DRYER
(5) WIRE SHELVES (PANTRY)
(2) FLOATING SHELVES
1
3
2
4
5
#
UNIT DOOR SCHEDULE
TYPE
CORRIDOR UNIT ENTRY
SIZE COUNT
3'-0" X 7'-0"
3'-PANTRY0" X 6'-8" BEDROOM / BATHROOM / CLOSET /
2'-6" X 6'-8"
2'-10" X 6'-8"
BATHROOM / CLOSET / PANTRY
1
2
3
4
5 BARN DOOR
6 3'-0" X 6'-8" BALCONY UNIT ENTRY
(2) 2'-6" X 6'-8" SLIDING CLOSET DOORS
2'-6" X 5'-6" UTILITY CLOSET IN UNIT
7
8
9 2'-6" X 5'-6" UTILITY CLOSET OUTSIDE UNIT
10
11
(2) 3'-0" X 8'-0" BALCONY UNIT DOORS A1f
12
(2) 1'-6" X 6'-8" DOUBLE CLOSET
13
(2) 3'-0" X 6'-8" DOUBLE BALCONY DOORS
2'-0" X 6'-8" CLOSET / PANTRY
(2) 2'-0" X 6'-8" DOUBLE BEDROOM/CLOSET DOORS
14
15
3'-6" X 6'-8"
4'-0" X 6'-8"
CASED OPENING
CASED OPENING
16 4'-0" X 1'-8" BORROWED LIGHT W/
1
4" GLAZ. & PNT. TRIM
1
3
1
1
1
11
11
1
9
2
6
2
2
3
9'-83
8"
SCALE:
01 INTERIOR ELEVATION
KITCHEN
1/2" = 1'-0" SCALE:
02 INTERIOR ELEVATION
KITCHEN
1/2" = 1'-0" SCALE:
03 INTERIOR ELEVATION
KITCHEN
1/2" = 1'-0" SCALE:
05 INTERIOR ELEVATION
BATHROOM
1/2" = 1'-0"
SCALE:
06 INTERIOR ELEVATION
BATHROOM
1/2" = 1'-0" SCALE:
07 INTERIOR ELEVATION
POWDER ROOM
1/2" = 1'-0"
RANGE
HOOD
DW
2
3'-0" 2'-6" 3'-6"
7'-0"
1'-0" 2'-0" 3'-0" 1'-0"
11'-43
4"
2'-6" 2'-6" 2'-6"
43
4"
3'-0" 5"
9'-0"
1'-3" 3'-2" 1'-0"
3'-0" 1'-9" 1'-3" 2'-0"
3'-0" 1'-6" 3'-6" 1'-0"
6'-0" 2'-0"
11'-4"
1'-6" 1'-6" 5'-0" 3'-0"
2'-10" 4"
2"
3'-6" 2'-2"
6'-0"
1'-0" 5'-0"
1'-101
4"
3'-0"
2'-10"
2'-10" 4"
2"
6'-9"
4'-0" 1'-3" 1'-6"
1'-101
4"
PROVIDE BLOCKING FOR FUTURE
INSTALLATION OF GRAB BARS.
REFER AX FOR TYPICAL
INSTALLATION DIAGRAMS
REFER FINISH MATRIX FOR
SPECIFIC TILE SELECTION
PROVIDE BLOCKING FOR
FUTURE INSTALLATION OF
GRAB BARS. REFER AX
FOR TYPICAL INSTALLATION
DIAGRAMS
PROVIDE BLOCKING FOR
FUTURE INSTALLATION OF
GRAB BARS. REFER AX
FOR TYPICAL INSTALLATION
DIAGRAMS
30"
42"
36"
FINISHED CABINET
SIDE PANELS
3'-0"
4'-0"
3'-0"
1
2
3
5
6
MW
W2B
1
1 1
2'-03
8" 11'-5
5
8"
1"
1'-0"
CROWN MOLDING SHOWN
BY DASHED LINE TYP.
4
SCALE:
04 INTERIOR ELEVATION
LAUNDRY ROOM
1/2" = 1'-0"
WOOD SHELVES 10"
DEEP TYP
1X CLEAT
WOOD SHELF 18" DEEP
MW
3'-1"
1'-6" 1'-6" 1'-6" 1'-6" 3'-0"
2'-4"
CROWN PER PLAN
14'-21
4"
4
3
4" 3'-5
3
4"
1'-0"
WASH
1'-6"
ALIGN
REFER TO OVERALL PLANS AND EXTERIOR
ELEVATIONS FOR SPECIFIC EXTERIOR
CONDITIONS OF EACH UNIT. THE NUMBER
AND LOCATION OF WINDOWS CHANGE ON
MOST ELEVATIONS.
1 ASI-001 01.10.2018
1
1
1
2 ASI-004 03.16.2018
6" 1'-2" 1'-10" 2'-2"
12X24 CERAMIC TILE
INSTALLED IN RUNNING BOND
VERTICAL
2X4 GLASS ACCENT TILE
INSTALLED IN RUNNING BOND
3'-2"
6" 1'-1
3
4" 10
1
4"
1'-0"
2 2 2 2
2 2
2'-4" 2'-8"
U4
3'-2"
3'-0" 6" 2'-0" 1'-7
3
4"
3'-4" 1'-10" 4" 4" 1'-10" 8"
9" 10" 1'-10" 3'-4"
1'-03
4"
2'-2"
PROVIDE AND
INSTALL 60" X 30"
BATH TUB
2
2
2X10 STAINED #2 PINE
SHELVES ON 1/2" DIA. BLACK
PIPE SHELF BRACKET
1'-3"
1"
3'-0"
1"
2'-6" 2'-6" 2'-0" 1'-6" 1'-6" 2'-4" 4"
3"
04/25/18
Nick Mishler