HomeMy WebLinkAboutA433SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CONSTRUCTION MANAGER ARCHITECT
17104
DECEMBER 8, 2017
ISSUED FOR CONSTRUCTION
MIDTOWN WEST
CARMEL, IN
CLIENT
# DESCRIPTION DATE
BARRETT AND
STOKELY, INC
INDIANAPOLIS, IN
D I L L O N
CONSTRUCTION
G R O U P
A433
CLUBHOUSE &
FITNESS CENTER
RCP
SCALE:
01 CEILING PLAN
ENLARGED REFLECTED
3/16" = 1'-0"
TRUE
NORTH
CLUBHOUSE
CH01
1'-6"
RCP LEGEND
LF-12: 2' X 4' LED FIXTURE
10'-0"
LF-11: 2' X 2' LED FIXTURE
LF-13: LED LIGHT COVE FIXTURE
LF-14: 6" CAN LIGHT OR PUCK LIGHT
LF-15: LINEAR WALL WASH FIXTURE
LF-9: DOUBLE DECORATIVE SCONCE
LF-7: LARGE DECORATIVE PENDANT
CEILING ELEVATION ABOVE FINISHED FLOOR
CL-3: 2 X 2 LAY-IN CEILING
CL-1: WOODWORKS SLATTED CEILING
WIRE-HUNG GYPSUM BOARD CEILING
B.O.S. CEILING TO BE AT BOTTOM OF STRUCTURE
GYPSUM BOARD EXPANSION JOINT IN CEILING.
EJ
CL-2: FAUX-TIN CEILING
LF-10: LINEAR DECORATIVE PENDANT
LF-8: DECORATIVE PENDANT
FITNESS
CENTER
F01
B.O.S.
B.O.S.
B.O.S.
B.O.S.
9'-0"
B.O.S.
9'-0"
B.O.S.
10'-0"
9'-8"
B.O.S.
9'-0"
9'-0" 9'-0"
B.O.S.
B.O.S.
9'-0"
9'-8"
10'-0" 9'-0" 9'-0" 9'-0"
9'-8"
B.O.S.
9'-0"
B.O.S.
EJ EJ
EJ
EJ
EJ
8'-35
8"
1'-6" 14'-1
1
2" 13'-9
1
2" 16'-5
5
16" 23'-5
1
4"
4'-7
5
16" 21'-0
9
16"
1'-6" 13'-9" 1'-6" 21'-0
9
16" 4'-7
5
16"
6'-4"
6 1'-0"
3
1'-0" 4"
6'-4"
63
4"
10'-0 3'-5"
11
16"
1'-0"
GENERAL NOTES
1. THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE
JOBSITE. NOTIFY ARCHITECT OF ANY DEVIATIONS FROM THOSE
CONDITIONS AS THEY ARE NOTED ON THE DRAWINGS.
2. 0'-0" CORRELATES TO 831'-6" ON CIVIL DRAWINGS (RETAIL FFEL)
3. THE GENERAL CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL
WORK WITH THE OWNER.
4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH
ALL STATE AND LOCAL BUILDING CODES AND GOVERNMENTAL
REGULATORY AGENCIES.
5. THE GENERAL CONTRACTOR IS TO SUBMIT SHOP DRAWINGS - PROJECT
DATA AND SAMPLES TO OWNER / ARCHITECT FOR APPROVAL PRIOR
TO FABRICATION OF ALL MILLWORK AND WALL FINISHES.
6. DO NOT SCALE ANY DRAWINGS. ANY DIMENSIONS ARE TO BE
OBTAINED FROM THE ARCHITECT IF NOT NOTED ON THE DRAWINGS.
REFER ALL QUESTIONS TO THE ARCHITECT OR E.O.R.
7. ALL WALL DIMENSION ARE TO C.L. OF FRAMING or FACE OF FRAMING
8. THE GENERAL CONTRACTOR SHALL KEEP ONE SET OF PLANS AT THE
JOBSITE FOR THE SPECIFIC PURPOSE OF RECORDING ACTUAL
CONSTRUCTION CONDITIONS. SUCH PROJECT RECORD-DOCUMENTS
SHALL BE PROVIDED TO THE OWNER UPON COMPLETION OF THE
PROJECT.
9. THE GENERAL CONTRACTOR SHALL VERIFY SIZE, LOCATION, AND
CHARACTERISTICS OF ALL WORK AND EQUIPMENT SUPPLIED BY THE
OWNER OR OTHERS WITH THE MANUFACTURER OR SUPPLIER PRIOR TO
THE START OF WORK.
10. THE GENERAL CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS
RECEIVE COMPLETE WORKING DRAWINGS AND ASSUME FULL
RESPONSIBILITY FOR COORDINATION OF WORK.
11. DOOR NUMBERS CORRESPOND TO ROOM NUMBERS.
12. REFER TO ELEVATIONS FOR WINDOW LOCATIONS. WINDOWS MAY VARY
IN LOCATION FROM INDIVIDUAL UNIT PLANS DUE TO CHANGING
ELEVATION CONDITIONS.
8'-0" 8'-0"
F02
CENTER
F01
CLUBHOUSE
CH02
CLUBHOUSE
CH03
CLUBHOUSE
CH04
B.O.S.
9'-0" 9'-0"
10'-0" 10'-0" 10'-0"
10'-0" 10'-0"
9'-8"
8'-0"
8'-0"
8'-0" 8'-0"
8'-0" 8'-0"
1
1 ASI-002 02.05.2018
04/25/18
Nick Mishler