HomeMy WebLinkAboutE103.0 Panel SchedulesCE N GINEERLANOISSORPEFIAN ADNI I ETREDSGERNo. PE11400027 STATE OF AAME R ON T.YAMAS HI T.......................................................... . ......................................TRUE NORTH DEEM PROJECT NUMBER: DATE: DRAWING TITLE: DRAWING NUMBER: REVISIONS: DRAWN BY: CLIENT PROJECT NUMBER: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. CERTIFICATION:C:\Projects\CAD Files\17040 - St. Vincent - Firestone Bldg\40-Revit (ConDocs)\17040 - StVincent_Firestone_ELEC_17.rvt4/3/2018 12:29:38 PM ASCENSION | ST. VINCENT E604 PANEL SCHEDULES 17040 09.22.2017 PERMIT SETINDIANAPOIS - ST. VINCENT HEALTH ADMINISTRATION OFFICE250 W. 96TH STREET - PARKWOOD BUILDING INDIANAPOLIS, IN 46260B.C.D. 1 2017.10.24 OWNER REVIEW 2 2017.11.15 CONSTRUCTION ISSUE 3 2017.11.28 REVISED CONSTRUCTION ISSUE 14 2018.03.27 REVISED FLOOR PLAN Notes: Total Est. Demand: 61 A Furniture Partitions 1500 VA 100.00% 1500 VA Total Conn.: 61 A Power 7500 VA 100.00% 7500 VA Total Est. Demand: 21.8 kVA Receptacle 9800 VA 100.00% 9800 VA Total Conn. Load: 21.8 kVA Other 3000 VA 100.00% 3000 VA Load Classification Connected Load Demand Factor Demand Load Panel Totals Breaker Accessories (ACC): BL = Breaker Lock / FA = Fire Alarm Circuit Breaker / GF = 30 mA GFCI Circuit Breaker Legend: Total Amps: 57 A 64 A 62 A Total Load: 6.9 7.6 7.4 41 0.5 / 0.4 1 20 A Receptacles - Stat / Flight 42 39 0.5 / 0.2 40 37 Floor Boxes - Transfer Center 20 A 3 0.5 / 0.2 38 35 0.3 / 0.2 3 20 A AVASYS Workstations 36 33 0.3 / 0.2 34 31 AVASYS Workstations 20 A 3 0.3 / 0.2 32 29 0.3 / 0.2 3 20 A AVASYS Workstations 30 27 0.3 / 0.4 1 20 A Monitors on Bulkhead 28 25 AVASYS Workstations 20 A 3 0.3 / 0.4 1 20 A Monitors on Bulkhead 26 23 0.3 / 0.5 1 20 A Furniture - Open Office 24 21 0.3 / 1.0 22 19 AVASYS Workstations 20 A 3 0.3 / 1.8 20 17 0.7 / 0.9 3 100 A Panels 'DP-1', 'DP2', 'DP-4', 'DP-5' 18 15 0.7 / 1.3 1 20 A Receps - 2nd Fl. Meeting 16 13 Furniture Partitions - Call Center 20 A 3 0.7 / 0.7 1 20 A Receptacles - Offices 14 11 0.7 / 1.7 1 20 A Receptacles - Offices 12 9 0.7 / 1.3 1 20 A Receptacles - Training 125 10 7 Furniture Partitions - Call Center 20 A 3 0.7 / 0.4 1 20 A Monitor Receps - Telemetry 8 5 0.3 / 0.4 1 20 A Monitor Receps - Telemetry 6 3 0.3 / 0.2 1 20 A Receptacle - Data Room 4 1 Furniture Partitions - Call Center 20 A 3 0.3 / 0.2 1 20 A Receptacle 2 CKT Circuit Description ACC Trip Poles AΦ (kVA) BΦ (kVA) CΦ (kVA) Poles Trip ACC Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: 225 A Mounting: Recessed Wires: 4 Bus Rating: 225 A Supply From: UPS-1 Phases: 3 Mains Type: MCB Location: DATA ROOM 104 Volts: 120/208 Wye A.I.C. Rating: 22 k Panelboard: PDU-1 Notes: Total Est. Demand: 10 A Total Conn.: 10 A Total Est. Demand: 3.7 kVA Total Conn. Load: 3.7 kVA Receptacle 3680 VA 100.00% 3680 VA Load Classification Connected Load Demand Factor Demand Load Panel Totals Breaker Accessories (ACC): BL = Breaker Lock / FA = Fire Alarm Circuit Breaker / GF = 30 mA GFCI Circuit Breaker Legend: Total Amps: 8 A 15 A 8 A Total Load: 0.9 1.8 1.0 17 18 15 16 13 14 11 12 9 10 7 0.3 / 0.3 8 5 L6-20 Receptacle in Data Room 20 A 2 0.3 / 0.8 6 3 0.3 / 1.5 3 100 A Panel 'DP-2' 4 1 L6-20 Receptacle in Data Room 20 A 2 0.3 / 0.2 1 20 A Receptacle @ Demarc 2 CKT Circuit Description ACC Trip Poles AΦ (kVA) BΦ (kVA) CΦ (kVA) Poles Trip ACC Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: 100 A Mounting: Surface Wires: 4 Bus Rating: 100 A Supply From: PDU-1 Phases: 3 Mains Type: MLO Location: DATA EXP. 132 Volts: 120/208 Wye A.I.C. Rating: 10 kA Panelboard: DP-1 Notes: Total Est. Demand: 7 A Total Conn.: 7 A Total Est. Demand: 2.5 kVA Total Conn. Load: 2.5 kVA Receptacle 2500 VA 100.00% 2500 VA Load Classification Connected Load Demand Factor Demand Load Panel Totals Breaker Accessories (ACC): BL = Breaker Lock / FA = Fire Alarm Circuit Breaker / GF = 30 mA GFCI Circuit Breaker Legend: Total Amps: 13 A 7 A 2 A Total Load: 1.5 0.8 0.3 17 18 15 16 13 14 11 12 9 10 7 8 5 0.0 / 0.3 6 3 0.3 / 0.5 4 1 L6-20 Receptacle in Data Room 20 A 2 0.3 / 1.3 3 100 A Panel 'DP-4' 2 CKT Circuit Description ACC Trip Poles AΦ (kVA) BΦ (kVA) CΦ (kVA) Poles Trip ACC Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: 100 A Mounting: Recessed Wires: 4 Bus Rating: 100 A Supply From: DP-1 Phases: 3 Mains Type: MLO Location: SUPPORT 231 Volts: 120/208 Wye A.I.C. Rating: 10 kA Panelboard: DP-2 Notes: Total Est. Demand: 6 A Total Conn.: 6 A Total Est. Demand: 2.0 kVA Total Conn. Load: 2.0 kVA Receptacle 2000 VA 100.00% 2000 VA Load Classification Connected Load Demand Factor Demand Load Panel Totals Breaker Accessories (ACC): BL = Breaker Lock / FA = Fire Alarm Circuit Breaker / GF = 30 mA GFCI Circuit Breaker Legend: Total Amps: 11 A 4 A 2 A Total Load: 1.3 0.5 0.3 17 18 15 16 13 14 11 12 9 10 7 0.0 / 0.0 8 5 0.3 / 0.0 6 3 Panel 'DP-5' 100 A 3 0.3 / 0.3 4 1 A-V Rack Receptacles 20 A 1 1.0 / 0.3 2 20 A L6-20 Receptacle in Data Room 2 CKT Circuit Description ACC Trip Poles AΦ (kVA) BΦ (kVA) CΦ (kVA) Poles Trip ACC Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: 100 A Mounting: Surface Wires: 4 Bus Rating: 100 A Supply From: DP-2 Phases: 3 Mains Type: MLO Location: DATA 421 Volts: 120/208 Wye A.I.C. Rating: 10 kA Panelboard: DP-4 Notes: Total Est. Demand: 1 A Total Conn.: 1 A Total Est. Demand: 0.5 kVA Total Conn. Load: 0.5 kVA Receptacle 500 VA 100.00% 500 VA Load Classification Connected Load Demand Factor Demand Load Panel Totals Breaker Accessories (ACC): BL = Breaker Lock / FA = Fire Alarm Circuit Breaker / GF = 30 mA GFCI Circuit Breaker Legend: Total Amps: 2 A 2 A 0 A Total Load: 0.3 0.3 0.0 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 0.3 / 0.0 4 1 L6-20 Receptacle in Data Room 20 A 2 0.3 / 0.0 2 CKT Circuit Description ACC Trip Poles AΦ (kVA) BΦ (kVA) CΦ (kVA) Poles Trip ACC Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: 100 A Mounting: Surface Wires: 4 Bus Rating: 100 A Supply From: DP-4 Phases: 3 Mains Type: MLO Location: DATA 540 Volts: 120/208 Wye A.I.C. Rating: 10 kA Panelboard: DP-5 3 3 3 14 14 Notes: Total Est. Demand: 13 A Total Conn.: 12 A Furniture Partitions 1000 VA 100.00% 1000 VA Total Est. Demand: 4.8 kVA Lighting 1440 VA 125.00% 1800 VA Total Conn. Load: 4.4 kVA Power 2000 VA 100.00% 2000 VA Load Classification Connected Load Demand Factor Demand Load Panel Totals Breaker Accessories (ACC): BL = Breaker Lock / FA = Fire Alarm Circuit Breaker / GF = 30 mA GFCI Circuit Breaker Legend: Total Amps: 20 A 8 A 8 A Total Load: 2.4 1.0 1.0 41 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 42 39 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 40 37 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 38 35 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 36 33 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 34 31 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 32 29 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 30 27 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 28 25 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 26 23 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 24 21 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 22 19 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 20 17 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 18 15 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 16 13 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 14 11 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 12 9 SPARE 20 A 1 0.0 / 0.0 1 20 A SPARE 10 7 SPARE 20 A 1 0.0 / 0.7 8 5 0.3 / 0.7 6 3 0.3 / 0.7 3 20 A Furniture Partitions 4 1 Furniture Partitions 20 A 3 0.3 / 1.4 1 20 A Lighting 2 CKT Circuit Description ACC Trip Poles AΦ (kVA) BΦ (kVA) CΦ (kVA) Poles Trip ACC Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: 225 A Mounting: Recessed Wires: 4 Bus Rating: 200 A Supply From: Phases: 3 Mains Type: MCB Location: DATA ROOM 104 Volts: 120/208 Wye A.I.C. Rating: Panelboard: PDU-2 14 05/01/18 Nick Mishler